Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Glaucoma ; 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38767514

RESUMO

PRCIS: Ahmed Glaucoma valve implantation by residents showed similar complications, success, and failure rates, regardless of their level of expertise. Training programs must encourage ophthalmologists to perform this surgery to enhance competence in their future practices. PURPOSE: To describe outcomes of resident-performed Ahmed Valve implantation over a 5-year period. METHODS: In this cross-sectional observational study we retrospectively reviewed the medical records of patients who underwent resident-performed Ahmed Glaucoma Valve implantation over a 5-year period. The main outcomes were the number of surgeries performed by first, second, and third-year residents, intraoperative and postoperative complications, and the association of level of training with outcomes and complications. RESULTS: 160 eyes were included, with a mean age of 53.8±15.4 years, 63% were men. The most frequent type of glaucoma was neovascular glaucoma (67.5%). Mean follow-up was 23.2±19.6 months. Residents of higher years performed more surgeries and no relationship was found between the surgeon's level of training and type of glaucoma operated on. After the surgical procedure, significant changes in best-corrected visual acuity were noted in surgeries performed by third-year residents (P=0.04). Intraocular pressure and number of medications were significantly reduced in all groups (P=0.01). Complications were registered in 60 eyes; the most frequent being the presence of a transient flat anterior chamber (27.45%). CONCLUSIONS: There were no significant differences in terms of IOP control and the number of complications in the three groups. There was no significant association between the resident's experience and the outcomes of the surgery. The Ahmed valve implant is a procedure that appears to have similar results in surgeons with different levels of training.

2.
Indian J Ophthalmol ; 71(5): 1966-1971, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37203066

RESUMO

Purpose: To evaluate the prevalence of hypertensive phase (HP) and failure in patients who underwent Ahmed Glaucoma Valve (AGV) implantation and identify the possible risk factors for both HP and failure. Methods: A cross-sectional, observational study was conducted. Medical records of patients who underwent AGV implantation and had at least 1 year of follow-up were reviewed. HP was defined as an intraocular pressure (IOP) greater than 21 mmHg between the first week and the third postoperative month not attributable to other causes. Success was defined as an IOP between 6 and 21 mmHg, with preservation of light perception and no additional glaucoma surgeries. Statistical analysis was conducted to identify possible risk factors. Results: A total of 193 eyes of 177 patients were included. HP was present in 58%; a higher preoperative IOP and younger age were associated with HP. Pseudophakic or aphakic eyes had a lower HP rate. Failure was present in 29%; neovascular glaucoma, worse basal best corrected visual acuity (BCVA), higher baseline IOP, and postoperative complications were linked to a higher likelihood of failure. No difference in the HP rate between the failure and success groups was found. Conclusion: A higher baseline IOP and younger age are associated with HP development; pseudophakia and aphakia might be protective factors. Factors for AGV failure are a worse BCVA, neovascular glaucoma, postoperative complications, and a higher baseline IOP. At 1 year, a higher number of medications were needed to achieve IOP control in the HP group.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma Neovascular , Glaucoma , Humanos , Seguimentos , Glaucoma Neovascular/cirurgia , Prevalência , Estudos Transversais , Resultado do Tratamento , Implantação de Prótese , Glaucoma/epidemiologia , Glaucoma/cirurgia , Glaucoma/tratamento farmacológico , Pressão Intraocular , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/cirurgia , Fatores de Risco , Estudos Retrospectivos
3.
Int J Ophthalmol ; 15(10): 1707-1713, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36262847

RESUMO

AIM: To report the long-term outcomes of combined excisional goniotomy and manual small incision cataract surgery (MSICS). METHODS: This is a retrospective case series of patients with open angle glaucoma and visually significant cataracts that underwent combined excisional goniotomy and MSICS with one-year follow-up. The medical history, demographic information, and clinical characteristics of each case were recorded. Data regarding changes in vision, intraocular pressure (IOP), the number of glaucoma medications, and the evolution of the disease after surgery were reported. RESULTS: Three patients, with open angle glaucoma and cataracts underwent combined excisional goniotomy and MSICS without adverse events. All patients had improvement in vision compared to baseline measurements. The range of IOP at baseline was from 14 to 18 mm Hg and decrease to a range of 10 to 14 mm Hg after one year of follow-up. Additionally, two patients also decreased their dependence on IOP-lowering medications at the last follow up visit with one patient maintaining baseline level of medication use. CONCLUSION: A combination of excisional goniotomy and MSICS illustrates both the safety and efficacy to treat patients with visually significant cataract and glaucoma. This procedure allows for a more cost-effective surgical approach that matches the needs of resource strained territories around the globe.

4.
Int J Ophthalmol ; 15(6): 990-996, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35814902

RESUMO

AIM: To assess and compare knowledge and awareness of glaucoma in subjects with and without glaucoma diagnosis attending an Ophthalmology Referral Center. METHODS: This cross-sectional study was conducted at Asociación Para Evitar la Ceguera in Mexico City, using a questionnaire formulated by a group of experts following the Delphi panel rules, and pre-tested in a pilot study. The questionnaire was applied and compared between: glaucoma patients, relatives of glaucoma patients and patients without glaucoma. Socio-demographic data was collected to assess correlation with the level of knowledge using Logistic regression models, estimating the odds ratios (OR), 95% confidence intervals, and P<0.05. RESULTS: Three hundred and ninety-four subjects were enrolled; with a median age of 61y. One hundred and thirty-four (34%) were patients with glaucoma, 152 (38.6%) patients without glaucoma, and 108 (27.4%) relatives of patients with glaucoma. Two hundred and ninety-one (73.9%) participants were aware of the term "glaucoma". Regarding knowledge 46.7% had moderate knowledge, 37.8% had poor knowledge, and 15.5% good knowledge. Overall, relatives of glaucoma patients had the highest scores, and patients without glaucoma got the lowest scores. A positive correlation was found between better knowledge and frequent ophthalmological examinations OR 2.24 (P=0.02), higher education level OR 4.17 (P=0.00) and having a family member with glaucoma OR 3.28 (P=0.00). CONCLUSION: Awareness and knowledge of glaucoma in subjects attending an Ophthalmology Referral Center is predominantly moderate or poor. This has important implications regarding attitudes that can result in lack of follow up in ophthalmological care.

5.
Am J Ophthalmol Case Rep ; 23: 101163, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34307963

RESUMO

PURPOSE: To assess the short and long-term changes in Visual Field (VF) Mean Deviation (MD), Visual Field Index (VFI), and intraocular pressure (IOP) after femtosecond laser-assisted cataract surgery (FLACS) in glaucomatous eyes. MATERIALS AND METHODS: Interventional, prospective case series. Patients with glaucoma, who required cataract surgery were included. All patients underwent a complete ophthalmologic assessment and Visual Fields. FLACS was performed in all patients by a single experienced surgeon. IOP was measured during surgery immediately before and after pretreatment suction docking. Changes from baseline in VF MD and VFI, IOP, visual acuity (VA), and number of glaucoma medications were evaluated up to one-year follow-up. RESULTS: Fourteen eyes of 11 patients were included. Eighty-five percent were female, with a mean age of 74.2 ± 7.9 years. Nine (64.3%) and 5 (35.7%) were diagnosed with primary angle closure glaucoma (PACG) and primary open angle glaucoma (POAG), respectively. We found a slight IOP reduction after the docking phase during FLACS in both glaucoma subtype groups. No significant changes in visual field mean deviation (MD) and visual field index (VFI) were found from baseline to 12 months after surgery in both groups. A significant reduction in IOP values was found in all cases from baseline up to one year follow up. No significant changes were observed in BCVA and number of topical glaucoma medications after one year in both groups. CONCLUSION: In our patients, there was an IOP reduction immediately after suction docking FLACS pretreatment. Mean IOP at final follow-up showed a reduction from baseline. There was no change in VF MD and VFI from baseline to final one-year follow-up. FLACS appears to be well tolerated in early and moderate glaucoma and appears to be a safe tool for glaucoma patients undergoing cataract surgery. Similar results to traditional surgery can be obtained with the advantages of femtosecond laser precision.

6.
J Glaucoma ; 30(4): e180-e183, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33394850

RESUMO

PRECIS: Surgeons that perform cataract surgery combined with endocyclophotocoagulation (ECP) should rely on their preferred intraocular lens (IOL) calculation formula. There is no need to perform any correction to the IOL power, as this procedure does not modify the refractive outcome. PURPOSE: The purpose of this study was to compare postoperative refractive outcomes in patients with glaucoma who underwent phacoemulsification and IOL implantation with or without ECP and the change in intraocular pressure (IOP) and number of antiglaucoma medications between groups. METHODS: A cross-sectional study in which the medical records of the patients with any type of glaucoma, who underwent phacoemulsification with IOL implantation in the capsular bag in addition to ECP or as a standalone procedure from June 2016 to August 2019 were analyzed. Clinical data collected included axial length, steep, flat, and mean keratometry values, target spherical equivalent (SE) estimated by the SRK/T formula, manifest refraction SE at the 1-month follow-up, IOP, and number of antiglaucoma medications before and 12 months after surgery. Primary and secondary outcome measures were the mean predictive error (MPE), the postoperative SE, and the change in IOP after surgery in both groups, respectively. Significance was assessed using the Student t test for all variables between groups according to data distribution. P-values <0.05 were considered to be statistically significant. RESULTS: A total of 196 eyes of 196 patients were included, 98 in the combined phacoemulsification-ECP group, and 98 in the non-ECP group. The observed MPE was -0.043±0.44, and 0.06±0.38 D MPE, respectively (P=0.079). Overall, 74.34% in the phacoemulsification-ECP group and 78.4% in the non-ECP group had a postoperative SE of ±0.50. The ECP group had lower IOP and a greater decrease in antiglaucoma medications at 12 months of follow-up. CONCLUSIONS: SRK/T formula performed well in both groups, with no statistically significant difference in the MPE and the percentage of eyes achieving postoperative SE of ±0.50. We consider it is unnecessary to perform any kind of correction to the IOL power calculation when performing ECP.


Assuntos
Catarata , Lentes Intraoculares , Facoemulsificação , Biometria , Catarata/complicações , Estudos Transversais , Humanos , Pressão Intraocular , Implante de Lente Intraocular , Refração Ocular , Estudos Retrospectivos
7.
J Glaucoma ; 30(8): e367-e371, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33394854

RESUMO

PURPOSE: To report our experience using a Tenon cyst autograft in the management of tube exposure post Ahmed glaucoma valve (AGV) implantation. METHODS: This is a retrospective case series. RESULTS: Four patients who underwent tube exposure repair using Tenon cyst autograft were identified in our tertiary care center. The duration between initial AGV implantation and tube exposure ranged between 3 and 36 months with a mean of 16 months (±14.35 mo). All patients were followed postoperatively for a range of 4 to 24 months with a mean of 11.75 months (±9.03 o) and all remain exposure free at last follow-up. CONCLUSION: The use of a Tenon cyst autograft for the surgical repair of a tube exposure is valuable, as it involves using autologous scar tissue that is available in eyes that have undergone AGV implantation. The patch autograft is technically easy to harvest, and represents a significantly lower cost when compared with other available options.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma , Seguimentos , Glaucoma/cirurgia , Humanos , Pressão Intraocular , Complicações Pós-Operatórias , Implantação de Prótese , Estudos Retrospectivos , Resultado do Tratamento
9.
J Curr Glaucoma Pract ; 11(3): 97-100, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29151684

RESUMO

AIM: To determine the glaucoma specialists' preferences for the different brands of topical glaucoma medications available in Mexico. MATERIALS AND METHODS: A web-based survey was sent to 150 board-certified glaucoma specialists in Mexico, with 14 questions related to brand preferences for all glaucoma medications available in Mexico. Participants were asked to select each glaucoma medication class by brand and to state the factors leading to their choice. RESULTS: Data from 111 (74%) glaucoma specialists were collected. Imot (timolol 0.5%; Sophia, Mexico) was the preferred brand for the beta-blockers (BB) class by 71% (n = 79) of the participants. Azopt (brinzolamide 1%; Alcon Lab, US) was the preferred carbonic anhydrase inhibitor (CAI) by 54% (n = 60) of the glaucoma specialists. Lumigan (bimatoprost 0.01% and 0.03%; Allergan Inc., U.S.) was the first choice for the prostaglandin analogues (PGAs) in 62% (n = 70) of the answers. The most frequently prescribed alpha-agonist (AA) was Agglad (brimonidine 0.2%; Sophia Lab, Mexico) in 44% (n = 49) of the answers. Medication accessibility (31%), cost (29%), and recommended dose (23%) were the three main factors influencing the glaucoma specialists' preferences. CONCLUSION: Medication cost and accessibility, as well as posology, remain the main factors influencing brand preferences among glaucoma doctors. In our professional opinion, the therapeutic effect must be the leading factor when prescribing topical medications in the daily practice, so that patients receive the best treatment option. CLINICAL SIGNIFICANCE: This survey provides an understanding of the decision-making process when prescribing glaucoma medications by glaucoma specialists in a Latin American developing country. Ideally, patient treatment should be individualized and aimed to achieve the best results possible for their specific condition.How to cite this article: Lazcano-Gomez G, Alvarez-Ascencio D, Haro-Zuno C, Turati-Acosta M, Garcia-Huerta M, Jimenez-Arroyo J, Castañeda-Diez R, Castillejos-Chevez A, Gonzalez-Salinas R, Dominguez-Dueñas F, Jimenez-Roman J. Glaucoma Medication Preferences among Glaucoma Specialists in Mexico. J Curr Glaucoma Pract 2017;11(3):97-100.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...