Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 98(3): E436-E443, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33512085

RESUMO

BACKGROUND: Monitored anesthesia care (MAC) has become more widely used during transcatheter aortic valve replacement (TAVR) to avoid the complications of general anesthesia (GA). METHODS: We included consecutive patients who underwent transfemoral-TAVR at our institution between January 2012 and April 2017. We compared outcomes with GA versus MAC. RESULTS: Of 998 patients, MAC was used in 43.9%. MAC was associated with shorter procedural time (96.9 ± 30.9 vs. 135 ± 64.6 mins; p < .001), fluoroscopy time (20.4 ± 8.9 vs. 29 ± 18.7 mins; p < .001), lower contrast volume (45.5 ± 27 vs. 60.4 ± 43 cc; p < .001), and decreased radiation exposure (12,869 ± 8,099 vs. 20,630 ± 16,276 cGy-cm2 ; p < .001). Patients who underwent MAC had a briefer median (IQR) intensive care unit stay [23.3 (21-24) vs. 23.4 (20.8-26) hrs; p < .001], and hospital stay [2 (2, 3) vs. 3 (2-6) days; p < .001], and were more frequently discharged to home (93.4% vs. 82.9%; p < .001). MAC was associated with lower mortality at 30 days (0.5% vs. 2.9%; log-rank p = .012; adjHR 0.22, 95% CI 0.06-0.82; p = .024), but not at 1 year (11.7% vs. 14.6%; log-rank p = .157) or 3 years (36.8% vs. 38.4%; log-rank p = 0.433). There were no differences in major adverse cardiac and cerebrovascular events (MACCE) at either 30 days (4.6% vs. 9.3%; log-rank p = .14) or 1 year (21.1% vs. 21.5%; log-rank p = .653). Similar findings were seen among patients who received newer-generation SAPIEN-3 valves. CONCLUSION: Utilizing MAC and omitting intraprocedural transesophageal echocardiography during TAVR seems to be more efficient without compromising safety. Better TAVR outcomes can be achieved with newer generation valves without needing GA.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Anestesia Geral/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Fluoroscopia , Humanos , Tempo de Internação , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
2.
Circ Cardiovasc Interv ; 11(9): e006664, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30354591

RESUMO

BACKGROUND: The Society of Thoracic Surgeons (STS) scores are used to screen patients for transcatheter aortic valve replacement (TAVR). The STS scores were also used to risk stratify patients in major TAVR trials. This study evaluates the reclassification of predicted risk of mortality by the currently available online STS score calculator compared with the 2008 STS risk model in patients undergoing TAVR. METHODS AND RESULTS: All patients who underwent TAVR from 2006 to 2016 were included in the study. The STS scores for all included patients were calculated by applying the 2008 STS risk model and again using the current STS online calculator. Among 1209 patients who underwent TAVR, 30-day mortality was 27 (2.2%). The overall predicted risk of mortality estimated by using the current online STS risk calculator was significantly lower than the 2008 STS risk model (6.3±4.4 vs 7.3±4.9; P<0.001). A total of 235 (19%) patients were reclassified into a lower risk category per the current STS risk model. In a multivariable logistic regression analysis, patients with persistent atrial fibrillation (odds ratio, 1.4; 95% CI, 1.0-1.9; P=0.03), chronic heart failure (odds ratio, 6.0; 95% CI, 3.8-10.1; P<0.001), and New York Heart Association class IV heart failure (odds ratio, 2.4; 95% CI, 1.3-4.4; P=0.007) were more likely to be reclassified into a lower risk category per the current STS risk model. CONCLUSIONS: The current STS calculation method produces significantly lower predicted risk of mortality than the 2008 calculator, more pronounced in patients with certain comorbid conditions. These results should be considered while evaluating data from prior studies of TAVR.


Assuntos
Valva Aórtica/cirurgia , Técnicas de Apoio para a Decisão , Doenças das Valvas Cardíacas/cirurgia , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso , Idoso de 80 Anos ou mais , Tomada de Decisão Clínica , Comorbidade , Feminino , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/mortalidade , Humanos , Masculino , Seleção de Pacientes , Valor Preditivo dos Testes , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
3.
Eur J Heart Fail ; 17(11): 1161-71, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26467180

RESUMO

AIMS: The goal of the study was to examine the prognostic impact, haemodynamic and clinical features associated with lung congestion in patients with chronic heart failure (HF). METHODS AND RESULTS: HF patients (n = 186) and HF-free controls (n = 21) underwent right heart catheterization, echocardiography, pulmonary function testing and chest radiography that was blindly scored for the presence and severity of lung oedema. Lung congestion correlated directly with pulmonary vascular resistance (PVR, P = 0.004) and inversely with pulmonary artery (PA) compliance (P < 0.001) and the diffusion limit for carbon monoxide (DLCO , P = 0.009). Compared with dry lung HF, wet lung HF patients (congestion score > median) had 25% lower PA compliance and 25-35% higher PVR, transpulmonary gradients and PA pressures (40 vs. 32 mmHg, P < 0.001) despite marginally higher PA wedge pressure (PAWP; 22 vs. 19 mmHg, P = 0.002). Wet lung HF patients displayed more right ventricular (RV) dilatation and dysfunction, more restrictive ventilation and greater reduction of DLCO . The strongest correlates of lung congestion were NT-proBNP, haemoglobin, albumin, and glomerular filtration, all surpassing PAWP. After a median of 333 days (interquartile range 80-875), 59 patients (32%) died. Lung congestion was associated with reduced survival (P < 0.0001), even after adjusting for PAWP, NT-proBNP, anaemia, CAD and renal dysfunction. CONCLUSION: Interstitial lung oedema is associated with pulmonary vascular disease, RV overload and dysfunction and increased mortality in HF. These data reinforce the importance of aggressive decongestion in HF and suggest that novel agents aimed at reducing lung water may help to deter progression of pulmonary vascular disease and biventricular HF.


Assuntos
Insuficiência Cardíaca , Hipertensão Pulmonar , Edema Pulmonar , Resistência Vascular , Disfunção Ventricular Direita/fisiopatologia , Idoso , Cateterismo Cardíaco/métodos , Ecocardiografia/métodos , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/fisiopatologia , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Prognóstico , Edema Pulmonar/sangue , Edema Pulmonar/diagnóstico , Edema Pulmonar/etiologia , Edema Pulmonar/mortalidade , Edema Pulmonar/fisiopatologia , Radiografia , Testes de Função Respiratória/métodos , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Estatística como Assunto , Análise de Sobrevida , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA