Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Curr Probl Cardiol ; 48(12): 101936, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37433413

RESUMO

Heart failure (HF) is prevalent among patients with aortic stenosis and presents a poor prognosis. In order to better portray outcomes for HF patients undergoing transcatheter aortic valve replacement (TAVR), we evaluated clinical outcomes in patients with systolic vs diastolic heart failure who underwent TAVR in a large nationwide database. We searched the National Inpatient Sample (NIS) for hospitalized adult patients who underwent TAVR with coexisting history of systolic (SHF) or diastolic heart failure (DHF) as a secondary diagnosis using the ICD-10 codes. The primary outcome was in-hospital mortality, with secondary outcomes of cardiac arrest (CA), cardiogenic shock (CS), respiratory failure (RF), Non-ST elevation myocardial infarction (NSTEMI), acute kidney injury (AKI), use of cardiac and respiratory assist device, and health care utilization defined as length of stay, average hospital cost (AHC) and patient charge (APC). Both univariate and multivariate logistic, generalized linear, and Poisson regression analyses were used to evaluate and test the outcomes. A P-value of <0.05 was significant. A total of 106,815 patients were admitted to acute care hospitals for TAVR, and 73% had a secondary diagnosis of heart failure (41% had SHF and 59% DHF). SHF group were older (mean age of 78.9 years [SD ± 8.9] vs 79.9 years [SD ± 8.3]) with more males (61.8% vs 48.2%) and white predominant (whites [85.9% vs 87.9%]). Compared to DHF, SHF had higher inpatient mortality (1.75% vs 1.14%, P = 0.003), CA (1.31% vs 0.81%, P = 0.01), NSTEMI (2.52% vs 1.0%, P = 0.001), RF (10.87% vs 8.01%, P = 0.001), and CS (3.94% vs 1.14%, P = 0.001). In addition, SHF had greater LOS (5.1 days vs. .3.9, P = 0.0001) & AHC ($52,901 vs $48,070, P = 0.0001). HF is common among patients admitted for TAVR. SHF had worse CV outcomes, greater use of hospital resources, and higher acute care hospital mortality compared to those with DHF.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca Diastólica , Insuficiência Cardíaca Sistólica , Implante de Prótese de Valva Cardíaca , Infarto do Miocárdio sem Supradesnível do Segmento ST , Substituição da Valva Aórtica Transcateter , Masculino , Adulto , Humanos , Idoso , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Insuficiência Cardíaca Sistólica/etiologia , Insuficiência Cardíaca Sistólica/cirurgia , Insuficiência Cardíaca Diastólica/etiologia , Insuficiência Cardíaca Diastólica/cirurgia , Fatores de Risco , Resultado do Tratamento , Estenose da Valva Aórtica/cirurgia
2.
Am J Emerg Med ; 33(9): 1178-83, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26058890

RESUMO

OBJECTIVES: The goal of this study was to determine if emergency physicians (EPs) can correctly perform a bedside diastology examination (DE) and correctly grade the level of diastolic function with minimal additional training in echocardiography beyond what is learned in residency. We hypothesize that EPs will be accurate at detecting and grading diastolic dysfunction (DD) when compared to a criterion standard interpretation by a cardiologist. METHODS: We conducted a prospective, observational study on a convenience sample of adult patients who presented to an urban emergency department with a chief concern of dyspnea. All patients had a bedside echocardiogram, including a DE, performed by an EP-sonographer who had 3 hours of didactic and hands-on echocardiography training with a cardiologist. The DE was interpreted as normal, grade 1 to 3 if DD was present, or indeterminate, all based on predefined criteria. This interpretation was compared to that of a cardiologist who was blinded to the EPs' interpretations. RESULTS: We enrolled 62 patients; 52% had DD. Using the cardiology interpretation as the criterion standard, the sensitivity and specificity of the EP-performed DE to identify clinically significant diastolic function were 92% (95% confidence interval [CI], 60-100) and 69% (95% CI, 50-83), respectively. Agreement between EPs and cardiology on grade of DD was assessed using κ and weighted κ: κ = 0.44 (95% CI, 0.29-0.59) and weighted κ = 0.52 (95% CI, 0.38-0.67). Overall, EPs rated 27% of DEs as indeterminate, compared with only 15% by cardiology. For DEs where both EPs and cardiology attempted an interpretation (indeterminates excluded) κ = 0.45 (95% CI, 0.26 to 0.65) and weighted κ = 0.54 (95% CI, 0.36-0.72). CONCLUSION: After limited diastology-specific training, EPs are able to accurately identify clinically significant DD. However, correct grading of DD, when compared to a cardiologist, was only moderate, at best. Our results suggest that further training is necessary for EPs to achieve expertise in grading DD.


Assuntos
Competência Clínica , Medicina de Emergência/normas , Insuficiência Cardíaca/classificação , Insuficiência Cardíaca/diagnóstico por imagem , Testes Imediatos , Cardiologia , Diástole , Dispneia/etiologia , Serviço Hospitalar de Emergência/normas , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Ultrassonografia
5.
Circ Cardiovasc Imaging ; 6(5): 776-83, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23926194

RESUMO

BACKGROUND: The prevalence of prosthesis-patient mismatch (PPM) and its impact on survival after aortic valve replacement have not been clearly defined. Historically, the presence of PPM was identified from postoperative echocardiograms or preoperative manufacturer-provided charts, resulting in wide discrepancies. The 2009 American Society of Echocardiography (ASE) guidelines proposed an algorithmic approach to calculate PPM. This study compared PPM prevalence and its impact on survival using 3 modalities: (1) the ASE guidelines-suggested algorithm (ASE PPM); (2) the manufacturer-provided charts (M PPM); and (3) the echocardiographically measured, body surface area-indexed, effective orifice area (EOAi PPM) measurement. METHODS AND RESULTS: A total of 614 patients underwent aortic valve replacement with bovine pericardial valves from 2004 to 2009 and had normal preoperative systolic function. EOAi PPM was severe if EOAi was ≤ 0.60 cm(2)/m(2), moderate if EOAi was 0.60 to 0.85 cm(2)/m(2), and absent (none) if EOAi was ≥ 0.85 cm(2)/m(2). ASE PPM was severe in 22 (3.6%), moderate in 6 (1%), and absent (none) in 586 (95.4%). ASE PPM was similar to manufacturer-provided PPM (P=1.00). ASE PPM differed significantly from EOAi PPM (P<0.001), which identified severe mismatch in 170 (29.7%), moderate in 191 (33.4%), and absent (none) in 211 patients (36.9%). Irrespective of the PPM classification method, PPM did not adversely affect midterm survival (average follow-up, 4.1 ± 1.8 years; median, 3.9 years; range, 0.01-8 years). There were no reoperations for PPM. CONCLUSIONS: In patients with normal systolic function undergoing bovine pericardial aortic valve replacement, the prevalence of PPM using the algorithmic-ASE approach was low and correlated well with manufacturer-provided PPM. Independent of the method of PPM assessment, PPM was not associated with medium-term mortality.


Assuntos
Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Bioprótese , Ecocardiografia/métodos , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Animais , Valva Aórtica/fisiopatologia , Bovinos , Distribuição de Qui-Quadrado , Ecocardiografia/normas , Feminino , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/mortalidade , Doenças das Valvas Cardíacas/fisiopatologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Interpretação de Imagem Assistida por Computador , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Guias de Prática Clínica como Assunto , Valor Preditivo dos Testes , Desenho de Prótese , Fatores de Risco , Sístole , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
7.
Clin Case Rep ; 1(2): 91-5, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25356220

RESUMO

KEY CLINICAL MESSAGE: A 50-year-old lady presented with epigastralgia, electrocardiogram (ECG) showed T-wave inversions and the echocardiogram low ejection fraction (EF) with apical ballooning. An esophagogastroduodenoscopy (EGD) revealed gastritis. She recovered with proton pump inhibitors treatment. This is the first case that describes gastritis-induced stress cardiomyopathy. Clinicians should be aware of Takotsubo's cardiomyopathy (TCM) as a possible complication of gastritis.

8.
Curr Cardiol Rep ; 12(3): 265-71, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20424971

RESUMO

The evaluation of valvular and nonvalvular structures is of central importance in the diagnosis, management, and treatment of infective endocarditis (IE). The incidence of IE has remained constant due to changing substrate, with notably higher prevalence observed in the elderly. Mortality and morbidity continue to remain high, despite advances in medical and surgical treatment. This article reviews the technical and practical aspects of the use of echocardiography to evaluate patients with suspected IE.


Assuntos
Ecocardiografia , Endocardite/diagnóstico por imagem , Cardiopatia Reumática/diagnóstico por imagem , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Endocardite/diagnóstico , Endocardite/tratamento farmacológico , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Infecções Relacionadas à Prótese/etiologia , Cardiopatia Reumática/diagnóstico , Cardiopatia Reumática/tratamento farmacológico , Medição de Risco , Staphylococcus aureus
9.
Catheter Cardiovasc Interv ; 68(1): 8-10, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16764004

RESUMO

OBJECTIVES: To determine the utility of multislice computed tomography (MSCT) technology to evaluate coronary stent luminal diameter. BACKGROUND: Stent metal induced "blooming" artifact makes quantitative coronary angiography by MSCT difficult. There is a paucity of data on the efficacy of using 64 and 16 detector MSCT in evaluating coronary stents. METHODS: We evaluated four commercially available bare metal and polymer coated drug eluting stents using 64 and 16 detector MSCT for the following: (1) Strut density in Hounsfield's Units (Hu) using a 2 mm MIP; (2) In-stent luminal diameter (ISLD) measured by MSCT compared to intravascular ultrasound (IVUS). RESULTS: Increased strut thickness did not correlate with greater strut density as measured in Hu (R(2) = 0.05, P = 0.29). The ISLD by 16 MSCT vs. IVUS is: Vision 1.63 +/- 0.58 mm vs. 2.8 +/- 0.0; Cypher 1.80 +/- 0.00 vs. 2.9 +/- 0.0; Taxus 1.87 +/- 0.58 vs. 2.9 +/- 0.0; Liberté 1.80 +/- 0.10 vs. 3.0 +/- 0.1 (P < 0.01). ISLD determined by 64 MSCT vs. IVUS is: Vision 1.73 +/- 0.06 mm vs. 2.8 +/- 0.0; Cypher 1.87 +/- 0.12 vs. 2.9 +/- 0.0; Taxus 1.77 +/- 0.06 vs. 2.9 +/- 0.0; Liberté 1.80 +/- 0.10 vs. 3.0 +/- 0.1 (P < 0.01). CONCLUSIONS: When compared to IVUS measurements, MSCT results in a significant, underestimation of ISLD. This consistent underestimation (even with 64 MSCT) limits the applicability of CT angiography to quantify in-stent restenosis.


Assuntos
Artefatos , Angiografia Coronária , Stents , Tomografia Computadorizada por Raios X/instrumentação , Angiografia Coronária/métodos , Reestenose Coronária/diagnóstico por imagem , Humanos , Projetos Piloto , Desenho de Prótese , Reprodutibilidade dos Testes , Ultrassonografia de Intervenção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA