Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
1.
Am Heart J ; 269: 56-71, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38109985

RESUMO

BACKGROUND: To date, there are no randomized, double-blinded clinical trials comparing catheter ablation to DC cardioversion (DCCV) with medical therapy in patients with persistent atrial fibrillation (PersAF). Conducting a large-scale trial to address this question presents considerable challenges, including recruitment, blinding, and implementation. We conducted a pilot study to evaluate the feasibility of conducting a definitive placebo-controlled trial. METHODS: This prospective trial was carried out at Barts Heart Centre, United Kingdom, employing a randomized, double-blinded, placebo-controlled design. Twenty patients with PersAF (duration <2 years) were recruited, representing 10% of the proposed larger trial as determined by a power calculation. The patients were randomized in a 1:1 ratio to receive either PVI ± DCCV (PVI group) or DCCV + Placebo (DCCV group). The primary endpoint of this feasibility study was to evaluate patient blinding. Patients remained unaware of their treatment allocation until end of study. RESULTS: During the study, 35% of patients experienced recurrence of PersAF prior to completion of 12 months follow-up. Blinding was successfully maintained amongst both patients and medical staff. The DCCV group had a trend to higher recurrence and repeat procedure rate compared to the PVI group (recurrence of PersAF 60% vs 30%; p = .07 and repeat procedure 70% vs 40%; p = .4). The quality of life experienced by individuals in the PVI group showed improvement, as evidenced by enhanced scores on the AF specific questionnaire (AF PROMS) (3 [±4] vs 21 [±8]) and SF-12 mental-component raw score (51.4 [±7] vs 43.24 [±15]) in patients who maintained sinus rhythm at 12 months. CONCLUSION: This feasibility study establishes the potential for conducting a blinded, placebo-controlled trial to evaluate the efficacy of PVI versus DCCV in patients with PersAF.


Assuntos
Angina Estável , Fibrilação Atrial , Ablação por Cateter , Intervenção Coronária Percutânea , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Estudos de Viabilidade , Qualidade de Vida , Estudos Prospectivos , Angina Estável/cirurgia , Projetos Piloto , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos , Resultado do Tratamento , Recidiva
2.
Eur Heart J Case Rep ; 7(9): ytad411, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37743895

RESUMO

Background: Coronary compromise is a serious potential complication following catheter ablation; however, procedural details in the literature are often lacking, preventing the identification of learning opportunities. Case summary: We report two cases of right coronary compromise following catheter ablation for symptomatic supraventricular tachycardia. After radiofrequency energy delivery at the coronary sinus ostium in both cases, inferior lead ST-elevation was observed. Diagnostic coronary angiography identified an occluded posterior left ventricular branch of the coronary artery, and optical coherence tomography demonstrated a high thrombus burden at this location. Electrocardiographic ST-segments settled with implantation of a drug-eluting stent. Discussion: Coronary compromise was likely secondary to energy delivery during catheter ablation. This case series highlights the need for electrophysiologist to understand coronary anatomy relative to anatomical landmarks, to anticipate the risk of vascular injury as physical distance from the site of ablation is likely important. Risk for coronary compromise, while a rare complication, needs to be discussed with patients during the consenting process. We also demonstrate the importance of an efficient multi-disciplinary team process for managing acute procedural complications.

3.
J Cardiovasc Electrophysiol ; 34(6): 1350-1359, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36598422

RESUMO

INTRODUCTION: The Heliostar™ ablation system is a novel RF balloon ablation technology with an integrated three-dimensional mapping system. Here, we describe our early experience and procedural outcomes using this technology for atrial fibrillation catheter ablation. METHODS: We sought to comprehensively assess the first 60 consecutive patients undergoing pulmonary vein isolation using the novel HELISOTAR™ RF balloon technology including procedural outcomes. A comparison of the workflow between two different anaesthetic modalities (conscious sedation [CS] vs. general anaesthesia [GA]) was made. Procedural data were collected prospectively from two high-volume centers (Barts Heart Centre, UK and University Hospital of Zurich, Zurich). A standardized approach for catheter ablation was employed. RESULTS: A total of 35 patients had the procedure under CS and the remaining under GA. Mean procedural and fluoroscopy times were 84 ± 33 min and 1.1 min. The median duration of RF energy application was 7 (5-9.8) mins per patient. All veins were successfully isolated, and the median isolation time was 10 (7-15) seconds. Our cohort's rate of procedural complications was low, with no mortality within 30 days postprocedure. CONCLUSION: Our early experience shows that catheter ablation using the Heliostar™ technology can be performed efficiently and safely; however, long-term data is yet to be established. Low fluoroscopy requirements, short learning curves and use of this technology with CS is possible, including the use of an oesophageal temperature probe.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Europa (Continente) , Eletrodos , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
4.
Europace ; 24(9): 1420-1429, 2022 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-35737685

RESUMO

AIM: Evaluate the novel PolarX Cryoballoon in atrial fibrillation (AF) catheter ablation through a propensity-matched comparison with the Arctic Front Advance (AFA). The aim was also to identify cryoablation metrics that are predictive of successful pulmonary vein isolation (PVI) with the PolarX Cryoballoon. METHODS AND RESULTS: This prospective multi-centre study included patients that underwent cryoablation for AF. All patients underwent PVI with reconnection assessed after a 30-min waiting period and adenosine. Safety, efficacy, and cryoablation metrics were compared between PolarX and a propensity-matched AFA cohort. Seventy patients were included with 278 veins treated. In total, 359 cryoablations were performed (1.3 ± 0.6 per vein) to achieve initial PVI with 205 (73.7%) veins isolating with a single cryoablation. Independent predictors for achieving initial PVI included temperature at 30 s [odds ratio (OR) 1.26; P = 0.003] and time to reach -40°C (OR 1.88; P < 0.001) with an optimal cut-off of ≤-38.5°C at 30 s [area under the curve (AUC) 0.79; P < 0.001] and ≤-40°C at ≤32.5 s (AUC 0.77; P < 0.001), respectively. Of the 278 veins, 46 (16.5%) veins showed acute reconnection. Temperature at 30 s (≤-39.5°C, OR 1.24; P = 0.002), nadir temperature (≤-53.5°C, OR 1.35; P = 0.003), and time to isolation (≤38.0 s, OR 1.18; P = 0.009) were independent predictors of sustained PVI. Combining two of these three targets was associated with reconnection in only 2-5% of PVs. Efficacy and safety of the PolarX Cryoballoon were comparable to AFA Cryoballoon, however, cryoablation metrics were significantly different. CONCLUSIONS: The PolarX Cryoballoon has a different cryoablation profile to AFA Cryoballoon. Prospective testing of these proposed targets in large outcomes studies is required.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Adenosina , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Benchmarking , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Humanos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Fatores de Tempo , Resultado do Tratamento
5.
J Interv Card Electrophysiol ; 63(2): 259-266, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33638777

RESUMO

PURPOSE: A significant proportion of patients undergoing catheter ablation for atrial fibrillation (AF) experience arrhythmia recurrence. This is mostly due to pulmonary vein reconnection (PVR). Whether mapping using High-Density Wave (HDW) technology is superior to standard bipolar (SB) configuration at detecting PVR is unknown. We aimed to evaluate the efficacy of HDW technology compared to SB mapping in identifying PVR. METHODS: High-Density (HD) multipolar Grid catheters were used to create left atrial geometries and voltage maps in 36 patients undergoing catheter ablation for AF (either due to recurrence of an atrial arrhythmia from previous AF ablation or de novo AF ablation). Nineteen SB maps were also created and compared. Ablation was performed until pulmonary vein isolation was achieved. RESULTS: Median time of mapping with HDW was 22.3 [IQR: 8.2] min. The number of points collected with HDW (13299.6±1362.8 vs 6952.8±841.9, p<0.001) and used (2337.3±158.0 vs 1727.5±163.8, p<0.001) was significantly higher compared to SB. Moreover, HDW was able to identify more sleeves (16 for right and 8 for left veins), where these were confirmed electrically silent by SB, with significantly increased PVR sleeve size as identified by HDW (p<0.001 for both right and left veins). Importantly, with the use of HDW, the ablation strategy changed in 23 patients (64% of targeted veins) with a significantly increased number of lesions required as compared to SB for right (p=0.005) and left veins (p=0.003). CONCLUSION: HDW technology is superior to SB in detecting pulmonary vein reconnections. This could potentially result into a significant change in ablation strategy and possibly to increased success rate following pulmonary vein isolation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Catéteres , Técnicas Eletrofisiológicas Cardíacas , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
6.
J Cardiovasc Electrophysiol ; 33(3): 510-526, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34921464

RESUMO

INTRODUCTION: Ethanol ablation (EA) is an alternative option for subjects with ventricular arrhythmias (VAs) refractory to conventional medical and ablative treatment. However, data on the efficacy and safety of EA remain sparse. METHODS: A systematic literature search was conducted. The primary outcomes were 1) freedom from the targeted VA and 2) freedom from any VAs post-EA. Additional safety outcomes were also analyzed. RESULTS: Ten studies were selected accounting for a population of 174 patients (62.3 ± 12.5 years, 94% male) undergoing 185 procedures. The overall acute success rate of EA was 72.4% (confidence interval [CI95% ]: 65.6-78.4). After a mean follow-up of 11.3 ± 5.5 months, the incidence of relapse of the targeted VA was 24.4% (CI95% : 17.1-32.8), while any VAs post-EA occurred in 41.3% (CI95% : 33.7-49.1). The overall incidence of procedural complications was 14.1% (CI95% : 9.8-19.8), with pericardial complications and complete atrioventricular block being the most frequent. An anterograde transarterial approach was associated with a higher rate of VA recurrences and complications compared to a retrograde transvenous route; however, differences in the baseline population characteristics and in the targeted ventricular areas should be accounted. CONCLUSION: EA is a valuable therapeutic option for VAs refractory to conventional treatment and can result in 1-year freedom from VA recurrence in 60%-75% of the patients. However, anatomical or technical challenges preclude acute success in almost 30% of the candidates and the rate of complication is not insignificant, highlighting the importance of well-informed patient selection. The certainty of the evidence is low, and further research is necessary.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/cirurgia , Ablação por Cateter/efeitos adversos , Etanol/efeitos adversos , Feminino , Ventrículos do Coração , Humanos , Masculino , Estudos Retrospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
7.
Pacing Clin Electrophysiol ; 44(6): 1039-1046, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33782987

RESUMO

BACKGROUND: Anatomical studies demonstrate significant variation in cavotricuspid isthmus (CTI) architecture. METHODS: Thirty-eight patients underwent CTI ablation at two tertiary centers. Operators delivered 682 lesions with a target ablation index (AI) of 600 Wgs. Ablation parameters were recorded every 10-20 ms. Post hoc, Visitags were trisected according to CTI position: inferior vena cava (IVC), middle (Mid), or ventricular (V) lesions. RESULTS: There were no complications. 92.1% of patients (n = 35) remained in sinus rhythm after 14.6 ± 3.4 months. For the whole CTI, peak AI correlated with mean impedance drop (ID) (R2  = 0.89, p < .0001). However, analysis by anatomical site demonstrated a non-linear relationship Mid CTI (R2  = 0.15, p = .21). Accordingly, while mean AI was highest Mid CTI (IVC: 473.1 ± 122.1 Wgs, Mid: 539.6 ± 103.5 Wgs, V: 486.2 ± 111.8 Wgs, ANOVA p < .0001), mean ID was lower (IVC: 10.7 ± 7.5Ω, Mid: 9.0 ± 6.5Ω, V: 10.9 ± 7.3Ω, p = .011), and rate of ID was slower (IVC: 0.37 ± 0.05 Ω/s, Mid: 0.18 ± 0.08 Ω/s, V: 0.29 ± 0.06 Ω/s, p < .0001). Mean contact force was similar at all sites; however, temporal fluctuations in contact force (IVC: 19.3 ± 12.0 mg/s, Mid: 188.8 ± 92.1 mg/s, V: 102.8 ± 32.3 mg/s, p < .0001) and catheter angle (IVC: 0.42°/s, Mid: 3.4°/s, V: 0.28°/s, p < .0001) were greatest Mid CTI. Use of a long sheath attenuated these fluctuations and improved energy delivery. CONCLUSIONS: Ablation characteristics vary across the CTI. At the Mid CTI, higher AI values do not necessarily deliver more effective ablation; this may reflect localized fluctuations in catheter angle and contact force.


Assuntos
Flutter Atrial/cirurgia , Ablação por Cateter/métodos , Valva Tricúspide/cirurgia , Idoso , Feminino , Humanos , Masculino
8.
JACC Clin Electrophysiol ; 6(14): 1783-1793, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33357574

RESUMO

OBJECTIVES: The goal of this study was to evaluate the role of dynamic substrate changes in facilitating conduction delay and re-entry in ventricular tachycardia (VT) circuits. BACKGROUND: The presence of dynamic substrate changes facilitate functional block and re-entry in VT but are rarely studied as part of clinical VT mapping. METHODS: Thirty patients (age 67 ± 9 years; 27 male subjects) underwent ablation. Mapping was performed with the Advisor HD Grid multipolar catheter. A bipolar voltage map was obtained during sinus rhythm (SR) and right ventricular sense protocol (SP) single extra pacing. SR and SP maps of late potentials (LP) and local abnormal ventricular activity (LAVA) were made and compared with critical sites for ablation, defined as sites of best entrainment or pace mapping. Ablation was then performed to critical sites, and LP/LAVA identified by the SP. RESULTS: At a median follow-up of 12 months, 90% of patients were free from antitachycardia pacing (ATP) or implantable cardioverter-defibrillator shocks. SP pacing resulted in a larger area of LP identified for ablation (19.3 mm2 vs. 6.4 mm2) during SR mapping (p = 0.001), with a sensitivity of 87% and a specificity of 96%, compared with 78% and 65%, respectively, in SR. CONCLUSIONS: LP and LAVA observed during the SP were able to identify regions critical for ablation in VT with a greater accuracy than SR mapping. This may improve substrate characterization in VT ablation. The combination of ablation to critical sites and SP-derived LP/LAVA requires further assessment in a randomized comparator study.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Idoso , Ventrículos do Coração/cirurgia , Humanos , Masculino , Taquicardia Ventricular/cirurgia
9.
J Mol Med (Berl) ; 98(8): 1149-1160, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32632751

RESUMO

KATP channels in the vasculature composed of Kir6.1 regulate vascular tone and may contribute to the pathogenesis of endotoxemia. We used mice with cell-specific deletion of Kir6.1 in smooth muscle (smKO) and endothelium (eKO) to investigate this question. We found that smKO mice had a significant survival disadvantage compared with their littermate controls when treated with a sub-lethal dose of lipopolysaccharide (LPS). All cohorts of mice became hypotensive following bacterial LPS administration; however, mean arterial pressure in WT mice recovered to normal levels, whereas smKO struggled to overcome LPS-induced hypotension. In vivo and ex vivo investigations revealed pronounced cardiac dysfunction in LPS-treated smKO, but not in eKO mice. Similar results were observed in a cecal slurry injection model. Metabolomic profiling of hearts revealed significantly reduced levels of metabolites involved in redox/energetics, TCA cycle, lipid/fatty acid and amino acid metabolism. Vascular smooth muscle-localised KATP channels have a critical role in the response to systemic infection by normalising cardiac function and haemodynamics through metabolic homeostasis. KEY MESSAGES: • Mice lacking vascular KATP channels are more susceptible to death from infection. • Absence of smooth muscle KATP channels depresses cardiac function during infection. • Cardiac dysfunction is accompanied by profound changes in cellular metabolites. • Findings from this study suggest a protective role for vascular KATP channels in response to systemic infection.


Assuntos
Endotoxemia/etiologia , Endotoxemia/metabolismo , Metabolismo Energético , Canais KATP/metabolismo , Miocárdio/metabolismo , Animais , Modelos Animais de Doenças , Suscetibilidade a Doenças , Endotoxemia/complicações , Cardiopatias/etiologia , Cardiopatias/metabolismo , Cardiopatias/fisiopatologia , Testes de Função Cardíaca , Canais KATP/genética , Lipopolissacarídeos/efeitos adversos , Camundongos , Camundongos Knockout , Modelos Biológicos , Músculo Liso Vascular/metabolismo , Miócitos Cardíacos/metabolismo
10.
J Cardiovasc Electrophysiol ; 31(8): 2192-2205, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32495462

RESUMO

AIMS: We sought out to make comparisons between all atrial fibrillation (AF) catheter ablation technologies using randomized controlled trial data. Our comparisons were freedom from AF, procedural duration, and fluoroscopy duration. METHODS: Searches were made of EMBASE, MEDLINE, and CENTRAL databases, and studies were selected which had cryoballoon, conventional radiofrequency (RF), multipolar RF catheters, and laser technology as an arm in the study and were identified as randomized controlled trials (RCTs). These studies were analyzed for direct comparisons using conventional meta-analysis and a combination of indirect and direct comparisons via a network meta-analysis (NMA). RESULTS: With respect to freedom from AF both direct comparisons and NMA did not demonstrate any significant difference. However in analysis of procedural and fluoroscopy duration (minutes) for the pulmonary vein ablation catheter (PVAC), both conventional analysis and NMA revealed significantly shorter procedure times, RF vs PVAC (conventional: 61.99 [38.03-85.94], P <.00001; NMA: 54.76 [36.64-72.88], P < .0001) and fluoroscopy times, RF vs PVAC (conventional: 12.96 [6.40-19.53], P = .0001; NMA: 8.89 [3.27-14.51], P < .01). The procedural duration was also shorter for the cryoballoon with NMA, RF vs CRYO (20.56 [3.47-37.65], P = .02). DISCUSSION: Our analysis demonstrated that while there was no difference in the efficacy of the individual catheter technologies, there are significant differences in the procedural duration for the PVAC and the cryoballoon. While they may seem an attractive solution for high-volume centers, further RCTs of next-generation technologies should be examined.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Humanos , Metanálise em Rede , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Ensaios Clínicos Controlados Aleatórios como Assunto , Tecnologia , Resultado do Tratamento
11.
Front Physiol ; 11: 236, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32256390

RESUMO

Sudden cardiac death caused by ventricular arrhythmias is among the leading causes of mortality, with approximately half of all deaths attributed to heart disease worldwide. Periodic repolarization dynamics (PRD) is a novel marker of repolarization instability and strong predictor of death in patients post-myocardial infarction that is believed to occur in association with low-frequency oscillations in sympathetic nerve activity. However, this hypothesis is based on associations of PRD with indices of sympathetic activity that are not directly linked to cardiac function, such as muscle vasoconstrictor activity and the variability of cardiovascular autospectra. In this review article, we critically evaluate existing scientific evidence obtained primarily in experimental animal models, with the aim of identifying the neuronal networks responsible for the generation of low-frequency sympathetic rhythms along the neurocardiac axis. We discuss the functional significance of rhythmic sympathetic activity on neurotransmission efficacy and explore its role in the pathogenesis of ventricular repolarization instability. Most importantly, we discuss important gaps in our knowledge that require further investigation in order to confirm the hypothesis that low frequency cardiac sympathetic oscillations play a causative role in the generation of PRD.

13.
J Cereb Blood Flow Metab ; 39(10): 2089-2095, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-29862863

RESUMO

KIR6.1 (KCNJ8) is a subunit of ATP sensitive potassium channel (KATP) that plays an important role in the control of peripheral vascular tone and is highly expressed in brain contractile cells (vascular smooth muscle cells and pericytes). This study determined the effect of global deletion of the KIR6.1 subunit on cerebral blood flow, neurovascular coupling and cerebral oxygenation in mice. In KIR6.1 deficient mice resting cerebral blood flow and brain parenchymal partial pressure of oxygen (PO2) were found to be markedly lower compared to that in their wildtype littermates. However, cortical blood oxygen level dependent responses triggered by visual stimuli were not affected in conditions of KIR6.1 deficiency. These data suggest that KATP channels containing KIR6.1 subunit are critically important for the maintenance of normal cerebral perfusion and parenchymal PO2 but play no significant role in the mechanisms underlying functional changes in brain blood flow.


Assuntos
Encéfalo/metabolismo , Circulação Cerebrovascular , Canais KATP/metabolismo , Oxigênio/metabolismo , Trifosfato de Adenosina/metabolismo , Animais , Encéfalo/irrigação sanguínea , Masculino , Camundongos , Oxigênio/sangue
15.
Circ Arrhythm Electrophysiol ; 11(10): e006740, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30354404

RESUMO

BACKGROUND: Glucagon-like peptide-1 receptor (GLP-1R) agonists improve cardiovascular outcomes in patients with type 2 diabetes mellitus. However, systemic actions of these agents cause sympathetic activation, which is generally considered to be detrimental in cardiovascular disease. Despite significant research interest in cardiovascular biology of GLP-1, the presence of GLP-1R in ventricular cardiomyocytes remains a controversial issue, and the effects of this peptide on the electrical properties of intact ventricular myocardium are unknown. We sought to determine the effects of GLP-1R agonist exendin-4 (Ex4) on ventricular action potential duration (APD) and susceptibility to ventricular arrhythmia in the rat heart in vivo and ex vivo. METHODS: Ventricular monophasic action potentials were recorded in anaesthetized (urethane) rats in vivo and isolated perfused rat hearts during sinus rhythm and ventricular pacing. RESULTS: In vivo, systemic administration of Ex4 (5 µg/kg intravenously) increased heart rate, and this effect was abolished by ß-adrenoceptor blockade. Despite causing sympathetic activation, Ex4 increased APD at 90% repolarization during ventricular pacing by 7% ( P=0.044; n=6) and reversed the effect of ß-adrenoceptor agonist dobutamine on APD at 90% repolarization. In isolated perfused hearts, Ex4 (3 nmol/L) increased APD at 90% repolarization by 14% ( P=0.015; n=6) with no effect on heart rate. Ex4 also reduced ventricular arrhythmia inducibility in conditions of ß-adrenoceptor stimulation with isoproterenol. Ex4 effects on APD and ventricular arrhythmia susceptibility were prevented in conditions of muscarinic receptor blockade or inhibition of nitric oxide synthase. CONCLUSIONS: These data demonstrate that GLP-1R activation effectively opposes the effects of ß-adrenoceptor stimulation on cardiac ventricular excitability and reduces ventricular arrhythmic potential. The effect of GLP-1R activation on the ventricular myocardium is indirect, mediated by acetylcholine and nitric oxide and, therefore, can be explained by stimulation of cardiac parasympathetic (vagal) neurons.


Assuntos
Antiarrítmicos/farmacologia , Arritmias Cardíacas/prevenção & controle , Exenatida/farmacologia , Receptor do Peptídeo Semelhante ao Glucagon 1/agonistas , Ventrículos do Coração/efeitos dos fármacos , Incretinas/farmacologia , Contração Miocárdica/efeitos dos fármacos , Função Ventricular/efeitos dos fármacos , Acetilcolina/metabolismo , Potenciais de Ação/efeitos dos fármacos , Agonistas Adrenérgicos beta/farmacologia , Animais , Arritmias Cardíacas/metabolismo , Arritmias Cardíacas/fisiopatologia , Estimulação Cardíaca Artificial , Receptor do Peptídeo Semelhante ao Glucagon 1/metabolismo , Frequência Cardíaca/efeitos dos fármacos , Ventrículos do Coração/metabolismo , Ventrículos do Coração/fisiopatologia , Preparação de Coração Isolado , Masculino , Óxido Nítrico/metabolismo , Ratos Sprague-Dawley , Transdução de Sinais/efeitos dos fármacos , Fatores de Tempo
16.
J Cardiovasc Dev Dis ; 5(4)2018 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-30249045

RESUMO

Haploinsufficiency of the T-box transcription factor TBX1 is responsible for many features of 22q11.2 deletion syndrome. Tbx1 is expressed dynamically in the pharyngeal apparatus during mouse development and Tbx1 homozygous mutants display numerous severe defects including abnormal cranial ganglion formation and neural crest cell defects. These abnormalities prompted us to investigate whether parasympathetic (vagal) innervation of the heart was affected in Tbx1 mutant embryos. In this report, we used an allelic series of Tbx1 mouse mutants, embryo tissue explants and cardiac electrophysiology to characterise, in detail, the function of Tbx1 in vagal innervation of the heart. We found that total nerve branch length was significantly reduced in Tbx1+/- and Tbx1neo2/- mutant hearts expressing 50% and 15% levels of Tbx1. We also found that neural crest cells migrated normally to the heart of Tbx1+/-, but not in Tbx1neo2 mutant embryos. In addition, we showed that cranial ganglia IXth and Xth were fused in Tbx1neo2/- but neuronal differentiation appeared intact. Finally, we used telemetry to monitor heart response to carbachol, a cholinergic receptor agonist, and found that heart rate recovered more quickly in Tbx1+/- animals versus controls. We speculate that this condition of decreased parasympathetic drive could result in a pro-arrhythmic substrate in some 22q11.2DS patients.

17.
Lab Chip ; 18(12): 1736-1749, 2018 06 12.
Artigo em Inglês | MEDLINE | ID: mdl-29762619

RESUMO

Circulating tumor cells (CTCs) are malignant cells released into the bloodstream with the potential to form metastases in secondary sites. These cells, acquired non-invasively, represent a sample of highly relevant tumor tissue that is an alternative to difficult and low-yield tumor biopsies. In recent years, there has been growing interest in genomic profiling of CTCs to enable longitudinal monitoring of the tumor's adaptive response to therapy. However, due to their extreme rarity, genotyping CTCs has proved challenging. Relevant mutations can be masked by leukocyte contamination in isolates. Heterogeneity between subpopulations of tumor cells poses an additional obstacle. Recent advances in single-cell sequencing can overcome these limitations but isolation of single CTCs is prone to cell loss and is prohibitively difficult and time consuming. To address these limitations, we developed a single cell sample preparation and genome sequencing pipeline that combines biophysical enrichment and single cell isolation using laser capture microdissection (LCM). A key component of this process is the encapsulation of enriched CTC sample in a hydrogel matrix, which enhances the efficiency of single-cell isolation by LCM, and is compatible with downstream sequencing. We validated this process by sequencing of single CTCs and cell free DNA (cfDNA) from a single patient with castration resistant prostate cancer. Identical mutations were observed in prostate cancer driver genes (TP53, PTEN, FOXA1) in both single CTCs and cfDNA. However, two independently isolated CTCs also had identical missense mutations in the genes for ATR serine/threonine kinase, KMT2C histone methyltransferase, and FANCC DNA damage repair gene. These mutations may be missed by bulk sequencing libraries, whereas single cell sequencing could potentially enable the characterization of key CTC subpopulations that arise during metastasis.


Assuntos
Separação Celular/métodos , Microdissecção e Captura a Laser/métodos , Células Neoplásicas Circulantes , Análise de Sequência de DNA/métodos , Análise de Célula Única/métodos , Cápsulas , Linhagem Celular Tumoral , Genômica , Humanos , Hidrogéis , Dispositivos Lab-On-A-Chip , Masculino , Mutação , Neoplasias da Próstata/genética
18.
Int J Cardiol ; 260: 82-87, 2018 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-29622458

RESUMO

BACKGROUND: Almost 1/3 of heart failure patients fail to respond to cardiac resynchronization therapy (CRT). A simple clinical score to predict who these patients are at the moment of referral or at time of implant may be of importance for early optimization of their management. METHODS: Observational study. A risk score was derived from factors associated to CRT response. The derivation cohort was composed of 1301 patients implanted with a CRT defibrillator in a multi-center French cohort-study. External validation of this score and assessment of its association with CRT response and all-cause mortality and/or heart transplant was performed in 1959 CRT patients implanted in 4 high-volume European centers. RESULTS: Independent predictors of CRT response in the derivation cohort were: female gender (OR = 2.08, 95% CI 1.26-3.45), NYHA class ≤ III (OR = 2.71, 95% CI 1.63-4.52), left ventricular ejection fraction ≥ 25% (OR = 1.75, 95% CI 1.27-2.41), QRS duration ≥ 150 ms (OR = 1.70, 95% CI 1.25-2.30) and estimated glomerular filtration rate ≥ 60 mL/min (OR = 2.01, 95% CI 1.48-2.72). Each was assigned 1 point. External validation showed good calibration (Hosmer-Lemeshow test-P = 0.95), accuracy (Brier score = 0.19) and discrimination (c-statistic = 0.67), with CRT response increasing progressively from 37.5% in patients with a score of 0 to 91.9% among those with score of 5 (Gamma for trend = 0.44, P < 0.001). Similar results were observed regarding all-cause mortality or heart transplant. CONCLUSION: The ScREEN score (Sex category, Renal function, ECG/QRS width, Ejection fraction and NYHA class) is composed of widely validated, easy to obtain predictors of CRT response, and predicts CRT response and overall mortality. It should be helpful in facilitating early consideration of alternative therapies for predicted non-responders to CRT therapy.


Assuntos
Terapia de Ressincronização Cardíaca/tendências , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Idoso , Feminino , Seguimentos , Taxa de Filtração Glomerular/fisiologia , Insuficiência Cardíaca/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Fatores de Risco , Resultado do Tratamento
19.
Glia ; 66(6): 1185-1199, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29274121

RESUMO

Astrocytes support neuronal function by providing essential structural and nutritional support, neurotransmitter trafficking and recycling and may also contribute to brain information processing. In this article we review published results and report new data suggesting that astrocytes function as versatile metabolic sensors of central nervous system (CNS) milieu and play an important role in the maintenance of brain metabolic homeostasis. We discuss anatomical and functional features of astrocytes that allow them to detect and respond to changes in the brain parenchymal levels of metabolic substrates (oxygen and glucose), and metabolic waste products (carbon dioxide). We report data suggesting that astrocytes are also sensitive to circulating endocrine signals-hormones like ghrelin, glucagon-like peptide-1 and leptin, that have a major impact on the CNS mechanisms controlling food intake and energy balance. We discuss signaling mechanisms that mediate communication between astrocytes and neurons and consider how these mechanisms are recruited by astrocytes activated in response to various metabolic challenges. We review experimental data suggesting that astrocytes modulate the activities of the respiratory and autonomic neuronal networks that ensure adaptive changes in breathing and sympathetic drive in order to support the physiological and behavioral demands of the organism in ever-changing environmental conditions. Finally, we discuss evidence suggesting that altered astroglial function may contribute to the pathogenesis of disparate neurological, respiratory and cardiovascular disorders such as Rett syndrome and systemic arterial hypertension.


Assuntos
Astrócitos/metabolismo , Encéfalo/metabolismo , Animais , Humanos
20.
Integr Biol (Camb) ; 9(6): 519-528, 2017 06 19.
Artigo em Inglês | MEDLINE | ID: mdl-28524208

RESUMO

Hemolytic anemia is one of the hallmarks of malaria and leads to an increase in oxidized heme (hemin) within the plasma of infected individuals. While scavenger proteins sequester much of the circulating heme, it has been hypothesized that extracellular heme may play a central role in malaria pathogenesis. We have previously developed the multiplex fluidic plunger (MFP) device for the measurement of red blood cell (RBC) deformability. Here, we demonstrate that the measurement of changes in RBC deformability is a sensitive method for inferring heme-induced oxidative stress. We further show that extracellular hemin concentration correlates closely with changes in RBC deformability and we confirm that this biophysical change correlates with other indicators of cell stress. Finally, we show that reduced erythrocyte deformability corresponds with both erythrophagocytosis and RBC osmotic fragility. The MFP microfluidic device presents a simple and potentially inexpensive alternative to existing methods for measuring hemolytic cell stress that could ultimately be used to perform clinical assessment of disease progression in severe malaria.


Assuntos
Deformação Eritrocítica/fisiologia , Eritrócitos/parasitologia , Hemina/metabolismo , Plasmodium falciparum/patogenicidade , Adulto , Anemia Hemolítica/sangue , Anemia Hemolítica/etiologia , Anemia Hemolítica/parasitologia , Fenômenos Biofísicos , Desenho de Equipamento , Hemólise/fisiologia , Humanos , Técnicas In Vitro , Dispositivos Lab-On-A-Chip , Malária Falciparum/sangue , Malária Falciparum/complicações , Malária Falciparum/parasitologia , Técnicas Analíticas Microfluídicas , Fragilidade Osmótica/fisiologia , Estresse Oxidativo , Fagocitose/fisiologia , Fosfatidilserinas/sangue , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...