1.
MAGMA ; 37(2): 169-183, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38197908

RESUMO

OBJECTIVE: To assess the possible influence of third-order shim coils on the behavior of the gradient field and in gradient-magnet interactions at 7 T and above. MATERIALS AND METHODS: Gradient impulse response function measurements were performed at 5 sites spanning field strengths from 7 to 11.7 T, all of them sharing the same exact whole-body gradient coil design. Mechanical fixation and boundary conditions of the gradient coil were altered in several ways at one site to study the impact of mechanical coupling with the magnet on the field perturbations. Vibrations, power deposition in the He bath, and field dynamics were characterized at 11.7 T with the third-order shim coils connected and disconnected inside the Faraday cage. RESULTS: For the same whole-body gradient coil design, all measurements differed greatly based on the third-order shim coil configuration (connected or not). Vibrations and gradient transfer function peaks could be affected by a factor of 2 or more, depending on the resonances. Disconnecting the third-order shim coils at 11.7 T also suppressed almost completely power deposition peaks at some frequencies. DISCUSSION: Third-order shim coil configurations can have major impact in gradient-magnet interactions with consequences on potential hardware damage, magnet heating, and image quality going beyond EPI acquisitions.


Assuntos
Imageamento por Ressonância Magnética , Imãs , Imageamento por Ressonância Magnética/métodos
2.
Magn Reson Med ; 91(4): 1723-1734, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38084471

RESUMO

PURPOSE: Testing an RF coil prototype on subjects involves laborious verifications to ensure its safety. In particular, it requires preliminary electromagnetic simulations and their validations on phantoms to accurately predict the specific absorption rate (SAR). For coil design validation with a simpler safety procedure, the restricted SAR (rS) mode is proposed, enabling representative first experiments in vivo. The goal of the developed approach is to accelerate the transition of a custom coil system from prototype to clinical use. METHODS: The restricted specific absorption rate (SAR) (rS) mode imposes a radical limitation on the transmitted RF power based on a worst-case scenario of local RF power absorption. The limitations used are independent of the SAR spatial distribution, making this approach unconditionally safe. The developed rS protocol contains the sequences required for coil evaluation and satisfies the imposed rS conditions. It provides a quantitative characterization of the coil transmission and reception profiles and a qualitative evaluation of the anatomical images. Protocol validation was performed on commercial and pre-industrial prototype coils on a small cohort of healthy volunteers. RESULTS: The proposed rS protocol enables coil evaluation within an acquisition time compatible with common clinical protocol duration. The total time of all evaluation steps does not exceed 17 min. At the same time, the global SAR remains 100 times less than the International Electrotechnical Commission safety limit for played sequences. CONCLUSION: The rS protocol allows characterizing and comparing coil prototypes on volunteers without extensive electromagnetic calculations and phantom validations in an unconditionally safe way.


Assuntos
Imageamento por Ressonância Magnética , Ondas de Rádio , Humanos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas
3.
Magn Reson Med ; 91(3): 1254-1267, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37986237

RESUMO

PURPOSE: We propose a comprehensive workflow to design and build fully customized dense receive arrays for MRI, providing prediction of SNR and g-factor. Combined with additive manufacturing, this method allows an efficient implementation for any arbitrary loop configuration. To demonstrate the methodology, an innovative two-layer, 32-channel receive array is proposed. METHODS: The design workflow is based on numerical simulations using a commercial 3D electromagnetic software associated with circuit model co-simulations to provide the most accurate results in an efficient time. A model to compute the noise covariance matrix from circuit model scattering parameters is proposed. A 32-channel receive array at 7 T is simulated and fabricated with a two-layer design made of non-geometrically decoupled loops. Decoupling between loops is achieved using home-built direct high-impedance preamplifiers. The loops are 3D-printed with a new additive manufacturing technique to speed up integration while preserving the detailed geometry as simulated. The SNR and parallel-imaging performances of the proposed design are compared with a commercial coil, and in vivo images are acquired. RESULTS: The comparison of SNR and g-factors showed a good agreement between simulations and measurements. Experimental values are comparable with the ones measured on the commercial coil. Preliminary in vivo images also ensured the absence of any unexpected artifacts. CONCLUSION: A new design and performance analysis workflow is proposed and tested with a non-conventional 32-channel prototype at 7 T. Additive manufacturing of dense arrays of loops for brain imaging at ultrahigh field is validated for clinical use.


Assuntos
Imageamento por Ressonância Magnética , Neuroimagem , Imagens de Fantasmas , Desenho de Equipamento , Razão Sinal-Ruído , Imageamento por Ressonância Magnética/métodos , Fenômenos Eletromagnéticos , Encéfalo/diagnóstico por imagem
4.
Cell Rep ; 42(11): 113405, 2023 11 28.
Artigo em Inglês | MEDLINE | ID: mdl-37950868

RESUMO

Detection of deviant stimuli is crucial to orient and adapt our behavior. Previous work shows that deviant stimuli elicit phasic activation of the locus coeruleus (LC), which releases noradrenaline and controls central arousal. However, it is unclear whether the detection of behaviorally relevant deviant stimuli selectively triggers LC responses or other neuromodulatory systems (dopamine, serotonin, and acetylcholine). We combine human functional MRI (fMRI) recordings optimized for brainstem imaging with pupillometry to perform a mapping of deviant-related responses in subcortical structures. Participants have to detect deviant items in a "local-global" paradigm that distinguishes between deviance based on the stimulus probability and the sequence structure. fMRI responses to deviant stimuli are distributed in many cortical areas. Both types of deviance elicit responses in the pupil, LC, and other neuromodulatory systems. Our results reveal that the detection of task-relevant deviant items recruits the same multiple subcortical systems across computationally different types of deviance.


Assuntos
Tronco Encefálico , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Locus Cerúleo/diagnóstico por imagem , Nível de Alerta , Pupila/fisiologia
5.
Neuroimage ; 261: 119498, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-35917918

RESUMO

Increased static field inhomogeneities are a burden for human brain MRI at Ultra-High-Field. In particular they cause enhanced Echo-Planar image distortions and signal losses due to magnetic susceptibility gradients at air-tissue interfaces in the subject's head. In the past decade, Multi-Coil Arrays (MCA) have been proposed to shim the field in the brain better than the 2nd or 3rd order Spherical Harmonic (SH) coils usually offered by MRI manufacturers. Here we present a novel MCA, named SCOTCH, optimized for whole brain shimming. Based on a cylindrical structure, it features several layers of small coils whose shape, size and location are found from a principal component analysis of ideal stream functions computed from an internal 100-brain fieldmap database. From an Open-Access external database of 126 brains, our SCOTCH implementation is shown to be equivalent to a partial 7th-order SH system with unlimited power, outperforming all known existing MCA prototypes. This result is further confirmed by a low-cost  30-cm diameter SCOTCH prototype built with 48 coils on 3 layers, and tested on 7 volunteers at 7T with a parallel-transmit RF coil made to be inserted in SCOTCH. Echo-Planar images of the subject brains before and after SCOTCH shimming show large signal recoveries, especially in the prefrontal cortex.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Magnetismo , Ondas de Rádio
6.
MAGMA ; 35(6): 923-941, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35829793

RESUMO

OBJECTIVE: As the MRI main magnetic field rises for improved signal-to-noise ratio, susceptibility-induced B0-inhomogeneity increases proportionally, aggravating related artifacts. Considering only susceptibility disparities between air and biological tissue, we explore the topological conditions for which perfect shimming could be performed in a Region of Interest (ROI) such as the human brain or part thereof. MATERIALS AND METHODS: After theoretical considerations for perfect shimming, spherical harmonic (SH) shimming simulations of very high degree are performed, based on a 100-subject database of 1.7-mm-resolved brain fieldmaps acquired at 3T . In addition to the whole brain, shimmed ROIs include slabs targeting the prefrontal cortex, both or single temporal lobes, or spheres in the frontal brain above the nasal sinus. RESULTS AND DISCUSSION: We show "perfect" SH shimming is possible only if the ROI can be contained in a sphere that does not enclose sources of magnetic field inhomogeneity, which are gathered at the air-tissue interface. We establish a [Formula: see text]Hz inhomogeneity hard shim limit at 7T for whole brain SH shimming, that can only be attained at shimming degree higher than 90. On the other hand, under limited power and SH degree resources, 3D region-specific shimming is shown to greatly improve homogeneity in critical zones such as the prefrontal cortex and around ear canals.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Humanos , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Artefatos , Razão Sinal-Ruído , Campos Magnéticos , Processamento de Imagem Assistida por Computador/métodos
7.
Hum Brain Mapp ; 42(4): 841-870, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33368868

