Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Total Environ ; 890: 164304, 2023 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-37230348

RESUMO

Polar regions are the most exposed to secondary particles and radiation produced by primary cosmic rays in the atmosphere, because naturally they are with marginal geomagnetic shielding. In addition, the secondary particle flux contributing to the complex radiation field is enhanced at high-mountain altitudes compared to sea level because of the reduced atmospheric attenuation. At present, there are very few systematic experimental measurements of environmental dose at high southern latitudes, specifically at high-altitude region. Here, we report a campaign of measurements with different devices, that is passive and Liulin-type dosimeters, of the radiation background at high-mountain Antarctic station Vostok (3488 m above sea level, 78° 27' S; 106° 50' E). We compare the measurements with a Monte Carlo-based model for the propagation of the cosmic rays through the atmosphere and assessment of the radiation field in the atmosphere. We employed the model to estimate the radiation dose at Vostok station during the ground-level enhancement at 28 October 2021. As in previous studies by other teams, we show that the annual dose equivalent at high-altitude Antarctic facilities can significantly exceed the limit of 1 mSv established for the general population by the ICRP.


Assuntos
Radiação Cósmica , Monitoramento de Radiação , Humanos , Altitude , Regiões Antárticas , Atmosfera , Doses de Radiação , Aeronaves
2.
Phys Med Biol ; 66(3): 035012, 2021 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-33202399

RESUMO

The lowest possible energy of proton scanning beam in cyclotron proton therapy facilities is typically between 60 and 100 MeV. Treatment of superficial lesions requires a pre-absorber to deliver doses to shallower volumes. In most of the cases a range shifter (RS) is used, but as an alternative solution, a patient-specific 3D printed proton beam compensator (BC) can be applied. A BC enables further reduction of the air gap and consequently reduction of beam scattering. Such pre-absorbers are additional sources of secondary radiation. The aim of this work was the comparison of RS and BC with respect to out-of-field doses for a simulated treatment of superficial paediatric brain tumours. EURADOS WG9 performed comparative measurements of scattered radiation in the Proteus C-235 IBA facility (Cyclotron Centre Bronowice at the Institute of Nuclear Physics, CCB IFJ PAN, Kraków, Poland) using two anthropomorphic phantoms-5 and 10 yr old-for a superficial target in the brain. Both active detectors located inside the therapy room, and passive detectors placed inside the phantoms were used. Measurements were supplemented by Monte Carlo simulation of the radiation transport. For the applied 3D printed pre-absorbers, out-of-field doses from both secondary photons and neutrons were lower than for RS. Measurements with active environmental dosimeters at five positions inside the therapy room indicated that the RS/BC ratio of the out-of-field dose was also higher than one, with a maximum of 1.7. Photon dose inside phantoms leads to higher out-of-field doses for RS than BC to almost all organs with the highest RS/BC ratio 12.5 and 13.2 for breasts for 5 and 10 yr old phantoms, respectively. For organs closest to the isocentre such as the thyroid, neutron doses were lower for BC than RS due to neutrons moderation in the target volume, but for more distant organs like bladder-conversely-lower doses for RS than BC were observed. The use of 3D printed BC as the pre-absorber placed in the near vicinity of patient in the treatment of superficial tumours does not result in the increase of secondary radiation compared to the treatment with RS, placed far from the patient.


Assuntos
Impressão Tridimensional , Terapia com Prótons/instrumentação , Doses de Radiação , Neoplasias Encefálicas/radioterapia , Criança , Simulação por Computador , Humanos , Método de Monte Carlo , Nêutrons , Imagens de Fantasmas , Dosagem Radioterapêutica
3.
Radiat Prot Dosimetry ; 186(2-3): 215-218, 2019 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-31808537

RESUMO

Thunderstorm ground enhancement (TGE) is a phenomenon that enhances radiation background on the ground related to thunderstorm activity and charge structure of the thundercloud. On the other hand, the rise of gamma background is connected with precipitation by the washout of radon progeny from the atmosphere. In our analysis, we examined known enhancements of gamma background, previously attributed solely to radon progeny, using data from the Czech Radiation Monitoring Network (RMN) to investigate the enhancements with respect to thunderstorms and TGE phenomena. We also used radar precipitation data and data from the lightning location network to analyze their influences on the radiation background enhancement during three thunderstorm events that occurred in summer 2016 over the Czech Republic (Central Europe). We state that the RMN might have detected TGE over the Czech Republic.


Assuntos
Monitoramento de Radiação/instrumentação , Produtos de Decaimento de Radônio/análise , Chuva , Tempo (Meteorologia) , Atmosfera , República Tcheca , Raios gama , Geografia , Monitoramento de Radiação/métodos , Radônio/análise , Estações do Ano
4.
Phys Med Biol ; 63(21): 215020, 2018 10 29.
Artigo em Inglês | MEDLINE | ID: mdl-30372419

RESUMO

The aim of this study was to investigate the absorbed dose and the linear energy transfer (LET) of a scanning proton pencil beam at the Proton Therapy Center Czech, applied to phantoms containing metal implants. We investigated two different phantoms composed of commonly used metals with a known chemical composition. Two rectangular phantoms consisted of water-equivalent environment material with a 65 mm thickness surrounding the 2, 5, 10 and 15 mm inserts of grade-2 and grade-5 Titanium. Track-etched detectors (TEDs) were placed behind the phantoms to gather the data. The measured LET spectra behind the implants were compared with Monte Carlo simulations using the Geant4 toolkit, version 10.03.p01. The simulations were used to provide additional information regarding the contribution of each type of particles to the LET spectra (protons, alpha particles, deuteron, neutrons, photons, and electrons) and to estimate the LET spectra above the TED's detection threshold. We used two different beam energies to study the most pertinent irradiation scenarios, one in the Bragg curve plateau and one at the maximum. The measurement of the LET spectra behind phantoms irradiated with a proton beam in the plateau region of the Bragg curve led to the detection of numerous particles with a very high LET. Lateral dose enhancement at the border between implants and the plastic material was detected when the phantoms were exposed to a proton beam and the data were recorded in the Bragg peak maximum. In this area, the dose increased 13 times for grade-2 Ti and 12 times for grade-5 Ti. The performed experimental study highlights the effect of dental implants on the LET spectra and absorbed dose when a proton pencil beam is crossing high-density titanium.


Assuntos
Implantes Dentários , Terapia com Prótons , Titânio , Artefatos , Humanos , Transferência Linear de Energia , Método de Monte Carlo , Imagens de Fantasmas , Radiometria
5.
Phys Med Biol ; 63(8): 085017, 2018 04 19.
Artigo em Inglês | MEDLINE | ID: mdl-29509148

RESUMO

Systematic 3D mapping of out-of-field doses induced by a therapeutic proton pencil scanning beam in a 300 × 300 × 600 mm3 water phantom was performed using a set of thermoluminescence detectors (TLDs): MTS-7 (7LiF:Mg,Ti), MTS-6 (6LiF:Mg,Ti), MTS-N (natLiF:Mg,Ti) and TLD-700 (7LiF:Mg,Ti), radiophotoluminescent (RPL) detectors GD-352M and GD-302M, and polyallyldiglycol carbonate (PADC)-based (C12H18O7) track-etched detectors. Neutron and gamma-ray doses, as well as linear energy transfer distributions, were experimentally determined at 200 points within the phantom. In parallel, the Geant4 Monte Carlo code was applied to calculate neutron and gamma radiation spectra at the position of each detector. For the cubic proton target volume of 100 × 100 × 100 mm3 (spread out Bragg peak with a modulation of 100 mm) the scattered photon doses along the main axis of the phantom perpendicular to the primary beam were approximately 0.5 mGy Gy-1 at a distance of 100 mm and 0.02 mGy Gy-1 at 300 mm from the center of the target. For the neutrons, the corresponding values of dose equivalent were found to be ~0.7 and ~0.06 mSv Gy-1, respectively. The measured neutron doses were comparable with the out-of-field neutron doses from a similar experiment with 20 MV x-rays, whereas photon doses for the scanning proton beam were up to three orders of magnitude lower.


Assuntos
Imageamento Tridimensional/métodos , Imagens de Fantasmas , Terapia com Prótons/métodos , Radiometria/métodos , Dosimetria Termoluminescente/métodos , Raios gama , Humanos , Método de Monte Carlo , Nêutrons , Fótons , Prótons , Radioatividade , Cintilografia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Dosimetria Termoluminescente/instrumentação , Água
6.
Radiat Prot Dosimetry ; 181(4): 412-417, 2018 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-29566221

RESUMO

The evaluation of different components of secondary radiation (charged fragments and neutrons) onboard ISS is described. Solid-state nuclear track detectors CR-39™ were applied for the measurements of short-range nuclear fragments, while the measurements of neutrons were carried out by means of thermo-luminescent dosimeters with various concentrations of 6Li and 7Li. The flux of charged secondaries and the gamma-equivalent neutron dose are presented in function of the low-LET dose in various modules of the Russian segment of ISS.


Assuntos
Astronautas , Radiação Cósmica , Exposição Ocupacional/análise , Monitoramento de Radiação/instrumentação , Astronave , Humanos , Nêutrons , Doses de Radiação , Radiometria , Dosimetria Termoluminescente
7.
Radiat Prot Dosimetry ; 180(1-4): 138-141, 2018 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-29036726

RESUMO

Cosmic radiation consists of primary high-energy galactic and solar particles. When passing through spacecraft walls and astronauts' bodies, the spectrum becomes even more complex due to generating of secondary particles through fragmentation and nuclear interactions. Total radiation exposure is contributed by both these components. With an advantage, space research uses track etched detectors from the group of passive detectors visualizing the tracks of particles, in this case by etching. The detectors can discriminate between various components of cosmic radiation. A method is introduced for the separation of the different types of particles according to their range using track etched detectors. The method is demonstrated using detectors placed in Russian segment of the International Space Station in 2009. It is shown that the primary high-energy heavy ions with long range contribute up to 56% of the absorbed dose and up to 50% to the dose equivalent.


Assuntos
Radiação Cósmica , Partículas Elementares , Modelos Teóricos , Exposição Ocupacional/análise , Monitoramento de Radiação/instrumentação , Monitoramento de Radiação/métodos , Astronave , Astronautas , Humanos , Doses de Radiação
8.
Radiat Prot Dosimetry ; 180(1-4): 256-260, 2018 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-29165619

RESUMO

Proton beam therapy has advantages in comparison to conventional photon radiotherapy due to the physical properties of proton beams (e.g. sharp distal fall off, adjustable range and modulation). In proton therapy, there is the possibility of sparing healthy tissue close to the target volume. This is especially important when tumours are located next to critical organs and while treating cancer in paediatric patients. On the other hand, the interactions of protons with matter result in the production of secondary radiation, mostly neutrons and gamma radiation, which deposit their energy at a distance from the target. The aim of this study was to compare the response of different passive dosimetry systems in mixed radiation field induced by proton pencil beam inside anthropomorphic phantoms representing 5 and 10 years old children. Doses were measured in different organs with thermoluminescent (MTS-7, MTS-6 and MCP-N), radiophotoluminescent (GD-352 M and GD-302M), bubble and poly-allyl-diglycol carbonate (PADC) track detectors. Results show that RPL detectors are the less sensitive for neutrons than LiF TLDs and can be applied for in-phantom dosimetry of gamma component. Neutron doses determined using track detectors, bubble detectors and pairs of MTS-7/MTS-6 are consistent within the uncertainty range. This is the first study dealing with measurements on child anthropomorphic phantoms irradiated by a pencil scanning beam technique.


Assuntos
Imagens de Fantasmas , Terapia com Prótons/instrumentação , Prótons , Radiometria/instrumentação , Dosimetria Termoluminescente/instrumentação , Algoritmos , Antropometria , Criança , Pré-Escolar , Desenho de Equipamento , Raios gama/uso terapêutico , Humanos , Método de Monte Carlo , Nêutrons , Doses de Radiação , Radiação Ionizante , Cintilografia , Dosagem Radioterapêutica
9.
Radiat Prot Dosimetry ; 170(1-4): 318-21, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26979806

RESUMO

In laser-driven acceleration, ultra-short and intense laser pulses are focussed on targets to generate beams of ionising radiation. One of the most important issues to be addressed is personal monitoring. While traditional dosemeters were designed primarily for measurements in continuous fields, dosemeters for laser laboratories must be capable of working in pulsed fields of pulse length below 1 ps, in a single-shot regime up to the repetition rate of 1 kHz. Responses of conventional dosemeters (films, polyallyldiglycol carbonate, electronic personal dosemeter) to proton bunches of up to 30 MeV energy produced by South Korean PW laser system at the Advanced Photonics Research Institute, Gwangju Institute of Science and Technology were studied, both by means of Monte Carlo simulations and experimentally.


Assuntos
Dosimetria Fotográfica/instrumentação , Prótons , Doses de Radiação , Dosímetros de Radiação , Monitoramento de Radiação/instrumentação , Calibragem , Carbonatos/química , Simulação por Computador , Dosimetria Fotográfica/métodos , Glicóis/química , Humanos , Lasers , Método de Monte Carlo , Plásticos , Monitoramento de Radiação/métodos , Radiação Ionizante , Reprodutibilidade dos Testes , República da Coreia
10.
Radiat Prot Dosimetry ; 164(4): 489-92, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25979744

RESUMO

The annual effective doses of aircrew members often exceed the limit of 1 mSv for the public due to the increased level of cosmic radiation at the flight altitudes, and thus, it is recommended to monitor them. Aircrew dosimetry is usually performed using special computer programs mostly based on results of Monte Carlo simulations. Contemporary, detectors are used mostly for validation of these computer codes, verification of effective dose calculations and for research purposes. One of such detectors is active silicon semiconductor deposited energy spectrometer Liulin. Output quantities of measurement with the Liulin detector are the absorbed dose in silicon D and the ambient dose equivalent H*(10); to determine it, two calibrations are necessary. The purpose of this work was to develop a calibration methodology that can be used to convert signal from the detector to D independently on calibration performed at Heavy Ion Medical Accelerator facility in Chiba, Japan.


Assuntos
Aeronaves/instrumentação , Radiação Cósmica , Exposição Ocupacional/análise , Monitoramento de Radiação/instrumentação , Absorção de Radiação , Altitude , Calibragem , Desenho de Equipamento , Íons Pesados , Humanos , Método de Monte Carlo , Nêutrons , Exposição Ocupacional/normas , Exposição à Radiação , Radioisótopos , Semicondutores , Silício , Atividade Solar
11.
Radiat Prot Dosimetry ; 164(4): 477-83, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25979747

RESUMO

On the Earth, protection from cosmic radiation is provided by the magnetosphere and the atmosphere, but the radiation exposure increases with increasing altitude. Aircrew and especially space crew members are therefore exposed to an increased level of ionising radiation. Dosimetry onboard aircraft and spacecraft is however complicated by the presence of neutrons and high linear energy transfer particles. Film and thermoluminescent dosimeters, routinely used for ground-based personnel, do not reliably cover the range of particle types and energies found in cosmic radiation. Further, the radiation field onboard aircraft and spacecraft is not constant; its intensity and composition change mainly with altitude, geomagnetic position and solar activity (marginally also with the aircraft/spacecraft type, number of people aboard, amount of fuel etc.). The European Union Council directive 96/29/Euroatom of 1996 specifies that aircrews that could receive dose of >1 mSv y(-1) must be evaluated. The dose evaluation is routinely performed by computer programs, e.g. CARI-6, EPCARD, SIEVERT, PCAire, JISCARD and AVIDOS. Such calculations should however be carefully verified and validated. Measurements of the radiation field in aircraft are thus of a great importance. A promising option is the long-term deployment of active detectors, e.g. silicon spectrometer Liulin, TEPC Hawk and pixel detector Timepix. Outside the Earth's protective atmosphere and magnetosphere, the environment is much harsher than at aviation altitudes. In addition to the exposure to high energetic ionising cosmic radiation, there are microgravity, lack of atmosphere, psychological and psychosocial components etc. The milieu is therefore very unfriendly for any living organism. In case of solar flares, exposures of spacecraft crews may even be lethal. In this paper, long-term measurements of the radiation environment onboard Czech aircraft performed with the Liulin since 2001, as well as measurements and simulations of dose rates on and outside the International Space Station were presented. The measured and simulated results are discussed in the context of health impact.


Assuntos
Medicina Aeroespacial , Radiação Cósmica , Exposição Ocupacional , Doses de Radiação , Exposição à Radiação , Voo Espacial , Aeronaves , Atmosfera , Humanos , Transferência Linear de Energia , Nêutrons , Imagens de Fantasmas , Radiometria/instrumentação , Radiometria/métodos , Software , Atividade Solar , Astronave
12.
Radiat Prot Dosimetry ; 166(1-4): 247-52, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25862534

RESUMO

Track-etched detectors (TED) have been used as linear energy transfer (LET) spectrometers in heavy ion beams for many years. LET spectra and depth-dose distribution of a carbon ion beam were measured behind polymethylmethacrylate degraders at Heavy Ion Medical Accelerator in Chiba, Japan. The measurements were performed along monoenergetic beam with energy 290 MeV u(-1) in different positions: (1) at beam extraction area, (2) at beginning, (3) maximum and (4) behind the Bragg peak region (0, 117, 147 and 151 mm of water-equivalent depth, respectively). The LET spectra inside and outside of the primary ion beam have been evaluated. TED record only heavy charged particles with LET above 8-10 keV µm(-1), while electrons and ions with lower LET are not detected. The Geant4 simulation toolkit version 4.9.6.P01 has been used to estimate the contribution of non-detected particles to absorbed dose. Presented results demonstrate the applicability of TED for microdosimetry measurements in therapeutic carbon ion beams.


Assuntos
Carbono , Íons Pesados , Transferência Linear de Energia/efeitos da radiação , Microtecnologia/métodos , Aceleradores de Partículas/instrumentação , Polimetil Metacrilato/química , Radiometria/instrumentação , Calibragem , Simulação por Computador , Elétrons , Desenho de Equipamento , Doses de Radiação
13.
Radiat Prot Dosimetry ; 161(1-4): 410-6, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24759915

RESUMO

Dose delivered outside the proton field during radiotherapy can potentially lead to secondary cancer development. Measurements with a 170-MeV proton beam were performed with passive detectors (track etched detectors and thermoluminescence dosemeters) in three different depths along the Bragg curve. The measurement showed an uneven decrease of the dose outside of the beam field with local enhancements. The major contribution to the delivered dose is due to high-energy protons with linear energy transfer (LET) up to 10 keV µm(-1). However, both measurement and preliminary Monte Carlo calculation also confirmed the presence of particles with higher LET.


Assuntos
Prótons , Radiometria/instrumentação , Radiometria/métodos , Dosagem Radioterapêutica , Dosimetria Termoluminescente/instrumentação , Dosimetria Termoluminescente/métodos , Desenho de Equipamento , Humanos , Transferência Linear de Energia , Método de Monte Carlo , Nêutrons , Imagens de Fantasmas , Polimetil Metacrilato/química , Terapia com Prótons/efeitos adversos , Radioterapia/efeitos adversos , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Alta Energia , Reprodutibilidade dos Testes , Federação Russa
14.
Radiat Prot Dosimetry ; 162(3): 215-9, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24344348

RESUMO

The annual effective doses of aircrew members often exceed the limit of 1 mSv for the public due to the increased level of cosmic radiation at the flight altitudes, and thus, it is recommended to monitor them [International Commission on Radiation Protection. 1990 Recommendations of the International Commission on Radiological Protection. ICRP Publication 60. Ann. ICRP 21: (1-3), (1991)]. According to the Monte Carlo simulations [Battistoni, G., Ferrari, A., Pelliccioni, M. and Villari, R. Evaluation of the doses to aircrew members taking into consideration the aircraft structures. Adv. Space Res. 36: , 1645-1652 (2005) and Ferrari, A., Pelliccioni, M. and Villari, R. Evaluation of the influence of aircraft shielding on the aircrew exposure through an aircraft mathematical model. Radiat. Prot. Dosim. 108: (2), 91-105 (2004)], the ambient dose equivalent rate H*(10) depends on the location in the aircraft. The aim of this article is to experimentally evaluate H*(10) on-board selected types of aircraft. The authors found that H*(10) values are higher in the front and the back of the cabin and lesser in the middle of the cabin. Moreover, total dosimetry characteristics obtained in this way are in a reasonable agreement with other data, in particular with the above-mentioned simulations.


Assuntos
Aeronaves , Radiação Cósmica , Exposição Ocupacional/análise , Monitoramento de Radiação/instrumentação , Proteção Radiológica/normas , Aviação , Relação Dose-Resposta à Radiação , Humanos , Modelos Teóricos , Doses de Radiação , Proteção Radiológica/instrumentação , Software
15.
Radiat Prot Dosimetry ; 143(2-4): 519-22, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21245064

RESUMO

Active mobile dosimetry unit (Liulin), passive plastic nuclear track detectors (PNTD) and thermoluminescent detectors (TLD) were exposed in a C290 MeV/n beam at HIMAC-BIO (NIRS, Japan). Two different types of beam configuration were used--monoenergetic beam (MONO) and spread-out Bragg peak (SOBP); the detectors were placed at several depths from the entrance up to the depths behind the Bragg peak. Relative response of TLDs in beams has been studied as a function of the depth, and it was re-proved that it can depend on the linear energy transfer (LET). Liulin measures energy deposition in Si; the spectra of energy deposited in Si can be transformed to the spectra of lineal energy or LET. PNTDs are able to determine the LET of registered particles directly. The limitation of both methods is in the range in which they can determine the LET-Liulin is able to measure perpendicularly incident charged particles up to ∼35 keV/µm (in water), PNTD can measure from ∼7 to 400 keV/µm, independently of the registration angle. The results from both methods are compared and combined for both beams' configuration, and a good agreement is observed.


Assuntos
Radioterapia com Íons Pesados , Transferência Linear de Energia , Aceleradores de Partículas/instrumentação , Radiometria/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Japão
16.
Radiat Prot Dosimetry ; 143(2-4): 440-4, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21156782

RESUMO

Five various materials employed as track-etched detectors (TEDs) were exposed in beams of carbon ions with energy 290 MeV. u(-1) in the HIMAC-BIO facility in Japan. The exposures were performed behind various types of polymethyl methacrylate shielding. The beam had two possible set-ups--monoenergetic set-up and modulated spread-out Bragg peak set-up. All used TEDs are polyallyl diglycol carbonates (PADCs): Page from Mouldings (Pershore) Ltd, Tastrak from Track Analysis Systems Ltd, both from the UK; USF4 from American Technical Plastics from the USA and two products of Japan Fukuvi Chemical Industry Co., Ltd--TD1 and Baryotrak. Spectra of linear energy transfer and depth-dose distributions were obtained. Besides, differences among PADCs are discussed.


Assuntos
Carbono , Íons Pesados , Transferência Linear de Energia , Análise Espectral/instrumentação , Análise Espectral/métodos , Doses de Radiação
17.
Radiat Prot Dosimetry ; 144(1-4): 605-10, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20959332

RESUMO

To estimate the radiation risk of astronauts during space missions, it is necessary to measure dose characteristics in various compartments of the spacecraft; this knowledge can be further used for estimating the health hazard in planned missions. This contribution presents results obtained during several missions on board the International Space Station (ISS) during 2005-09. A combination of thermoluminescent and plastic nuclear track detectors was used to measure the absorbed dose and dose equivalent. These passive detectors have several advantages, especially small dimensions, which enabled their placement at various locations in different compartments inside the ISS or inside the phantom. Variation of dosimetric quantities with the phase of the solar cycle and the position inside the ISS is discussed.


Assuntos
Monitoramento de Radiação/métodos , Radiometria/métodos , Voo Espacial/métodos , Astronautas , Radiação Cósmica , Humanos , Nêutrons , Imagens de Fantasmas , Prótons , Doses de Radiação , Monitoramento de Radiação/instrumentação , Proteção Radiológica/métodos , Risco , Atividade Solar , Astronave
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...