Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
IEEE Trans Biomed Eng ; 68(11): 3290-3300, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-33784613

RESUMO

OBJECTIVE: In this study, we have used whole heart simulations parameterized with large animal experiments to validate three techniques (two from the literature and one novel) for estimating epicardial and volumetric conduction velocity (CV). METHODS: We used an eikonal-based simulation model to generate ground truth activation sequences with prescribed CVs. Using the sampling density achieved experimentally we examined the accuracy with which we could reconstruct the wavefront, and then examined the robustness of three CV estimation techniques to reconstruction related error. We examined a triangulation-based, inverse-gradient-based, and streamline-based techniques for estimating CV cross the surface and within the volume of the heart. RESULTS: The reconstructed activation times agreed closely with simulated values, with 50-70% of the volumetric nodes and 97-99% of the epicardial nodes were within 1 ms of the ground truth. We found close agreement between the CVs calculated using reconstructed versus ground truth activation times, with differences in the median estimated CV on the order of 3-5% volumetrically and 1-2% superficially, regardless of what technique was used. CONCLUSION: Our results indicate that the wavefront reconstruction and CV estimation techniques are accurate, allowing us to examine changes in propagation induced by experimental interventions such as acute ischemia, ectopic pacing, or drugs. SIGNIFICANCE: We implemented, validated, and compared the performance of a number of CV estimation techniques. The CV estimation techniques implemented in this study produce accurate, high-resolution CV fields that can be used to study propagation in the heart experimentally and clinically.


Assuntos
Sistema de Condução Cardíaco , Coração , Animais , Simulação por Computador , Coração/diagnóstico por imagem , Sistema de Condução Cardíaco/diagnóstico por imagem
2.
Artigo em Inglês | MEDLINE | ID: mdl-32123687

RESUMO

INTRODUCTION: Changes in conduction velocity are indicative of a wide variety of cardiac abnormalities yet measuring conduction velocity is challenging, especially within the myocardial volume. In this study we investigated a novel technique to reconstruct activation fronts and estimate three-dimensional (3D) conduction velocity (CV) from experimental intramural recordings. METHODS: From the intermittently sampled electrograms we both reconstruct the activation profile and compute the reciprocal of the gradient of activation times and a series of streamlines that allows for the CV estimation. RESULTS: The reconstructed activation times agreed closely with simulated values, with 50% to 70% of the nodes ≤ 1ms of absolute error. We found close agreement between the CVs calculated using reconstructed versus simulated activation times. Across the reconstructed stimulation sites we saw that the reconstructed CV was on average 3.8% different than the ground truth CV. DISCUSSION: This study used simulated datasets to validate our methods for reconstructing 3D activation fronts and estimating conduction velocities. Our results indicate that our method allows accurate reconstructions from sparse measurements, thus allowing us to examine changes in activation induced by experimental interventions such as acute ischemia, ectopic pacing, or drugs.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA