Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Immunother Cancer ; 8(2)2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33188037

RESUMO

BACKGROUND: Combining radiotherapy (RT) with immuno-oncology (IO) therapy (IORT) may enhance IO-induced antitumor response. Quantitative imaging biomarkers can be used to provide prognosis, predict tumor response in a non-invasive fashion and improve patient selection for IORT. A biologically inspired CD8 T-cells-associated radiomics signature has been developed on previous cohorts. We evaluated here whether this CD8 radiomic signature is associated with lesion response, whether it may help to assess disease spatial heterogeneity for predicting outcomes of patients treated with IORT. We also evaluated differences between irradiated and non-irradiated lesions. METHODS: Clinical data from patients with advanced solid tumors in six independent clinical studies of IORT were investigated. Immunotherapy consisted of 4 different drugs (antiprogrammed death-ligand 1 or anticytotoxic T-lymphocyte-associated protein 4 in monotherapy). Most patients received stereotactic RT to one lesion. Irradiated and non-irradiated lesions were delineated from baseline and the first evaluation CT scans. Radiomic features were extracted from contrast-enhanced CT images and the CD8 radiomics signature was applied. A responding lesion was defined by a decrease in lesion size of at least 30%. Dispersion metrices of the radiomics signature were estimated to evaluate the impact of tumor heterogeneity in patient's response. RESULTS: A total of 94 patients involving multiple lesions (100 irradiated and 189 non-irradiated lesions) were considered for a statistical interpretation. Lesions with high CD8 radiomics score at baseline were associated with significantly higher tumor response (area under the receiving operating characteristic curve (AUC)=0.63, p=0.0020). Entropy of the radiomics scores distribution on all lesions was shown to be associated with progression-free survival (HR=1.67, p=0.040), out-of-field abscopal response (AUC=0.70, p=0.014) and overall survival (HR=2.08, p=0.023), which remained significant in a multivariate analysis including clinical and biological variables. CONCLUSIONS: These results enhance the predictive value of the biologically inspired CD8 radiomics score and suggests that tumor heterogeneity should be systematically considered in patients treated with IORT. This CD8 radiomics signature may help select patients who are most likely to benefit from IORT.


Assuntos
Linfócitos T CD8-Positivos/metabolismo , Imunoterapia/métodos , Neoplasias/tratamento farmacológico , Neoplasias/radioterapia , Radioterapia (Especialidade)/métodos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Microambiente Tumoral
2.
Sci Rep ; 10(1): 12340, 2020 07 23.
Artigo em Inglês | MEDLINE | ID: mdl-32704007

RESUMO

Radiomics relies on the extraction of a wide variety of quantitative image-based features to provide decision support. Magnetic resonance imaging (MRI) contributes to the personalization of patient care but suffers from being highly dependent on acquisition and reconstruction parameters. Today, there are no guidelines regarding the optimal pre-processing of MR images in the context of radiomics, which is crucial for the generalization of published image-based signatures. This study aims to assess the impact of three different intensity normalization methods (Nyul, WhiteStripe, Z-Score) typically used in MRI together with two methods for intensity discretization (fixed bin size and fixed bin number). The impact of these methods was evaluated on first- and second-order radiomics features extracted from brain MRI, establishing a unified methodology for future radiomics studies. Two independent MRI datasets were used. The first one (DATASET1) included 20 institutional patients with WHO grade II and III gliomas who underwent post-contrast 3D axial T1-weighted (T1w-gd) and axial T2-weighted fluid attenuation inversion recovery (T2w-flair) sequences on two different MR devices (1.5 T and 3.0 T) with a 1-month delay. Jensen-Shannon divergence was used to compare pairs of intensity histograms before and after normalization. The stability of first-order and second-order features across the two acquisitions was analysed using the concordance correlation coefficient and the intra-class correlation coefficient. The second dataset (DATASET2) was extracted from the public TCIA database and included 108 patients with WHO grade II and III gliomas and 135 patients with WHO grade IV glioblastomas. The impact of normalization and discretization methods was evaluated based on a tumour grade classification task (balanced accuracy measurement) using five well-established machine learning algorithms. Intensity normalization highly improved the robustness of first-order features and the performances of subsequent classification models. For the T1w-gd sequence, the mean balanced accuracy for tumour grade classification was increased from 0.67 (95% CI 0.61-0.73) to 0.82 (95% CI 0.79-0.84, P = .006), 0.79 (95% CI 0.76-0.82, P = .021) and 0.82 (95% CI 0.80-0.85, P = .005), respectively, using the Nyul, WhiteStripe and Z-Score normalization methods compared to no normalization. The relative discretization makes unnecessary the use of intensity normalization for the second-order radiomics features. Even if the bin number for the discretization had a small impact on classification performances, a good compromise was obtained using the 32 bins considering both T1w-gd and T2w-flair sequences. No significant improvements in classification performances were observed using feature selection. A standardized pre-processing pipeline is proposed for the use of radiomics in MRI of brain tumours. For models based on first- and second-order features, we recommend normalizing images with the Z-Score method and adopting an absolute discretization approach. For second-order feature-based signatures, relative discretization can be used without prior normalization. In both cases, 32 bins for discretization are recommended. This study may pave the way for the multicentric development and validation of MR-based radiomics biomarkers.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Glioma/diagnóstico por imagem , Imageamento por Ressonância Magnética/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
3.
Int J Radiat Oncol Biol Phys ; 108(3): 813-823, 2020 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-32417412

RESUMO

PURPOSE: This study aims to evaluate the impact of key parameters on the pseudo computed tomography (pCT) quality generated from magnetic resonance imaging (MRI) with a 3-dimensional (3D) convolutional neural network. METHODS AND MATERIALS: Four hundred two brain tumor cases were retrieved, yielding associations between 182 computed tomography (CT) and T1-weighted MRI (T1) scans, 180 CT and contrast-enhanced T1-weighted MRI (T1-Gd) scans, and 40 CT, T1, and T1-Gd scans. A 3D CNN was used to map T1 or T1-Gd onto CT scans and evaluate the importance of different components. First, the training set size's influence on testing set accuracy was assessed. Moreover, we evaluated the MRI sequence impact, using T1-only and T1-Gd-only cohorts. We then investigated 4 MRI standardization approaches (histogram-based, zero-mean/unit-variance, white stripe, and no standardization) based on training, validation, and testing cohorts composed of 242, 81, and 79 patients cases, respectively, as well as a bias field correction influence. Finally, 2 networks, namely HighResNet and 3D UNet, were compared to evaluate the architecture's impact on the pCT quality. The mean absolute error, gamma indices, and dose-volume histograms were used as evaluation metrics. RESULTS: Generating models using all the available cases for training led to higher pCT quality. The T1 and T1-Gd models had a maximum difference in gamma index means of 0.07 percentage point. The mean absolute error obtained with white stripe was 78 ± 22 Hounsfield units, which slightly outperformed histogram-based, zero-mean/unit-variance, and no standardization (P < .0001). Regarding the network architectures, 3%/3 mm gamma indices of 99.83% ± 0.19% and 99.74% ± 0.24% were obtained for HighResNet and 3D UNet, respectively. CONCLUSIONS: Our best pCTs were generated using more than 200 samples in the training data set. Training with T1 only and T1-Gd only did not significantly affect performance. Regardless of the preprocessing applied, the dosimetry quality remained equivalent and relevant for potential use in clinical practice.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Aprendizado Profundo , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Encéfalo/diagnóstico por imagem , Neoplasias Encefálicas/radioterapia , Meios de Contraste , Humanos , Imageamento por Ressonância Magnética/normas , Redes Neurais de Computação , Radiometria , Radioterapia/normas , Estudos Retrospectivos , Crânio/diagnóstico por imagem
4.
Front Comput Neurosci ; 14: 17, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32265680

RESUMO

Image registration and segmentation are the two most studied problems in medical image analysis. Deep learning algorithms have recently gained a lot of attention due to their success and state-of-the-art results in variety of problems and communities. In this paper, we propose a novel, efficient, and multi-task algorithm that addresses the problems of image registration and brain tumor segmentation jointly. Our method exploits the dependencies between these tasks through a natural coupling of their interdependencies during inference. In particular, the similarity constraints are relaxed within the tumor regions using an efficient and relatively simple formulation. We evaluated the performance of our formulation both quantitatively and qualitatively for registration and segmentation problems on two publicly available datasets (BraTS 2018 and OASIS 3), reporting competitive results with other recent state-of-the-art methods. Moreover, our proposed framework reports significant amelioration (p < 0.005) for the registration performance inside the tumor locations, providing a generic method that does not need any predefined conditions (e.g., absence of abnormalities) about the volumes to be registered. Our implementation is publicly available online at https://github.com/TheoEst/joint_registration_tumor_segmentation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...