RESUMO

Functional magnetic resonance imaging (fMRI) has opened the possibility to investigate how brain activity is modulated by behavior. Most studies so far are bound to one single task, in which functional responses to a handful of contrasts are analyzed and reported as a group average brain map. Contrariwise, recent data-collection efforts have started to target a systematic spatial representation of multiple mental functions. In this paper, we leverage the Individual Brain Charting (IBC) dataset-a high-resolution task-fMRI dataset acquired in a fixed environment-in order to study the feasibility of individual mapping. First, we verify that the IBC brain maps reproduce those obtained from previous, large-scale datasets using the same tasks. Second, we confirm that the elementary spatial components, inferred across all tasks, are consistently mapped within and, to a lesser extent, across participants. Third, we demonstrate the relevance of the topographic information of the individual contrast maps, showing that contrasts from one task can be predicted by contrasts from other tasks. At last, we showcase the benefit of contrast accumulation for the fine functional characterization of brain regions within a prespecified network. To this end, we analyze the cognitive profile of functional territories pertaining to the language network and prove that these profiles generalize across participants.


Assuntos
Atlas como Assunto , Mapeamento Encefálico/métodos , Córtex Cerebral/diagnóstico por imagem , Córtex Cerebral/fisiologia , Processos Mentais/fisiologia , Rede Nervosa/diagnóstico por imagem , Rede Nervosa/fisiologia , Adulto , Mapeamento Encefálico/normas , Conjuntos de Dados como Assunto , Imagem Ecoplanar , Feminino , Humanos , Masculino , Modelos Teóricos , Fenótipo
8.
Phys Med Biol ; 66(1): 015001, 2021 01 14.
Artigo em Inglês | MEDLINE | ID: mdl-33152723

RESUMO

We exploit the inter-subject similarity of inhomogeneous static magnetic field patterns arising in the human brain under MRI examination to design a small set of shim coils providing performance equivalent to numerous coils based on high-order Spherical Harmonics corrections. A hundred brain B 0-maps were first collected at 3 T. Ideal subject-specific electric current density stream functions are then computed with low power constraints, on a cylindrical surface. This step is repeated over tens of brain maps so that a Principal Component Analysis can be applied to the stream functions; the main components result in the small set of coils. Both 50-subject hold-out and 10-fold cross-validation are employed to evaluate consistency of the proposed system performance over a posteriori subjects. Simulations show that only three cylindrical coils manage to capture the principal magnetic field profiles in the human brain, thus providing a better static field inhomogeneity mitigation than that obtained from 16 unlimited-power high-order Spherical Harmonics coils, with inhomogeneity greatly reduced in the pre-frontal cortex compared to 2nd-order shimmed baseline field acquisitions. The approach provides a very reduced channel count system for mitigating complex B 0-inhomogeneity patterns. Thus, a compact, cost-effective system could be conceived and driven by relatively low-budget electronics. The method should therefore have a strong impact in both ultra-high and portable low-field MRI/MRS. Moreover, this technique can be applied to the design of shim coils addressing anatomies other than the brain.


Assuntos
Mapeamento Encefálico/métodos , Encéfalo/diagnóstico por imagem , Campos Magnéticos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Desenho de Equipamento , Humanos
9.
Sci Data ; 7(1): 353, 2020 10 16.
Artigo em Inglês | MEDLINE | ID: mdl-33067452

RESUMO

We present an extension of the Individual Brain Charting dataset -a high spatial-resolution, multi-task, functional Magnetic Resonance Imaging dataset, intended to support the investigation on the functional principles governing cognition in the human brain. The concomitant data acquisition from the same 12 participants, in the same environment, allows to obtain in the long run finer cognitive topographies, free from inter-subject and inter-site variability. This second release provides more data from psychological domains present in the first release, and also yields data featuring new ones. It includes tasks on e.g. mental time travel, reward, theory-of-mind, pain, numerosity, self-reference effect and speech recognition. In total, 13 tasks with 86 contrasts were added to the dataset and 63 new components were included in the cognitive description of the ensuing contrasts. As the dataset becomes larger, the collection of the corresponding topographies becomes more comprehensive, leading to better brain-atlasing frameworks. This dataset is an open-access facility; raw data and derivatives are publicly available in neuroimaging repositories.


Assuntos
Mapeamento Encefálico , Encéfalo/fisiologia , Cognição , Imageamento por Ressonância Magnética , Humanos
10.
Neuroimage ; 207: 116353, 2020 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-31743789

RESUMO

Non-human primate functional MRI (fMRI) is a growing field in neuroscience. However, there is no standardized method for monkey fMRI data analysis, specifically for data preprocessing. The preprocessing of monkey fMRI data is challenged by several technical and experimental specificities of the monkey research such as artifacts related to body movements or to intracranial leads. Here we propose to address these challenges by developing a new versatile pipeline for macaque fMRI preprocessing. We developed a Python module, Pypreclin, to process raw images using state of the art algorithms embedded in a fully automatic pipeline. To evaluate its robustness, we applied Pypreclin to fMRI data acquired at 3T in both awake and anesthetized macaques, with or without iron oxide contrast agent, using single loop or multichannel phased-array coils, combined or not with intracranial implanted electrodes. We performed both resting-state and auditory evoked fMRI and compared the results of Pypreclin to a previously employed preprocessing pipeline. Pypreclin successfully achieved the registration of the fMRI data to the macaque brain template in all the experimental conditions. Moreover, Pypreclin enables more accurate locations of auditory evoked activations in relation to the gray matter at corrected level in the awake fMRI condition. Finally, using the Primate neuroimaging Data-Exchange open access platform, we could further validate Pypreclin for monkey fMRI images that were acquired at ultra-high fields, from other institutions and using different protocols. Pypreclin is a validated preprocessing tool that adapts to diverse experimental and technical situations of monkey fMRI. Pypreclin code is available on open source data sharing platform.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Movimento/fisiologia , Neuroimagem , Algoritmos , Animais , Encéfalo/fisiologia , Mapeamento Encefálico/métodos , Córtex Cerebral/fisiologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Macaca , Imageamento por Ressonância Magnética/métodos , Masculino , Neuroimagem/métodos
11.
Magn Reson Med ; 82(6): 2016-2031, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31257612

RESUMO

PURPOSE: A calibration-free pulse design method is introduced to alleviate B1+ artifacts in clinical routine with parallel transmission at high field, dealing with significant inter-subject variability, found for instance in the abdomen. THEORY AND METHODS: From a dual-transmit 3T scanner, a database of B1+ and off-resonance abdominal maps from 50 subjects was first divided into 3 clusters based on mutual affinity between their respective tailored kT -points pulses. For each cluster, a kT -points pulse was computed, minimizing normalized root-mean-square flip angle deviations simultaneously for all subjects comprised in it. Using 30 additional subjects' field distributions, a machine learning classifier was trained on this 80-labeled-subject database to recognize the best pulse from the 3 ones available, relying only on patient features accessible from the preliminary localizer sequence present in all protocols. This so-called SmartPulse process was experimentally tested on an additional 53-subject set and compared with other pulse types: vendor's hard calibration-free dual excitation, tailored static radiofrequency shimming, universal and tailored kT -points pulses. RESULTS: SmartPulse outperformed both calibration-free approaches. Tailored static radiofrequency shimming yielded similar flip angle homogeneity for most patients but broke down for some while SmartPulse remained robust. Although flip angle homogeneity was systematically better with tailored kT -points, the difference was barely noticeable on in vivo images. CONCLUSION: The proposed method paves the way toward an efficient trade-off between tailored and universal pulse design approaches for large inter-subject variability. With no need for on-line field mapping or pulse design, it can fit seamlessly into a clinical protocol.


Assuntos
Abdome/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Aprendizado de Máquina , Imageamento por Ressonância Magnética , Ondas de Rádio , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Artefatos , Índice de Massa Corporal , Calibragem , Análise por Conglomerados , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto Jovem
12.
Magn Reson Imaging ; 61: 104-115, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31108151

RESUMO

PURPOSE: To demonstrate that fast-kz spokes can be used in parallel transmission to homogenize flip angle ramp profiles (known as TONE) in slab selections, and thereby improve Time-Of-Flight angiography of the whole human brain at 7T. METHODS: B1+ and B0 maps were measured on seven human brains with a z-segmented coil connected to an 8-channel pTx system. Tailored two-spoke pulses were designed under strict hardware and SAR constraints for uniform slab profile before transforming their subpulse waveforms for linearly-increasing flip-angle ramps. Increasing angulations along the feet-head direction were prescribed in 2-slab and 3-slab TOF acquisitions. Excitation patterns were simulated and compared with RF-shimmed (single spoke) ramp pulses. Excitation performances were assessed in ~10-min TOF acquisitions by visually inspecting Maximal Intensity Projections angiograms. RESULTS: The flip-angle ramp fidelity achieved by double spokes inside slabs of interest was improved by 30-40% compared to RF-shimmed ramps. This allowed better homogenizing signal along arteries, and depicting small vessels in distal areas of the brain, in comparison with RF-shimmed ramp pulses or double-spoke uniform excitation. CONCLUSION: Ramp double spokes used in conjunction with parallel transmission yield better blood saturation compensation and more finely resolved TOF angiograms than mere double spokes or ramp single spokes at 7T.


Assuntos
Artérias/diagnóstico por imagem , Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Angiografia por Ressonância Magnética , Adulto , Algoritmos , Artérias Carótidas/diagnóstico por imagem , Feminino , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Modelos Estatísticos , Tempo , Adulto Jovem
13.
Sci Data ; 5: 180105, 2018 06 12.
Artigo em Inglês | MEDLINE | ID: mdl-29893753

RESUMO

Functional Magnetic Resonance Imaging (fMRI) has furthered brain mapping on perceptual, motor, as well as higher-level cognitive functions. However, to date, no data collection has systematically addressed the functional mapping of cognitive mechanisms at a fine spatial scale. The Individual Brain Charting (IBC) project stands for a high-resolution multi-task fMRI dataset that intends to provide the objective basis toward a comprehensive functional atlas of the human brain. The data refer to a cohort of 12 participants performing many different tasks. The large amount of task-fMRI data on the same subjects yields a precise mapping of the underlying functions, free from both inter-subject and inter-site variability. The present article gives a detailed description of the first release of the IBC dataset. It comprises a dozen of tasks, addressing both low- and high- level cognitive functions. This openly available dataset is thus intended to become a reference for cognitive brain mapping.


Assuntos
Mapeamento Encefálico , Cognição , Humanos , Imageamento por Ressonância Magnética
14.
Magn Reson Med ; 80(1): 53-65, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29193250

RESUMO

PURPOSE: T2 -weighted sequences are particularly sensitive to the radiofrequency (RF) field inhomogeneity problem at ultra-high-field because of the errors accumulated by the imperfections of the train of refocusing pulses. As parallel transmission (pTx) has proved particularly useful to counteract RF heterogeneities, universal pulses were recently demonstrated to save precious time and computational efforts by skipping B1 calibration and online RF pulse tailoring. Here, we report a universal RF pulse design for non-selective refocusing pulses to mitigate the RF inhomogeneity problem at 7T in turbo spin-echo sequences with variable flip angles. METHOD: Average Hamiltonian theory was used to synthetize a single non-selective refocusing pulse with pTx while optimizing its scaling properties in the presence of static field offsets. The design was performed under explicit power and specific absorption rate constraints on a database of 10 subjects using a 8Tx-32Rx commercial coil at 7T. To validate the proposed design, the RF pulses were tested in simulation and applied in vivo on 5 additional test subjects. RESULTS: The root-mean-square rotation angle error (RA-NRMSE) evaluation and experimental data demonstrated great improvement with the proposed universal pulses (RA-NRMSE ∼8%) compared to the standard circularly polarized mode of excitation (RA-NRMSE ∼26%). CONCLUSION: This work further completes the spectrum of 3D universal pulses to mitigate RF field inhomogeneity throughout all 3D MRI sequences without any pTx calibration. The approach returns a single pulse that can be scaled to match the desired flip angle train, thereby increasing the modularity of the proposed plug and play approach. Magn Reson Med 80:53-65, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Encéfalo/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Ondas de Rádio , Adulto , Algoritmos , Aorta/patologia , Mapeamento Encefálico/métodos , Calibragem , Simulação por Computador , Meios de Contraste , Bases de Dados Factuais , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Processamento de Sinais Assistido por Computador , Adulto Jovem
15.
J Magn Reson Imaging ; 47(6): 1562-1571, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29159855

RESUMO

BACKGROUND: The excitation inhomogeneity artifact occurring at 3T in the abdomen can lead to dramatic loss of signal and contrast, thereby hampering diagnosis. PURPOSE: To assess excitation homogeneity and image quality achieved by nonselective prototypical kT -points pulses, compared to tailored static RF shimming, in clinical routine on a commercial dual-transmit scanner. STUDY TYPE: Retrospective study with Institutional Review Board approval; informed consent was waived. POPULATION: Fifty consecutive patients referred for liver MRI at a single hospital. FIELD STRENGTH/SEQUENCE: 3D breath-hold dynamic contrast-enhanced (DCE) MRI at 3T. ASSESSMENT: Flip angle homogeneity was estimated via numerical simulation based on measured static and RF field maps. In all, 20 of the 50 patients underwent DCE-MRI while a pulse designer was present. The effect of RF shimming and kT -point pulses could be compared by repeating the acquisition with each transmit scheme before injection and in the late phase. Signal homogeneity, T1 contrast, enhancement quality, structure details, and global image quality were assessed on a 4-level scale (0 to 3) by two radiologists. STATISTICAL TESTS: Means were compared using Wilcoxon signed-rank tests. RESULTS: Normalized root mean square flip angle error was significantly reduced with kT -points compared to static RF shimming (8.5% ± 1.5% [mean ± standard deviation, SD] vs. 20.4% ± 9.8%; P < 0.0001). The worst case (heavy ascites) led to 13.0% (kT -points) vs. 54.9% (RF shimming). Global image quality was significantly higher for kT -points (2.3 ± 0.5 vs. 1.9 ± 0.6; P = 0.008). One subject's examination was judged unusable with RF shimming by one reader, none with kT -points. 85% of kT -points acquisitions were graded at least 2/3, and only 55% for static RF shimming. DATA CONCLUSION: KT -points reduce excitation inhomogeneity quantitatively and qualitatively, especially in patients with ascites and prone to B1 shading. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:1562-1571.


Assuntos
Artefatos , Processamento de Imagem Assistida por Computador/métodos , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Radiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Ascite/diagnóstico por imagem , Simulação por Computador , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Modelos Teóricos , Pâncreas/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos , Processamento de Sinais Assistido por Computador , Adulto Jovem
16.
PLoS One ; 12(8): e0183562, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28827835

RESUMO

Parallel transmission (pTx) technology, despite its great potential to mitigate the transmit field inhomogeneity problem in magnetic resonance imaging at ultra-high field (UHF), suffers from a cumbersome calibration procedure, thereby making the approach problematic for routine use. The purpose of this work is to demonstrate on two different 7T systems respectively equipped with 8-transmit-channel RF coils from two different suppliers (Rapid-Biomed and Nova Medical), the benefit of so-called universal pulses (UP), optimized to produce uniform excitations in the brain in a population of adults and making unnecessary the calibration procedures mentioned above. Non-selective and slice-selective UPs were designed to return homogeneous excitation profiles throughout the brain simultaneously on a group of ten subjects, which then were subsequently tested on ten additional volunteers in magnetization prepared rapid gradient echo (MPRAGE) and multi-slice gradient echo (2D GRE) protocols. The results were additionally compared experimentally with the standard non-pTx circularly-polarized (CP) mode, and in simulation with subject-specific tailored excitations. For both pulse types and both coils, the UP mode returned a better signal and contrast homogeneity than the CP mode. Retrospective analysis of the flip angle (FA) suggests that the FA deviation from the nominal FA on average over a healthy adult population does not exceed 11% with the calibration-free parallel-transmit pulses whereas it goes beyond 25% with the CP mode. As a result the universal pulses designed in this work confirm their relevance in 3D and 2D protocols with commercially available equipment. Plug-and-play pTx implementations henceforth become accessible to exploit with more flexibility the potential of UHF for brain imaging.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Ondas de Rádio , Encéfalo/diagnóstico por imagem , Humanos
17.
Magn Reson Med ; 78(6): 2194-2202, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28112827

