Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
World J Radiol ; 11(5): 62-73, 2019 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-31205601

RESUMO

BACKGROUND: Chronic cocaine use is associated with stroke, coronary artery disease and myocardial infarction, resulting in severe impairments or sudden mortality. In the absence of clear cardiovascular symptoms, individuals with cocaine use disorder (iCUD) seeking addiction treatment receive mostly psychotherapy and psychiatric pharmacotherapy, with no attention to vascular disease (i.e., atherosclerosis). Little is known about the pre-clinical signs of cardiovascular risk in iCUD and early signs of vascular disease are undetected in this underserved population. AIM: To assess inflammation, plaque burden and plaque composition in iCUD aiming to detect markers of atherosclerosis and vascular disease. METHODS: The bilateral carotid arteries were imaged with positron emission tomography/magnetic resonance imaging (PET/MRI) in iCUD asymptomatic for cardiovascular disease, healthy controls, and individuals with cardiovascular risk. PET with 18F-fluorodeoxyglucose (18F-FDG) evaluated vascular inflammation and 3-D dark-blood MRI assessed plaque burden including wall area and thickness. Drug use and severity of addiction were assessed with standardized instruments. RESULTS: The majority of iCUD and controls had carotid FDG-PET signal greater than 1.6 but lower than 3, indicating the presence of mild to moderate inflammation. However, the MRI measure of wall structure was thicker in iCUD as compared to the controls and cardiovascular risk group, indicating greater carotid plaque burden. iCUD had larger wall area as compared to the healthy controls but not as compared to the cardiovascular risk group, indicating structural wall similarities between the non-control study groups. In iCUD, wall area correlated with greater cocaine withdrawal and craving. CONCLUSION: These preliminary results show markers of carotid artery disease burden in cardiovascular disease-asymptomatic iCUD. Broader trials are warranted to develop protocols for early detection of cardiovascular risk and preventive intervention in iCUD.

2.
J Am Coll Cardiol ; 68(16): 1769-1780, 2016 10 18.
Artigo em Inglês | MEDLINE | ID: mdl-27737744

RESUMO

BACKGROUND: Evidence suggests that interleukin (IL)-1ß is important in the pathogenesis of atherosclerosis and its complications and that inhibiting IL-1ß may favorably affect vascular disease progression. OBJECTIVES: The goal of this study was to evaluate the effects of IL-1ß inhibition with canakinumab versus placebo on arterial structure and function, determined by magnetic resonance imaging. METHODS: Patients (N = 189) with atherosclerotic disease and either type 2 diabetes mellitus or impaired glucose tolerance were randomized to receive placebo (n = 94) or canakinumab 150 mg monthly (n = 95) for 12 months. They underwent magnetic resonance imaging of the carotid arteries and aorta. RESULTS: There were no statistically significant differences between canakinumab compared with placebo in the primary efficacy and safety endpoints. There was no statistically significant change in mean carotid wall area and no effect on aortic distensibility, measured at 3 separate anatomic sites. The change in mean carotid artery wall area was -3.37 mm2 after 12 months with canakinumab versus placebo. High-sensitivity C-reactive protein was significantly reduced by canakinumab compared with placebo at 3 months (geometric mean ratio [GMR]: 0.568; 95% confidence interval [CI]: 0.436 to 0.740; p < 0.0001) and 12 months (GMR: 0.56; 95% CI: 0.414 to 0.758; p = 0.0002). Lipoprotein(a) levels were reduced by canakinumab compared with placebo (-4.30 mg/dl [range: -8.5 to -0.55 mg/dl]; p = 0.025] at 12 months), but triglyceride levels increased (GMR: 1.20; 95% CI: 1.046 to 1.380; p = 0.01). In these patients with type 2 diabetes mellitus or impaired glucose tolerance, canakinumab had no effect compared with placebo on any of the measures assessed by using a standard oral glucose tolerance test. CONCLUSIONS: There were no statistically significant effects of canakinumab on measures of vascular structure or function. Canakinumab reduced markers of inflammation (high-sensitivity C-reactive protein and interleukin-6), and there were modest increases in levels of total cholesterol and triglycerides. (Safety & Effectiveness on Vascular Structure and Function of ACZ885 in Atherosclerosis and Either T2DM or IGT Patients; NCT00995930).


Assuntos
Anticorpos Monoclonais/farmacologia , Anticorpos Monoclonais/uso terapêutico , Artérias/efeitos dos fármacos , Aterosclerose/complicações , Aterosclerose/tratamento farmacológico , Diabetes Mellitus Tipo 2/complicações , Intolerância à Glucose/complicações , Interleucina-1beta/antagonistas & inibidores , Anticorpos Monoclonais Humanizados , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
3.
J Vis Exp ; (100): e52761, 2015 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-26065866

RESUMO

We evaluated a magnetic resonance venography (MRV) approach with gadofosveset to quantify total thrombus volume changes as the principal criterion for treatment efficacy in a multicenter randomized study comparing edoxaban monotherapy with a heparin/warfarin regimen for acute, symptomatic lower extremities deep vein thrombosis (DVT) treatment. We also used a direct thrombus imaging approach (DTHI, without the use of a contrast agent) to quantify fresh thrombus. We then sought to evaluate the reproducibility of the analysis methodology and applicability of using 3D magnetic resonance venography and direct thrombus imaging for the quantification of DVT in a multicenter trial setting. From 10 randomly selected subjects participating in the edoxaban Thrombus Reduction Imaging Study (eTRIS), total thrombus volume in the entire lower extremity deep venous system was quantified bilaterally. Subjects were imaged using 3D-T1W gradient echo sequences before (direct thrombus imaging, DTHI) and 5 min after injection of 0.03 mmol/kg of gadofosveset trisodium (magnetic resonance venography, MRV). The margins of the DVT on corresponding axial, curved multi-planar reformatted images were manually delineated by two observers to obtain volumetric measurements of the venous thrombi. MRV was used to compute total DVT volume, whereas DTHI was used to compute volume of fresh thrombus. Intra-class correlation (ICC) and Bland Altman analysis were performed to compare inter and intra-observer variability of the analysis. The ICC for inter and intra-observer variability was excellent (0.99 and 0.98, p <0.001, respectively) with no bias on Bland-Altman analysis for MRV images. For DTHI images, the results were slightly lower (ICC = 0.88 and 0.95 respectively, p <0.001), with bias for inter-observer results on Bland-Altman plots. This study showed feasibility of thrombus volume estimation in DVT using MRV with gadofosveset trisodium, with good intra- and inter-observer reproducibility in a multicenter setting.


Assuntos
Angiografia por Ressonância Magnética/métodos , Piridinas/uso terapêutico , Tiazóis/uso terapêutico , Trombose Venosa/diagnóstico , Trombose Venosa/tratamento farmacológico , Meios de Contraste , Gadolínio , Humanos , Perna (Membro)/irrigação sanguínea , Compostos Organometálicos , Pelve/irrigação sanguínea , Reprodutibilidade dos Testes , Trombose Venosa/patologia
4.
World J Radiol ; 6(5): 192-202, 2014 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-24876923

RESUMO

AIM: To compare 3D Black Blood turbo spin echo (TSE) sampling perfection with application-optimized contrast using different flip angle evolution (SPACE) vs 2D TSE in evaluating atherosclerotic plaques in multiple vascular territories. METHODS: The carotid, aortic, and femoral arterial walls of 16 patients at risk for cardiovascular or atherosclerotic disease were studied using both 3D black blood magnetic resonance imaging SPACE and conventional 2D multi-contrast TSE sequences using a consolidated imaging approach in the same imaging session. Qualitative and quantitative analyses were performed on the images. Agreement of morphometric measurements between the two imaging sequences was assessed using a two-sample t-test, calculation of the intra-class correlation coefficient and by the method of linear regression and Bland-Altman analyses. RESULTS: No statistically significant qualitative differences were found between the 3D SPACE and 2D TSE techniques for images of the carotids and aorta. For images of the femoral arteries, however, there were statistically significant differences in all four qualitative scores between the two techniques. Using the current approach, 3D SPACE is suboptimal for femoral imaging. However, this may be due to coils not being optimized for femoral imaging. Quantitatively, in our study, higher mean total vessel area measurements for the 3D SPACE technique across all three vascular beds were observed. No significant differences in lumen area for both the right and left carotids were observed between the two techniques. Overall, a significant-correlation existed between measures obtained between the two approaches. CONCLUSION: Qualitative and quantitative measurements between 3D SPACE and 2D TSE techniques are comparable. 3D-SPACE may be a feasible approach in the evaluation of cardiovascular patients.

5.
Clin Med Insights Cardiol ; 8(Suppl 3): 13-21, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25674025

RESUMO

Atherosclerosis is a prevalent cardiovascular disease marked by inflammation and the formation of plaque within arterial walls. As the disease progresses, there is an increased risk of major cardiovascular events. Owing to the nature of atherosclerosis, it is imperative to develop methods to further understand the physiological implications and progression of the disease. The combination of positron emission tomography (PET)/computed tomography (CT) has proven to be promising for the evaluation of atherosclerotic plaques and inflammation within the vessel walls. The utilization of the radiopharmaceutical tracer, 18F-fluorodeoxyglucose ((18)F-FDG), with PET/CT is invaluable in understanding the pathophysiological state involved in atherosclerosis. In this review, we will discuss the use of (18)F-FDG-PET/CT imaging for the evaluation of atherosclerosis and inflammation both in preclinical and clinical studies. The potential of more specific novel tracers will be discussed. Finally, we will touch on the potential benefits of using the newly introduced combined PET/magnetic resonance imaging (MRI) for non-invasive imaging of atherosclerosis.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...