Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Oral Health ; 24(1): 760, 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38965507

RESUMO

BACKGROUND: Preservation of the remaining structures while maintaining an esthetic appearance is a major objective in removable partial prosthodontics. So, the aim of the current study was to compare the stresses induced on the supporting structures by two digitally produced esthetic core materials; Zirconia and Polyetheretherketone when used as an extracoronal attachment in distal extension removable partial dentures using strain gauge analysis. METHODS: A mandibular Kennedy class II stone cast with the necessary abutments' preparations was scanned. The mandibular left canine and first premolar teeth were virtually removed. An acrylic mandibular left canine and first premolar teeth were prepared with heavy chamfer finish line and scanned. Virtual superimposition of the acrylic teeth in their corresponding positions was done. Two strain gauge slots were designed: distal to the terminal abutment and in the residual ridge. Two models and two sets of scanned teeth were digitally printed. The printed teeth were then placed in their corresponding sockets in each model and scanned. The attachment design was selected from the software library and milled out of Zirconia in the model ZR and Polyetheretherketone in the model PE. Five removable partial dentures were constructed for each model. The strain gauges were installed in their grooves. A Universal testing machine was used for unilateral load application of 100 N (N). For each removable partial denture, five measurements were made. The data followed normal distribution and were statistically analyzed by using unpaired t test. P value < 0.05 was considered to be statistically significant. RESULTS: During unilateral loading unpaired t test showed statistically significant difference (p = 0.0001) in the microstrain values recorded distal to the abutment between the models ZR (-1001.6 µÎµ ± 24.56) and PE (-682.6 µÎµ ± 22.18). However, non statistically significant difference (p = 0.3122) was observed in the residual ridge between them; ZR (16.2 µÎµ ± 4.53) and PE (15 µÎµ ± 3.74). CONCLUSIONS: In removable partial dentures, Polyetheretherketone extracoronal attachment induces less stress on the supporting abutments compared to the zirconia one with no difference in the stresses induced by them on the residual ridge.


Assuntos
Benzofenonas , Planejamento de Dentadura , Prótese Parcial Removível , Cetonas , Polímeros , Zircônio , Cetonas/química , Humanos , Zircônio/química , Polietilenoglicóis , Análise do Estresse Dentário , Materiais Dentários/química , Desenho Assistido por Computador , Dente Suporte , Estresse Mecânico , Estética Dentária , Teste de Materiais
2.
Lupus ; 29(8): 943-953, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32580679

RESUMO

BACKGROUND: C4d, which is a serum complement cleavage product of the activated complement component C4, was found to be an accurate indicator of lupus activity compared to complement levels. Recently, macrophages have been considered to be pivotal members in the pathogenesis of lupus nephritis (LN). M2c-like macrophages have anti-inflammatory functions and promote fibrosis. Multiple studies have detected that LN is associated with an imbalance between the regulatory T cell (Treg) population and the inflammatory T helper subtypes. METHODS: We evaluated and scored the immunohistochemical expression of C4d, CD163-positive M2C-macrophages and Foxp3-expressing Tregs in 53 renal biopsies of LN. Their expression was scored and correlated with clinical and histological disease activity and chronicity. RESULTS: Class IV was the most prevalent class (50.9%), followed by class III (17%). PTC-C4d intensity score, CD163% of positive M2c macrophages and FOXP3% of positive Tregs were significantly correlated with chronicity index (rs = 0.292, p = 0.034; rs = 0.407, p = 0.003; and rs = 0.296, p = 0.031, respectively). Also, FOXP3% of positive Tregs was significantly correlated with LN class (rs = 0.31, p = 0.024). CONCLUSION: C4d-PTC, CD163-positive M2c macrophages and FOXP3-positive Tregs are markers that significantly correlated with chronicity in LN. Further studies are needed to evaluate their prognostic value.


Assuntos
Nefrite Lúpica/imunologia , Nefrite Lúpica/patologia , Macrófagos/imunologia , Linfócitos T Reguladores/imunologia , Adolescente , Adulto , Antígenos CD/imunologia , Antígenos de Diferenciação Mielomonocítica/imunologia , Biópsia , Criança , Pré-Escolar , Complemento C4/imunologia , Feminino , Fatores de Transcrição Forkhead/imunologia , Humanos , Imuno-Histoquímica , Macrófagos/citologia , Masculino , Pessoa de Meia-Idade , Receptores de Superfície Celular/imunologia , Estudos Retrospectivos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...