Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Clin Ophthalmol ; 16: 2595-2608, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35992568

RESUMO

Purpose: To compare the reproducibility of two-dimensional (2D) peripapillary retinal nerve fiber layer (RNFL) thickness and three-dimensional (3D) neuroretinal rim measurements using spectral domain optical coherence tomography (SDOCT) in normal and glaucoma subjects. Methods: One eye per subject for 27 normal and 40 glaucoma subjects underwent repeat SDOCT RNFL thickness scans and optic nerve volume scans on the same day. From the volume scan, custom software calculated five neuroretinal rim parameters: 3D minimum distance band (MDB) thickness, 3D MDB area, 3D rim volume, 2D rim area, and 2D rim thickness. Within-subject variance (Sw), coefficient of variation (CV), and intraclass correlation coefficient (ICC) were analyzed. Results: MDB thickness and RNFL thickness have similar reproducibility among normal and glaucoma subjects (eg, global MDB thickness CVs of 2.4% and 3.6%, and global RNFL thickness CVs of 1.3% and 2.2%; P > 0.05 for both comparisons). Reproducibility of MDB thickness was lower in glaucoma patients for the superior and inferior quadrants compared to normal subjects (CVs of 9.6% versus 3.4% and 6.9% versus 2.7%; P < 0.05, respectively). There were no statistically significant differences between both groups for RNFL thickness in the four quadrants. For both patient groups and for all regions, MDB thickness had the lowest CVs among all five neuroretinal rim parameters (eg, global MDB thickness CVs of 2.4% and 3.6% versus 3.0% and 18.9% for the other four neuroretinal rim parameters). Conclusion: Global MDB and global RNFL thickness are similarly reproducible among normal and glaucoma subjects, though MDB thickness for the superior and inferior quadrants is less reproducible among glaucoma subjects.

2.
Transl Vis Sci Technol ; 10(6): 28, 2021 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-34019635

RESUMO

Purpose: To assess the structure-function relationship in glaucoma using Humphrey visual field (HVF) perimetry and a three-dimensional neuroretinal rim parameter derived from spectral domain optical coherence tomography (SD-OCT) volume scans. Methods: Structure-function correlation was analyzed globally and regionally (four quadrants and four sectors). Structural data included peripapillary retinal nerve fiber layer (RNFL) thickness and minimum distance band (MDB) neuroretinal rim thickness, defined as the shortest distance between the inner cup surface and the outer retinal pigment epithelium/Bruch's membrane complex. Logarithmic regression analyses were performed and Pearson correlation coefficients determined to assess relationship strength. Results: The study consisted of 102 open-angle glaucoma patients and 58 healthy subjects. The Pearson correlation coefficient for global MDB thickness (R = 0.585) was higher than for global RNFL thickness (R = 0.492), but the difference was not statistically significant (P = 0.18). The correlation coefficients for regional MDB thicknesses and corresponding HVF sensitivities were higher than those for regional RNFL thicknesses and HVF in six out of eight regions (P = 0.08 to 0.47). In the remaining two out of eight regions, the correlation coefficients were higher for RNFL thickness than for MDB thickness (P = 0.15 to 0.20). Conclusions: Three-dimensional MDB neuroretinal rim thickness relates to visual function as strongly as the most commonly used SD-OCT parameter for glaucoma, two-dimensional peripapillary RNFL thickness. Translational Relevance: This paper illustrates the potential for 3D OCT algorithms to improve in vivo imaging in glaucoma.


Assuntos
Glaucoma de Ângulo Aberto , Disco Óptico , Glaucoma de Ângulo Aberto/diagnóstico , Humanos , Fibras Nervosas , Disco Óptico/diagnóstico por imagem , Células Ganglionares da Retina , Tomografia de Coerência Óptica
3.
J Glaucoma ; 28(11): 979-988, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31599775

RESUMO

PRéCIS:: Neuroretinal rim minimum distance band (MDB) thickness is significantly lower in older subjects and African Americans compared with whites. It is similar in both sexes. PURPOSE: To evaluate the relationship between age, race, and sex with the neuroretinal rim using high-density spectral-domain optical coherence tomography optic nerve volume scans of normal eyes. METHODS: A total of 256 normal subjects underwent Spectralis spectral-domain optical coherence tomography optic nerve head volume scans. One eye was randomly selected and analyzed for each subject. Using custom-designed software, the neuroretinal rim MDB thickness was calculated from volume scans, and global and quadrant neuroretinal rim thickness values were determined. The MDB is a 3-dimensional neuroretinal rim band comprised of the shortest distance between the internal limiting membrane and the termination of the retinal pigment epithelium/Bruch's membrane complex. Multiple linear regression analysis was performed to determine the associations of age, race, and sex with neuroretinal rim MDB measurements. RESULTS: The population was 57% female and 69% white with a mean age of 58.4±15.3 years. The mean MDB thickness in the normal population was 278.4±47.5 µm. For this normal population, MDB thickness decreased by 0.84 µm annually (P<0.001). African Americans had thinner MDBs compared with whites (P=0.003). Males and females had similar MDB thickness values (P=0.349). CONCLUSION: Neuroretinal rim MDB thickness measurements decreased significantly with age. African Americans had thinner MDB neuroretinal rims than whites.


Assuntos
Envelhecimento/fisiologia , Fibras Nervosas , Disco Óptico/anatomia & histologia , Grupos Raciais/estatística & dados numéricos , Retina/anatomia & histologia , Células Ganglionares da Retina/citologia , Adulto , Idoso , Paquimetria Corneana , Estudos Transversais , Feminino , Gonioscopia , Humanos , Imageamento Tridimensional , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Disco Óptico/diagnóstico por imagem , Estudos Prospectivos , Retina/diagnóstico por imagem , Fatores Sexuais , Microscopia com Lâmpada de Fenda , Tomografia de Coerência Óptica/métodos , Tonometria Ocular , Testes de Campo Visual
4.
Ann Fam Med ; 17(Suppl 1): S33-S39, 2019 08 12.
Artigo em Inglês | MEDLINE | ID: mdl-31405874

RESUMO

PURPOSE: We describe the results of a practice transformation project conducted within a national cohort of optometry practices participating in the Southern New England Practice Transformation Network. METHODS: Participants were 2,997 optometrists in 1,706 practices in 50 states. The multicomponent intervention entailed curriculum dissemination through a preexisting network of optometrists supported by specialized staff and resources, and data collection through a web portal providing real-time feedback. Outcomes included practices reporting data, urgent optometry visits for target conditions, and projected cost savings achieved by reducing emergency department (ED) use through increased provision of urgent care for conditions amenable to management in optometry practices. RESULTS: Over 13 months, 69.9% of practices reported data for a mean of 6.7 months. Beginning with the fourth month, the number of urgent optometry visits increased steadily. Among reporting practices, the total cost savings were estimated at $152 million (176,703 ED visits avoided at an average cost differential of $860 per visit). Monthly projected cost savings per optometrist were substantially greater in rural vs urban practices ($10,800 vs $7,870; P <.001). CONCLUSIONS: Technical assistance to promote practice transformation can be provided remotely and at scale at low per-practice cost. Through the provision of timely, easily accessed ambulatory care, optometrists can improve the patient experience and reduce ED use, thereby reducing costs. The cost savings opportunities are immense because of the large volume and high expense of ED visits for ocular conditions that might otherwise be managed in ambulatory optometry practices.


Assuntos
Instituições de Assistência Ambulatorial/organização & administração , Redução de Custos/estatística & dados numéricos , Serviço Hospitalar de Emergência/estatística & dados numéricos , Optometria/organização & administração , Instituições de Assistência Ambulatorial/estatística & dados numéricos , Estudos de Coortes , Oftalmopatias/diagnóstico , Oftalmopatias/economia , Oftalmopatias/terapia , Humanos , New England , Optometria/estatística & dados numéricos , População Rural , População Urbana
5.
Transl Vis Sci Technol ; 7(6): 12, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30510856

RESUMO

PURPOSE: To evaluate the effects of age, race, and ethnicity on the optic nerve and peripapillary retina using spectral-domain optical coherence tomography (SD-OCT) three-dimensional (3D) volume scans in normal subjects. METHODS: This is a cross-sectional study performed at a single institution in Boston. All patients received retinal nerve fiber layer (RNFL) scans and an optic nerve 3D volume scan. The SD-OCT software calculated peripapillary RNFL thickness, retinal thickness (RT), and retinal volume (RV). Custom-designed software calculated neuroretinal rim minimum distance band (MDB) thickness and area. RESULTS: There were 272 normal subjects, including 175 whites, 40 blacks, 40 Asians, and 17 Hispanics. Rates of age-related decline were 2.3%, 2.0%, 1.7%, 3.3%, and 4.3% per decade for RNFL, RT, RV, MDB neuroretinal rim thickness, and MDB area, respectively. The RNFL was most affected by racial and ethnic variations, with Asians having thicker global, superior, and inferior RNFL, Hispanics having thicker inferior RNFL, and blacks having thinner temporal RNFL, compared to whites. For MDB thickness and area, Asians had smaller nasal values and blacks had smaller temporal values. Peripapillary RT and RV parameters were not influenced by race and ethnicity. CONCLUSIONS: All of the parameters exhibited age-related declines. RNFL, MDB thickness, and MDB area demonstrated racial and ethnic variations, while peripapillary RT and RV did not. TRANSLATIONAL RELEVANCE: This study demonstrates that both normal aging and ethnicity affect several novel 3D OCT parameters used to diagnose and monitor glaucoma (i.e., RT, RV, and MDB), and this should be factored in when making clinical decisions based on these parameters.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...