1.
J Arrhythm ; 37(6): 1459-1467, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34887950

RESUMO

INTRODUCTION: Endocardial catheter ablation (ECA) for atrial fibrillation (AF) has limited efficacy. Hybrid convergent procedure (HCP) with both epicardial and endocardial ablation is a novel strategy for AF treatment. In this meta-analysis, we aimed to evaluate the efficacy and safety of HCP in AF ablation. METHOD: We performed a comprehensive literature search for studies that evaluated the efficacy and safety of HCP compared with ECA for AF. The primary outcome was freedom of atrial arrhythmia (AA). The secondary outcome was the periprocedural complication rate. Pooled relative risk (RR) and corresponding 95% confidence intervals (CIs) were calculated using the random effects model. RESULTS: A total of eight studies, including 797 AF patients (mean age: 60.7 ± 9.8 years, 366 patients with HCP vs. 431 patients with ECA alone), were included. HCP showed a higher rate of freedom of AA compared with ECA (RR: 1.48, 95% CI: 1.13-1.94, p = .004). However, HCP was associated with higher rates of periprocedural complications (RR: 3.64, 95% CI: 2.06-6.43; p = .00001). Moreover, the HCP had a longer procedure time and postprocedural hospital stay. CONCLUSIONS: Although hybrid ablation was associated with a higher success rate, this should be judged for increased periprocedural adverse events and extended hospital stay. Prospective large-scale randomized trials are needed to validate these results.

SELEÇÃO DE REFERÊNCIAS