Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Osteoarthritis Cartilage ; 29(4): 480-490, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33588086

RESUMO

OBJECTIVE: To evaluate the efficacy of carbon-fibre shoe-stiffening inserts in individuals with first metatarsophalangeal joint osteoarthritis. DESIGN: This was a randomised, sham-controlled, participant- and assessor-blinded trial. One hundred participants with first metatarsophalangeal joint osteoarthritis received rehabilitation therapy and were randomised to receive either carbon fibre shoe-stiffening inserts (n = 49) or sham inserts (n = 51). The primary outcome measure was the Foot Health Status Questionnaire (FHSQ) pain domain assessed at 12 weeks. RESULTS: All 100 randomised participants (mean age 57.5 (SD 10.3) years; 55 (55%) women) were included in the analysis of the primary outcome. At the 12 week primary endpoint, there were 13 drop-outs (7 in the sham insert group and 6 in the shoe-stiffening insert group), giving completion rates of 86 and 88%, respectively. Both groups demonstrated improvements in the FHSQ pain domain score at each follow-up period, and there was a significant between-group difference in favour of the shoe-stiffening insert group (adjusted mean difference of 6.66 points, 95% CI 0.65 to 12.67, P = 0.030). There were no between-group differences for the secondary outcomes, although global improvement was more common in the shoe-stiffening insert group compared to the sham insert group (61 vs 34%, RR 1.73, 95% CI 1.05 to 2.88, P = 0.033; number needed to treat 4, 95% CI 2 to 16). CONCLUSION: Carbon-fibre shoe-stiffening inserts were more effective at reducing foot pain than sham inserts at 12 weeks. These results support the use of shoe-stiffening inserts for the management of this condition, although due to the uncertainty around the effect on the primary outcome, some individuals may not experience a clinically worthwhile improvement.


Assuntos
Órtoses do Pé , Articulação Metatarsofalângica , Osteoartrite/reabilitação , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibra de Carbono , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor , Inquéritos e Questionários , Resultado do Tratamento , Adulto Jovem
2.
Resuscitation ; 47(3): 301-5, 2000 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11114460

RESUMO

BACKGROUND: Cardiopulmonary resuscitation (CPR) improves survival from cardiac arrest. The interactions between CPR and the new biphasic (BiP) defibrillation waveforms have not been defined. Our purpose was to compare the effect of CPR versus no CPR during BiP and damped sinusoidal (DS) shocks on the termination of ventricular fibrillation (VF) and the resumption of a perfusing rhythm. METHODS: We studied 20 pigs; VF was induced electrically and allowed to persist for 6 min. During VF episodes each pig received (in random order): (a) 6 min of full CPR (continuous ventilation and closed chest mechanical compression (Thumper, Michigan Instruments)) followed by DS defibrillation at 100 J; (b) no CPR, DS defibrillation; (c) 6 min of full CPR and BiP defibrillation at 100 J; and (d) no CPR, BiP defibrillation. RESULTS: BiP shocks with CPR terminated VF in 83% of attempts versus 45% without CPR (15/18 and 5/11 respectively, P<0.05). DS shocks with CPR were successful in terminating VF in 53% of attempts; DS shocks without CPR were successful in 44% (8/15 and 7/16, respectively, P=NS). No animal achieved a perfusing rhythm after shocks of either waveform if CPR did not precede the shocks during the 6-min VF period, whereas if CPR was administered during VF 46% (11/24) of the combined BiP/DS shocks restored a perfusing rhythm (P<0.01). CONCLUSION: In this experimental long duration VF model, CPR was essential for a perfusing rhythm after termination of VF by shocks with either waveform. CPR facilitated the termination of VF and resumption of a perfusing rhythm after biphasic waveform defibrillation but not after damped sinusoidal waveform defibrillation.


Assuntos
Reanimação Cardiopulmonar/métodos , Cardioversão Elétrica/métodos , Frequência Cardíaca/fisiologia , Animais , Pressão Sanguínea/fisiologia , Reanimação Cardiopulmonar/instrumentação , Reanimação Cardiopulmonar/estatística & dados numéricos , Modelos Animais de Doenças , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/estatística & dados numéricos , Parada Cardíaca/etiologia , Parada Cardíaca/fisiopatologia , Parada Cardíaca/terapia , Distribuição Aleatória , Suínos , Fibrilação Ventricular/complicações , Fibrilação Ventricular/fisiopatologia , Fibrilação Ventricular/terapia
3.
J Am Coll Cardiol ; 32(7): 2065-71, 1998 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-9857894

RESUMO

OBJECTIVES: This study was performed to determine the efficacy of new encircling overlapping multipulse, multipathway waveforms for transthoracic defibrillation. BACKGROUND: Alternative waveforms for transthoracic defibrillation may improve shock success. METHODS: First, we determined the shock success achieved by three different waveforms at varying energies (18-150 J) in 21 mongrel dogs after short-duration ventricular fibrillation. The waveforms tested included the traditional damped sinusoidal waveform, a single pathway biphasic waveform, and a new encircling overlapping multipulse waveform delivered from six electrode pads oriented circumferentially. Second, in 11 swine we compared the efficacy of encircling overlapping multipulse shocks given from six electrode pads and three capacitors versus encircling overlapping shocks given from a device utilizing three electrodes and one capacitor. RESULTS: In the first experiment, the encircling overlapping waveform performed significantly better than biphasic and damped sinusoidal waveforms at lower energies. The shock success rate of the overlapping waveform (six pads) ranged from 67+/-4% (at 18-49 J energy) to 99+/-3% at > or = 150 J; at comparable energies biphasic waveform shock success ranged from 26+/-5% (p < 0.01 vs. encircling overlapping waveforms) to 99+/-5% (p = NS). Damped sinusoidal waveform shock success ranged from 4+/-1% (p < 0.01 vs. encircling overlapping waveform) to 73+/-9% (p = NS). In the second experiment the three electrode pads, one capacitor encircling waveform achieved shock success rates comparable with the six-pad, three-capacitor waveform; at 18-49 J, success rates were 45+/-15% versus 57+/-12%, respectively (p = NS). At 100 J, success rates for both were 100%. CONCLUSIONS: We conclude that encircling overlapping multipulse multipathway waveforms facilitate transthoracic defibrillation at low energies. These waveforms can be generated from a device that requires only three electrodes and one capacitor.


Assuntos
Cardioversão Elétrica/métodos , Fibrilação Ventricular/terapia , Animais , Cães , Estudos de Avaliação como Assunto , Suínos
4.
J Am Soc Echocardiogr ; 11(10): 921-8, 1998 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9804096

RESUMO

PURPOSE: Our purpose was to demonstrate that intracardiac ultrasound imaging from a transducer placed in the right ventricle can be used to quantitatively image the left ventricle in a swine model. BACKGROUND: The left ventricles and right ventricles of dogs and human beings have been studied with intracardiac echocardiography. Usually intracardiac echocardiography has been performed with the ultrasound catheter in the chamber being studied because of limited depth of field. Thus left ventricular imaging required that the ultrasound catheter be placed intra-arterially and manipulated into the left ventricle. The availability of lower frequency ultrasound catheters may allow left ventricular imaging from the right ventricle--a more clinically attractive approach. METHODS: In 10 closed chest swine, a 10F, 10-MHz ultrasound catheter was placed into the right ventricle through an introducer sheath placed in the right internal jugular vein. Two-dimensional transthoracic echo images were obtained for comparison. Two protocols were used to image global left ventricular function and regional wall motion during pharmacologic challenge. In protocol 1 (n = 4) we evaluated global left ventricular performance in response to interventions: dobutamine, halothane (a myocardial depressant), nitroprusside, and volume loading. In protocol 2 (n = 6) we evaluated regional contraction abnormalities induced by coronary arterial balloon inflation and deflation (reperfusion) and dobutamine. At baseline and after each intervention, global function of the right ventricle and left ventricle was measured as cross-sectional end-diastolic area and end-systolic area, and regional contraction was evaluated as the percentage of left ventricular circumference with a wall motion abnormality. Intracardiac pressures and cardiac output were also measured for comparison. Left ventricular cross-sectional area ejection fractions (area EF) were calculated for both intracardiac and transthoracic echo images as (end-diastolic cross-sectional area - end-systolic cross-sectional area)/end-diastolic cross-sectional area. RESULTS: The 10F, 10-MHz intracardiac ultrasound catheter successfully imaged the left ventricle from the right ventricle in all 10 swine. In protocol 1, dobutamine increased area EF from a baseline of 0.60 +/- 0.03 to 0.87 +/- 0.04 (P < .05). When dobutamine was added to the myocardial depressant halothane, left ventricular area EF increased from a baseline of 0.55 +/- 0.03 to 0.68 +/- 0.04. In protocol 2, coronary occlusion resulted in a detectable regional wall motion abnormality (circumferential percentage) of 23% +/- 3%. After reperfusion and during dobutamine stimulation, the wall abnormality decreased to 12% +/- 4%. Transthoracic echocardiography correlated well with these intracardiac findings. CONCLUSIONS: The left ventricle can be quantitatively imaged from the right ventricle with the use of a 10F, 10-MHz intracardiac catheter in swine. This system can detect changes in global and regional left ventricular systolic function. This technique warrants evaluation in clinical applications.


Assuntos
Ventrículos do Coração/diagnóstico por imagem , Ultrassonografia de Intervenção/métodos , Função Ventricular Esquerda , Animais , Hemodinâmica , Suínos
5.
J Am Soc Echocardiogr ; 11(2): 149-54, 1998 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-9517554

RESUMO

Our objective is to develop a new transthoracic Doppler echocardiographic technique to determine mitral regurgitant fraction. The standard color Doppler method for assessment of mitral regurgitation is semiquantitative and dependent on instrument gain. By using the mitral and aortic valve continuous wave Doppler velocities, one can determine regurgitant fraction. This technique takes into account the flow dependence of the mitral valve area. Two constants, A and B, which represent the flow dependence of the mitral valve area and the ratio of the mitral valve area to aortic valve area at zero flow, respectively, were determined by regression in 36 patients without valvular disease (r = .89). Thirty patients with isolated mitral regurgitation were then studied. The mitral regurgitant fraction was calculated from the following: Regurgitant fraction = 1 - TVIav/Bf[Vmv/(1 - AVmv)]dt, where TVIav is the time velocity integral across the aortic valve, Vmv is the continuous wave velocity across the mitral valve, and A and B are constants. The regurgitant fraction was then compared with color Doppler assessment of mitral regurgitation assessed by independent observers. In patients with mitral regurgitation, there was a strong correlation between standard visual assessment and our new Doppler method (Kendall's tau b rank correlation = 0.65; p < .001). The new Doppler method was able to correctly categorize 90% of patients with mild mitral regurgitation and 88% of patients with severe mitral regurgitation; however, there was poorer agreement with the color Doppler assessment of moderate mitral regurgitation. Mitral regurgitant fraction can be calculated with our new Doppler method. This method is quantitative, objective, nongain dependent, and separates mild from severe mitral regurgitation well.


Assuntos
Ecocardiografia Doppler/métodos , Insuficiência da Valva Mitral/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia
6.
J Am Coll Cardiol ; 30(4): 1052-6, 1997 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9316538

RESUMO

OBJECTIVES: The present study was designed to assess the impact of direct current shocks on cardiac troponin I (cTnI), which has greater sensitivity and specificity than creatine kinase (CK) for the diagnosis of myocardial injury. BACKGROUND: Transthoracic direct current shocks can cause myocardial injury. They also cause elevations of total CK and CK-MB fraction (CK-MB). METHODS: We obtained measurements of cTnI total CK and CK-MB before and after elective cardioversions in 38 patients. Blood samples were drawn before and 8, 16, 24 and 48 h after cardioversion. Shock energy, current, impedance and number of shocks delivered were tabulated. RESULTS: Patients received a mean (+/-SD) of 2.1 +/- 1.2 shocks with a median cumulative energy of 300 J (range 50 to 1,580). Three patients had minimal elevations (1.5, 1.2 and 0.8 ng/ml, normal < or = 0.6 ng/ml) of cTnI. Two of these patients had impaired left ventricular contractility by echocardiography. Thirty-five of the 38 patients had no elevations of cTnI. Sixty-two percent of patients had an increase in CK after cardioversion, but CK-MB was elevated to an abnormal level of 12.7 ng/ml (normal < 6.7) in only one patient after cardioversion. CONCLUSIONS: Cardiac troponin I levels are either normal or minimally elevated after elective direct current cardioversion, suggesting that subtle myocardial injury can be caused by direct current transthoracic shocks. However, substantial elevations of cTnI after cardioversion suggest the presence of myocardial injury from causes unrelated to the direct current shocks administered for cardioversion.


Assuntos
Creatina Quinase/sangue , Cardioversão Elétrica/efeitos adversos , Traumatismos Cardíacos/etiologia , Traumatismos Cardíacos/metabolismo , Troponina I/sangue , Idoso , Diagnóstico Diferencial , Cardioversão Elétrica/métodos , Feminino , Traumatismos Cardíacos/diagnóstico , Traumatismos Cardíacos/diagnóstico por imagem , Traumatismos Cardíacos/fisiopatologia , Humanos , Isoenzimas , Masculino , Contração Miocárdica , Pletismografia de Impedância , Sensibilidade e Especificidade , Fatores de Tempo , Ultrassonografia
7.
J Am Soc Echocardiogr ; 10(6): 673-6, 1997.
Artigo em Inglês | MEDLINE | ID: mdl-9282357

RESUMO

Spontaneous echocardiographic contrast may be seen in the false and true lumens of dissecting aortic aneurysms. Using transesophageal echocardiography, we identified the false lumen as the source of spontaneous echocardiographic contrast in the true lumen of a patient with an aortic dissection.


Assuntos
Aneurisma da Aorta Torácica/diagnóstico por imagem , Dissecção Aórtica/diagnóstico por imagem , Idoso , Aorta Torácica/diagnóstico por imagem , Ecocardiografia Doppler em Cores , Ecocardiografia Transesofagiana , Humanos , Masculino
9.
Clin Cardiol ; 20(3): 307-9, 1997 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-9068923

RESUMO

Right-to-left intracardiac shunting across a patent foramen ovale (PFO) has been reported in patients with pulmonary embolism, right ventricular (RV) infarction, positive pressure ventilation with positive end-expiratory pressure, heart failure with left ventricular assist devices, cardiac tamponade, and unilateral diaphragmatic paralysis. The primary driving force for these shunts is a reduction in the compliance of the pulmonary bed or right ventricle; right atrial pressure is usually elevated and pulmonary hypertension is frequently present. Significant shunting and hypoxemia are unusual in the absence of these diseases. We encountered a patient with normal pulmonary pressures, severe hypoxemia, pulmonary disease, and intracardiac shunting across a PFO in whom it was difficult to determine how great a role intracardiac shunting was playing in his hypoxemia. To assess this, we performed percutaneous balloon catheter occlusion of the PFO, using transthoracic echocardiography with contrast to confirm closure of the PFO. Therapeutic balloon occlusion has been reported in severe hypoxemia due to shunting across a PFO in a patient with RV infarction. Our case is unique, however, in two respects. First, this patient had normal right-sided cardiac pressures and normal RV function and, thus, no obvious driving force for a significant right-to-left shunt. Second, transthoracic echocardiography with contrast was used before and after balloon inflation to confirm closure of the PFO. This technique helped to answer the important clinical question of whether surgical closure of the PFO in this patient with both lung disease and intracardiac shunting would significantly improve his oxygenation.


Assuntos
Oclusão com Balão , Cateterismo , Comunicação Interatrial/fisiopatologia , Hipóxia/etiologia , Atelectasia Pulmonar/complicações , Função Ventricular Direita , Adulto , Comunicação Interatrial/complicações , Comunicação Interatrial/cirurgia , Humanos , Masculino , Atelectasia Pulmonar/fisiopatologia , Circulação Pulmonar , Pressão Ventricular
11.
Am J Cardiol ; 71(11): 897-901, 1993 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-8465778

RESUMO

Patients with multivessel coronary artery disease and left ventricular dysfunction represent a high-risk subgroup in whom coronary artery bypass grafting has been shown to improve survival compared with that of medically treated patients. The comparative benefits and risks of coronary angioplasty and bypass surgery in this subgroup of patients are unclear. This study retrospectively analyzes 100 consecutive patients treated with bypass surgery compared with a matched, concurrent cohort of 100 treated with multivessel angioplasty. Early results favored angioplasty; a hospital stay of 12.8 days was noted in the bypass group compared with 4.3 days in the angioplasty group (p < 0.001). In-hospital mortality rates were similar in the bypass (5%) and angioplasty (3%) groups (p = NS). Stroke was observed significantly more often in the bypass group (7 vs 0%). However, late follow-up favored bypass patients; repeat revascularization procedures and late myocardial infarction occurred more frequently during follow-up in the angioplasty group. During 5-year follow-up, superior relief from disabling angina (99 vs 89%; p = 0.01) and a trend toward improved survival (76 vs 67%; p = 0.09) were observed in the bypass group as compared with the angioplasty group. Multivariate correlates of late mortality included age and incomplete revascularization, but not mode of revascularization. Thus, in patients with multivessel coronary artery disease and left ventricular dysfunction, early results favor angioplasty, whereas late follow-up favors bypass surgery. However, late survival was similar in both groups of patients who were completely revascularized.


Assuntos
Angioplastia Coronária com Balão , Ponte de Artéria Coronária , Doença das Coronárias/terapia , Volume Sistólico , Análise Atuarial , Idoso , Doença das Coronárias/mortalidade , Doença das Coronárias/fisiopatologia , Feminino , Seguimentos , Mortalidade Hospitalar , Humanos , Masculino , Complicações Pós-Operatórias/epidemiologia , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Taxa de Sobrevida , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...