Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
1.
Nat Med ; 30(7): 2020-2029, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38977913

RESUMO

Pulsed field ablation (PFA) is an emerging technology for the treatment of atrial fibrillation (AF), for which pre-clinical and early-stage clinical data are suggestive of some degree of preferentiality to myocardial tissue ablation without damage to adjacent structures. Here in the MANIFEST-17K study we assessed the safety of PFA by studying the post-approval use of this treatment modality. Of the 116 centers performing post-approval PFA with a pentaspline catheter, data were received from 106 centers (91.4% participation) regarding 17,642 patients undergoing PFA (mean age 64, 34.7% female, 57.8% paroxysmal AF and 35.2% persistent AF). No esophageal complications, pulmonary vein stenosis or persistent phrenic palsy was reported (transient palsy was reported in 0.06% of patients; 11 of 17,642). Major complications, reported for ~1% of patients (173 of 17,642), were pericardial tamponade (0.36%; 63 of 17,642) and vascular events (0.30%; 53 of 17,642). Stroke was rare (0.12%; 22 of 17,642) and death was even rarer (0.03%; 5 of 17,642). Unexpected complications of PFA were coronary arterial spasm in 0.14% of patients (25 of 17,642) and hemolysis-related acute renal failure necessitating hemodialysis in 0.03% of patients (5 of 17,642). Taken together, these data indicate that PFA demonstrates a favorable safety profile by avoiding much of the collateral damage seen with conventional thermal ablation. PFA has the potential to be transformative for the management of patients with AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/terapia , Feminino , Masculino , Pessoa de Meia-Idade , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Idoso , Resultado do Tratamento , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia
2.
Artigo em Inglês | MEDLINE | ID: mdl-38869506

RESUMO

BACKGROUND: Atrial fibrillation (AF) and heart failure (HF) coexist, increasing morbidity and mortality. Studies have demonstrated improved outcomes following AF ablation in HF patients with reduced ejection fraction (EF). OBJECTIVE: To assess the outcomes of pulsed-field ablation (PFA) in HF. METHODS: MANIFEST-PF is a multicenter patient-level registry of consecutive patients undergoing PFA for paroxysmal (PAF) or persistent AF (PerAF). In this sub-study, patients were stratified as: no history of HF (no-HF), HF with preserved EF (HFPEF; LVEF≥50%) or HF with reduced/mildly-reduced EF (HFMR/REF; LVEF<50%). The primary effectiveness and safety endpoints were freedom from documented atrial arrhythmias lasting ≥30s and major adverse events (MAEs), respectively. RESULTS: Of the 1,381 patients, 85% (n=1,174) were no-HF, 6.2% (n=87) were HFPEF, and 8.6% (n=120) were HFMR/REF. No-HF patients had less PerAF than patients with HF (p<0.001), with no difference between HF subtypes (p=1.00). The 1-year freedom from atrial arrhythmia was significantly higher in no-HF than with HFPEF or HFMR/REF (79.9%, 71.3%, 67.5%, p<0.001), but similar between HFMR/REF and HFPEF (p=0.26). However, there was no significant difference in freedom from atrial arrhythmia among patients with no-HF vs HFPEF vs HFMR/REF for those with PAF (82.8%/82.4%/71.7%, p=0.09) and PerAF (73.3%, 64.2%, and 64.9%, p=0.14.MAE rates were similar between the no-HF, HFPEF and HFMR/REF groups (1.9%, 0%, and 2.5%, respectively). CONCLUSION: PFA appears to be potentially safe and effective in AF patients with HF. Freedom from atrial arrhythmia post-PFA was higher in patients without a history of HF, with no significant difference between HF subtypes.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38864809

RESUMO

BACKGROUND: Atrial fibrillation (AF) and heart failure (HF) coexist, increasing morbidity and mortality. Studies have demonstrated improved outcomes following AF ablation in HF patients with reduced ejection fraction (EF). OBJECTIVE: This study sought to assess the outcomes of pulsed field ablation (PFA) in HF. METHODS: MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation) is a multicenter, patient-level registry of consecutive patients undergoing PFA for paroxysmal AF or persistent AF (PerAF). In this substudy, patients were stratified as no history of HF (no-HF), HF with preserved EF (HFpEF) (left ventricular EF of ≥50%) or HF with reduced/mildly reduced EF (HFmr/rEF) (left ventricular EF of <50%). The primary effectiveness and safety endpoints were freedom from documented atrial arrhythmias lasting ≥30 seconds and major adverse events, respectively. RESULTS: Of the 1,381 patients, 85% (n = 1,174) were no-HF, 6.2% (n = 87) were HFpEF, and 8.6% (n = 120) were HFmr/rEF. No-HF patients had less PerAF than patients with HF (P < 0.001), with no difference between HF subtypes (P = >0.99). The 1-year freedom from atrial arrhythmia was significantly higher in no-HF patients than in those with HFpEF or HFmr/rEF (79.9%, 71.3%, and 67.5%, respectively; P < 0.001) but similar between patients with HFmr/rEF and HFpEF (P = 0.26). However, there was no significant difference in freedom from atrial arrhythmia among patients with no-HF vs HFpEF vs HFmr/rEF for those with paroxysmal AF (82.8%, 82.4%, and 71.7%, respectively; P = 0.09) and PerAF (73.3%, 64.2%, and 64.9%, respectively; P = 0.14). Major adverse event rates were similar between the no-HF, HFpEF, and HFmr/rEF groups (1.9%, 0%, and 2.5%, respectively). CONCLUSIONS: PFA appears to be potentially safe and effective in AF patients with HF. Freedom from atrial arrhythmia post-PFA was higher in patients without a history of HF, with no significant difference between HF subtypes.

4.
J Cardiovasc Electrophysiol ; 35(8): 1525-1535, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38803029

RESUMO

INTRODUCTION: The unique safety profile of pulsed field ablation (PFA) has made pulmonary vein isolation (PVI) + left atrial posterior wall (LAPW) ablation promising for treating persistent atrial fibrillation (PerAF). The goal of this study was to assess long-term freedom from atrial fibrillation, atrial flutter, and atrial tachycardia (AF/AFL/AT), as well as the safety and feasibility of LAPW PFA using multipolar, pentaspline Farawave catheter. METHODS: Retrospective observational study at a single institution. Data for 94 patients were collected from a prespecified intraprocedural registry. The long-term AF/AFL/AT recurrence assessment was based on an analysis of medical history; 24-h Holter ECGs at 3, 6, and 12 months postablation; and 12-lead ECGs recorded during symptomatic episodes or visits. RESULTS: Half of the patients had ls-PerAF, and half had a history of catheter ablation-mostly RF PVI. The acute ablation success rate was 100%, and the primary safety outcome was observed in 2 patients. Fifty patients experienced AF/AFL/AT recurrence (54.3%). An increase in LAPW low-voltage areas and AF classification were associated with arrhythmia recurrence. After a median follow-up of 13 months, the Kaplan‒Meier estimated median time free of AF/AFL/AT after a single procedure was 14.7 months. CONCLUSION: PFA PVI + PWA had the best outcome in perAF patients without extensive LA fibrosis. AF recurrence was paroxysmal in significant part of the cohort. The addition of PWA to PVI using multipolar PFA was safe and did not significantly influence the transpired ablation time.


Assuntos
Potenciais de Ação , Fibrilação Atrial , Ablação por Cateter , Frequência Cardíaca , Veias Pulmonares , Recidiva , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Ablação por Cateter/efeitos adversos , Fatores de Tempo , Fatores de Risco , Sistema de Registros , Estudos de Viabilidade , Resultado do Tratamento , Intervalo Livre de Progressão , Flutter Atrial/cirurgia , Flutter Atrial/fisiopatologia , Flutter Atrial/diagnóstico , Taquicardia Supraventricular/cirurgia , Taquicardia Supraventricular/fisiopatologia , Taquicardia Supraventricular/diagnóstico , Átrios do Coração/fisiopatologia , Átrios do Coração/cirurgia , Cateteres Cardíacos
5.
Circ Arrhythm Electrophysiol ; 17(5): e012667, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38655693

RESUMO

BACKGROUND: We previously presented the safety and early efficacy of the inspIRE study (Study for Treatment of Paroxysmal Atrial Fibrillation [PAF] by Pulsed-field Ablation [PFA] System With Irreversible Electroporation [IRE]). With the study's conclusion, we report the outcomes of the full pivotal study cohort, with an additional analysis of predictors of success. METHODS: InspIRE was a prospective, multicenter, single-arm clinical trial of drug-refractory paroxysmal atrial fibrillation. Pulmonary vein isolation was performed with a variable-loop circular catheter integrated with a 3-dimensional mapping system. Follow-up with 24-hour Holter was at 3, 6, and 12 months, as well as remote rhythm monitoring: weekly from 3 to 5 months, monthly from 6 to 12 months, and for symptoms. The primary effectiveness end point (PEE) was acute pulmonary vein isolation plus freedom from any atrial arrhythmia at 12 months. Additional subanalyses report predictors of PEE success. RESULTS: The patient cohort included 186 patients: aged 59±10 years, female 30%, and CHA2DS2-VASc 1.3±1.2. The previously reported primary adverse event rate was 0%. One serious procedure-related adverse event, urinary retention, was reported. The PEE was achieved in 75.6% (95% CI, 69.5%-81.8%). The clinical success of freedom from symptomatic recurrence was 81.7% (95% CI, 76.1%-87.2%). Simulating a monitoring method used in standard real-world practice (without protocol-driven remote rhythm monitoring), this translates to a freedom from all and symptomatic recurrence of 85.8% (95% CI, 80.8%-90.9%) or 94.0% (95% CI, 90.6%-97.5%), respectively. Multivariate analyses revealed that left ventricular ejection fraction ≥60% (adjusted odds ratio, 0.30) and patients receiving ≥48 PFA applications (adjusted odds ratio, 0.28) were independent predictors of PEE success. Moreover, PEE success was 79.2% in patients who received ≥12 PFA applications per vein compared with 57.1% in patients receiving fewer PFA applications. CONCLUSIONS: The inspIRE study confirms the safety and effectiveness of pulmonary vein isolation using the novel 3-dimensional mapping integrated circular loop catheter. An optimal number of PFA applications (≥48 total or ≥12 per vein) resulted in an improved 1-year success rate of ≈80%. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04524364.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Feminino , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Masculino , Pessoa de Meia-Idade , Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Ablação por Cateter/efeitos adversos , Estudos Prospectivos , Idoso , Fatores de Tempo , Frequência Cardíaca , Potenciais de Ação , Eletrocardiografia Ambulatorial/instrumentação , Recidiva , Cateteres Cardíacos , Valor Preditivo dos Testes , Resultado do Tratamento , Imageamento Tridimensional , Fatores de Risco , Desenho de Equipamento , Técnicas Eletrofisiológicas Cardíacas
6.
Heart Rhythm ; 21(8): 1211-1217, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38499129

RESUMO

BACKGROUND: Ablation of accessory pathways (APs) is the cornerstone for treatment of patients with Wolff-Parkinson-White syndrome and manifestation of atrioventricular reentrant tachycardia. Pulsed field ablation (PFA) is a new type of nonthermal energy source delivered to the underlying tissue via the ablation catheter and used for ablation of arrhythmic substrates. OBJECTIVE: The purpose of this study was to determine the efficiency and long-term outcome of ablation of APs of different localizations using a focal pulsed electrical field. METHODS: Electrophysiological study was performed in patients with indication for AP ablation. An ablation catheter was used to map the position of AP insertion. Pulsed electric field was delivered through a standard ablation catheter. In left-sided APs, the first ablation attempt was within the coronary sinus (CS). Patient follow-up was scheduled 1-3 months after the ablation. Additional check-up was performed after 6 and 12 months. RESULTS: Fourteen 14 patients (3 pediatric) were treated. Termination of AP conduction was achieved in all procedures. The cohort consisted of 3 right free wall, 3 posteroseptal, and 8 left-sided APs. Ablation through CS was successfully used in 7 of 8 patients with left-sided APs. No complications were reported. Median follow-up was 5.5 months. Conduction recurrence through AP was documented in 1 patient. CONCLUSION: Focal PFA for AP shows promising results in terms of efficacy and safety. A high rate of successful termination of left-sided APs by ablation within CS may represent a new standard approach. The safety and efficacy profile of PFA seems to be transferable to the pediatric population.


Assuntos
Feixe Acessório Atrioventricular , Ablação por Cateter , Síndrome de Wolff-Parkinson-White , Humanos , Masculino , Feminino , Ablação por Cateter/métodos , Feixe Acessório Atrioventricular/cirurgia , Feixe Acessório Atrioventricular/fisiopatologia , Adulto , Síndrome de Wolff-Parkinson-White/cirurgia , Síndrome de Wolff-Parkinson-White/fisiopatologia , Resultado do Tratamento , Adolescente , Pessoa de Meia-Idade , Criança , Seguimentos , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Adulto Jovem , Eletrocardiografia , Sistema de Condução Cardíaco/fisiopatologia , Técnicas Eletrofisiológicas Cardíacas/métodos
7.
JACC Clin Electrophysiol ; 10(5): 900-912, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38430087

