Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Semin Arthritis Rheum ; 51(3): 644-649, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33468347

RESUMO

OBJECTIVE: This study aimed to develop (1) a new ultrasound definition for aggregates and (2) a semi-quantitative ultrasound scoring system (0-3) for tophus, double contour and aggregates. Furthermore, the intra- and inter-reader reliabilities of both the re-defined aggregates and the semi-quantitative scoring system were assessed using static image exercises. METHODS: Thirty-seven rheumatologists were invited. A Delphi process was used for re-defining aggregates and for selecting a semi-quantitative scoring system with >75% agreement obligate for reaching consensus. Subsequently, a web-based exercise on static ultrasound images was conducted in order to assess the reliability of both the re-defined aggregates and the semi-quantitative scoring system. RESULTS: Twenty rheumatologists contributed to all rounds of the Delphi and image exercises. A consensual re-definition of aggregates was obtained after three Delphi rounds but needed an overarching principle for scoring aggregates in patients. A consensus-based semi-quantitative ultrasound scoring system for gout lesions was developed after two Delphi rounds. The re-definition of aggregates showed good intra- and inter-reader reliability (κ-values 0.71 and 0.61). The reliabilities of the scoring system were good for all lesions with slightly higher intra-reader (κ-values 0.74-0.80) than inter-reader reliabilities (κ-values 0.61-0.67). CONCLUSION: A re-definition of aggregates was obtained with a good reliability when assessing static images. The first consensus-based semi-quantitative ultrasound scoring system for gout-specific lesions was developed with good inter- and intra-reader reliability for all lesions when tested in static images. The next step is to assess the reliabilities when scoring lesions in patients.


Assuntos
Gota , Consenso , Exercício Físico , Gota/diagnóstico por imagem , Humanos , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Ultrassonografia
3.
Rheumatology (Oxford) ; 57(11): 1991-2000, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-30053219

RESUMO

Objective: To compare the performance of different spinal radiographic damage scoring methods in patients with early axial spondyloarthritis (axSpA). Methods: Five-year spinal radiographs from the DESIR cohort were scored by three readers (averaged) for the calculation of the Stoke AS Spine Score (SASSS), modified Stoke Ankylosing Spondylitis Spine Score (mSASSS), Radiographic AS Spinal Score (RASSS), BASRI-spine and BASRI-total, and following the OMERACT filter, scores were compared according to truth, discrimination (reliability and sensitivity to change) and feasibility. The proportion of patients with a net change > smallest detectable change and >1 was calculated. The proportion of total variance explained by the patient (true variance) was calculated for the change scores as a measure of reliability, using analysis of variance. Results: In total 699 patients were included. Five-year net changes > smallest detectable change (>1) were: RASSS 17% (17%), mSASSS 12% (12%), BASRI-spine and BASRI-total 12% (9%), SASSS 11% (11%). The mSASSS and the RASSS performed the best in terms of capturing the signal (positive change) related to noise (negative change). The proportion of variance explained by the patient was highest for the mSASSS and RASSS (85% for both 5-year progression scores vs 50-55% for other methods). The proportion of patient variance in the thoracic segment of the RASSS was unsatisfactory (46% for progression). Conclusion: The existing scoring methods to assess spinal radiographic damage performed well in early phases of axSpA. The mSASSS and RASSS captured most change. There was no clear gain in additionally scoring the thoracic spine for the RASSS. The mSASSS remains the most sensitive and valid scoring method in axSpA, including early phases of the disease.


Assuntos
Coluna Vertebral/diagnóstico por imagem , Espondilartrite/diagnóstico por imagem , Adulto , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
4.
Isr Med Assoc J ; 19(11): 703-707, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29185287

RESUMO

BACKGROUND: Over the last 15 years ultrasound has gained importance for the clinical management of patients with inflammatory rheumatic diseases, especially rheumatoid arthritis. This review summarizes the recent developments and achievements in the use of ultrasound in RA, as well as the unmet needs.


Assuntos
Artrite Reumatoide/diagnóstico , Articulações/diagnóstico por imagem , Ultrassonografia/métodos , Humanos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...