Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Head Face Med ; 20(1): 24, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627712

RESUMO

OBJECTIVES: A randomized controlled clinical trial of dental implants was conducted to compare the clinical properties of a novel electrochemically deposited calcium phosphate coating to those of a common marketed surface treatment. MATERIAL AND METHODS: Forty implants of the same brand and type were placed in 20 fully edentulous participants requiring mandibular implantation. The two study groups were defined by the surface treatment of the implants. 20 implants in the control group were coated via a commercial electrochemical surface treatment that forms a mixture of brushite and hydroxyapatite, while the remaining 20 in the test group were coated with a novel electrochemical Smart Bioactive Trabecular Coating (SBTC®). A split-mouth design was employed, with each participants receiving one control implant in one mandibular side and a test implant in the other. To mitigate potential operator-handedness bias, control and test implants were randomly assigned to mandibular sides. All cases underwent digital planning, implant placement with a static surgical guide, and participants received locator-anchored full-arch dentures. The primary outcome was implant stability (measured using Osstell ISQ) assessed at insertion, loading, and then 3 months, 9 months, and 2 years post-insertion. The secondary outcome was bone level change (in millimeters) over the 2-year observation period. Oral health-related quality of life (OHRQL) was monitored using the OHIP-14 questionnaire. Complications and adverse events were recorded. RESULTS: Successful osseointegration and implant stability were achieved in all cases, allowing loading. ISQ values steadily increased throughout the observation period. While no significant differences were observed between the SBTC® and control coatings, the test group exhibited a higher ISQ gain. Bone resorption was somewhat lower in the SBTC® but not significantly so. Patients' OHRQL significantly improved after denture delivery and remained stable throughout the follow-up. No complications or adverse events were observed. CONCLUSIONS: Based on the study results, we conclude that the new surface treatment is a safe alternative to the widely used control surface, demonstrating similar osseointegrative properties and time-dependent bone level changes. Further research may explore the broader implications of these findings. TRIAL REGISTRATION: The study is registered on clinicaltrials.gov under the identifier ID: NCT06034171.


Assuntos
Implantes Dentários , Boca Edêntula , Humanos , Implantação Dentária Endóssea/métodos , Qualidade de Vida , Osseointegração , Resultado do Tratamento , Prótese Dentária Fixada por Implante/métodos , Planejamento de Prótese Dentária
2.
Dent J (Basel) ; 11(9)2023 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-37754323

RESUMO

OBJECTIVE: This study aimed to identify the key aspects of patients' dental care experience that influenced their self-perceived satisfaction and loyalty. Also examined was the agreement between patients and dentists regarding these factors. METHODS: Questionnaires were administered to 1121 patients and 77 dentists, focusing on demographic information and 15 selected items related to the patients' last dental visit. Descriptive and linear regression analyses were conducted. RESULTS: The study included participants from 41 practices. Factors significantly influencing satisfaction and loyalty included location convenience, treatment quality, trust in dentists' decisions, visit frequency satisfaction, clear treatment explanations, dentist's interest in symptoms, patient-dental personnel attachment, and dentist's knowledge of the patient and their medical records. While overall agreement between patients and dentists was high, some areas exhibited notable disagreement. CONCLUSIONS: The findings mostly align with existing literature, underscoring the importance of communication, trust, and a personal patient-dentist relationship in promoting satisfaction and loyalty. However, they also show that local, generally not reported factors might be at play, which necessitates dentists' awareness and consideration of the local context for optimal outcomes.

3.
J Pers Med ; 13(5)2023 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-37240930

RESUMO

Introduction: There is a well-documented association between coronary artery disease (CHD) and periodontal disease (PD) mediated by common inflammatory pathways. This association, however, has not been investigated extensively in the special context of in-stent restenosis. This study aimed to investigate the periodontal status of patients undergoing percutaneous coronary intervention (PCI) for restenotic lesions. Methods and Results: We enrolled 90 patients undergoing percutaneous coronary intervention and 90 age- and gender-matched healthy controls in the present study. All subjects received a full-mouth examination by a periodontist. Plaque index, periodontal status, and tooth loss were determined. The periodontal state was significantly worse (p < 0.0001) in the PCI group, and each periodontal stage increased the odds of belonging to the PCI group. This effect of PD was independent of diabetes mellitus, another strong risk factor for CAD. The PCI group was further divided into two subgroups: PCI for restenotic lesions (n = 39) and PCI for de novo lesions (n = 51). Baseline clinical and procedural characteristics were comparable between the two PCI subgroups. A significant (p < 0.001) association was found between the PCI subgroup and the severity of periodontal disease, with the incidence of severe PD reaching 64.1%. Conclusions: Patients undergoing PCI for in-stent restenosis exhibit more severe forms of periodontal disease not only as compared to healthy controls but also as compared to patients stented for de novo lesions. The potential causality between PD and restenosis must be studied in larger prospective studies.

4.
Int Dent J ; 72(5): 691-697, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35810011

RESUMO

OBJECTIVE: Since the outbreak of SARS-CoV-2, aerosol control in the operatory has become a key safety issue in dentistry. The utilisation of extraoral scavenger devices (EOSs) is one of the various approaches to in-treatment aerosol reduction in dentistry. The use and efficacy of EOSs in dental settings, however, are still a matter of debate in the literature and there are still open questions about their proper use. Thus, research into this area is essential to inform dental practice. The objective of this study was to examine the aerosol reduction efficacy of two different EOS in vitro. METHODS: Two commercially available EOSs were tested during modeled dental treatment in a setup that previously proved to generate high aerosol load. Measurements were done in two particle size ranges: 5.6-560 nm (the full range of the spectrometer) and 60.4-392.4 nm (a range that is especially relevant to the spread of SARS-CoV-2 with aerosol). RESULTS: Both devices managed to reduce the aerosol load to a statistically significant extent as compared to the scenario when only a high-volume evacuator and a saliva ejector (and no EOS) were used. CONCLUSIONS: Within the limitations of the study, the results support the assumption that EOSs for aerosol reduction increase in-treatment safety in the dental operatory.


Assuntos
COVID-19 , SARS-CoV-2 , COVID-19/prevenção & controle , Humanos , Aerossóis e Gotículas Respiratórios
5.
J Stomatol Oral Maxillofac Surg ; 123(4): 388-394, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-34601166

RESUMO

PURPOSE: Static guided trephine apicoectomy has been developed as a less invasive and more accurate alternative to conventional freehand apicoectomy with drills. Overpenetration is a frequent issue with this procedure, which deteriorates accuracy and raises safety concerns. A safety improvement to address this problem is presented. MATERIALS AND METHODS: Guided apicoectomies were performed in porcine mandibles with either a conventional bone trephine or a custom-made endo-trephine with built-in depth control. The deviation of the apical endpoint of the trephine from the digital surgical plan was analyzed. Overpenetration frequency was recorded. RESULTS: Procedures performed with the custom trephine were significantly more accurate both along the x-axis and globally, but no significant difference was found for the y and z axes. Overpenetration frequency was 70% in the conventional trephine group versus 38% in the stop trephine group. CONCLUSION: The results indicate that the lack of physical depth control can interfere with the accuracy (and safety) of these procedures to a significant extent, as visual cues (such as the depth markings on a conventional trephine) are insufficient to prevent overpenetration. Our results show that custom-made trephines with a built-in stop offer an optimal solution for this problem.


Assuntos
Apicectomia , Tomografia Computadorizada de Feixe Cônico , Animais , Humanos , Mandíbula/cirurgia , Microcirurgia/métodos , Impressão Tridimensional , Suínos
6.
PLoS One ; 16(2): e0246543, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33539439

RESUMO

Dental turbines and scalers, used every day in dental operatories, feature built-in water spray that generates considerable amounts of water aerosol. The problem is that it is not exactly known how much. Since the outbreak of COVID-19, several aerosol safety recommendations have been issued-based on little empirical evidence, as almost no data are available on the exact aerosol concentrations generated during dental treatment. Similarly, little is known about the differences in the efficacy of different commercially available aerosol control systems to reduce in-treatment aerosol load. In this in vitro study, we used spectrometry to explore these questions. The time-dependent effect of conventional airing on aerosol concentrations was also studied. Everyday patient treatment situations were modeled. The test setups were defined by the applied instrument and its spray direction (high-speed turbine with direct/indirect airspray or ultrasonic scaler with indirect airspray) and the applied aerosol control system (the conventional high-volume evacuator or a lately introduced aerosol exhaustor). Two parameters were analyzed: total number concentration in the entire measurement range of the spectrometer and total number concentration within the 60 to 384 nm range. The results suggest that instrument type and spray direction significantly influence the resulting aerosol concentrations. Aerosol generation by the ultrasonic scaler is easily controlled. As for the high-speed turbine, the efficiency of control might depend on how exactly the instrument is used during a treatment. The results suggest that scenarios where the airspray is frequently directed toward the air of the operatory are the most difficult to control. The tested control systems did not differ in their efficiency, but the study could not provide conclusive results in this respect. With conventional airing through windows with a standard fan, a safety airing period of at least 15 minutes between treatments is recommended.


Assuntos
Aerossóis/efeitos adversos , Instrumentos Odontológicos/virologia , Odontologia/métodos , Aerossóis/administração & dosagem , Aerossóis/análise , COVID-19/etiologia , Desenho de Equipamento , Humanos , Tamanho da Partícula , SARS-CoV-2/isolamento & purificação
7.
Spec Care Dentist ; 40 Suppl 1: 3-81, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33202040

RESUMO

BACKGROUND: Inherited epidermolysis bullosa (EB) is a genetic disorder characterized by skin fragility and unique oral features. AIMS: To provide (a) a complete review of the oral manifestations in those living with each type of inherited EB, (b) the current best practices for managing oral health care of people living with EB, (c) the current best practices on dental implant-based oral rehabilitation for patients with recessive dystrophic EB (RDEB), and (d) the current best practice for managing local anesthesia, principles of sedation, and general anesthesia for children and adults with EB undergoing dental treatment. METHODS: Systematic literature search, panel discussion including clinical experts and patient representatives from different centers around the world, external review, and guideline piloting. RESULTS: This article has been divided into five chapters: (i) general information on EB for the oral health care professional, (ii) systematic literature review on the oral manifestations of EB, (iii) oral health care and dental treatment for children and adults living with EB-clinical practice guidelines, (iv) dental implants in patients with RDEB-clinical practice guidelines, and (v) sedation and anesthesia for adults and children with EB undergoing dental treatment-clinical practice guidelines. Each chapter provides recommendations on the management of the different clinical procedures within dental practice, highlighting the importance of patient-clinician partnership, impact on quality of life, and the importance of follow-up appointments. Guidance on the use on nonadhesive wound care products and emollients to reduce friction during patient care is provided. CONCLUSIONS: Oral soft and hard tissue manifestations of inherited EB have unique patterns of involvement associated with each subtype of the condition. Understanding each subtype individually will help the professionals plan long-term treatment approaches.


Assuntos
Anestesia Dentária , Epidermólise Bolhosa Distrófica , Epidermólise Bolhosa , Adulto , Criança , Humanos , Saúde Bucal , Guias de Prática Clínica como Assunto , Qualidade de Vida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...