Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Dent Mater J ; 34(1): 13-8, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25748453

RESUMO

Radiopacity is an important property of composite materials for clinical diagnosis. For seven direct composites (Aelite LS Posterior, Aelite All-Purpose Body, Quadrant Universal LC, Clearfil Majesty Posterior, Clearfil Majesty Esthetic, Filtek Ultimate Dentin, IPS Empress Direct Dentin) and six indirect composites (Ceromega, Epricord, Estenia C&B, Tescera, Signum Ceramis, Solidex), diskshaped specimens (N=260, n=10 per group) were fabricated for two thicknesses at 1 and 2 mm. Average radiographic density of each composite material was calculated. Radiopacity values of specimens were expressed in equivalent thickness of aluminum using the calibration curve. Data were analyzed using one-way and two-way ANOVA, followed by Tukey's HSD test (α=0.05). Radiopacity was significantly affected by resin composite type (p<0.05) and thickness (p<0.001). All composites, except Epricord (1.22-1.84), had higher radiopacity values than dentin (1.23-2.24). IPS Empress Direct (5.58-9.38) and Estenia C&B (5.49-9.16) showed significantly higher radiopacity (p<0.05) than the other materials including enamel and dentin.


Assuntos
Resinas Compostas/química , Materiais Dentários/química , Radiografia Dentária , Silicatos de Alumínio/química , Porcelana Dentária/química , Dentina/diagnóstico por imagem , Teste de Materiais , Metacrilatos/química , Poliuretanos/química , Intensificação de Imagem Radiográfica , Propriedades de Superfície
2.
J Indian Prosthodont Soc ; 14(Suppl 1): 196-201, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26199515

RESUMO

The loss or absence of an auricle may result from trauma, disease or congenital anomalies and causes a considerable aesthetic problem. If the deformity involves the external auditory canal, it can affect hearing. This case report describes the surgical and prosthetic treatment of two patients with partial defects of their right external ears from different causes. Implant-retained auricular prostheses fabricated from heat-temperature-vulcanised silicone were used in both the cases; they were designed to be harmonious with the remaining tissues. The patients experienced improved retention, aesthetics, hearing and quality of life with these prostheses. During the approximately 3 year follow-up, both the prostheses were re-fabricated once; however, problems related to implant stability and peri-implant tissue health were not encountered.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA