Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Food Chem ; 322: 126771, 2020 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-32305875

RESUMO

The aim of the present study was to determine and compare the levels of acrylamide in different types of bread and bakery products using a LC-MS/MS method, before and after the new European regulation on acrylamide reduction (Commission Regulation (EU) 2017/2158) became valid. Also, one of the aim was to estimate the average exposure to acrylamide through this food category. Of the total of 100 analysed samples, acrylamide content ranged from below the limit of quantification (LOQ) to 237 µg/kg in the period before the application of a new European Regulation, and from

Assuntos
Acrilamida/análise , Pão/análise , Exposição Dietética/análise , Contaminação de Alimentos/análise , Acrilamida/efeitos adversos , Adulto , Cromatografia Líquida , Croácia , Inocuidade dos Alimentos , Humanos , Espectrometria de Massas em Tandem
2.
Psychiatr Danub ; 26 Suppl 3: 537-45, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25536994

RESUMO

BACKGROUND: Honey is used for nutritional, medicinal and industrial purposes and antibiotic residues may harm its quality and constitute a danger to human health. The broad spectrum antibiotic chloramphenicol (CAP) was used for curative purposes in veterinary medicine, but is now forbidden in European Union (EU) because of its many serious side effects (e.g. aplastic anaemia, grey syndrome, severe bone marrow depression and hypersensitivity). The aim of this study was to facilitate analyses of the quality and safety of Croatian honey distributed to whole European Union market; an assessment that has not previously been made. SUBJECTS AND METHODS: CAP in honey was qualifying and quantifying by validated liquid chromatography tandem mass spectrometry with negative electrospray ionisation method (LC-MS/MS). The target antibiotic was separated on chromatographic column Zorbax SB C18 (150 mm x 2.1 mm, 3.5 µm) with a gradient elution using acetonitrile - 0.1% formic acid mobile phase at a flow rate of 0.3 mL/min, with column temperature 35°C for CAP and 5D-CAP as internal standard. Homogenised honey samples were diluted with acetate buffer solution and extracted on Oasis Hydrophilic-Lipophilic-Balanced (HLB) sorbents. The method was used to analyse 280 domestic honey samples collected throughout Croatia between 2005.-2013. RESULTS: Recoveries of the method for real (acacia, chestnut, linden and flower) honey samples were 102% with RSD 8.4%. The value CCα and CCß were 0.09 and 0.12 µg/kg, respectively. Results showed only three subsequent positive detections (1.1%) of CAP in honey. CONCLUSIONS: Analysed honey samples from Croatia showed good quality and safety what is the one of the main objective in consumer health policy in EU.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...