1.
iScience ; 24(5): 102463, 2021 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-34027321

RESUMO

Promoting solar fuels as a viable alternative to hydrocarbons calls for technologies that couple efficiency, durability, and low cost. In this work we elucidate how hybrid organic-inorganic systems employing hybrid photocathodes (HPC) and perovskite solar cells (PSC) could eventually match these needs, enabling sustainable and clean hydrogen production. First, we demonstrate a system comprising an HPC, a PSC, and a Ru-based oxygen evolution catalyst reaching a solar-to-hydrogen (STH) efficiency above 2%. Moving from this experimental result, we elaborate a perspective for this technology by adapting the existing models to the specific case of an HPC-PSC tandem. We found two very promising scenarios: one with a 10% STH efficiency, achievable using the currently available semiconducting polymers and the widely used methylammonium lead iodide (MAPI) PSC, and the other one with a 20% STH efficiency, requiring dedicated development for water-splitting applications of recently reported high-performing organic semiconductors and narrow band-gap perovskites.

2.
ACS Appl Mater Interfaces ; 13(10): 11741-11754, 2021 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-33651944

RESUMO

The use of solution processes to fabricate perovskite solar cells (PSCs) represents a winning strategy to reduce capital expenditure, increase the throughput, and allow for process flexibility needed to adapt PVs to new applications. However, the typical fabrication process for PSC development to date is performed in an inert atmosphere (nitrogen), usually in a glovebox, hampering the industrial scale-up. In this work, we demonstrate, for the first time, the use of double-cation perovskite (forsaking the unstable methylammonium (MA) cation) processed in ambient air by employing potassium-doped graphene oxide (GO-K) as an interlayer, between the mesoporous TiO2 and the perovskite layer and using infrared annealing (IRA). We upscaled the device active area from 0.09 to 16 cm2 by blade coating the perovskite layer, exhibiting power conversion efficiencies (PCEs) of 18.3 and 16.10% for 0.1 and 16 cm2 active area devices, respectively. We demonstrated how the efficiency and stability of MA-free-based perovskite deposition in air have been improved by employing GO-K and IRA.

3.
Clin Chem Lab Med ; 58(10): 1663-1672, 2020 09 25.
Artigo em Inglês | MEDLINE | ID: mdl-31927515

RESUMO

Background The comparability of thyroid-stimulating hormone (TSH) results cannot be easily obtained using SI-traceable reference measurement procedures (RPMs) or reference materials, whilst harmonization is more feasible. The aim of this study was to identify and validate a new approach for the harmonization of TSH results. Methods Percentile normalization was applied to 125,419 TSH results, obtained from seven laboratories using three immunoassays (Access 3rd IS Thyrotropin, Beckman Coulter Diagnostics; Architect System, Abbott Diagnostics and Elecsys, Roche Diagnostics). Recalibration equations (RCAL) were derived by robust regressions using bootstrapped distribution. Two datasets, the first of 119 EQAs, the second of 610, 638 and 639 results from Access, Architect and Elecsys TSH results, respectively, were used to validate RCAL. A dataset of 142,821 TSH values was used to derive reference intervals (RIs) after applying RCAL. Results Access, Abbott and Elecsys TSH distributions were significantly different (p < 0.001). RCAL intercepts and slopes were -0.003 and 0.984 for Access, 0.032 and 1.041 for Architect, -0.031 and 1.003 for Elecsys, respectively. Validation using EQAs showed that before and after RCAL, the coefficients of variation (CVs) or among-assay results decreased from 10.72% to 8.16%. The second validation dataset was used to test RCALs. The median of between-assay differences ranged from -0.0053 to 0.1955 mIU/L of TSH. Elecsys recalibrated to Access (and vice-versa) showed non-significant difference. TSH RI after RCAL resulted in 0.37-5.11 mIU/L overall, 0.49-4.96 mIU/L for females and 0.40-4.92 mIU/L for males. A significant difference across age classes was identified. Conclusions Percentile normalization and robust regression are valuable tools for deriving RCALs and harmonizing TSH values.


Assuntos
Imunoensaio/métodos , Tireotropina/sangue , Calibragem , Sistemas de Informação em Laboratório Clínico , Humanos , Valores de Referência , Reprodutibilidade dos Testes , Tireotropina/normas
4.
Faraday Discuss ; 198: 433-448, 2017 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-28272631

RESUMO

Photoelectrochemical H2 production through hybrid organic/inorganic interfaces exploits the capability of polymeric absorbers to drive photo-induced electron transfer to an electrocatalyst in a water environment. Photoelectrode architectures based on solution-processed organic semiconductors are now emerging as low-cost alternatives to crystalline inorganic semiconductors based on Si, oxides and III-V alloys. In this work, we demonstrate that the stability of a hybrid organic/inorganic photocathode, employing a P3HT:PCBM blend as photoactive material, can be considerably improved by introducing an electrochemically stable WO3 hole selective layer, paired with a TiO2 electron selective layer. This hybrid photoelectrode exhibits a photocurrent of 2.48 mA cm-2 at 0 VRHE, +0.56 VRHE onset potential and a state-of the art operational activity of more than 10 hours. This work gives the perspective that photoelectrodes based on organic semiconductors, coupled with proper inorganic selective contacts, represent a sound new option for the efficient and durable photoelectrochemical conversion of solar energy into fuels.

5.
Clin Chem Lab Med ; 55(11): 1722-1733, 2017 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-28245185

RESUMO

BACKGROUND: Systematic difference between thyroid-stimulating hormone (TSH) immunoassays may produce misleading interpretation when samples of the same patients are measured with different methods. The study aims were to evaluate whether systematic differences are present among TSH immunoassays, and whether it is possible to obtain a better harmonization among TSH methods using results obtained in external quality assessment (EQA) schemes. METHODS: Seven Italian clinical laboratories measured TSH in 745 serum samples of healthy subjects and patients with thyroid disorders. These samples were also re-measured by two reference laboratories of the study with the six TSH immunoassays most popular in Italy after 2 months of storage at -80 °C. Moreover, these data were compared to 53,823 TSH measurements, obtained by laboratories participant to 2012-2015 EQA annual cycles in 72 quality control samples (TSH concentrations from about 0.1 mIU/L to 18.0 mIU/L). TSH concentrations were recalibrated using a mathematical approach based on the principal component analysis (PCA). RESULTS: Systematic differences were found between the most popular commercially available TSH immunoassays. TSH concentrations measured by the clinical laboratories were very closely correlated to those measured with the same method by reference laboratories after 2 months of storage at -80 °C. After recalibration using the PCA approach the variation of TSH values significantly decreased from a median pre-calibration value of 13.53% (10.79%-16.53%) to 9.63% (6.90%-13.21%) after recalibration. CONCLUSIONS: Our data suggest that EQA schemes are useful to improve harmonization among TSH immunoassays and also to produce some mathematical formulas, which can be used by clinicians to better compare TSH values measured with different methods.


Assuntos
Imunoensaio/métodos , Tireotropina/sangue , Calibragem , Humanos , Imunoensaio/normas , Laboratórios/normas , Modelos Lineares , Análise de Componente Principal , Controle de Qualidade , Kit de Reagentes para Diagnóstico , Doenças da Glândula Tireoide/diagnóstico , Tireotropina/normas
6.
Clin Chim Acta ; 468: 105-110, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28189596

RESUMO

AIM OF THE STUDY: Recently, Beckman Coulter Diagnostics set up a new TSH immunoassay for the automated DxI platform. The aim of this study was to evaluate and compare the analytical performance and clinical results of this method with those of previous method. MATERIAL AND METHODS: A multicenter study (named TSH ELAS Study) was organized using 593 serum samples, collected from healthy subjects and patients with thyroid disorders, and 13 control samples, circulated in an External Quality Assessment (EQA) scheme. RESULTS: The values of LoB and LoD, and LoQ at 20% CV were 0.0004mIU/L, 0.001mIU/L and 0.0023mIU/L, respectively. Moreover, TSH concentrations >0.01mIU/L actually show imprecision values lower than 5% CV. This new TSH assay showed a systematic underestimation (on average of 6.25%) compared to old method, which is mainly due to larger differences between methods for samples with low TSH concentrations, related to the better analytical sensitivity of new compared to old method. In a reference population, including 279 apparently healthy adult subjects, Caucasian volunteers (mean age 43.6years, age 20-63years, 138 women and 141 males) the distribution of TSH concentrations was: mean (CI 95%) 1.694mIU/L (1.588-1.779), median 1.495mIU/L (1.412-1.588mIU/L), 97.5th percentile 3.707mIU/L. CONCLUSIONS: The new TSH immunoassay for DxI platform shows some relevant improvements compared to the previous one: use of the most recent WHO 3rd IRP 81/563 standard and monoclonal antibodies (instead of polyclonal antibodies of the old method), and better analytical sensitivities and reproducibility.


Assuntos
Imunoensaio/métodos , Tireotropina/sangue , Adulto , Automação , Estudos de Casos e Controles , Feminino , Humanos , Imunoensaio/normas , Masculino , Pessoa de Meia-Idade , Controle de Qualidade , Valores de Referência , Reprodutibilidade dos Testes , Neoplasias da Glândula Tireoide/sangue , Adulto Jovem
7.
Immunol Res ; 65(1): 299-306, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27475095

RESUMO

To evaluate the analytical agreement between results obtained from the indirect immunofluorescence methods and from the multiplexed line-blot assay and EliA-M2, to analyze the diagnostic accuracy in a cohort of primary biliary cirrhosis (PBC) patients and in control patients of two different types of tests for anti-M2 and assess whether, with the advent of a quantitative test, the possibility exists to correlate disease activity with the value of AMA. Serum analysis of 67 patients with fluorescence patterns detected on Hep-2 cells suggestive of PBC-related antibodies and three groups of patients (15 PBC, 16 PBC suspect and 48 disease controls) was carried out. All samples were tested by both a qualitative test multiplexed line-blot Autoimmune Liver Disease Profile Euroline and by a quantitative test EliA-M2 IgG. In order to evaluate a possible correlation between the quantitative M2 and disease activity, we divided patients mixed in a further three groups based on the value EliA-M2. For each of these groups were calculated the average values of the main indices of cholestasis. A perfect agreement was shown between the EliA-M2 and the multiplexed line-blot method for AMA detection. All sera of patients with PBC were positive with both tests, with a 100 % sensitivity. Forty-seven of the 48 sera of the control group were negative for both tests with a 100 % next specificity, and only 70 % for the AMA-IIF. We had also observed in the other three groups of patients that the average of the values of γ-glutamyl transpeptidase and alkaline phosphatase increases with the increase of the value EliA-M2. The difference between the mean values of the most significant parameter which the alkaline phosphatase of the three groups is significant, with a statistically significant difference between the first and the third group (p value 0.023). Both the qualitative method Profile Euroline and the quantitative EliA-M2 have a high diagnostic accuracy for PBC, with a specificity higher than the immunofluorescence method. These preliminary data might suggest the possibility of using the dosage EliA-M2 not only in the diagnosis phase but also in the monitoring of disease activity.


Assuntos
Autoanticorpos/sangue , Cirrose Hepática Biliar/diagnóstico , Mitocôndrias/imunologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Linhagem Celular Tumoral , Feminino , Humanos , Testes Imunológicos , Cirrose Hepática Biliar/sangue , Cirrose Hepática Biliar/imunologia , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...