RESUMO

PURPOSE: Small gradient delays with respect to radiofrequency (RF) events can have disastrous effects on the performance of bipolar spokes RF pulses used in parallel transmission (pTx). In this work, we propose a new method to characterize and correct this delay with sub-µs precision. METHODS: By determining experimentally the phase Δφ producing a 0 ° flip angle excitation in a α0°-α180°+Δφ bipolar two-spoke pulse configuration at multiple slice locations, we demonstrate the possibility of deducing the underlying gradient delay with precision. The technique also suggests prospectively compensating for the same delay by altering the phase of the second pulse. The approach was tested with a multislice gradient echo sequence on a phantom and on one healthy volunteer at 7 Tesla. RESULTS: Application of the method returned an accuracy of approximately 50 ns on the gradient delay measurement, a performance shown in fact to be desirable for high-performance pTx 2D applications. Phase corrections of up to 180 ° on the second spoke RF pulse in the bipolar configuration allowed us to obtain similar performance as for unipolar designs, yet with significantly shorter excitations. CONCLUSIONS: A simple and accurate gradient-delay calibration method was proposed that offers the possibility of using bipolar multispoke pulses in multislice protocols. Magn Reson Med 78:2194-2202, 2017. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Imageamento por Ressonância Magnética , Ondas de Rádio , Adulto , Algoritmos , Encéfalo/diagnóstico por imagem , Calibragem , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Reprodutibilidade dos Testes , Água/química
18.
Magn Reson Med ; 77(2): 635-643, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-26888654

RESUMO

PURPOSE: A calibration-free parallel transmission method is investigated to mitigate the radiofrequency (RF) field inhomogeneity problem in brain imaging at 7 Tesla (T). THEORY AND METHODS: Six volunteers were scanned to build a representative database of RF and static field maps at 7T. Small-tip-angle and inversion pulses were designed with joint kT -points trajectory optimization to work robustly on all six subjects. The returned "universal" pulses were then inserted in an MPRAGE sequence implemented on six additional volunteers without further field measurements and pulse optimizations. Similar acquisitions were performed in the circularly polarized mode and with subject-based optimizations for comparison. Performance of the different approaches was evaluated by means of image analysis and computation of the flip angle normalized root mean square errors (NRMSE). RESULTS: For both the excitation and inversion, the universal pulses (NRMSE∼11%) outperformed the circularly polarized (NRMSE∼28%) and RF shim modes (NRMSE∼20%) across all volunteers and returned slightly worse results than for subject-based optimized pulses (NRMSE∼7%). CONCLUSION: RF pulses can be designed to robustly mitigate the RF field inhomogeneity problem over a population class. This appears as a first step toward another plug and play parallel transmission solution where the pulse design can be done offline and without measuring subject-specific field maps. Magn Reson Med 77:635-643, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Algoritmos , Encéfalo/anatomia & histologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Processamento de Sinais Assistido por Computador , Adulto , Calibragem , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
J Magn Reson ; 275: 11-18, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27951426

RESUMO

Parallel transmission is a very promising method to tackle B1+ field inhomogeneities at ultrahigh field in magnetic resonant imaging (MRI). This technique is however limited by the mutual coupling between the radiating elements. Here we propose to solve this problem by designing a passive magneto-electric resonator that we here refer to as stacked magnetic resonator (SMR). By combining numerical and experimental methodologies, we prove that this novelty passive solution allows an efficient decoupling of elements of a phased-array coil. We demonstrate the ability of this technique to significantly reduce by more than 10dB the coupling preserving the quality of images compared to ideally isolated linear resonators on a spherical salty agar gel phantom in a 7T MRI scanner.

20.
Magn Reson Med ; 78(3): 1009-1019, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-27774653

RESUMO

PURPOSE: A multispoke specific absorption rate (SAR) -aware pulse design approach for homogeneous multiple-slice small and large flip angle (FA) excitations with parallel transmission is proposed. The approach aims at optimizing in a slice-specific manner the spokes locations and radiofrequency pulses. METHODS: The problem is posed as a set of slice-specific magnitude-least-squares problems, linked together by hardware and SAR constraints, and solved jointly using an active-set algorithm. Average Hamiltonian theory is exploited in the large FA case to greatly reduce the computational burden. The approach is validated numerically by means of simulations and experimentally on two volunteers at 7 Tesla through application of a high-resolution T2*-weighted brain imaging protocol. RESULTS: The optimization of up to 1300 variables under 745 explicit constraints could be performed in less than 1 and 4 min for the small and large FA cases, respectively. The joint design proves valuable for SAR demanding protocols. Compared with the conventional circularly polarized mode, the designed pulses increased the signal by more than 40% in 70% of the voxels. CONCLUSION: The B1+ inhomogeneity problem was mitigated efficiently in a multislice near whole-brain coverage protocol in the small and large FA regimes using a rapid slice-specific pulse design algorithm where the pulses were optimized jointly. Magn Reson Med 78:1009-1019, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Algoritmos , Simulação por Computador , Humanos