Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
J Clin Med ; 12(3)2023 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-36769398

RESUMO

Pneumothorax is one of the most frequent complications of computed tomography (CT)-guided lung biopsies. We aim to identify the safe zone of the needle-pleura angle during a CT-guided lung biopsy. Fifty-two patients underwent CT-guided lung biopsies between January 2020 and September 2022 (27 males, 25 females, median age 70 years). Right and left needle angles were measured and correlated to the incidence of pneumothorax. The minimum delta (δmin) was calculated as the absolute value of the difference between a 90° angle and the right and left angles. t-test p-values for δmin were conducted. We recorded 29 patients with pneumothorax, including intraprocedural and transient, postprocedural with minimal symptoms, or postprocedural requiring a chest tube insertion. Thirty-two patients had a δmin ≥ 10°, while 20 had a δmin < 10°. Of the patients with a δmin < 10°, 30% experienced pneumothorax compared to 71.8% in patients with δmin ≥ 10° (p = 0.0023). The study results show that as the needle's angle deviates from the perpendicular, with an absolute value of more than 10°, the likelihood of pneumothorax increases significantly. A needle-pleura angle between 80° and 100° gives the operator a safe zone to reduce the risk of pneumothorax.

2.
PLoS One ; 17(7): e0271664, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35862403

RESUMO

OBJECTIVES: Multiple studies show orthopedic health problems for medical staff due to wearing radiation protection aprons. The aim of this study was to evaluate the weight pressure on the shoulder as a marker of physical strain caused by different radiation-protection devices. METHODS: For the weight pressure measurement, a pressure sensor (OMD-30-SE-100N, OptoForce, Budapest, Hungary) placed on the left and right shoulder was used. Wearing different radiation protection systems the force measurement system was used to quantify the weight pressure. Measurements were acquired in still standing position and during various movements. RESULTS: A mean significant decreasing weight pressure on the shoulder between 74% and 84% (p<0.001) was measured, when the free-hanging radiation protection system was used in comparison to one-piece and two-piece radiation protection aprons and coats. Using two-piece radiation protection aprons, the weight pressure was significantly lower than that of one-piece radiation protection coats. If a belt was used for the one-piece radiation protection coat, the weight pressure on the shoulder was reduced by 32.5% (p = 0.003). For a two-piece radiation protection apron and a one-piece radiation protection coat (with and without belt) a significant different weight pressure distribution between the right and left shoulder could be measured. CONCLUSIONS: The free-hanging radiation protection system showed a significant lower weight pressure in comparison to the other radiation protection devices. Apart from this, use of a two-piece radiation protection apron or addition of a belt to a radiation protection coat proved to be further effective options to reduce weight pressure.


Assuntos
Exposição Ocupacional , Proteção Radiológica , Humanos , Hungria , Corpo Clínico , Exposição Ocupacional/análise , Exposição Ocupacional/prevenção & controle , Roupa de Proteção , Doses de Radiação , Radiologia Intervencionista
3.
J Clin Med ; 11(7)2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35407566

RESUMO

The purpose of this study is to assess the effect of nine covariates on the occurrence or absence of stable or symptomatic pneumothorax. Forty-three patients underwent CT-guided lung biopsies from January 2020 to January 2022 (24 m, 19 f, median age 70 years). All the interventions were carried out with a semi-automatic 18G needle and a 17G trocar in a prone or supine position. Different covariates were measured and correlated to the rate and severity of the pneumothoraces observed. Nominal two-sided t-test p-values for the continuous variables and Fisher's exact test results for the categorical variables were conducted. The data included the lesion size, distance to the pleura, needle-pleura angle, age, gender, position during the procedure, and the presence of chronic obstructive pulmonary disease. Patients with an observed pneumothorax had an average angle between the needle and the pleura of 74.00° compared to 94.68° in patients with no pneumothorax (p-value = 0.028). A smaller angle measurement correlated with a higher risk of pneumothorax development. The needle-pleural angle plays a vital role in the outcome of a CT-guided lung biopsy. Correctly adjusting the needle-pleural angle can diminish the pneumothorax risk associated with a CT-guided lung biopsy. The study results show that as the needle's angle deviates from the perpendicular, the pleural surface area experiencing trauma increases, and pneumothorax is more likely to occur.

