Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Talanta ; 160: 36-45, 2016 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-27591585

RESUMO

The Acquired Immune Deficiency Syndrome (AIDS) affects the life of millions of people around the world. Although rapid and low cost screening tests are widely available for the diagnosis of HIV infection, the count of CD4+ T lymphocytes remains a drawback in the areas mostly affected by the HIV, being this control imperative for assessing the deterioration of the immunological system and the progression towards AIDS, when the counting of cells falls down 200cellsµL(-1). This paper describes a high-throughput, simple and rapid method for CD4+ T lymphocytes quantification, directly in whole blood, based on a magneto ELISA. The CD4 cells are separated and preconcentrated from whole blood in magnetic particles, and labeled with an enzyme for the optical readout performed with a standard microplate reader. The magneto ELISA is able to reach the whole CD4 counting range of medical interest, being the limit of detection as low as 50 CD4+ cells per µL of whole blood, without any pretreatment. This method is a highly suitable alternative diagnostic tool for the expensive flow cytometry at the community and primary care level, providing a sensitive method but by using instrumentation widely available in low-resource settings laboratories and requiring low-maintenance, as is the case of a microplate reader operated by filters.

2.
Biosens Bioelectron ; 74: 974-80, 2015 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-26264263

RESUMO

The counting of CD4(+) T lymphocytes is a clinical parameter used for AIDS diagnosis and follow-up. As this disease is particularly prevalent in developing countries, simple and affordable CD4 cell counting methods are urgently needed in resource-limited settings. This paper describes an electrochemical magneto-actuated biosensor for CD4 count in whole blood. The CD4(+) T lymphocytes were isolated, preconcentrated and labeled from 100 µL of whole blood by immunomagnetic separation with magnetic particles modified with antiCD3 antibodies. The captured cells were labeled with a biotinylated antiCD4 antibody, followed by the reaction with the electrochemical reporter streptavidin-peroxidase conjugate. The limit of detection for the CD4 counting magneto-actuated biosensor in whole blood was as low as 44 cells µL(-1) while the logistic range was found to be from 89 to 912 cells µL(-1), which spans the whole medical interest range for CD4 counts in AIDS patients. The electrochemical detection together with the immunomagnetic separation confers high sensitivity, resulting in a rapid, inexpensive, robust, user-friendly method for CD4 counting. This approach is a promising alternative for the costly standard flow cytometry and suitable as diagnostic tool at decentralized practitioner sites in low resource settings, especially in less developed countries.


Assuntos
Síndrome da Imunodeficiência Adquirida/sangue , Contagem de Linfócito CD4/métodos , Linfócitos T CD4-Positivos/citologia , Condutometria/instrumentação , Separação Imunomagnética/instrumentação , Sistemas Microeletromecânicos/instrumentação , Síndrome da Imunodeficiência Adquirida/diagnóstico , Antígenos CD4/análise , Antígenos CD4/sangue , Antígenos CD4/imunologia , Linfócitos T CD4-Positivos/imunologia , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Imunoensaio/instrumentação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Talanta ; 114: 17-24, 2013 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-23953435

RESUMO

In this communication, a new methodology for the simultaneous and automated monitoring of biosorption processes of multimetal mixtures of polluting heavy metals on vegetable wastes based on flow-injection potentiometry (FIP) and electronic tongue detection (ET) is presented. A fixed-bed column filled with grape stalks from wine industry wastes is used as the biosorption setup to remove the metal mixtures from the influent solution. The monitoring system consists in a computer controlled-FIP prototype with the ET based on an array of 9 flow-through ion-selective electrodes and electrodes with generic response to divalent ions placed in series, plus an artificial neural network response model. The cross-response to Cu(2+), Cd(2+), Zn(2+), Pb(2+) and Ca(2+) (as target ions) is used, and only when dynamic treatment of the kinetic components of the transient signal is incorporated, a correct operation of the system is achieved. For this purpose, the FIA peaks are transformed via use of Fourier treatment, and selected coefficients are used to feed an artificial neural network response model. Real-time monitoring of different binary (Cu(2+)/ Pb(2+)), (Cu(2+)/ Zn(2+)) and ternary mixtures (Cu(2+)/ Pb(2+)/ Zn(2+)), (Cu(2+)/ Zn(2+)/ Cd(2+)), simultaneous to the release of Ca(2+) in the effluent solution, are achieved satisfactorily using the reported system, obtaining the corresponding breakthrough curves, and showing the ion-exchange mechanism among the different metals. Analytical performance is verified against conventional spectroscopic techniques, with good concordance of the obtained breakthrough curves and modeled adsorption parameters.


Assuntos
Poluentes Ambientais/análise , Resíduos Industriais/análise , Metais Pesados/análise , Caules de Planta/química , Vitis , Adsorção , Cálcio/análise , Cálcio/química , Eletrodos , Monitoramento Ambiental , Poluentes Ambientais/química , Indústria Alimentícia , Análise de Fourier , Ionóforos/química , Membranas Artificiais , Metais Pesados/química , Redes Neurais de Computação , Plastificantes/química , Cloreto de Polivinila/química , Potenciometria , Vinho
4.
Talanta ; 93: 285-92, 2012 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-22483912

RESUMO

An automated flow injection potentiometric (FIP) system with electronic tongue detection (ET) is used for the monitoring of biosorption processes of heavy metals on vegetable wastes. Grape stalk wastes are used as biosorbent to remove Cu(2+) ions in a fixed-bed column configuration. The ET is formed by a 5-sensor array with Cu(2+) and Ca(2+)-selective electrodes and electrodes with generic response to heavy-metals, plus an artificial neural network response model of the sensor's cross-response. The real-time monitoring of both the Cu(2+) and the cation exchanged and released (Ca(2+)) in the effluent solution is performed by using flow-injection potentiometric electronic tongue system. The coupling of the electronic tongue with automation features of the flow-injection system allows us to accurately characterize the Cu(2+) ion-biosorption process, through obtaining its breakthrough curves, and the profile of the Ca(2+) ion release. In parallel, fractions of the extract solution are analysed by spectroscopic techniques in order to validate the results obtained with the reported methodology. The sorption performance of grape stalks is also evaluated by means of well-established sorption models.


Assuntos
Cobre/metabolismo , Equipamentos e Provisões Elétricas , Poluentes Ambientais/metabolismo , Análise de Injeção de Fluxo/instrumentação , Potenciometria/instrumentação , Verduras/metabolismo , Vitis/metabolismo , Biodegradação Ambiental , Cálcio/química , Cobre/química , Cobre/isolamento & purificação , Poluentes Ambientais/química , Poluentes Ambientais/isolamento & purificação , Troca Iônica , Redes Neurais de Computação , Fatores de Tempo , Água/química
5.
Biosens Bioelectron ; 27(1): 46-52, 2011 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-21764291

RESUMO

Gliadin is a constituent of the cereal protein gluten, responsible for the intolerance generated in celiac disease. Its detection is of high interest for food safety of celiac patients, since the only treatment known until now is a lifelong avoidance of this protein in the diet. Therefore, it is essential to have an easy and reliable method of analysis to control the contents in gluten-free foods. An electrochemical magneto immunosensor for the quantification of gliadin or small gliadin fragments in natural or pretreated food samples is described for the first time and compared to a novel magneto-ELISA system based on optical detection. The immunological reaction was performed on magnetic beads as solid support by the oriented covalent immobilization, of the protein gliadin on tosyl-activated beads. Direct, as well as indirect competitive immunoassays were optimized, achieving the best analytical performance with the direct competitive format. Excellent detection limits (in the order of µg L(-1)) were achieved, according to the legislation for gluten-free products. The matrix effect, as well as the performance of the assays was successfully evaluated using spiked gluten-free foodstuffs (skimmed milk and beer), obtaining excellent recovery values in the results.


Assuntos
Técnicas Biossensoriais , Doença Celíaca/dietoterapia , Dieta Livre de Glúten/normas , Técnicas Eletroquímicas , Inocuidade dos Alimentos/métodos , Gliadina/análise , Imunoensaio , Gliadina/imunologia , Humanos , Limite de Detecção , Fenômenos Magnéticos
6.
Anal Chem ; 83(14): 5570-7, 2011 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-21619038

RESUMO

Magneto immunoassay-based strategies for the detection of Plasmodium falciparum histidine-rich protein 2 (HRP2) related to malaria are described for the first time by using magnetic micro- and nanoparticles. The covalent immobilization of a commercial monoclonal antibody toward the HRP2 protein in magnetic beads and nanoparticles was evaluated and compared. The immunological reaction for the protein HRP2 was successfully performed in a sandwich assay on magnetic micro- and nanoparticles by using a second monoclonal antibody labeled with the enzyme, horseradish peroxidase (HRP). Then, the modified magnetic particles were easily captured by a magneto sensor made of graphite-epoxy composite (m-GEC) which was also used as the transducer for the electrochemical detection. The performance of the immunoassay-based strategy with the electrochemical magneto immunosensors was successfully evaluated and compared with a novel magneto-ELISA based on optical detection using spiked serum samples. Improved sensitivity was obtained when using 300 nm magnetic nanoparticles in both cases. The electrochemical magneto immunosensor coupled with magnetic nanoparticles have shown better analytical performance in terms of limit of detection (0.36 ng mL(-1)), which is much lower than the LOD reported by other methods. Moreover, at a low level of HRP2 concentration of 31.0 ng mL(-1), a signal of 15.30 µA was reached with a cutoff value of 0.34 µA, giving a clear positive result with a non-specific adsorption ratio of 51. Due to the high sensitivity, this novel strategy offers great promise for rapid, simple, cost-effective, and on-site detection of falciparum malaria disease in patients, but also to screen out at-risk blood samples for prevention of transfusion-transmitted malaria.


Assuntos
Imunoensaio/métodos , Imãs/química , Malária/sangue , Nanopartículas/química , Plasmodium falciparum/isolamento & purificação , Proteínas/análise , Proteínas de Protozoários/análise , Anticorpos Imobilizados/imunologia , Técnicas Eletroquímicas/métodos , Humanos , Imunoglobulina M/imunologia , Malária/parasitologia , Proteínas/imunologia , Proteínas de Protozoários/sangue , Proteínas de Protozoários/imunologia , Sensibilidade e Especificidade
7.
Anal Biochem ; 388(2): 229-34, 2009 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-19250919

RESUMO

A novel electrochemical immunosensing strategy for the detection of antibodies to tissue transglutaminase (tTG) in human serum is presented. The proposed immunosensor consists of the immobilization by physical adsorption of tTG from guinea pig liver on graphite-epoxy composite (GEC) electrodes. After the reaction with the human serum (containing the specific antibodies in the case of celiac disease), the electrode was incubated with different kinds of secondary labeled antibodies, namely, horseradish peroxidase (HRP)-conjugated goat antibodies to human whole immunoglobulins (Igs), to human IgG, and finally to human IgA. Among the different classes of antibodies in human serum toward tTG, the best results were achieved when anti-tTG IgA antibodies were investigated. In total, 10 positive and 10 negative serum samples were processed, obtaining a sensitivity of 70% and a specificity of 100% compared with the commercial enzyme-linked immunosorbent assay (ELISA) method performed in a hospital laboratory. This strategy offers great promise for a simple, cost-effective, and user-friendly analytical method that allows point-of-care diagnosis of celiac disease.


Assuntos
Técnicas Biossensoriais/métodos , Doença Celíaca/diagnóstico , Eletroquímica/métodos , Imunoensaio/métodos , Anticorpos/química , Anticorpos/imunologia , Doença Celíaca/sangue , Ensaio de Imunoadsorção Enzimática , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Transglutaminases/imunologia
8.
Biosens Bioelectron ; 24(7): 2057-63, 2009 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-19084389

RESUMO

An immunoassay-based strategy for folic acid in vitamin-fortified milk with electrochemical detection using magneto sensors is described for the first time. Among direct and indirect competitive formats, best performance was achieved with an indirect competitive immunoassay. The immunological reaction for folic acid (FA) detection was performed, for the first time on the magnetic bead as solid support by the covalent immobilization of a protein conjugate BSA-FA on tosyl-activated magnetic bead. Further competition for the specific antibody between FA in the food sample and FA immobilized on the magnetic bead was achieved, followed by the reaction with a secondary antibody conjugated with HRP (AntiIgG-HRP). Then, the modified magnetic beads were easily captured by a magneto sensor made of graphite-epoxy composite (m-GEC) which was also used as the transducer for the electrochemical detection. The performance of the immunoassay-based strategy with electrochemical detection using magneto sensors was successfully evaluated using spiked-milk samples and compared with a novel magneto-ELISA based on optical detection. The detection limit was found to be of the order of microgl(-1) (13.1 nmoll(-1), 5.8 microgl(-1)) for skimmed milk. Commercial vitamin-fortified milk samples were also evaluated obtaining good accuracy in the results. This novel strategy offers great promise for rapid, simple, cost-effective and on-site analysis of biological and food samples.


Assuntos
Eletroquímica/instrumentação , Ácido Fólico/análise , Análise de Alimentos/instrumentação , Alimentos Fortificados/análise , Imunoensaio/instrumentação , Magnetismo/instrumentação , Leite/química , Vitaminas/química , Animais , Técnicas Biossensoriais/instrumentação , Bovinos , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Biosens Bioelectron ; 23(12): 1805-11, 2008 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-18407486

RESUMO

A very sensitive assay for the rapid detection of pathogenic bacteria based on electrochemical genosensing has been designed. The assay was performed by the PCR specific amplification of the eaeA gene, related with the pathogenic activity of Escherichia coli O157:H7. The efficiency and selectivity of the selected primers were firstly studied by using standard Quantitative PCR (Q-PCR) based on TaqMan fluorescent strategy. The bacteria amplicon was detected by using two different electrochemical genosensing strategies, a highly selective biosensor based on a bulk-modified avidin biocomposite (Av-GEB) and a highly sensitive magneto sensor (m-GEC). The electrochemical detection was achieved in both cases by the enzyme marker HRP. The assay showed to be very sensitive, being able to detect 4.5 ng microl(-1) and 0.45 ng microl(-1) of the original bacterial genome after only 10 cycles of PCR amplification, when the first and the second strategies were used, respectively. Moreover, the electrochemical strategies for the detection of the amplicon showed to be more sensitive compared with Q-PCR strategies based on fluorescent labels such as TaqMan probes.


Assuntos
Técnicas Biossensoriais/instrumentação , Contagem de Colônia Microbiana/instrumentação , Eletroquímica/instrumentação , Escherichia coli O157/genética , Escherichia coli O157/isolamento & purificação , Reação em Cadeia da Polimerase/instrumentação , Reação em Cadeia da Polimerase/métodos , Técnicas Biossensoriais/métodos , Contagem de Colônia Microbiana/métodos , Etiquetas de Sequências Expressas
10.
Biosens Bioelectron ; 22(9-10): 1961-7, 2007 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-17010599

RESUMO

Two gold nanoparticles-based genomagnetic sensors designs for detection of DNA hybridization are described. Both assays are based on a magnetically induced direct electrochemical detection of gold tags on magnetic graphite-epoxy composite electrodes. The first design is a two strands assay format that consists of the hybridization between a capture DNA strand which is linked with paramagnetic beads and another DNA strand related to BRCA1 breast cancer gene used as a target which is coupled with streptavidin-gold nanoparticles. The second genomagnetic sensor design is a sandwich assay format with more application possibilities. A cystic fibrosis related DNA strand is used as a target and sandwiched between two complementary DNA probes: the first one linked with paramagnetic beads and a second one modified with gold nanoparticles via biotin-streptavidin complexation reactions. The electrochemical detection of gold nanoparticles by differential pulse voltammetry was performed in both cases. The developed genomagnetic sensors provide a reliable discrimination against noncomplementary DNA as well against one and three-base mismatches. Optimization parameters affecting the hybridization and analytical performance of the developed genosensors are shown for genomagnetic assays of DNA sequences related with the breast cancer and cystic fibrosis genes.


Assuntos
Técnicas Biossensoriais/instrumentação , Eletroquímica/instrumentação , Ouro , Nanopartículas Metálicas , DNA/análise , Hibridização de Ácido Nucleico
11.
Biosens Bioelectron ; 22(9-10): 2010-7, 2007 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-17055717

RESUMO

A sensitive and selective genomagnetic assay for the electrochemical detection of food pathogens based on in situ DNA amplification with magnetic primers has been designed. The performance of the genomagnetic assay was firstly demonstrated for a DNA synthetic target by its double-hybridization with both a digoxigenin probe and a biotinylated capture probe, and further binding to streptavidin-modified magnetic beads. The DNA sandwiched target bound on the magnetic beads is then separated by using a magneto electrode based on graphite-epoxy composite. The electrochemical detection is finally achieved by an enzyme marker, anti-digoxigenin horseradish peroxidase (HRP). The novel strategy was used for the rapid and sensitive detection of polymerase chain reaction (PCR) amplified samples. Promising resultants were also achieved for the DNA amplification directly performed on magnetic beads by using a novel magnetic primer, i.e., the up PCR primer bound to magnetic beads. Moreover, the magneto DNA biosensing assay was able to detect changes at single nucleotide polymorphism (SNP) level, when stringent hybridization conditions were used. The reliability of the assay was tested for Salmonella spp., the most important pathogen affecting food safety.


Assuntos
Primers do DNA , DNA Bacteriano/análise , Microbiologia de Alimentos , Magnetismo , Reação em Cadeia da Polimerase , Salmonella/isolamento & purificação , Técnicas Biossensoriais , Eletroquímica , Salmonella/genética
12.
Biosens Bioelectron ; 22(8): 1707-15, 2007 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-17085033

RESUMO

A novel and very sensitive electrochemical immunosensing strategy for the detection of atrazine based on affinity biocomposite transducers is presented. Firstly, the graphite-epoxy composite transducer was bulk-modified with different universal affinity biomolecules, such as avidin and Protein A. Two strategies for the immobilization of the anti-atrazine antibodies on both biocomposite transducers were evaluated: 'wet-affinity' and 'dry-assisted affinity' immobilization. Finally, the performance of a novel anti-atrazine immunocomposite bulk-modified with anti-atrazine antibodies was also evaluated. The better immobilization performance of the anti-atrazine antibodies was achieved by 'dry-assisted affinity' immobilization on Protein A (2%) graphite-epoxy biocomposite (ProtA(2%)-GEB) as a transducer. The immunological reaction for the detection of atrazine performed on the ProtA(2%)-GEB biosensors is based on a direct competitive assay using atrazine-HRP tracer as the enzymatic label. The electrochemical detection is thus achieved through a suitable substrate and a mediator for the enzyme HRP. This novel strategy was successfully evaluated using spiked orange juice samples. The detection limit for atrazine in orange juices using the competitive electrochemical immunosensing assay was found to be 6 x 10(-3) microgL-1 (0.03 nmolL-1) thus this biosensing method accomplishes by far the LODs required for the European Community directives for potable water and food samples (0.1 microgL-1). This strategy offers great promise for rapid, simple, cost effective, and on-site biosensing of biological, food, and environmental samples.


Assuntos
Atrazina/análise , Técnicas Biossensoriais/métodos , Imunoensaio/métodos , Resíduos de Praguicidas/análise , Atrazina/imunologia , Eletroquímica
13.
Biosens Bioelectron ; 22(9-10): 2184-91, 2007 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-17126544

RESUMO

A novel electrochemical immunosensing strategy for the detection of sulfonamide antibiotics in milk based on magnetic beads is presented. Among the different strategies for immobilizing the class-specific anti-sulfonamide antibody to the magnetic beads--such as those based on the use of Protein A or carboxylate modified magnetic beads - ,the best strategy was found to be the covalent bonding on tosyl-activated magnetic beads. The immunological reaction for the detection of sulfonamide antibiotics performed on the magnetic bead is based on a direct competitive assay using a tracer with HRP peroxidase for the enzymatic labelling. After the immunochemical reactions, the modified magnetic beads can be easily captured by a magneto sensor made of graphite-epoxy composite (m-GEC), which is also used as the transducer for the electrochemical immunosensing. The electrochemical detection is thus achieved through a suitable substrate for the enzyme HRP and an electrochemical mediator. The electrochemical approach is also compared with a novel magneto-ELISA with optical detection. The performance of the electrochemical immunosensing strategy based on magnetic beads was successfully evaluated using spiked milk samples, and the detection limit was found to be 1.44 microg L(-1) (5.92 nmol L(-1)) for raw full cream milk. This strategy offers great promise for rapid, simple, cost-effective and on-site analysis of biological, food and environmental samples.


Assuntos
Antibacterianos/análise , Eletroquímica , Magnetismo , Leite/química , Sulfonamidas/análise , Animais , Antibacterianos/imunologia , Imunoensaio , Sulfonamidas/imunologia
14.
Anal Bioanal Chem ; 385(7): 1195-201, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16826371

RESUMO

Impedance spectroscopy is proposed as the transduction principle for detecting the hybridization of DNA complementary strands. In our experiments, different DNA oligonucleotides were used as model gene substances. The gene probe is first immobilized on a graphite-epoxy composite working electrode based genosensor. Detection principle is based on changes of impedance spectra of a redox marker, the ferro/ferricyanide couple, after hybridization with target DNA. Resistance offered to the electrochemical reaction serves as the working signal, allowing for an unlabelled gene assay.


Assuntos
Impedância Elétrica , Hibridização de Ácido Nucleico , Oligodesoxirribonucleotídeos/análise , Eletrodos , Oligodesoxirribonucleotídeos/isolamento & purificação , Sondas de Oligonucleotídeos , Oxirredução
15.
Anal Bioanal Chem ; 385(7): 1186-94, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16799771

RESUMO

Intelligent and automatic systems based on arrays of non-specific-response chemical sensors were recently developed in our laboratory. For multidetermination applications, the normal choice is an array of potentiometric sensors to generate the signal, and an artificial neural network (ANN) correctly trained to obtain the calibration model. As a great amount of information is required for the proper modelling, we proposed its automated generation by using the sequential injection analysis (SIA) technique. First signals used were steady-state: the equilibrium signal after a step-change in concentration. We have now adapted our procedures to record the transient response corresponding to a sample step. The novelty in this approach is therefore the use of the dynamic components of the signal in order to better discriminate or differentiate a sample. In the developed electronic tongue systems, detection is carried out by using a sensor array formed by five potentiometric sensors based on PVC membranes. For the developed application we employed two different chloride-selective sensors, two nitrate-selective sensors and one generic response sensor. As the amount of raw data (fivefold recordings corresponding to the five sensors) is excessive for an ANN, some feature extraction step prior to the modelling was needed. In order to attain substantial data reduction and noise filtering, the data obtained were fitted with orthonormal Legendre polynomials. In this case, a third-degree Legendre polynomial was shown to be sufficient to fit the data. The coefficients of these polynomials were the input information fed into the ANN used to model the concentrations of the determined species (Cl-, NO3- and HCO3-). Best results were obtained by using a backpropagation neural network trained with the Bayesian regularisation algorithm; the net had a single hidden layer containing three neurons with the tansig transfer function. The results obtained from the time-dependent response were compared with those obtained from steady-state conditions, showing the former superior performance. Finally, the method was applied for determining anions in synthetic samples and real water samples, where a satisfactory comparison was also achieved.


Assuntos
Ânions/análise , Redes Neurais de Computação , Potenciometria/métodos , Algoritmos , Teorema de Bayes , Calibragem , Eletrodos Seletivos de Íons
16.
Anal Chem ; 78(6): 1780-8, 2006 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-16536412

RESUMO

A novel electrochemical immunosensing strategy for the detection of atrazine based on magnetic beads is presented. Different coupling strategies for the modification of the magnetic beads with the specific anti-atrazine antibody have been developed. The immunological reaction for the detection of atrazine performed on the magnetic bead is based on a direct competitive assay using a peroxidase (HRP) tracer as the enzymatic label. After the immunochemical reactions, the modified magnetic beads can be easily captured by a magnetosensor made of graphite-epoxy composite, which is also used as the transducer for the electrochemical immunosensing. The electrochemical detection is thus achieved through a suitable substrate and mediator for the enzyme HRP. The electrochemical approach is also compared with a novel magneto-ELISA based on optical detection. The performance of the electrochemical immunosensing strategy based on magnetic beads was successfully evaluated using spiked real orange juice samples. The detection limit for atrazine using the competitive electrochemical magnetoimmunosensing strategy with anti-atrazine-specific antibody covalent coupled with tosyl-activated magnetic beads was found to be 6 x 10(-3) microg L(-1) (0.027 nmol L(-1)). This strategy offers great promise for rapid, simple, cost-effective, and on-site analysis of biological, food, and environmental samples.


Assuntos
Atrazina/análise , Magnetismo , Resíduos de Praguicidas/análise , Anticorpos/química , Reações Antígeno-Anticorpo , Eletroquímica , Imunoensaio/instrumentação , Imunoensaio/métodos , Tamanho da Partícula , Sensibilidade e Especificidade
17.
Biosens Bioelectron ; 21(7): 1291-301, 2006 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-16098736

RESUMO

Rigid conducting biocomposites are versatile and effective transducing materials for the construction of a wide range of amperometric biosensors such as immunosensors, genosensors and enzymosensors, particularly if the transducer is bulk-modified with universal affinity biomolecules. The strept(avidin)-graphite-epoxy biocomposite could be considered as an universal immobilization platform whereon biotinylated DNAs, oligonucleotides, enzymes or antibodies can be captured by means of the highly affinity (strept)avidin-biotin reaction. Universal affinity biocomposite-based biosensors offer many potential advantages compared to more traditional electrochemical biosensors commonly based on a biologically surface-modified transducer. The integration of many materials into one matrix is their main advantage. As biological bulk-modified materials, the conducting biocomposites act not only as transducers, but also as reservoir for the biomaterial. After its use, the electrode surface can be renewed by a simple polishing procedure, establishing a clear advantage of these approaches relative to classical biosensors and other common biological assays. Moreover, the same material is useful for the analysis of many molecules whose determinations are based on genetic, enzymatic or immunological reactions. The different strategies for electrochemical genosensing, immunosensing and enzymosensing, all of them being dependent on the presence of a redox enzyme marker for the generation of the electrochemical signal, based on this universal affinity biocomposite platform are all presented and discussed.


Assuntos
Técnicas Biossensoriais/instrumentação , Materiais Revestidos Biocompatíveis/química , Eletroquímica/instrumentação , Imunoensaio/instrumentação , Análise de Sequência com Séries de Oligonucleotídeos/instrumentação , Análise Serial de Proteínas/instrumentação , Mapeamento de Interação de Proteínas/instrumentação , Técnicas Biossensoriais/métodos , Materiais Revestidos Biocompatíveis/análise , Eletroquímica/métodos , Resinas Epóxi/análise , Resinas Epóxi/química , Desenho de Equipamento , Análise de Falha de Equipamento , Grafite/análise , Grafite/química , Imunoensaio/métodos , Manufaturas , Técnicas de Sonda Molecular/instrumentação , Análise de Sequência com Séries de Oligonucleotídeos/métodos , Análise Serial de Proteínas/métodos , Mapeamento de Interação de Proteínas/métodos
18.
Analyst ; 130(6): 971-6, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15912248

RESUMO

A new graphite-epoxy composite electrode (GECE) containing Bi(NO(3))(3) as a built-in bismuth precursor for simultaneous and individual anodic stripping analysis of heavy trace metals like lead and cadmium is reported. The developed Bi(NO(3))(3)-GECE is compatible with bismuth film electrodes reported previously including the composite electrodes (Bi-GECE) recently reported by our group. Bi(NO(3))(3)-GECE displays the ability for the detection of both individual and simultaneous determination of heavy trace metals and exhibits well defined, reproducible and sharp stripping signals. The sensitive response is combined with the minimal toxicity of Bi(NO(3))(3). This novel sensor would be an appropriate alternative tool to sensors using bismuth in solution during their utilization in environmental quality monitoring as well as other applications.


Assuntos
Metais Pesados/análise , Bismuto , Eletroquímica , Eletrodos , Propriedades de Superfície
19.
Biosens Bioelectron ; 20(8): 1668-73, 2005 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-15626626

RESUMO

The determination of phenolic compounds is significant given its toxicity, even at very low concentration levels. Amperometric determination of phenols is a simple technique available. Direct oxidation of phenols can be used, but another possibility is the use of polyphenol oxidase (tyrosinase) enzyme biosensors that oxidises the phenolic compounds into their corresponding quinones. Reduction of the resulting quinones accomplishes the amplification of the amperometric signal, as long as the result of the reduction process is the corresponding cathecol, this being able to be oxidised again by the polyphenol oxidase immobilized on the surface of the biosensor. In this communication, simultaneous determination of different phenols was carried out combining biosensor measurements with chemometric tools, in what is known as electronic tongue. The departure information used was the overlapped reduction voltammogram generated with the amperometric biosensor based on polyphenol oxidase. Artificial Neural Networks (ANN) were used for extraction and quantification of each compound. Phenol, cathecol and m-cresol formed the three-analyte study case resolved in this work. Good prediction ability was attained, and so, the separate quantification of these three phenols was accomplished.


Assuntos
Algoritmos , Técnicas Biossensoriais/métodos , Catecol Oxidase/análise , Catecol Oxidase/química , Eletroquímica/métodos , Redes Neurais de Computação , Fenóis/análise , Fenóis/química , Técnicas Biossensoriais/instrumentação , Eletroquímica/instrumentação , Enzimas Imobilizadas/análise , Enzimas Imobilizadas/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
Talanta ; 66(5): 1187-96, 2005 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-18970108

RESUMO

A sequential injection analysis (SIA) system was developed with the aim of obtaining an automatic and versatile way to prepare standards needed in the study of systems with higher dimensional sensor signals. To illustrate this, different analytical techniques were used in determinations of several analytes. Automated potentiometric calibrations of different potentiometric sensors, with and without interference, were carried out. Useful determinations of selectivity coefficients with two degrees of freedom were obtained. Simultaneous voltammetric determinations have also been done. Firstly, simultaneous determinations of lead and cadmium, using epoxy-graphite composite as the working electrode, have enabled a separate calibration for each metal to be obtained. Next, a voltammetric electronic tongue was designed and applied to the determination of oxidizable species. The use of artificial neural networks has solved the overlapped signal of ascorbic acid, 4-aminophenol and 4-acetamidophenol (paracetamol). A set of 63 data points was prepared automatically and has facilitated the training of an electronic tongue for these three analytes. Accurate predictions of test solutions, in the range of 12-410muM for ascorbic acid, 17-530muM for 4-aminophenol and 10-420muM for paracetamol, have been achieved with RMSEs lower than 0.10muM.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...