1.
Magn Reson Med ; 76(5): 1431-1442, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-26599411

RESUMO

PURPOSE: Standard radiofrequency pulse design strategies focus on minimizing the deviation of the flip angle from a target value, which is sufficient but not necessary for signal homogeneity. An alternative approach, based directly on the signal, here is proposed for the MPRAGE sequence, and is developed in the parallel transmission framework with the use of the kT -points parametrization. METHODS: The flip angle-homogenizing and the proposed methods were investigated numerically under explicit power and specific absorption rate constraints and tested experimentally in vivo on a 7 T parallel transmission system enabling real time local specific absorption rate monitoring. Radiofrequency pulse performance was assessed by a careful analysis of the signal and contrast between white and gray matter. RESULTS: Despite a slight reduction of the flip angle uniformity, an improved signal and contrast homogeneity with a significant reduction of the specific absorption rate was achieved with the proposed metric in comparison with standard pulse designs. CONCLUSION: The proposed joint optimization of the inversion and excitation pulses enables significant reduction of the specific absorption rate in the MPRAGE sequence while preserving image quality. The work reported thus unveils a possible direction to increase the potential of ultra-high field MRI and parallel transmission. Magn Reson Med 76:1431-1442, 2016. © 2015 International Society for Magnetic Resonance in Medicine.


Assuntos
Algoritmos , Encéfalo/anatomia & histologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Processamento de Sinais Assistido por Computador , Humanos , Ondas de Rádio , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
IEEE Trans Med Imaging ; 33(3): 739-48, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24595346

RESUMO

Parallel transmission is a very promising candidate technology to mitigate the inevitable radio-frequency (RF) field inhomogeneity in magnetic resonance imaging at ultra-high field. For the first few years, pulse design utilizing this technique was expressed as a least squares problem with crude power regularizations aimed at controlling the specific absorption rate (SAR), hence the patient safety. This approach being suboptimal for many applications sensitive mostly to the magnitude of the spin excitation, and not its phase, the magnitude least squares (MLS) problem then was first formulated in 2007. Despite its importance and the availability of other powerful numerical optimization methods, the MLS problem yet has been faced almost exclusively by the pulse designer with the so-called variable exchange method. In this paper, we investigate various two-stage strategies consisting of different initializations and nonlinear programming approaches, and incorporate directly the strict SAR and hardware constraints. Several schemes such as sequential quadratic programming, interior point methods, semidefinite programming and magnitude squared least squares relaxations are studied both in the small and large tip angle regimes with RF and static field maps obtained in vivo on a human brain at 7T. Convergence and robustness of the different approaches are analyzed, and recommendations to tackle this specific problem are finally given. Small tip angle and inversion pulses are returned in a few seconds and in under a minute respectively while respecting the constraints, allowing the use of the proposed approach in routine.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Processamento de Sinais Assistido por Computador , Absorção , Encéfalo/anatomia & histologia , Cabeça/anatomia & histologia , Humanos , Análise dos Mínimos Quadrados , Modelos Biológicos , Ondas de Rádio
3.
Neuroimage ; 62(3): 2140-50, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22659484

RESUMO

One of the promises of Ultra High Field (UHF) MRI scanners is to bring finer spatial resolution in the human brain images due to an increased signal to noise ratio. However, at such field strengths, the spatial non-uniformity of the Radio Frequency (RF) transmit profiles challenges the applicability of most MRI sequences, where the signal and contrast levels strongly depend on the flip angle (FA) homogeneity. In particular, the MP-RAGE sequence, one of the most commonly employed 3D sequences to obtain T1-weighted anatomical images of the brain, is highly sensitive to these spatial variations. These cause deterioration in image quality and complicate subsequent image post-processing such as automated tissue segmentation at UHF. In this work, we evaluate the potential of parallel-transmission (pTx) to obtain high-quality MP-RAGE images of the human brain at 7 T. To this end, non-selective transmit-SENSE pulses were individually tailored for each of 8 subjects under study, and applied to an 8-channel transmit-array. Such RF pulses were designed both for the low-FA excitation train and the 180° inversion preparation involved in the sequence, both utilizing the recently introduced k(T)-point trajectory. The resulting images were compared with those obtained from the conventional method and from subject-specific RF-shimmed excitations. In addition, four of the volunteers were scanned at 3 T for benchmarking purposes (clinical setup without pTx). Subsequently, automated tissue classification was performed to provide a more quantitative measure of the final image quality. Results indicated that pTx could already significantly improve image quality at 7 T by adopting a suitable RF-Shim. Exploiting the full potential of the pTx-setup, the proposed k(T)-point method provided excellent inversion fidelity, comparable to what is commonly only achievable at 3 T with energy intensive adiabatic pulses. Furthermore, the cumulative energy deposition was simultaneously reduced by over 40% compared to the conventional adiabatic inversions. Regarding the low-FA k(T)-point based excitations, the FA uniformity achieved at 7 T surpassed what is typically obtained at 3 T. Subsequently, automated white and gray matter segmentation not only confirmed the expected improvements in image quality, but also suggests that care should be taken to properly account for the strong local susceptibility effects near cranial cavities. Overall, these findings indicate that the k(T)-point-based pTx solution is an excellent candidate for UHF 3D imaging, where patient safety is a major concern due to the increase of specific absorption rates.


Assuntos
Mapeamento Encefálico/métodos , Encéfalo/anatomia & histologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Algoritmos , Encéfalo/fisiologia , Mapeamento Encefálico/instrumentação , Humanos , Imageamento por Ressonância Magnética/instrumentação
4.
Magn Reson Med ; 67(1): 72-80, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21590724

RESUMO

With Transmit SENSE, we demonstrate the feasibility of uniformly exciting a volume such as the human brain at 7T through the use of an original minimalist transmit k-space coverage, referred to as "k(T) -points." Radio-frequency energy is deposited only at a limited number of k-space locations in the vicinity of the center to counteract transmit sensitivity inhomogeneities. The resulting nonselective pulses are short and need little energy compared to adiabatic or other B 1+-robust pulses available in the literature, making them good candidates for short-repetition time 3D sequences at high field. Experimental verification was performed on three human volunteers at 7T by means of an 8-channel transmit array system. On average, whereas the standard circularly polarized excitation resulted in a 33%-flip angle spread (standard deviation over mean) throughout the brain, and a static radio-frequency shim showed flip angle variations of 17% and up, application of k(T) -point-based excitations demonstrated excellent flip angle uniformity (8%) for a small target flip angle and with sub-millisecond durations.


Assuntos
Algoritmos , Encéfalo/anatomia & histologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Reconhecimento Automatizado de Padrão/métodos , Humanos , Aumento da Imagem/métodos , Tamanho do Órgão , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Magn Reson Med ; 65(3): 680-91, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20949589

RESUMO

A novel method based on average Hamiltonian theory to design selective pulses is reported. With this tool, it is first shown how to shape the radiofrequency and gradient pulses to generate a desired rotation matrix, which is independent of the position through the slice of interest. After theoretical examination of the concept, it is applied to the strongly modulating pulses' recipe developed by the same authors and initially designed to be nonselective, to mitigate the amplitude of (excitation) radiofrequency field and amplitude of static (polarizing) field inhomogeneity problems at high field. Two in vivo human brain imaging experiments at 7 T are reported to prove the validity of the technique.


Assuntos
Algoritmos , Artefatos , Encéfalo/anatomia & histologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador
6.
Magn Reson Med ; 61(5): 1165-72, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19253378

RESUMO

We report flip angle and spoiled gradient echo measurements at 7 Tesla on human brains in three-dimensional imaging, using strongly modulating pulses to counteract the transmitted radiofrequency inhomogeneity problem. Compared with the standard square pulse results, three points of improvement are demonstrated, namely: (i) the removal of the bright center (typical at high fields when using a quadrature head coil), (ii) the substantial gain of signal in the regions of low B(1) intensity, and (iii) an increased 35% signal uniformity over the whole brain at the flip angle where maximum contrast between white and gray matter occurs. We also find by means of simulations that standard BIR-4 adiabatic pulses need several times more energy to reach a similar performance at the same field strength.


Assuntos
Algoritmos , Artefatos , Encéfalo/anatomia & histologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Anisotropia , Humanos , Ondas de Rádio , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Psychopharmacology (Berl) ; 202(4): 599-610, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18818904

RESUMO

RATIONALE: The behavioral effects of nicotine and the role of the beta2-containing nicotinic receptors in these behaviors are well documented. However, the behaviors altered by nicotine rely on the functioning on multiple brain circuits where the high-affinity beta2-containing nicotinic receptors (beta2*nAChRs) are located. OBJECTIVES: We intend to see which brain circuits are activated when nicotine is given in animals naïve for nicotine and whether the beta2*nAChRs are needed for its activation of the blood oxygen level dependent (BOLD) signal in all brain areas. MATERIALS AND METHODS: We used functional magnetic resonance imaging (fMRI) to measure the brain activation evoked by nicotine (1 mg/kg delivered at a slow rate for 45 min) in anesthetized C57BL/6J mice and beta2 knockout (KO) mice. RESULTS: Acute nicotine injection results in a significant increased activation in anterior frontal, motor, and somatosensory cortices and in the ventral tegmental area and the substantia nigra. Anesthetized mice receiving no nicotine injection exhibited a major decreased activation in all cortical and subcortical structures, likely due to prolonged anesthesia. At a global level, beta2 KO mice were not rescued from the globally declining BOLD signal. However, nicotine still activated regions of a meso-cortico-limbic circuit likely via alpha7 nicotinic receptors. CONCLUSIONS: Acute nicotine exposure compensates for the drop in brain activation due to anesthesia through the meso-cortico-limbic network via the action of nicotine on beta2*nAChRs. The developed fMRI method is suitable for comparing responses in wild-type and mutant mice.


Assuntos
Encéfalo/efeitos dos fármacos , Estimulantes do Sistema Nervoso Central , Nicotina/farmacologia , Agonistas Nicotínicos/farmacologia , Receptores Nicotínicos/genética , Receptores Nicotínicos/fisiologia , Anestesia , Animais , Química Encefálica/efeitos dos fármacos , Desenho de Equipamento , Injeções Subcutâneas , Imageamento por Ressonância Magnética/instrumentação , Masculino , Camundongos , Camundongos Knockout , Oxigênio/sangue , Receptores Nicotínicos/efeitos dos fármacos , Estimulação Química
8.
Magn Reson Med ; 60(3): 701-8, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18727086

RESUMO

A new pulse technique for counteracting RF inhomogeneity at high fields is reported. The pulses make use of the detailed knowledge of the voxels' B(1) and B(0) amplitude 2D histogram to generate, through an optimization procedure, gates where the flip angle is made uniform. Although most approaches to date require the use of parallel transmission, this method does not and therefore offers several advantages. The data necessary for the algorithm to determine an irradiation scheme requires only one transmit B(1) along with a B(0) inhomogeneity measurement. The use of a B(1) and B(0) amplitude 2D histogram instead of their spatial distribution also decreases substantially the complexity of the optimization problem, allowing the algorithm to find an RF solution in less than 30 s. Finally, the optimization procedure is based on an exact calculation and does not use any linear approximation. In this article, the theory behind the method in addition to spoiled gradient echo experimental data at 3T for 3D brain imaging are reported. The images obtained yield a reduction of the standard deviation of the sine of the flip angle by a factor of up to 15 around the desired value, compared to when a standard square pulse calibrated by the scanner is used.


Assuntos
Imageamento por Ressonância Magnética/métodos , Algoritmos , Encéfalo/anatomia & histologia , Humanos , Ondas de Rádio