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) alone is insufficient to treat many patients with persistent atrial fibrillation (PersAF). Adjunctive left atrial posterior wall (LAPW) ablation with thermal technologies has revealed lack of efficacy, perhaps limited by the difficulty in achieving lesion durability amid concerns of esophageal injury. OBJECTIVES: This study aims to compare the safety and effectiveness of PVI + LAPW ablation vs PVI in patients with PersAF using pulsed-field ablation (PFA). METHODS: In a retrospective analysis of the MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-approval Clinical Use of Pulsed Field Ablation) registry, we studied consecutive PersAF patients undergoing post-approval treatment with a pentaspline PFA catheter. The primary effectiveness outcome was freedom from any atrial arrhythmia of ≥30 seconds. Safety outcomes included the composite of acute and chronic major adverse events. RESULTS: Of the 547 patients with PersAF who underwent PFA, 131 (24%) received adjunctive LAPW ablation. Compared to PVI-alone, patients receiving adjunctive LAPW ablation were younger (65 vs 67 years of age, P = 0.08), had a lower CHA2DS2-VASc score (2.3 ± 1.6 vs 2.6 ± 1.6, P = 0.08), and were more likely to receive electroanatomical mapping (48.1% vs 39.0%, P = 0.07) and intracardiac echocardiography imaging (46.1% vs 17.1%, P < 0.001). The 1-year Kaplan-Meier estimate for freedom from atrial arrhythmias was not statistically different between groups in the full (PVI + LAPW: 66.4%; 95% CI: 57.6%-74.4% vs PVI: 73.1%; 95% CI: 68.5%-77.2%; P = 0.68) and propensity-matched cohorts (PVI + LAPW: 71.7% vs PVI: 68.5%; P = 0.34). There was also no significant difference in major adverse events between the groups (2.2% vs 1.4%, respectively, P = 0.51). CONCLUSIONS: In patients with PersAF undergoing PFA, as compared to PVI-alone, adjunctive LAPW ablation did not improve freedom from atrial arrhythmia at 12 months.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Átrios do Coração , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Masculino , Feminino , Idoso , Ablação por Cateter/métodos , Ablação por Cateter/efeitos adversos , Pessoa de Meia-Idade , Estudos Retrospectivos , Átrios do Coração/cirurgia , Veias Pulmonares/cirurgia , Resultado do Tratamento , Sistema de Registros
8.
J Cardiovasc Electrophysiol ; 35(4): 832-842, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38448797

RESUMO

INTRODUCTION: Cryoablation therapy for pulmonary vein isolation (PVI) to treat paroxysmal atrial fibrillation (PAF) is well established. A novel 28 mm cryoballoon system designed to operate under low pressure to safely reach a lower nadir temperature and maintain constant balloon size during cooling has not been prospectively studied in a large patient population for safety and efficacy. The FROZEN AF (NCT04133168) trial was an international multicenter, open-label, prospective, single-arm study on the safety and performance of a novel cryoballoon system for treatment of PAF. METHODS AND RESULTS: The study enrolled patients at 44 sites in 10 countries across North America, Europe, and Asia. Subjects were indicated for PVI treatment of PAF and had failed or were intolerant of one or more antiarrhythmic drugs. Procedural outcomes were defined based on the 2017 HRS consensus statement. Follow-up was performed at 7 days, 3, 6, and 12 months. Data are reported as mean ± SD or median (IQR). PVI was performed with a 28 mm cryoballoon in 325 drug refractory PAF patients. Complete PVI was achieved in 95.7% of patients. In cryoablation lesions longer than 60 s, 60.1% of PV isolations required only a single cryoballoon application. Procedure related complications included: phrenic nerve palsy [temporary 4 (1.2%), persistent 0 (0.0%)], cardiac tamponade/perforation 2 (0.6%), and air embolism 1 (0.3%). Freedom from documented atrial arrhythmia recurrence at 12 months was 79.9% (AF 82.7%, AFL 96.5%, AT 98.1%), antiarrhythmic drugs (AAD) were continued or re-initiated in 26.8% of patients after the 3-month blanking period. Additionally, an extension arm enrolled 50 pts for treatment with 28/31 mm variable size cryoballoon. A single temporary PNP occurred in this group, which resolved before discharge. Freedom from documented recurrence at 12 months in these pts was 82.0%. CONCLUSIONS: This novel cryoballoon may facilitate PVI to treat PAF, providing more options to address the variety of anatomies present in patients with PAF. This cryoballoon system proved to be safe and effective for treatment of patients with drug refractory or drug intolerant PAF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Traumatismos Cardíacos , Veias Pulmonares , Humanos , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/epidemiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Traumatismos Cardíacos/etiologia , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
9.
Europace ; 26(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38363995

