1.
Rev Sci Instrum ; 95(5)2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38743571

RESUMO

The MAST-U Super-X divertor provides the opportunity to study fusion plasma exhaust under novel conditions. However, in order to study these conditions, advanced diagnostics are required. Following the development of the MAST-U Multi-Wavelength Imaging (MWI) diagnostic, we present the installation of a multi-delay coherence imaging spectroscopy (CIS) system within the MAST-U MWI, along with modifications made to the MWI for effective operation. This diagnostic will measure either carbon ion flow velocities and temperatures or electron densities through Dγ emission. We have extended previously developed techniques for wavelength calibration to account for errors due to the misalignment of interferometer components. In addition, we have developed a comprehensive calibration procedure to account for the temperature dependence of the instrument's delays by fitting to a linearly modified version of the delay equation presented by Veiras et al. [Appl. Opt. 49(15), 2769 (2010)]. Together, these procedures reduce the cost and hardware complexity of implementing CIS instruments when compared to those that use in situ or tunable laser calibration systems, as calibrations can be generated to good accuracy using previously measured data.

2.
Rev Sci Instrum ; 92(7): 073506, 2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-34340444

RESUMO

In this paper, the pixelated phase mask (PPM) method of interferometry is applied to coherence imaging (CI)-a passive, narrowband spectral imaging technique for diagnosing the edge and divertor regions of fusion plasma experiments. Compared to previous CI designs that use a linear phase mask, the PPM method allows for a higher possible spatial resolution. The PPM method is also observed to give a higher instrument contrast (analogous to a more narrow spectrometer instrument function). A single-delay PPM instrument is introduced as well as a multi-delay system that uses a combination of both pixelated and linear phase masks to encode the coherence of the observed radiation at four different interferometer delays simultaneously. The new methods are demonstrated with measurements of electron density ne, via Stark broadening of the Hγ emission line at 434.0 nm, made on the Magnum-PSI linear plasma experiment. A comparison of the Abel-inverted multi-delay CI measurements with Thomson scattering shows agreement across the 3 × 1019 < ne < 1 × 1021 m-3 range. For the single-delay CI results, agreement is found for ne > 1 × 1020 m-3 only. Accurate and independent interpretation of single-delay CI data at lower ne was not possible due to Doppler broadening and continuum emission.

3.
Rev Sci Instrum ; 92(6): 063510, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243542

RESUMO

Divertor detachment and alternative divertor magnetic geometries are predicted to be promising approaches to handle the power exhaust of future fusion devices. In order to understand the detachment process caused by volumetric losses in alternative divertor magnetic geometries, a Multi-Wavelength Imaging (MWI) diagnostic has recently been designed and built for the Mega Amp Spherical Tokamak Upgrade. The MWI diagnostic will simultaneously capture 11 spectrally filtered images of the visible light emitted from divertor plasmas and provide crucial knowledge for the interpretation of observations and modeling efforts. This paper presents the optical design, mechanical design, hardware, and test results of an 11-channel MWI system with a field of view of 40°. The optical design shows better than 5 mm FWHM spatial resolution at the plasma on all 11 channels across the whole field of view. The spread of angle of incidence on the surface of each filter is also analyzed to inform the bandwidth specification of the interference filters. The results of the initial laboratory tests demonstrate that a spatial resolution of better than 5 mm FWHM is achieved for all 11 channels, meeting the specifications required for accurate tomography.

4.
Rev Sci Instrum ; 91(8): 083504, 2020 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-32872906

RESUMO

A new Doppler coherence imaging spectroscopy interferometer has been developed on the HL-2A tokamak for the scrape-off-layer impurity flow measurement. Its spatial resolution is estimated to be up to ∼0.8 mm in the horizontal direction and ∼9 mm in the vertical direction, with a field of view of ∼34°. Its typical temporal resolution is about 1 ms. This salient feature allows for time-resolved 2D measurements in short-time phenomena on HL-2A, such as edge localized modes. Group delay and interference fringe pattern were calibrated with a dedicated calibration system. The robustness of group delay calibration and the feasibility of the extrapolation model for fringe pattern calibration are demonstrated. In this paper, we report the details of the optical instruments, calibration, and the initial experimental results of this Doppler coherence imaging spectroscopy interferometer.