Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
Sci Transl Med ; 16(747): eadl4497, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38748771

RESUMO

Endovascular interventions are increasingly becoming the preferred approach for treating strokes and cerebral artery diseases. These procedures rely on sophisticated angiographical imaging guidance, which encounters challenges because of limited contrast and spatial resolution. Achieving a more precise visualization of the underlying arterial pathology and neurovascular implants is crucial for accurate procedural decision-making. In a human study involving 32 patients, we introduced the clinical application of a miniaturized endovascular neuro optical coherence tomography (nOCT) imaging probe. This technology was designed to navigate the tortuous paths of the cerebrovascular circulation and to offer high-resolution imaging in situ. The nOCT probe is compatible with standard neurovascular microcatheters, integrating with the procedural workflow used in clinical routine. Equipped with a miniaturized optical fiber and a distal lens, the probe illuminates the tissue and collects the backscattered, near-infrared light. While rotating the fiber and the lens at high speed, the probe is rapidly retracted, creating a spiral-shaped light pattern to comprehensively capture the arterial wall and implanted devices. Using nOCT, we demonstrated volumetric microscopy of cerebral arteries in patients undergoing endovascular procedures. We imaged the anterior and posterior circulation of the brain, including distal segments of the internal carotid and middle-cerebral arteries, as well as the vertebral, basilar, and posterior cerebral arteries. We captured a broad spectrum of neurovascular pathologies, such as brain aneurysms, ischemic stroke, arterial stenoses, dissections, and intracranial atherosclerotic disease. nOCT offered artifact-free, high-resolution visualizations of intracranial artery pathology and neurovascular devices.


Assuntos
Artérias Cerebrais , Tomografia de Coerência Óptica , Tomografia de Coerência Óptica/métodos , Humanos , Artérias Cerebrais/diagnóstico por imagem , Microscopia/métodos , Miniaturização , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/métodos
2.
J Neurointerv Surg ; 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38719445

RESUMO

Intracranial atherosclerotic disease (ICAD) involves the build-up of atherosclerotic plaques in cerebral arteries, significantly contributing to stroke worldwide. Diagnosing ICAD entails various techniques that measure arterial stenosis severity. Digital subtraction angiography, CT angiography, and magnetic resonance angiography are established methods for assessing stenosis. High-resolution MRI offers additional insights into plaque morphology including plaque burden, hemorrhage, remodeling, and contrast enhancement. These metrics and plaque traits help identify symptomatic plaques. Techniques like transcranial Doppler, CT perfusion, computational fluid dynamics, and quantitative MRA analyze blood flow restrictions due to ICAD. Intravascular ultrasound or optical coherence tomography have a very high spatial resolution and can assess the structure of the arterial wall and the plaque from the lumen of the target vascular territory. Positron emission tomography could further detect inflammation markers. This review aims to provide a comprehensive overview of the spectrum of current modalities for atherosclerotic plaque analysis and risk stratification.

3.
J Neurointerv Surg ; 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37527927

RESUMO

BACKGROUND: Intrasaccular flow-disrupting devices are a safe and effective treatment strategy for intracranial aneurysms. We utilized high-frequency optical coherence tomography (HF-OCT) and digital subtraction angiography (DSA) to evaluate SEAL Arc, a new intrasaccular device, and compare the findings with the well-established Woven EndoBridge (WEB) device in an animal model of saccular aneurysms. METHODS: In a rabbit model, elastase-induced aneurysms were treated with SEAL Arc (n=11) devices. HF-OCT and DSA were performed after implant and repeated after 12 weeks. Device protrusion and malapposition were assessed at implant time and scored on a binary system. Aneurysm occlusion was assessed at 12 weeks with the WEB Occlusion Scale and dichotomized to complete (A and B) or incomplete (C and D) occlusion. The percentage of neointimal coverage after 12 weeks was quantified using HF-OCT. We compared these data to previously published historical controls treated with the gold-standard WEB device (n=24) in the same model. RESULTS: Aneurysm size and device placement were not significantly different between the two groups. Complete occlusion was demonstrated in 80% of the SEAL Arc devices, which compared favorably to the 21% of the aneurysms treated with WEB devices (P=0.002). Neointimal coverage across SEAL Arc devices was 86±15% compared with 49±27% for WEB (P=0.001). Protruding devices had significantly less neointimal coverage (P<0.001) as did incompletely occluded aneurysms (P<0.001). Histologically, all aneurysms treated with SEAL Arc devices were completely healed. CONCLUSION: Complete early aneurysm occlusion was frequently observed in the SEAL Arc treated aneurysms, with significant neointimal coverage after 12 weeks.

4.
J Neurointerv Surg ; 2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37399337

RESUMO

BACKGROUND: Flow diverters carry the risk of thromboembolic complications (TEC). We tested a coating with covalently bound heparin that activates antithrombin to address TEC by locally downregulating the coagulation cascade. We hypothesized that the neuroimaging evidence of TEC would be reduced by the coating. METHODS: 16 dogs were implanted with overlapping flow diverters in the basilar artery, separated into two groups: heparin-coated (n=9) and uncoated (n=7). Following implantation, high-frequency optical coherence tomography (HF-OCT) was acquired to quantify acute thrombus (AT) formation on the flow diverters. MRI was performed postoperatively and repeated at 1, 2, 3, 4, and 8 weeks, consisting of T1-weighted imaging, time-0f-flight (ToF), diffusion weighted imaging (DWI), susceptibility weighted imaging (SWI), and fluid attenuated inversion recovery (FLAIR) sequences. Neurological examinations were performed throughout the 8-week duration of the study. RESULTS: The mean AT volume on coated devices was lower than uncoated (0.014 vs 0.018 mm3); however, this was not significant (P=0.3). The mean number of foci of magnetic susceptibility artifacts (MSAs) on SWI was significantly different between the uncoated and coated groups at the 1-week follow-up (P<0.02), and remained statistically different throughout the duration of the study. The AT volume showed a direct linear correlation with the MSA count and 80% of the variance in the MSA could be explained by the AT volume (P<0.001). Pathological analysis showed evidence of ischemic injury at locations of MSA. CONCLUSIONS: Heparin-coated flow diverters significantly reduced the number of new MSAs after 1 week follow-up, showing the potential to reduce TEC.

5.
J Neurointerv Surg ; 2023 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-37402572

RESUMO

BACKGROUND: Flow diversion has become a standard treatment for cerebral aneurysms. However, major drawbacks include the need for dual antiplatelet therapy after implant and delayed complete occlusion of the aneurysm, which occurs when new tissue growth excludes the aneurysm from the parent artery. Biomimetic surface modifications such as the phosphorylcholine polymer (Shield surface modification) represent major advances in reducing thrombogenicity of these devices. However, in vitro studies have raised concerns that this modification may also delay endothelialization of flow diverters. METHODS: Bare metal Pipeline, Pipeline Shield, and Vantage with Shield devices were implanted in the common carotid arteries (CCAs) of 10 rabbits (two in the left CCA, one in the right CCA). Following implant and at 5, 10, 15, and 30 days, the devices were imaged with high-frequency optical coherence tomography and conventional angiography to evaluate tissue growth. At 30 days the devices were explanted and their endothelial growth was assessed with scanning electron microscopy (SEM) at five locations along their length using a semi-quantitative score. RESULTS: The average tissue growth thickness (ATGT) was not different between the three devices. Neointima was apparent at 5 days and all devices demonstrated similar ATGT at each time point. On SEM, no difference was found in the endothelium scores between the device types. CONCLUSION: In vivo, neither the Shield surface modification nor the device design (Vantage) altered the longitudinal healing of the flow diverter.

6.
J Clin Neurosci ; 113: 121-125, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37262981

RESUMO

BACKGROUND: Diagnosing and treating acute ischemic stroke patients within a narrow timeframe is challenging. Time needed to access the occluded vessel and initiate thrombectomy is dictated by the availability of information regarding vascular anatomy and trajectory. Absence of such information potentially impacts device selection, procedure success, and stroke outcomes. While the cervical vessels allow neurointerventionalists to navigate devices to the occlusion site, procedures are often encumbered due to tortuous pathways. The purpose of this retrospective study was to determine how neurointerventionalists consider the physical nature of carotid segments when evaluating a procedure's difficulty. METHODS: Seven neurointerventionalists reviewed 3D reconstructions of CT angiograms of left and right carotid arteries from 49 subjects and rated the perceived procedural difficulty on a three-point scale (easy, medium, difficult) to reach the targeted M1. Twenty-two vessel metrics were quantified by dividing the carotids into 5 segments and measuring the radius of curvature, tortuosity, vessel radius, and vessel length of each segment. RESULTS: The tortuosity and length of the arch-cervical and cervical regions significantly impacted difficulty ratings. Additionally, two-way interaction between the radius of curvature and tortuosity on the arch-cervical region was significant (p < 0.0001) wherein, for example, at a given arch-cervical tortuosity, an increased radius of curvature reduced the perceived case difficulty. CONCLUSIONS: Examining the vessel metrics and providing detailed vascular data tailored to patient characteristics may result in better procedure preparation, facilitate faster vessel access time, and improve thrombectomy outcomes. Additionally, documenting these correlations can enhance device design to ensure they suitably function under various vessel conditions.


Assuntos
Procedimentos Endovasculares , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Artéria Carótida Interna/diagnóstico por imagem , Artéria Carótida Interna/cirurgia , Estudos Retrospectivos , Imageamento Tridimensional , Trombectomia/métodos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/cirurgia , Resultado do Tratamento , Procedimentos Endovasculares/métodos
7.
Interv Neuroradiol ; : 15910199231158444, 2023 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-36872879

RESUMO

BACKGROUND: Neurointerventionalists use in-vitro vascular models to train for worst-case scenarios and test new devices in a simulated use environment to predict clinical performance. According to the Food and Drug Administration (FDA), any neurovascular navigation device should be able to successfully navigate two 360-degree turns and two 180-degree turns at the distal portion of the anatomical model. Here, we present a device benchmarking vascular model that complies with FDA recommendations. METHODS: Our vascular model was assembled from quantitative characterization of 49 patients who underwent CT angiography either for acute ischemic stroke caused by large vessel occlusion or for aneurysm treatment. Following complete characterization of these data, the vascular segments were 3D reconstructed from CT angiograms of 6 selected patients that presented with challenging anatomy. The curvature and total rotational angle were calculated for each segment and the anatomical parts that complied with FDA recommendations were fused together into a single in-vitro model. RESULTS: The model was constructed containing two common carotid branches arising from a type two aortic arch and the dimensions of the overall model exceeded the recommendations of the FDA. Two experienced neurointerventionalists tested the model for navigation difficulty using several devices on an in-vitro perfusion system and concluded that the model provided a realistic, challenging scenario. CONCLUSIONS: This model provides a first prototype designed according to FDA recommendations of cumulative angle while also integrating an aggregation of actual patient-specific anatomy. The availability of this clinically relevant benchmark model presents a potential standardized approach for neurovascular device testing.

8.
J Neurointerv Surg ; 15(12): 1207-1211, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36878688

RESUMO

BACKGROUND: The first-pass complete recanalization by mechanical thrombectomy (MT) for the treatment of stroke remains limited due to the poor integration of the clot within current devices. Aspiration can help retrieval of the main clot but fails to prevent secondary embolism in the distal arterial territory. The dense meshes of extracellular DNA, recently described in stroke-related clots, might serve as an anchoring platform for MT devices. We aimed to evaluate the potential of a DNA-reacting surface to aid the retention of both the main clot and small fragments within the thrombectomy device to improve the potential of MT procedures. METHODS: Device-suitable alloy samples were coated with 15 different compounds and put in contact with extracellular DNA or with human peripheral whole blood, to compare their binding to DNA versus blood elements in vitro. Clinical-grade MT devices were coated with two selected compounds and evaluated in functional bench tests to study clot retrieval efficacy and quantify distal emboli using an M1 occlusion model. RESULTS: Binding properties of samples coated with all compounds were increased for DNA (≈3-fold) and decreased (≈5-fold) for blood elements, as compared with the bare alloy samples in vitro. Functional testing showed that surface modification with DNA-binding compounds improved clot retrieval and significantly reduced distal emboli during experimental MT of large vessel occlusion in a three-dimensional model. CONCLUSION: Our results suggest that clot retrieval devices coated with DNA-binding compounds can considerably improve the outcome of the MT procedures in stroke patients.


Assuntos
Acidente Vascular Cerebral , Trombose , Humanos , Resultado do Tratamento , Trombectomia/métodos , Trombose/terapia , Acidente Vascular Cerebral/cirurgia , Ligas , DNA
9.
J Stroke Cerebrovasc Dis ; 32(3): 106985, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36640721

RESUMO

OBJECTIVES: Cell-free hemoglobin in the cerebrospinal fluid (CSF-Hb) may be one of the main drivers of secondary brain injury after aneurysmal subarachnoid hemorrhage (aSAH). Haptoglobin scavenging of CSF-Hb has been shown to mitigate cerebrovascular disruption. Using digital subtraction angiography (DSA) and blood oxygenation-level dependent cerebrovascular reactivity imaging (BOLD-CVR) the aim was to assess the acute toxic effect of CSF-Hb on cerebral blood flow and autoregulation, as well as to test the protective effects of haptoglobin. METHODS: DSA imaging was performed in eight anesthetized and ventilated sheep (mean weight: 80.4 kg) at baseline, 15, 30, 45 and 60 minutes after infusion of hemoglobin (Hb) or co-infusion with haptoglobin (Hb:Haptoglobin) into the left lateral ventricle. Additionally, 10 ventilated sheep (mean weight: 79.8 kg) underwent BOLD-CVR imaging to assess the cerebrovascular reserve capacity. RESULTS: DSA imaging did not show a difference in mean transit time or cerebral blood flow. Whole-brain BOLD-CVR compared to baseline decreased more in the Hb group after 15 minutes (Hb vs Hb:Haptoglobin: -0.03 ± 0.01 vs -0.01 ± 0.02) and remained diminished compared to Hb:Haptoglobin group after 30 minutes (Hb vs Hb:Haptoglobin: -0.03 ± 0.01 vs 0.0 ± 0.01), 45 minutes (Hb vs Hb:Haptoglobin: -0.03 ± 0.01 vs 0.01 ± 0.02) and 60 minutes (Hb vs Hb:Haptoglobin: -0.03 ± 0.02 vs 0.01 ± 0.01). CONCLUSION: It is demonstrated that CSF-Hb toxicity leads to rapid cerebrovascular reactivity impairment, which is blunted by haptoglobin co-infusion. BOLD-CVR may therefore be further evaluated as a monitoring strategy for CSF-Hb toxicity after aSAH.


Assuntos
Haptoglobinas , Hemorragia Subaracnóidea , Animais , Ovinos , Encéfalo/diagnóstico por imagem , Hemorragia Subaracnóidea/diagnóstico por imagem , Diagnóstico por Imagem , Circulação Cerebrovascular/fisiologia , Hemoglobinas , Imageamento por Ressonância Magnética/métodos
10.
J Neurointerv Surg ; 15(11): 1148-1154, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36609543

RESUMO

BACKGROUND: Preclinical testing of intracranial stents is currently performed in the peripheral circulation, and rarely in the basilar artery of the dog. OBJECTIVE: To test the feasibility of intracranial stenting in the middle cerebral artery (MCA) of the dog and explore the use of MRI to detect thromboembolic complications. METHODS: Six purpose-bred cross-hound dogs were used for proof-of-concept stenting of both MCAs in each animal. Immediately following the procedure, the animals were imaged with MRI. MRI was repeated weekly for 1 month. After the final angiography at 30 days, the animals were euthanized for pathological assessment of the stents and the brain. RESULTS: We successfully deployed 12 stents in the MCAs of all animals. We deployed three techniques for microcatheterization of the MCA-namely, directly through the internal carotid artery (ICA), using anastomotic arteries from the external carotid artery, or via the contralateral ICA through the anterior communicating artery. Two iatrogenic perforations of the ICA with formation of an arteriovenous fistula occurred, without clinical sequelae, which spontaneously resolved on follow-up. All animals tolerated the procedure and completed the follow-up surveillance. MRI revealed procedural thromboembolic induced areas of restricted diffusion, and only one instance of a delayed thromboembolic lesion during surveillance. At follow-up angiography, the devices were all patent. CONCLUSION: We describe a new preclinical model of intracranial stenting in the MCA. Such a model may prove useful for evaluating new surface modifications.

11.
J Neurointerv Surg ; 15(7): 664-668, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35732483

RESUMO

BACKGROUND: Super large-bore aspiration (SLBA) has shown high rates of complete clot ingestion. OBJECTIVE: To report the initial clinical feasibility, safety, and efficacy of this novel SLBA insert combination-super large-bore ingestion of clot (SLIC) technique for stroke. METHODS: We performed a retrospective review of three comprehensive stroke center databases. The SLIC technique entails a triaxial assembly of an 8 Fr 0.106″ Base Camp catheter, 0.088″ catheter extender (HiPoint), and an insert catheter (Tenzing 8) that completely consumes the inner diameter of the 0.088″ SLBA catheter. The HiPoint catheter is delivered over the Tenzing 8 to the face of the embolus, which is withdrawn, while aspirating through the Base Camp and HiPoint catheters as a single assembly. RESULTS: Thirty-three consecutive patients with large vessel occlusion were treated with SLIC. The median age was 70 years (30-91) and 17 were male (51.5%). The median presenting National Institutes of Health Stroke Scale score and Alberta Stroke Program Early CT score was 21 (1-34) and 8 (5-10), respectively. There was 100% success in delivering the 0.088″ catheter to the site of the occlusion. The successful revascularization rate (modified Thrombolysis in Cerebral Infarction (mTICI) score ≥2B) was 100% within a single pass in most cases (82%). Final mTICI ≥2C was achieved in 94.1% of occlusions, with 73.5% mTICI 3 recanalization. The rate of first pass effect in achieving excellent reperfusion (mTICI ≥2C) was 70.5%. There were no adverse events or postprocedural symptomatic hemorrhages. CONCLUSIONS: Our initial experience with the SLIC technique resulted in achieving a first pass effect (mTICI ≥2C) in 70.5%. Navigation of the SLBA catheter extender over the Tenzing insert was successful and safe in this early experience.


Assuntos
Isquemia Encefálica , Acidente Vascular Cerebral , Trombose , Humanos , Masculino , Idoso , Feminino , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/cirurgia , Trombectomia/métodos , Infarto Cerebral , Estudos Retrospectivos , Catéteres , Ingestão de Alimentos , Resultado do Tratamento , Isquemia Encefálica/terapia
12.
J Neurointerv Surg ; 15(9): 919-923, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36002288

RESUMO

BACKGROUND: High-frequency optical coherence tomography (HF-OCT) is an intravascular imaging method that allows for volumetric imaging of flow diverters in vivo. OBJECTIVE: To examine the hypothesis that a threshold for both volume and area of communicating malapposition can be predictive of early aneurysm occlusion. METHODS: Fifty-two rabbits underwent elastase aneurysm formation, followed by treatment with a flow diverter. At the time of implant, HF-OCT was acquired to study the rate and degree of communicating malapposition. Treated aneurysms were allowed to heal for either 90 or 180 days and euthanized following catheter angiography. Healing was dichotomized into aneurysm remnant or neck remnant/complete occlusion. Communicating malapposition was measured by HF-OCT using a semi-automatic algorithm able to detect any points where the flow diverter was more than 50 µm from the vessel wall. This was then summed across image slices to either a volume or area. Finally, a subsampled population was used to train a statistical classifier for the larger dataset. RESULTS: No difference in occlusion rate was found between device type or follow-up time (p=0.28 and p=0.67, respectively). Both volume and area of malapposition were significantly lower in aneurysms with a good outcome (p<0.001, both). From the statistical model, a volume of less than 0.56 mm3 or a normalized area less than 0.69 as quantified by HF-OCT was predictive of occlusion (p<0.001, each). CONCLUSIONS: HF-OCT allows for measurements of both volume and area of malapposition and, from these measurements, an accurate prediction for early aneurysm occlusion can be made.


Assuntos
Procedimentos Endovasculares , Aneurisma Intracraniano , Animais , Coelhos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Tomografia de Coerência Óptica/métodos , Stents , Procedimentos Endovasculares/métodos , Angiografia Cerebral/métodos , Resultado do Tratamento
14.
Stroke ; 53(4): 1363-1372, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35306836

RESUMO

BACKGROUND: Tissue hypoxia plays a critical role in the events leading to cell death in ischemic stroke. Despite promising results in preclinical and small clinical pilot studies, inhaled oxygen supplementation has not translated to improved outcomes in large clinical trials. Moreover, clinical observations suggest that indiscriminate oxygen supplementation can adversely affect outcome, highlighting the need to develop novel approaches to selectively deliver oxygen to affected regions. This study tested the hypothesis that intravenous delivery of a novel oxygen carrier (Omniox-Ischemic Stroke [OMX-IS]), which selectively releases oxygen into severely ischemic tissue, could delay infarct progression in an established canine thromboembolic large vessel occlusion stroke model that replicates key dynamics of human infarct evolution. METHODS: After endovascular placement of an autologous clot into the middle cerebral artery, animals received OMX-IS treatment or placebo 45 to 60 minutes after stroke onset. Perfusion-weighted magnetic resonance imaging was performed to define infarct progression dynamics to stratify animals into fast versus slow stroke evolvers. Serial diffusion-weighted magnetic resonance imaging was performed for up to 5 hours to quantify infarct evolution. Histology was performed postmortem to confirm final infarct size. RESULTS: In fast evolvers, OMX-IS therapy substantially slowed infarct progression (by ≈1 hour, P<0.0001) and reduced the final normalized infarct volume as compared to controls (0.99 versus 0.88, control versus OMX-IS drug, P<0.0001). Among slow evolvers, OMX-IS treatment delayed infarct progression by approximately 45 minutes; however, this did not reach statistical significance (P=0.09). The final normalized infarct volume also did not show a significant difference (0.93 versus 0.95, OMX-IS drug versus control, P=0.34). Postmortem histologically determined infarct volumes showed excellent concordance with the magnetic resonance imaging defined ischemic lesion volume (bias: 1.33% [95% CI, -15% to 18%). CONCLUSIONS: Intravenous delivery of a novel oxygen carrier is a promising approach to delay infarct progression after ischemic stroke, especially in treating patients with large vessel occlusion stroke who cannot undergo definitive reperfusion therapy within a timely fashion.


Assuntos
Isquemia Encefálica , Acidente Vascular Cerebral , Animais , Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/tratamento farmacológico , Isquemia Encefálica/patologia , Cães , Humanos , Infarto , Imageamento por Ressonância Magnética/métodos , Oxigênio , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/tratamento farmacológico
15.
J Neurointerv Surg ; 14(5)2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35115394

RESUMO

BACKGROUND: The micro-architectonics of the subarachnoid space (SAS) remain partially understood and largely ignored, likely the result of the inability to image these structures in vivo. We explored transvascular imaging with high-frequency optical coherence tomography (HF-OCT) to interrogate the SAS. METHODS: In vivo HF-OCT was performed in 10 dogs in both the posterior and anterior cerebral circulations. The conduit vessels used were the basilar, anterior spinal, and middle and anterior cerebral arteries through which the perivascular SAS was imaged. The HF-OCT imaging probe was introduced via a microcatheter and images were acquired using a contrast injection (3.5 mL/s) for blood clearance. Segmentation and three-dimensional rendering of HF-OCT images were performed to study the different configurations and porosity of the subarachnoid trabeculae (SAT) as a function of location. RESULTS: Of 13 acquisitions, three were excluded due to suboptimal image quality. Analysis of 15 locations from seven animals was performed showing six distinct configurations of arachnoid structures in the posterior circulation and middle cerebral artery, ranging from minimal presence of SAT to dense networks and membranes. Different locations showed predilection for specific arachnoid morphologies. At the basilar bifurcation, a thick, fenestrated membrane had a unique morphology. SAT average thickness was 100 µm and did not vary significantly based on location. Similarly, the porosity of the SAT averaged 91% and showed low variability. CONCLUSION: We have demonstrated the feasibility to image the structures of the SAS with transvascular HF-OCT. Future studies are planned to further map the SAT to increase our understanding of their function and possible impact on neurovascular pathologies.


Assuntos
Espaço Subaracnóideo , Tomografia de Coerência Óptica , Animais , Cães , Humanos , Microscopia Intravital , Microcirurgia/métodos , Espaço Subaracnóideo/anatomia & histologia , Espaço Subaracnóideo/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos
16.
J Biomech ; 130: 110894, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34915309

RESUMO

Mechanical thrombectomy to treat large vessel occlusions (LVO) causing a stroke is one of the most effective treatments in medicine, with a number needed to treat to improve clinical outcomes as low as 2.6. As the name implies, it is a mechanical solution to a blocked artery and modeling these mechanics preclinically for device design, regulatory clearance and high-fidelity physician training made clinical applications possible. In vitro simulation of LVO is extensively used to characterize device performance in representative vascular anatomies with physiologically accurate hemodynamics. Embolus analogues, validated against clots extracted from patients, provide a realistic simulated use experience. In vitro experimentation produces quantitative results such as particle analysis of distal emboli generated during the procedure, as well as pressure and flow throughout the experiment. Animal modeling, used mostly for regulatory review, allows estimation of device safety. Other than one recent development, nearly all animal modeling does not incorporate the desired target organ, the brain, but rather is performed in the extracranial circulation. Computational modeling of the procedure remains at the earliest stages but represents an enormous opportunity to rapidly characterize and iterate new thrombectomy concepts as well as optimize procedure workflow. No preclinical model is a perfect surrogate; however, models available can answer important questions during device development and have to date been successful in delivering efficacious and safe devices producing excellent clinical outcomes. This review reflects on the developments of preclinical modeling of mechanical thrombectomy with particular focus on clinical translation, as well as articulate existing gaps requiring additional research.


Assuntos
Embolia , Embolia Intracraniana , Acidente Vascular Cerebral , Animais , Humanos , Acidente Vascular Cerebral/terapia , Trombectomia , Resultado do Tratamento
17.
Neuroscience ; 474: 134-144, 2021 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-34126186

RESUMO

Diagnosis of cerebrovascular disease includes vascular neuroimaging techniques such as computed tomography (CT) angiography, magnetic resonance (MR) angiography (with or without use of contrast agents) and catheter digital subtraction angiography (DSA). These techniques provide mostly information about the vessel lumen. Vessel wall imaging with MR seeks to characterize cerebrovascular pathology, but with resolution that is often insufficient for small lesions. Intravascular imaging techniques such as ultrasound and optical coherence tomography (OCT), used for over a decade in the peripheral circulation, is not amendable to routine deployment in the intracranial circulation due to vessel caliber and tortuosity. However, advances in OCT technology including the probe profile, stiffness and unique distal rotation solution, holds the promise for eventual translation of OCT into the clinical arena. As such, it is apropos to review this technology and present the rationale for utilization of OCT in the cerebrovasculature.


Assuntos
Aneurisma Intracraniano , Tomografia de Coerência Óptica , Angiografia Digital , Meios de Contraste , Humanos , Angiografia por Ressonância Magnética
18.
J Neurointerv Surg ; 13(7): 669-673, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32989033

RESUMO

BACKGROUND: High-frequency optical coherence tomography (HF-OCT) is an intra-vascular imaging technique capable of assessing device-vessel interactions at spatial resolution approaching 10 µm. We tested the hypothesis that adequately deployed Woven EndoBridge (WEB) devices as visualized by HF-OCT lead to higher aneurysm occlusion rates. METHODS: In a leporine model, elastase-induced aneurysms (n=24) were treated with the WEB device. HF-OCT and digital subtraction angiography (DSA) were performed following WEB deployment and repeated at 4, 8, and 12 weeks. Protrusion (0-present, 1-absent) and malapposition (0-malapposed, 1-neck apposition >50%) were binary coded. A device was considered 'adequately deployed' by HF-OCT and DSA if apposed and non-protruding. Aneurysm healing on DSA was reported using the 4-point WEB occlusion score: A or B grades were considered positive outcome. Neointimal coverage was quantified on HF-OCT images at 12 weeks and compared with scanning electron microscopy (SEM). RESULTS: Adequate deployment on HF-OCT correlated with positive outcome (P=0.007), but no statistically significant relationship was found between good outcome and adequate deployment on DSA (P=0.289). Absence of protrusion on HF-OCT correlated with a positive outcome (P=0.006); however, malapposition alone had no significant relationship (P=0.19). HF-OCT showed a strong correlation with SEM for the assessment of areas of neointimal tissue (R²=0.96; P<0.001). More neointimal coverage of 78%±32% was found on 'adequate deployment' cases versus 31%±24% for the 'inadequate deployment' cases (P=0.001). CONCLUSION: HF-OCT visualizes features that can determine adequate device deployment to prognosticate early aneurysm occlusion following WEB implantation and can be used to longitudinally monitor aneurysm healing progression.


Assuntos
Angiografia Digital/métodos , Embolização Terapêutica/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Stents Metálicos Autoexpansíveis , Tomografia de Coerência Óptica/métodos , Animais , Embolização Terapêutica/instrumentação , Aneurisma Intracraniano/induzido quimicamente , Masculino , Elastase Pancreática/toxicidade , Coelhos , Resultado do Tratamento
19.
Cardiovasc Intervent Radiol ; 44(2): 318-324, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33179161

RESUMO

PURPOSE: The first-pass effect during mechanical thrombectomy improves clinical outcomes regardless of first-line treatment approach, but current success rates for complete clot capture with one attempt are still less than 40%. We hypothesize that the ThrombX retriever (ThrombX Medical Inc.) can better engage challenging clot models during retrieval throughout tortuous vasculature in comparison with a standard stent retriever without increasing distal emboli. MATERIALS AND METHODS: Thrombectomy testing with the new retriever as compared to the Solitaire stent retriever was simulated in a vascular replica with hard and soft clot analogs to create a challenging occlusive burden. Parameters included analysis of distal emboli generated per clot type, along with the degree of recanalization (complete, partial or none) by retrieval device verified by angiography. RESULTS: The ThrombX device exhibited significantly higher rates of first-pass efficacy (90%) during hard clot retrieval in comparison with the control device (20%) (p < 0.009), while use of both techniques during soft clot retrieval resulted in equivalent recanalization. The soft clot model generated higher numbers of large emboli (>200 µm) across both device groups (p = 0.0147), and no significant differences in numbers of distal emboli were noted between the ThrombX and Solitaire techniques. CONCLUSIONS: Irrespective of clot composition, use of the ThrombX retriever demonstrated high rates of complete recanalization at first pass in comparison with a state-of-the-art stent retriever and proved to be superior in the hard clot model. Preliminary data suggest that risk of distal embolization associated with the ThrombX system is comparable to that of the control device.


Assuntos
Embolia Intracraniana/cirurgia , Trombectomia/instrumentação , Trombectomia/métodos , Desenho de Equipamento , Estudos de Avaliação como Assunto , Humanos , Embolia Intracraniana/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Resultado do Tratamento
20.
J Neurointerv Surg ; 13(9): 823-826, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33024028

RESUMO

BACKGROUND: Direct aspiration thrombectomy techniques use large bore aspiration catheters for mechanical thrombectomy. Several aspiration catheters are now available. We report a bench top exploration of a novel beveled tip catheter and our experience in treating large vessel occlusions (LVOs) using next-generation aspiration catheters. METHODS: A retrospective analysis from a prospectively maintained database comparing the bevel shaped tip aspiration catheter versus non-beveled tip catheters was performed. Patient demographics, periprocedural metrics, and discharge and 90-day modified Rankin Scale (mRS) scores were collected. Patients were divided into two groups based on which aspiration catheter was used. RESULTS: Our data showed no significant difference in age, gender, IV tissue plasminogen activator administration, admission NIH Stroke Scale score, baseline mRS, or LVO location between the beveled tip and flat tip groups. With the beveled tip, Thrombolysis in Cerebral Infarction (TICI) 2C or better recanalization was more frequent overall (93.2% vs 74.2%, p=0.017), stent retriever usage was lower (9.1% vs 29%, p=0.024), and patients had lower mRS on discharge (median 3 vs 4, p<0.001) and at 90 days (median 2 vs 4, p=0.008). CONCLUSION: Patients who underwent mechanical thrombectomy with the beveled tip catheter had a higher proportion of TICI 2C or better and had a significantly lower mRS score on discharge and at 90 days.


Assuntos
Isquemia Encefálica , AVC Isquêmico , Acidente Vascular Cerebral , Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/cirurgia , Catéteres , Humanos , Estudos Retrospectivos , Stents , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/cirurgia , Trombectomia , Ativador de Plasminogênio Tecidual , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...