RESUMO

Ventricular tachycardia (VT), and its occurrence, is still one of the main reasons for sudden cardiac death and, therefore, for increased mortality and morbidity foremost in patients with structural heart [Kahle A-K, Jungen C, Alken F-A, Scherschel K, Willems S, Pürerfellner H et al. Management of ventricular tachycardia in patients with ischaemic cardiomyopathy: contemporary armamentarium. Europace 2022;24:538-51]. Catheter ablation has become a safe and effective treatment option in patients with recurrent VT [Cronin EM, Bogun FM, Maury P, Peichl P, Chen M, Namboodiri N et al. 2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias. Heart Rhythm 2020;17:e2-154]. Previous and current guidelines provide guidance on indication for VT ablation and risk assessment and evaluation of underlying disease. However, no uniform recommendation is provided regarding procedural strategies, timing of ablation, and centre setting. Therefore, these specifics seem to differ largely, and recent data are sparse. This physician-based European Heart Rhythm Association survey aims to deliver insights on not only infrastructural settings but also procedural specifics, applied technologies, ablation strategies, and procedural endpoints. Therefore, these findings might deliver a real-world scenario of VT management and potentially are of guidance for other centres.


Assuntos
Ablação por Cateter , Isquemia Miocárdica , Taquicardia Ventricular , Humanos , Fluxo de Trabalho , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas/cirurgia , Resultado do Tratamento , Ablação por Cateter/métodos
10.
J Cardiovasc Electrophysiol ; 35(4): 765-774, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38357859

RESUMO

INTRODUCTION: Pulsed electric field (PEF) ablation relies on the intersection of a critical voltage gradient with tissue to cause cell death. Field-based lesion formation with PEF technologies may still depend on catheter-tissue contact (CTC). The purpose of this study was to assess the impact of CTC on PEF lesion formation with an investigational large area focal (LAF) catheter in a preclinical model. METHODS: PEF ablation via a 10-spline LAF catheter was used to create discrete right ventricle (RV) lesions and atrial lesion sets in 10 swine (eight acute, two chronic). Local impedance (LI) was used to assess CTC. Lesions were assigned to three cohorts using LI above baseline: no tissue contact (NTC: ≤∆10 Ω, close proximity to tissue), low tissue contact (LTC: ∆11-29 Ω), and high tissue contact (HTC: ≥∆30 Ω). Acute animals were infused with triphenyl tetrazolium chloride (TTC) and killed ≥2 h post-treatment. Chronic animals were remapped 30 days post-index procedure and stained with infused TTC. RESULTS: Mean (± SD) RV treatment sizes between LTC (n = 14) and HTC (n = 17) lesions were not significantly different (depth: 5.65 ± 1.96 vs. 5.68 ± 2.05 mm, p = .999; width: 15.68 ± 5.22 vs. 16.98 ± 4.45 mm, p = .737), while mean treatment size for NTC lesions (n = 6) was significantly smaller (1.67 ± 1.16 mm depth, 5.97 ± 4.48 mm width, p < .05). For atrial lesion sets, acute and chronic conduction block were achieved with both LTC (N = 7) and HTC (N = 6), and NTC resulted in gaps. CONCLUSIONS: PEF ablation with a specialized LAF catheter in a swine model is dependent on CTC. LI as an indicator of CTC may aid in the creation of consistent transmural lesions in PEF ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Suínos , Animais , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Átrios do Coração , Frequência Cardíaca , Ventrículos do Coração , Impedância Elétrica , Catéteres , Fibrilação Atrial/cirurgia
12.
Europace ; 26(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38227804

RESUMO

AIMS: Although guidelines for the management of atrial fibrillation (AF) are regularly published, many controversial issues remain, limiting their implementation. We aim to describe current clinical practice among European Heart Rhythm Association (EHRA) community according to last guidelines. METHODS AND RESULTS: A 30 multiple-choice questionnaire covering the most controversial topics related to AF management was distributed through the EHRA Research Network, National Societies, and social media between January and February 2023. One hundred and eighty-one physicians responded the survey, 61% from university hospitals. Atrial fibrillation screening in high-risk patients is regularly performed by 57%. Only 42% has access to at least one programme aiming at diagnosing/managing comorbidities and lifestyle modifications, with marked heterogeneity between countries. Direct oral anticoagulants are the preferred antithrombotic (97%). Rhythm control is the preferred strategy in most AF phenotypes: symptomatic vs. asymptomatic paroxysmal AF (97% vs. 77%), low vs. high risk for recurrence persistent AF (90% vs. 72%), and permanent AF (20%). I-C drugs and amiodarone are preferred while dronedarone and sotalol barely used. Ablation is the first-line therapy for symptomatic paroxysmal AF (69%) and persistent AF with markers of atrial disease (57%) and is performed independently of symptoms by 15%. In persistent AF, 68% performs only pulmonary vein isolation and 32% also additional lesions. CONCLUSION: There is marked heterogeneity in AF management and limited accordance to last guidelines in the EHRA community. Most of the discrepancies are related to the main controversial issues, such as those related to AF screening, management of comorbidities, pharmacological treatment, and ablation strategy.


Assuntos
Fibrilação Atrial , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Comorbidade , Inquéritos e Questionários , Sotalol , Anticoagulantes/uso terapêutico , Resultado do Tratamento
13.
J Cardiovasc Electrophysiol ; 35(4): 856-861, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38297424

RESUMO

INTRODUCTION: With the entry of pulsed-field ablation (PFA) into electrophysiology, new possibilities for ablation of different substrates such as epicardial foci of premature ventricular contractions (PVCs) from coronary venous system (CVS) have been opened. METHODS: This article focuses on a case of a 27-year-old patient with frequent monomorphic PVCs of epicardial origin, treated by radiofrequency ablation, followed by PFA. RESULTS: After unsuccessful focus ablation through CVS with RFA, successful ablations from the same region with PFA were achieved. CONCLUSION: This is the first described case of successful ablation of epicardial PVCs using PFA, which we hope will help in defining indications for this novel technology and enhance quality of treatment for patients with different arrhythmias.


Assuntos
Ablação por Cateter , Seio Coronário , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Humanos , Adulto , Seio Coronário/diagnóstico por imagem , Seio Coronário/cirurgia , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ventrículos do Coração , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia , Complexos Ventriculares Prematuros/etiologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/etiologia
14.
JAMA Cardiol ; 8(12): 1142-1151, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37910101

RESUMO

Importance: Previous studies evaluating the association of patient sex with clinical outcomes using conventional thermal ablative modalities for atrial fibrillation (AF) such as radiofrequency or cryoablation are controversial due to mixed results. Pulsed field ablation (PFA) is a novel AF ablation energy modality that has demonstrated preferential myocardial tissue ablation with a unique safety profile. Objective: To compare sex differences in patients undergoing PFA for AF in the Multinational Survey on the Methods, Efficacy, and Safety on the Postapproval Clinical Use of Pulsed Field Ablation (MANIFEST-PF) registry. Design, Setting, and Participants: This was a retrospective cohort study of MANIFEST-PF registry data, which included consecutive patients undergoing postregulatory approval treatment with PFA to treat AF between March 2021 and May 2022 with a median follow-up of 1 year. MANIFEST-PF is a multinational, retrospectively analyzed, prospectively enrolled patient-level registry including 24 European centers. The study included all consecutive registry patients (age ≥18 years) who underwent first-ever PFA for paroxysmal or persistent AF. Exposure: PFA was performed on patients with AF. All patients underwent pulmonary vein isolation and additional ablation, which was performed at the discretion of the operator. Main Outcomes and Measures: The primary effectiveness outcome was freedom from clinically documented atrial arrhythmia for 30 seconds or longer after a 3-month blanking period. The primary safety outcome was the composite of acute (<7 days postprocedure) and chronic (>7 days) major adverse events (MAEs). Results: Of 1568 patients (mean [SD] age, 64.5 [11.5] years; 1015 male [64.7%]) with AF who underwent PFA, female patients, as compared with male patients, were older (mean [SD] age, 68 [10] years vs 62 [12] years; P < .001), had more paroxysmal AF (70.2% [388 of 553] vs 62.4% [633 of 1015]; P = .002) but had fewer comorbidities such as coronary disease (9% [38 of 553] vs 15.9% [129 of 1015]; P < .001), heart failure (10.5% [58 of 553] vs 16.6% [168 of 1015]; P = .001), and sleep apnea (4.7% [18 of 553] vs 11.7% [84 of 1015]; P < .001). Pulmonary vein isolation was performed in 99.8% of female (552 of 553) and 98.9% of male (1004 of 1015; P = .90) patients. Additional ablation was performed in 22.4% of female (124 of 553) and 23.1% of male (235 of 1015; P = .79) patients. The 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was similar in male and female patients (79.0%; 95% CI, 76.3%-81.5% vs 76.3%; 95% CI, 72.5%-79.8%; P = .28). There was also no significant difference in acute major AEs between groups (male, 1.5% [16 of 1015] vs female, 2.5% [14 of 553]; P = .19). Conclusion and Relevance: Results of this cohort study suggest that after PFA for AF, there were no significant sex differences in clinical effectiveness or safety events.


Assuntos
Fibrilação Atrial , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Adolescente , Fibrilação Atrial/tratamento farmacológico , Estudos Retrospectivos , Estudos de Coortes , Fatores Sexuais , Resultado do Tratamento
16.
Europace ; 25(7)2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37440757

RESUMO

AIMS: Patients with atrial fibrillation who despite taking oral anti-coagulant therapy (OAT) suffer a stroke or systemic embolism (SSE) without vascular cause or who develop left atrial appendage (LAA) thrombus (LAAT) should be considered as having malignant LAA. The optimal treatment strategy to reduce SSE risk in such patients is unknown. The aim of the study is to investigate the diagnostic and therapeutic pathways for malignant LAA practiced in European cardiac centres. METHODS AND RESULTS: An 18-item online questionnaire on malignant LAA was disseminated by the European Heart Rhythm Association (EHRA) Scientific Initiatives Committee. A total of 196 physicians participated in the survey. There seems to be high confidence in transoesophageal echocardiography (TEE) imaging, considering LAAT diagnosis. Switching to another direct oral anti-coagulant (DOAC) is the preferred initial step for the treatment of malignant LAA followed by a switch to vitamin K antagonist (VKA), low-molecular-weight heparin, or continued/optimized DOAC dosage, whereas LAA closure is the last option. Left atrial appendage closure is a viable option in patients with embolic stroke despite OAT and no evidence of thrombus at TEE (empty LAA) after comprehensive diagnostic measures to exclude other sources of embolism. CONCLUSION: This EHRA survey provides a snapshot of the contemporary management of patients diagnosed with malignant LAA. Currently, the majority of patients are treated on an outpatient basis with either shifting from VKA to DOAC or from one DOAC to another. Left atrial appendage closure in this population seems to be reserved for patients with higher bleeding risk or complications of malignant LAA, such as stroke.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Embolia , Cardiopatias , Acidente Vascular Cerebral , Trombose , Humanos , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/complicações , Anticoagulantes/uso terapêutico , Ecocardiografia Transesofagiana , Trombose/epidemiologia , Fibrinolíticos/uso terapêutico , Inquéritos e Questionários , Resultado do Tratamento
17.
Europace ; 25(6)2023 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-37335976

RESUMO

AIMS: Pulsed field ablation (PFA) has emerged as a promising alternative to thermal ablation for treatment of atrial fibrillation (AF). We report performance and safety using the CENTAURI™ System (Galvanize Therapeutics) with three commercial, focal ablation catheters. METHODS AND RESULTS: ECLIPSE AF (NCT04523545) was a prospective, single-arm, multi-centre study evaluating safety and acute and chronic pulmonary vein isolation (PVI) durability using the CENTAURI System in conjunction with the TactiCath SE, StablePoint, and ThermoCool ST ablation catheters. Patients with paroxysmal or persistent AF were treated at two centres. Patients were analysed in five cohorts based upon ablation settings, catheter, and mapping system. Pulsed field ablation was performed in 82 patients (74% male, 42 paroxysmal AF). Pulmonary vein isolation was achieved in 100% of pulmonary veins (322/322) with first-pass isolation in 92.2% (297/322). There were four serious adverse events of interest (three vascular access complications and one lacunar stroke). Eighty patients (98%) underwent invasive remapping. Pulsed field ablation development Cohorts 1 and 2 showed a per-patient isolation rate of 38% and 26% and a per-PV isolation rate of 47% and 53%, respectively. Optimized PFA Cohorts 3-5 showed a per-patient isolation rate of 60%, 73%, and 81% and a per-PV isolation rate of 84%, 90%, and 92%, respectively. CONCLUSION: ECLIPSE AF demonstrated that optimized PFA using the CENTAURI System with three commercial, contact force-sensing, solid-tip focal ablation catheters resulted in transmural lesion formation and high proportion of durable PVI with a favourable safety profile, thus providing a viable treatment option for AF that integrates with contemporary focal ablation workflows.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Estudos Prospectivos , Adesões Focais , Resultado do Tratamento , Catéteres , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Recidiva
18.
Circulation ; 148(1): 35-46, 2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37199171

RESUMO

BACKGROUND: Pulsed field ablation is a novel nonthermal cardiac ablation modality using ultra-rapid electrical pulses to cause cell death by a mechanism of irreversible electroporation. Unlike the traditional ablation energy sources, pulsed field ablation has demonstrated significant preferentiality to myocardial tissue ablation, and thus avoids certain thermally mediated complications. However, its safety and effectiveness remain unknown in usual clinical care. METHODS: MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation) is a retrospective, multinational, patient-level registry wherein patients at each center were prospectively included in their respective center registries. The registry included all patients undergoing postapproval treatment with a multielectrode 5-spline pulsed field ablation catheter to treat atrial fibrillation (AF) between March 1, 2021, and May 30, 2022. The primary effectiveness outcome was freedom from clinical documented atrial arrhythmia (AF/atrial flutter/atrial tachycardia) of ≥30 seconds on the basis of electrocardiographic data after a 3-month blanking period (on or off antiarrhythmic drugs). Safety outcomes included the composite of acute (<7 days postprocedure) and latent (>7 days) major adverse events. RESULTS: At 24 European centers (77 operators) pulsed field ablation was performed in 1568 patients with AF: age 64.5±11.5 years, female 35%, paroxysmal/persistent AF 65%/32%, CHA2DS2-VASc 2.2±1.6, median left ventricular ejection fraction 60%, and left atrial diameter 42 mm. Pulmonary vein isolation was achieved in 99.2% of patients. After a median (interquartile range) follow-up of 367 (289-421) days, the 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was 78.1% (95% CI, 76.0%-80.0%); clinical effectiveness was more common in patients with paroxysmal AF versus persistent AF (81.6% versus 71.5%; P=0.001). Acute major adverse events occurred in 1.9% of patients. CONCLUSIONS: In this large observational registry of the postapproval clinical use of pulsed field technology to treat AF, catheter ablation using pulsed field energy was clinically effective in 78% of patients with AF.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda , Resultado do Tratamento , Flutter Atrial/etiologia , Sistema de Registros , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
19.
J Cardiovasc Dev Dis ; 10(2)2023 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-36826581

RESUMO

The autonomic nervous system is crucial in initiating and maintaining atrial fibrillation (AF). Catestatin is a multipurpose peptide that regulates cardiovascular systems and reduces harmful, excessive activity of the sympathetic nervous system by blocking the release of catecholamines. We aimed to determine whether serum catestatin concentrations are associated with AF severity, duration indices, and various clinical and laboratory indicators in these individuals to better define the clinical value of catestatin in patients with AF. The present single center study enrolled 73 participants with AF and 72 healthy age-matched controls. Serum catestatin concentrations were markedly higher in AF patients than controls (14.11 (10.21-26.02) ng/mL vs. 10.93 (5.70-20.01) ng/mL, p = 0.013). Furthermore, patients with a more severe form of AF had significantly higher serum catestatin (17.56 (12.80-40.35) vs. 10.98 (8.38-20.91) ng/mL, p = 0.001). Patients with higher CHA2DS2-VASc scores (17.58 (11.89-37.87) vs. 13.02 (8.47-22.75) ng/mL, p = 0.034) and higher NT-proBNP levels (17.58 (IQR 13.91-34.62) vs. 13.23 (IQR 9.04-22.61), p = 0.036) had significantly higher serum catestatin concentrations. Finally, AF duration correlated negatively with serum catestatin levels (r = -0.348, p = 0.003). The results of the present study implicate the promising role of catestatin in the intricate pathophysiology of AF, which should be explored in future research.

20.
J Cardiovasc Electrophysiol ; 34(4): 833-840, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36786515

RESUMO

INTRODUCTION: Pulmonary vein isolation (PVI) is well established as a primary treatment for atrial fibrillation (AF). The POLAR ICE study was designed to collect prospective real world data on the safety and effectiveness of the POLARxTM cryoballoon for PVI to treat paroxysmal AF. METHODS: POLAR ICE, a prospective, non-randomized, multicenter (international) registry (NCT04250714), enrolled 399 patients across 19 European centers. Procedural characteristics, such as time to isolation, cryoablations per pulmonary vein (PV), balloon nadir temperature, and occlusion grade were recorded. PVI was confirmed with entrance block testing. RESULTS: Data on 372 de novo PVI procedures (n = 2190 ablations) were collected. Complete PVI was achieved in 96.8% of PVs. Procedure and fluoroscopy times were 68.2 ± 24.6 and 15.6 ± 9.6 min, respectively. Left atrial dwell time was 46.6 ± 18.3 min. Grade 3 or 4 occlusion was achieved in 98.2% of PVs reported and 71.2% of PVs isolation required only a single cryoablation. Of 2190 cryoapplications, 83% had a duration of at least 120 s; nadir temperature of these ablations averaged -56.3 ± 6.5°C. There were 6 phrenic nerve palsy events, 2 of which resolved within 3 months of the procedure. CONCLUSION: This real-world usage data on a novel cryoballoon suggests this device is effective, safe, and relatively fast in centers with cryoballoon experience. These data are comparable to prior POLARx reports and in keeping with reported data on other cryoballoons. Future studies should examine the long-term outcomes and the relationship between biophysical parameters and outcomes for this novel cryoballoon.


Assuntos
Fibrilação Atrial , Humanos , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Átrios do Coração , Fluoroscopia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA