Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Insights Imaging ; 15(1): 201, 2024 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-39120665

RESUMO

Dose management systems (DMS) are an essential tool for quality assurance and optimising patient radiation exposure. For radiologists and medical physicists, they are important for managing many radiation protection tasks. In addition, they help fulfil the requirements of Directive 2013/59/EURATOM regarding the electronic transmission of dosimetric data and the detection of unintended patient exposures. The EuroSafe Imaging Clinical Dosimetry and Dose Management Working Group launched a questionnaire on the use of DMS in European member states and analysed the results in terms of modalities, frequency of radiological procedures, involvement of medical physics experts (MPEs), legal requirements, and local issues (support by information technology (IT), modality interfaces, protocol mapping, clinical workflow, and associated costs). CRITICAL RELEVANCE STATEMENT: Despite the great advantages of dose management systems for optimising radiation protection, distribution remains insufficient. This questionnaire shows that reasons include: a lack of DICOM interfaces, insufficient harmonisation of procedure names, lack of medical physicist and IT support, and costs. KEY POINTS: Quantitative radiation dose information is essential for justification and optimisation in medical imaging. Guidelines are required to ensure radiation dose management systems quality and for acceptance testing. Verifying dose data management is crucial before dose management systems clinical implementation. Medical physics experts are professionals who have important responsibilities for the proper management of dose monitoring.

2.
J Pers Med ; 13(4)2023 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-37109029

RESUMO

The prediction of radiation exposure is an important tool for the choice of therapy modality and becomes, as a component of patient-informed consent, increasingly important for both surgeon and patient. The final goal is the implementation of a trained and tested machine learning model in a real-time computer system allowing the surgeon and patient to better assess patient's personal radiation risk. In summary, 995 patients with ureterorenoscopy over a period from May 2016 to December 2019 were included. According to the suggestions based on actual literature evidence, dose area product (DAP) was categorized into 'low doses' ≤ 2.8 Gy·cm2 and 'high doses' > 2.8 Gy·cm2 for ureterorenoscopy (URS). To forecast the level of radiation exposure during treatment, six different machine learning models were trained, and 10-fold crossvalidated and their model performances evaluated in training and independent test samples. The negative predictive value for low DAP during ureterorenoscopy was 94% (95% CI: 92-96%). Factors influencing the radiation exposure were: age (p = 0.0002), gender (p = 0.011), weight (p < 0.0001), stone size (p < 0.000001), surgeon experience (p = 0.039), number of stones (p = 0.0007), stone density (p = 0.023), use of flexible endoscope (p < 0.0001) and preoperative stone position (p < 0.00001). The machine learning algorithm identified a subgroup of patients of 81% of the total sample, for which highly accurate predictions (94%) were possible allowing the surgeon to assess patient's personal radiation risk. Patients without prediction (19%), the medical expert can make decisions as usual. Next step will be the implementation of the trained model in real-time computer systems for clinical decision processes in daily practice.

3.
Invest Radiol ; 58(2): 126-130, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-35926075

RESUMO

OBJECTIVE: The aim of this study was to evaluate whether a 3-dimensional (3D) camera can outperform highly trained technicians in precision of patient positioning and whether this transforms into a reduction in patient exposure. MATERIALS AND METHODS: In a single-center study, 3118 patients underwent computer tomography (CT) scans of the chest and/or abdomen on a latest generation single-source CT scanner supported with an automated patient positioning system by 3D camera. One thousand five hundred fifty-seven patients were positioned laser-guided by a highly trained radiographer (camera off) and 1561 patients with 3D camera (camera on) guidance. Radiation parameters such as effective dose, organ doses, CT dose index, and dose length product were analyzed and compared. Isocenter accuracy and table height were evaluated between the 2 groups. RESULTS: Isocenter positioning was significantly improved with the 3D camera ( P < 0.001) as compared with visual laser-guided positioning. Absolute table height differed significantly ( P < 0.001), being higher with camera positioning (165.6 ± 16.2 mm) as compared with laser-guided positioning (170.0 ± 20.4 mm). Radiation exposure decreased using the 3D camera as indicated by dose length product (321.1 ± 266.6 mGy·cm; camera off: 342.0 ± 280.7 mGy·cm; P = 0.033), effective dose (3.3 ± 2.7 mSv; camera off: 3.5 ± 2.9; P = 0.053), and CT dose index (6.4 ± 4.3 mGy; camera off: 6.8 ± 4.6 mGy; P = 0.011). Exposure of radiation-sensitive organs such as colon ( P = 0.015) and red bone marrow ( P = 0.049) were also lower using the camera. CONCLUSIONS: The introduction of a 3D camera improves patient positioning in the isocenter of the scanner, which results in a lower and also better balanced dose reduction for the patients.


Assuntos
Exposição à Radiação , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Doses de Radiação , Computadores , Posicionamento do Paciente/métodos
5.
Eur Radiol ; 32(8): 5525-5531, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35294584

RESUMO

The terms "notifications" and "alerts" for medical exposures are used by several national and international organisations. Recommendations for CT scanners have been published by the American Association of Physicists in Medicine. Some interventional radiology societies as well as national authorities have also published dose notifications for fluoroscopy-guided interventional procedures. Notifications and alerts may also be useful for optimisation and to avoid unintended and accidental exposures. The main interest in using these values for high-dose procedures (CT and interventional) is to optimise imaging procedures, reducing the probability of stochastic effects and avoiding tissue reactions. Alerts in X-ray systems may be considered before procedures (as in CT), during procedures (in some interventional radiology systems), and after procedures, when the patient radiation dose results are known and processed. This review summarises the different uses of notifications and alerts to help in optimisation for CT and for fluoroscopy-guided interventional procedures as well as in the analysis of unintended and accidental medical exposures. The paper also includes cautions in setting the alert values and discusses the benefits of using patient dose management systems for the alerts, their registry and follow-up, and the differences between notifications, alerts, and trigger levels for individual procedures and the terms used for the collective approach, such as diagnostic reference levels. KEY POINTS: • Notifications and alerts on patient dose values for computed tomography (CT) and fluoroscopy-guided interventional procedures (FGIP) allow to improve radiation safety and contribute to the avoidance of radiation injuries and unintended and accidental exposures. • Alerts may be established before the imaging procedures (as in CT) or during and after the procedures as for FGIP. • Dose management systems should include notifications and alerts and their registry for the hospital quality programmes.


Assuntos
Proteção Radiológica , Fluoroscopia/métodos , Humanos , Doses de Radiação , Proteção Radiológica/métodos , Radiografia Intervencionista , Radiologia Intervencionista/métodos , Tomografia Computadorizada por Raios X/métodos
6.
Rofo ; 194(4): 400-408, 2022 Apr.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-34933352

RESUMO

PURPOSE: According to the German legislation and regulation of radiation protection, i. e. Strahlenschutzgesetz und Strahlenschutzverordnung (StrlSchG and StrlSchV), which came into force on 31st December 2018, significant unintended or accidential exposures have to be reported to the competent authority. Furthermore, facilities have to implement measures to prevent and to recognize unintended or accidental exposures as well as to reduce their consequences. We developed a process to register incidents and tested its application in the framework of a multi-center-study. MATERIALS AND METHODS: Over a period of 12 months, 16 institutions for x-ray diagnostics and interventions, documented their incidents. Documentation of the incidents was conducted using the software CIRSrad, which was developed, released for testing purposes and implemented in the frame of the study. Reporting criteria of the project were selected to be more sensitive compared to the legal criteria specifying "significant incidents". Reported incidents were evaluated after four, eight, and twelve months. Finally, all participating institutions were interviewed on their experience with the software and the correlated effort. RESULTS: The rate of reported incidents varied between institutions as well as between modalities. The majority of incidents were reported in conventional x-ray imaging, followed by computed tomography and therapeutic interventions. Incidents were attributed to several different causes, amongst others to the technical setup and patient positioning (19 %) and patient movement or insufficient cooperativeness of the patient (18 %). Most incidents were below corresponding thresholds stated in StrlSchV. The workload for documenting the incidents was rated as appropriate. CONCLUSION: It is possible to monitor and handle incidents complient with legal requirements with an acceptable effort. The number of reported incidents can be increased by frequent trainings on the detection and the processing workflow, on the software and legal regulation as well as by a transparent error handling within the institution. KEY POINTS: · The software CIRSrad was developed to enable the present study and as prototype platform for a future radiological incident management system.. · 586 exceedances of thresholds were recorded by 16 facilities in a period of one year.. · Frequent trainings of all users increase the number of reported cases.. CITATION FORMAT: · Müller BS, Singer J, Stamm G et al. Handling of Incidents in the Clinical Application of Ionizing Radiation in Diagnostic and Interventional Radiology - a Multi-center Study. Fortschr Röntgenstr 2022; 194: 400 - 408.


Assuntos
Proteção Radiológica , Radiologia Intervencionista , Humanos , Radiação Ionizante , Radiografia , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA