Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Vasc Surg ; 69: 360-365, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32554200

RESUMO

BACKGROUND: The aim of this study is to present midterm results of thoracic endovascular aortic repair (TEVAR) using scalloped or fenestrated custom-made endovascular grafts (CMEGs) in aortic arch Zones 0 and 1. METHODS: A retrospective review of prospectively collected data involving consecutive patients with aortic arch disease treated by scalloped or fenestrated Relay Plus stent grafts (Terumo Aortic, Sunrise, FL) landed in Zones 0 and 1. Patient demographics, operative details, clinical outcomes, and complications were analyzed. RESULTS: Between February 2014 and February 2020, 14 patients (9 male and 5 female) with a median age of 66 years (range 48-84) underwent scalloped or fenestrated TEVAR to preserve flow to the supra-aortic trunks (SATs). In 6 cases the landing zone was Zone 0 and in 8, Zone 1. Target vessels for the scallops were left common carotid artery in 8 cases (Zone 1) and innominate artery (IA) in 1 (Zone 0). All 5 fenestrations were designed to preserve the IA (Zone 0). Technical success was 100% with no endoleaks on completion angiography. One fatal perioperative stroke (7%) occurred in a patient with a fenestration for the IA and atherosclerotic plaques in the arch. During median follow-up of 37.5 (3-72) months, no other patient died, and all the target vessels and cervical revascularizations remained patent. There was no paraplegia, no retrograde dissection, and no other complication. Two patients (14%) with scallops in Zone 1 developed late endoleak: 1 type Ib at 6 months and 1 type Ia endoleak at 12 months. There were no endoleaks at all in the group of fenestrated endografts (Zone 0). CONCLUSIONS: When anatomy allows, endovascular treatment using scalloped or fenestrated CMEGs in Zones 0 and 1 is a feasible technique to treat patients with aortic arch disease involving the SATs.


Assuntos
Aorta Torácica/cirurgia , Doenças da Aorta/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Idoso , Idoso de 80 Anos ou mais , Aorta Torácica/diagnóstico por imagem , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Fatores de Tempo , Resultado do Tratamento
2.
Vasc Endovascular Surg ; 52(1): 22-26, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29096576

RESUMO

OBJECTIVE: To present our early and midterm results using thoracic endovascular aortic repair (TEVAR) with a custom-made proximal scalloped stent graft to accommodate left common carotid artery (LCCA) and innominate artery (IA) in treating aortic lesions involving the arch. MATERIALS AND METHODS: Between February 2014 and April 2017, select patients presenting with aortic arch lesions and short proximal landing zone were treated by proximal scalloped Relay Plus stent grafts. Patient demographics, operative details, clinical outcomes, and complications were analyzed. RESULTS: Six patients (50% male) with a median age of 71 years (range, 60-82) underwent scalloped TEVAR using thoracic custom-made Relay Plus stent graft to preserve flow in the proximal supra-aortic trunks. Target vessels for the scallop were LCCA in 5 cases and IA in 1 case. The technical success rate was 100%, and proximal seal was achieved in all cases with no type I endoleaks on completion angiography. The median follow-up period was 20 (7-32) months. No conversion to open surgical repair and no aortic rupture occurred. One patient had a distal type I endoleak on the 6-month computed tomography (CT) scan, and 1 patient had a proximal type I endoleak on the 12-month CT scan. There was no stroke, paraplegia, retrograde type A dissection, or other aortic-related complication. We routinely used temporary rapid right ventricular pacing to obtain a near-zero blood pressure level during the graft deployment. No complications were observed related to the use of rapid pacing. CONCLUSION: When anatomy allows, proximal scalloped stent graft to accommodate LCCA and IA is a viable therapeutic option in treating aortic lesions involving the arch with short proximal landing zones. In addition, these findings represent a strong argument for the use of temporary rapid pacing during graft deployment.


Assuntos
Aorta Torácica/cirurgia , Doenças da Aorta/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Desenho de Prótese , Stents , Idoso , Idoso de 80 Anos ou mais , Aorta Torácica/diagnóstico por imagem , Doenças da Aorta/diagnóstico por imagem , Aortografia/métodos , Angiografia por Tomografia Computadorizada , Endoleak/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Espanha , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...