4.
Radiol Case Rep ; 17(4): 1057-1060, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35154553

RESUMO

Impalement injuries are infrequent yet tend to be life-threatening. Transorbital penetration by foreign bodies represents a peculiar form of traumatic brain injury. However, much is at stake with the high risk of neurological and ophthalmic impairment. We narrate an unusual case of a riding crop penetrating the eye of a 10-year-old girl who presented to our hospital after a fall and an episode of syncope while at a riding stable. Magnetic resonance imaging detected an extended passage-like signal in the right-sided part of the pons and the cerebral peduncles extending to the right cerebellar hemisphere. The patient exhibited marginal clinical symptoms. This case was unsurpassed, as despite the horizontal course of the riding crop perforating the osseous structures and penetrating the brain, it resulted in manageable symptoms, which resolved in a matter of weeks.

5.
Diagn Interv Radiol ; 27(4): 573-579, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34313245

RESUMO

PURPOSE: Studies have demonstrated that positron emission tomography/computed tomography (PET/CT) with Gallium-68 (68Ga)-labeled somatostatin analogues are effective at detecting metastatic disease in neuroendocrine tumors (NET), especially extrahepatic metastases. However, PET in combination with full-dose contrast-enhanced CT (ceCT) exposes patients to higher radiation (~25 mSv). The use of non-contrast-enhanced low-dose CT (ldCT) can reduce radiation to about 10 mSv and may avoid contrast-induced side effects. This study seeks to determine whether ceCT could be omitted from NET assessments. METHODS: We retrospectively compared the performance of PET/ldCT versus PET/ceCT in 54 patients (26 male, 28 female) who had undergone a 68Ga-DOTATATE PET/CT. The selection criteria were as follows: available ldCT and ceCT, histologically confirmed NET, and follow-up of at least 6 months (median, 12.6 months; range, 6.1-23.2 months). The PET/ldCT and PET/ceCT images were analyzed separately. We reviewed metastases in the lungs, bones, and lymph nodes. The results were compared with the reference standard (clinical follow-up data). RESULTS: The PET/ceCT scans detected 139 true-positive bone lesions compared with 140 lesions detected by the PET/ldCT scans, 106 true-positive lymph node metastases (PET/ceCT) compared with 90 metastases detected by the PET/ldCT scans, and 26 true-positive lung lesions (PET/ceCT) compared with 6 lesions detected by the PET/ldCT scans. The overall lesion-based sensitivity for full-dose PET/ceCT was 97%, specificity 86%, negative predictive value (NPV) 93%, and positive predictive value (PPV) 93%. The overall lesion-based sensitivity for PET/ldCT was 85%, specificity 73%, NPV 72%, and PPV 85%. CONCLUSION: This study presents the first evidence that ceCT should not be omitted from extrahepatic staging using 68Ga-DOTATATE PET/CT in patients with NET. ceCT alone can be used as a follow-up to reduce radiation exposure when the patient has already undergone PET/ceCT and suffers from non-DOTATATE-avid NET.


Assuntos
Tumores Neuroendócrinos , Compostos Organometálicos , Feminino , Radioisótopos de Gálio , Humanos , Masculino , Tumores Neuroendócrinos/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
6.
J Craniomaxillofac Surg ; 48(4): 413-420, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32127305

RESUMO

PURPOSE: Condylar head fractures (CHFs) are increasingly treated by open reduction and internal fixation (ORIF). However, there are no reports on the three-dimensional postoperative volumetric transformation of the condyle, especially with regard to fragmented cases. Protruding hardware can lead to severe complications, so the goal of this study was to examine the amount of condylar bony resorption occurring after ORIF. METHODS: Included were surgically treated CHFs with eligible cone beam computer tomography (CBCT) datasets immediately after ORIF (T1) and after implant removal (T2), plus fractures of the condylar neck and base as a reference. 2D vertical and 3D volume changes of the condylar head after ORIF of CHFs were evaluated by CBCT datasets transformed into 3D models for 3D volumetric assessment using Slicer freeware. RESULTS: Among a total of 50 fractures (38 patients), including 41 CHFs (ORIF with titanium positional screws, including 15 minor and 12 major fragmented cases) plus nine extracapsular fractures (eight upper neck and one base fracture), postoperative condylar volume decreased by a mean of 0.27 cm³ (median 0.25 cm³; SD 0.23 cm³) or 16% (median 14%; SD 11%). Major fragmented CHFs showed significantly higher resorption rates (p < 0.001, range 8-42%). Age correlated with a decrease in condylar volume (mean 2.4% per 10 years of age, (p = 0.011). No significant correlation could be established between loss of condylar volume and fracture localization. A protrusion of metallic implants was seen in 20% of the assessed cases. CONCLUSION: Due to substantial volume changes of the condylar head occurring after ORIF, protrusion of implants (both metallic and resorbable) needs to be taken into consideration. An early removal of metallic ostheosyntesis material (around 4 months after ORIF) is strongly recommended to avoid adverse short- and long-term effects.


Assuntos
Fraturas Mandibulares , Fixação Interna de Fraturas , Humanos , Côndilo Mandibular , Redução Aberta , Articulação Temporomandibular , Resultado do Tratamento
7.
World J Surg ; 41(6): 1521-1527, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28138732

RESUMO

BACKGROUND: Routine screening is recommended for patients with multiple endocrine neoplasia type 1 (MEN1) to enable early detection and treatment of associated neuroendocrine neoplasms (NEN). Gallium68-DOTATOC-Positron emission tomography combined with computed tomography (Ga-68-DOTATOC-PET-CT) is a very sensitive and specific imaging technique for the detection of sporadic neuroendocrine tumors. The present study evaluated the value of Ga-68-DOTATOC-PET-CT in routine screening of patients with MEN1. METHODS: Between January 2014 and March 2016, all MEN1 patients underwent Ga-68-DOTATOC-PET-CT in addition to conventional imaging (computed tomography of the thorax, magnetic resonance imaging of the abdomen and pituitary, endoscopic ultrasonography). The diagnostic yield of conventional imaging and Ga-68-DOTATOC-PET-CT was prospectively documented and compared, and treatment changes caused by the addition of Ga-68-DOTATOC-PET-CT were recorded. RESULTS: Conventional imaging detected 145 NENs, mainly pancreaticoduodenal NENs (n = 117, 81%), in 31 of 33 MEN1 patients. Ga-68-DOTATOC-PET-CT detected 55 NENs in 23 of the 33 patients (p = 0.0001). Ninety (62%) NENs detected by conventional imaging were missed by DOTATOC-PET-CT. The majority of missed lesions were pNEN (n = 68; 74%). The sensitivity of Ga-68-DOTATOC-PET-CT for NENs <5, 5-9, 10-19 and ≥20 mm was 0, 29, 81 and 100%, respectively. However, Ga-68-DOTATOC-PET-CT detected more liver and lymph node metastases in patients with known metastatic disease, which did not lead to a change of patients' management. In one patient (3%), Ga-68-DOTATOC-PET-CT was the only imaging modality that detected a small intestine NEN and led to potentially curative surgery. CONCLUSION: Ga-68-DOTATOC-PET-CT cannot be recommended for routine screening of MEN1 patients. It might provide important additional information in patients with suspected or known metastatic disease.


Assuntos
Neoplasia Endócrina Múltipla Tipo 1/diagnóstico por imagem , Octreotida/análogos & derivados , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Compostos Radiofarmacêuticos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
8.
Angiogenesis ; 19(4): 525-35, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27582011

RESUMO

Renal microvascular rarefaction characterizes chronic kidney disease (CKD). In murine models of CKD, micro-CT imaging reflected capillary rarefaction using quantification of renal relative blood volume (rBV). In addition, micro-CT imaging revealed morphological alterations of the intrarenal vasculature including reduced vascular branching and lumen diameter. Here, we retrospectively quantified rBV in contrast-enhanced CT angiography in patients and found that, compared to non-CKD patients, those with CKD and renal fibrosis had significantly reduced rBV in the renal cortex. rBV values closely mirrored capillary rarefaction in the corresponding nephrectomy specimens. In patients with follow-up CT angiography, reduction of renal function was paralleled by a decline in rBV. Using virtual autopsy, i.e., postmortem CT angiography, morphometry of intrarenal arteries in 3D-rendered CT images revealed significantly reduced arterial diameter and branching in CKD compared to non-CKD cases. In conclusion, in CKD patients, contrast-enhanced CT imaging with quantification of rBV correlates with functional renal vasculature, whereas virtual autopsy allows morphometric analyses of macrovascular changes. Importantly, the observed vascular alterations in CKD patients mirror those in animals with progressive CKD, suggesting a high relevance of animal models for studying vascular alterations in CKD and renal fibrosis.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Insuficiência Renal Crônica/diagnóstico por imagem , Idoso , Animais , Volume Sanguíneo , Capilares/diagnóstico por imagem , Capilares/patologia , Estudos de Coortes , Meios de Contraste , Progressão da Doença , Fibrose , Humanos , Imageamento Tridimensional , Rim/irrigação sanguínea , Rim/diagnóstico por imagem , Rim/patologia , Masculino , Microvasos/diagnóstico por imagem , Microvasos/patologia , Pessoa de Meia-Idade , Circulação Renal , Insuficiência Renal Crônica/patologia , Estudos Retrospectivos
9.
Acta Radiol ; 57(10): 1210-6, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26663210

RESUMO

BACKGROUND: Biphasic injection protocols are frequently used because they yield homogenous contrast enhancement. We hypothesize that with faster scanners and shorter scan times, biphasic injection protocols are no longer necessary. PURPOSE: To evaluate whether a monophasic injection protocol is equivalent to a biphasic protocol in terms of contrast enhancement and homogeneity. MATERIAL AND METHODS: Repeated high-pitch CTA (pitch 3) and conventional standard-pitch computed tomography angiography (CTA) (pitch 1.2) from the cervical region to the symphysis was performed in seven beagles (11.2 ± 2.5 kg) in a cross-over study design. Arterial contrast enhancement was measured along the z-axis in the ascending, descending, and abdominal aorta and the iliac arteries. The z-axis is the longitudinal axis of the human body and at the same time the direction in which the CT table is moving. The data were analyzed using repeated measures ANOVA with a post-hoc t-test and visual assessment of the scans. RESULTS: In high-pitch CTA, monophasic injection protocols were superior to biphasic injection protocols in enhancement levels (P < 0.05) and enhancement homogeneity along the z-axis (P < 0.05). In conventional CTA, enhancement levels did not differ. Contrast homogeneity was better for biphasic protocols. CONCLUSION: High-pitch CTA monophasic injection protocols are superior to biphasic injection protocols, due to a higher and more homogeneous contrast enhancement with the same amount of contrast medium used.


Assuntos
Protocolos Clínicos , Angiografia por Tomografia Computadorizada , Meios de Contraste/administração & dosagem , Iohexol/análogos & derivados , Animais , Estudos Cross-Over , Cães , Injeções Intravenosas , Iohexol/administração & dosagem
10.
Neuroendocrinology ; 103(3-4): 240-7, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26113081

RESUMO

OBJECTIVE: The prevalence and clinical behavior of bronchopulmonary neuroendocrine tumors (bNET) associated with multiple endocrine neoplasia type 1 (MEN1) are not well defined. This study aimed to determine the prevalence, potential precursor lesions and prognosis of bNET in patients with MEN1. METHODS: A database of 75 prospectively collected MEN1 cases was retrospectively analyzed for bNET. Patient characteristics, imaging and treatment were evaluated. Resection specimens of operated patients were reassessed by two specialized pathologists. Available CT scans of the whole cohort were reviewed to determine the prevalence of bronchopulmonary nodules. RESULTS: Five of the 75 MEN1 patients (6.6%; 2 male, 3 female) developed histologically confirmed bNET after a median follow-up of 134 months. The median age at diagnosis of bNET was 47 years (range 31-67), and all patients were asymptomatic. Four patients underwent anatomic lung resections with lymphadenectomy; the remaining patient with multiple lesions had only a wedge resection of the largest bNET. Tumor sizes ranged from 7 to 32 mm in diameter, and all bNET were well differentiated. Two patients had lymph node metastases. Two of 4 reevaluated resection specimens revealed multifocal bNET, and 3 specimens showed tumorlets (up to 3) associated with multifocal areas of a neuroendocrine cell hyperplasia within the subsegmental bronchi. One bNET-related death (1.3%) occurred during long-term follow-up. Review of the available CT scans of the patients without proven bNET revealed small bronchopulmonary lesions (≥3 mm) in 16 of 53 cases (30.2%). CONCLUSIONS: bNET in MEN1 might be more common than previously recognized. Their natural course seems to be rather benign. Multifocal tumorlets and multifocal neuroendocrine cell hyperplasia might represent their precursor lesions.


Assuntos
Neoplasias Brônquicas/complicações , Neoplasias Brônquicas/epidemiologia , Neoplasias Pulmonares/complicações , Neoplasias Pulmonares/epidemiologia , Neoplasia Endócrina Múltipla Tipo 1/epidemiologia , Adulto , Idoso , Neoplasias Brônquicas/diagnóstico por imagem , Neoplasias Brônquicas/patologia , Estudos de Coortes , Feminino , Humanos , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/cirurgia , Masculino , Pessoa de Meia-Idade , Neoplasia Endócrina Múltipla Tipo 1/diagnóstico por imagem , Neoplasia Endócrina Múltipla Tipo 1/patologia , Neoplasia Endócrina Múltipla Tipo 1/cirurgia , Tumores Neuroendócrinos/diagnóstico por imagem , Tumores Neuroendócrinos/patologia , Tumores Neuroendócrinos/cirurgia , Tomografia Computadorizada de Emissão
11.
Hum Pathol ; 45(9): 1813-23, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25033728

RESUMO

Postmortem computed tomography (PMCT) is a modern tool that complements autopsy diagnostics. In clinical autopsies, a major cause of death is cardiovascular disease. To improve the performance of PMCT in cardiovascular disease, full body angiography was developed (PMCT angiography [PMCTA]). Twenty PMCTA scans generated before autopsy were compared with native PMCT and clinical autopsy. The objective of the study was to quantify the additional diagnostic value of adding angiography to native imaging and to compare PMCT and PMCTA findings to autopsy findings. The diagnosis of the cause of death was identical or overlapped in 80% of the cases that used PMCTA and 70% that used PMCT. The additional diagnostic yield given by PMCT and PMCTA in combination with autopsy was 55%. PMCT yielded additional diagnoses in the musculoskeletal system. The greatest additional diagnostic value of PMCTA was in association with cardiovascular diagnoses. The accuracy of PMCTA for cardiac causes of death was 80%, and the positive predictive value was 90%. The findings indicate that native PMCT cannot display the cardiovascular system sufficiently clearly for high-quality diagnostic assessment. However, PMCTA is a powerful tool in autopsy cases with a history of cardiovascular disease and/or a suspected cardiovascular cause of death. The combination of PMCTA and clinical autopsy enhances diagnostic quality and completeness of the autopsy report. Furthermore, in cases without consent or with a restricted consent for clinical autopsy, PMCTA has the potential to provide information on cardiovascular causes of death.


Assuntos
Angiografia/métodos , Doenças Cardiovasculares/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Autopsia , Doenças Cardiovasculares/patologia , Causas de Morte , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Patologia Clínica , Adulto Jovem
12.
PLoS One ; 9(4): e93101, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24759757

RESUMO

OBJECTIVES: To evaluate the diagnostic value of contrast enhanced post mortem computed tomography (PMCT) in comparison to non-enhanced post mortem CT in the detection of cardiovascular causes of death (COD). BACKGROUND: As autopsy rates decline, new methods to determine CODs are necessary. So contrast enhanced PMCT shall be evaluated in comparison to established non-enhanced PMCT in order to further improve the method. METHODS: In a prospective study, 20 corpses were examined using a 64-row multisclice CT (MSCT) before and after intraarterial perfusion with a newly developed, barium-bearing contrast agent and ventilation of the lungs. The cause of death was determined in enhanced and unenhanced scans and a level of confidence (LOC) was given by three experienced radiologists on a scale between 0 and 4. Results were compared to autopsy results as gold standard. Autopsy was performed blinded to PMCT-findings. RESULTS: The method allowed visualization of different types of cause of death. There was a significant improvement in LOC in enhanced scans compared to unenhanced scans as well as an improvement in the detection of COD. The cause of death could be determined in 19 out of 20 patients. CONCLUSIONS: PMCT is feasible and appears to be robust for diagnosing cardiovascular causes of death. When compared with unenhanced post-mortem CT intraarterial perfusion and pulmonary ventilation significantly improve visualization and diagnostic accuracy. These promising results warrant further studies.


Assuntos
Autopsia/métodos , Doenças Cardiovasculares/diagnóstico por imagem , Doenças Cardiovasculares/mortalidade , Meios de Contraste , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Cadáver , Causas de Morte , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
13.
Artigo em Inglês | MEDLINE | ID: mdl-24393632

RESUMO

OBJECTIVE: This study was carried out to identify groups of patients who would benefit from this angiography. The angiographic images of a random group of patients were studied; the correlations between the vascular state of the lower extremities and vessel pathology were investigated; and the possible links of these findings with certain medical conditions were explored. STUDY DESIGN: Three experienced observers independently evaluated the angiograms of 185 patients. The status of all 3 vessels of the lower extremities (anterior tibial artery, posterior tibial artery, and peroneal artery) was evaluated. The patients' gender, age, drinking and smoking habits, and medical conditions were documented. RESULTS: We found a significant correlation between pathology of the arteries of the lower extremity and blood cholesterol level, blood pressure, coronary heart disease, diabetes mellitus, and age. CONCLUSIONS: We suggest that preoperative vascular imaging be carried out in patients with comorbidities to reduce the potential for flap failure and to minimize donor site complications.


Assuntos
Angiografia/métodos , Fíbula/irrigação sanguínea , Retalhos Cirúrgicos , Sítio Doador de Transplante/irrigação sanguínea , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Artérias , Comorbidade , Fíbula/transplante , Humanos , Extremidade Inferior/irrigação sanguínea , Extremidade Inferior/diagnóstico por imagem , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Artérias da Tíbia/diagnóstico por imagem , Artérias da Tíbia/patologia , Sítio Doador de Transplante/diagnóstico por imagem
14.
Eur J Radiol ; 82(12): 2348-52, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24113432

RESUMO

PURPOSE: To investigate the quantitative and qualitative differences between combined positron emission tomography and computed X-ray tomography (PET/CT) enhanced with contrast medium with either an iodine concentration 300 mg/ml or 370 mg/ml. MATERIALS AND METHODS: 120 consecutive patients scheduled for F-18-Fluorodeoxyglucose (FDG) PET/CT were included. The first (second) 60 patients received contrast medium with 300 (370) mg iodine/ml. Intravenous injection protocols were adapted for an identical iodine delivery rate (1.3mg/s) and body surface area (BSA) adapted iodine dose (22.26 gI/m(2)). Maximum and mean standardized uptake values (SUV(max); SUV(mean)) and contrast enhancement (HU) were determined in the ascending aorta, the abdominal aorta, the inferior vena cava, the portal vein, the liver and the right kidney in the venous contrast medium phase. PET data were evaluated visually for the presence of malignancy and image quality. RESULTS: Both media caused significantly higher values for HU, SUV(mean) and SUV(max) for the enhanced PET/CT than the non-enhanced one (all p<0.01). There were no significant differences in the degree of increase of HU, SUV(mean) and SUV(max) between the two contrast media at any anatomic site (all p>0.05). Visual evaluation of lesions showed no differences between contrast and non-contrast PET/CT or between the two different contrast media (p=0.77). CONCLUSION: When using a constant iodine delivery rate and total iodine dose in a BSA adapted injection protocol, there are no quantitative or qualitative differences in either CT or PET between contrast media with an iodine concentration of 300 mg/ml and 370 mg/ml, respectively.


Assuntos
Superfície Corporal , Iohexol/análogos & derivados , Imagem Multimodal/métodos , Neoplasias/diagnóstico , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Meios de Contraste/administração & dosagem , Relação Dose-Resposta a Droga , Feminino , Humanos , Aumento da Imagem/métodos , Injeções Intravenosas , Iohexol/administração & dosagem , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
Virchows Arch ; 461(2): 211-9, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22729140

RESUMO

For the past century, autopsy techniques in clinical pathology have not changed significantly, while autopsy rates are declining. Modern imaging techniques offer interesting prospects of supportive post-mortem diagnostic investigation. In a prospective study of 29 autopsy cases, complimentary virtual autopsy using unenhanced post-mortem computed tomography (pmCT) was performed. We analysed in a prospective cohort study 29 unenhanced pmCT scans, generated prior to autopsy. Clinical information regarding clinical history and circumstances of death were provided. The objective of the study was to find consistency and/or discrepancy between virtual autopsy and conventional autopsy findings regarding cause of death and death-related diagnoses, reconstruction of the pathogenetic mechanisms involved, side diagnoses and CPR (cardiopulmonary resuscitation)- or death-related post-mortem changes. Accuracy of pmCT for cause of death was 68 % and the positive predictive value (PPV) was 75 %. Regarding the pathogenetic mechanisms, accuracy of pmCT was 21 % and PPV was 29 %. The combined diagnostic yield of autopsy and pmCT was 133 % compared to autopsy only. Modern imaging techniques give an opportunity for post-mortem diagnostics to complete but not yet replace traditional autopsy. We could show that in two out of three cases, the cause of death found by pmCT matched the diagnosis from classical autopsy. While both disciplines, pathology and radiology, will profit from the mutual exchange of data, it seems a realistic aim to strive for virtual autopsy possibly further supported by biopsies and contrast-enhanced pmCT as an alternative to the classical clinical autopsy. A combination of both methods enhances diagnostic quality and completeness of the autopsy report.


Assuntos
Autopsia/métodos , Tomografia Computadorizada por Raios X , Interface Usuário-Computador , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Causas de Morte , Criança , Pré-Escolar , Estudos de Viabilidade , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Adulto Jovem
16.
Cardiovasc Intervent Radiol ; 33(2): 389-93, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19657692

RESUMO

We report the case of a man with an uncommon anomaly of the origin and course of the left coronary artery. Clinical, coronary angiography, magnetic resonance imaging, and multislice computed tomography findings of this intermittently symptomatic 49 year-old patient with the rare anomaly of his left coronary artery stemming from the right sinus of Valsalva and taking an interarterial and intraseptal course are presented. The diagnostic value of the different imaging modalities is discussed.


Assuntos
Anomalias dos Vasos Coronários/diagnóstico , Angiografia por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico , Intensificação de Imagem Radiográfica , Seio Aórtico/anormalidades , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Angiografia Coronária/métodos , Ponte de Artéria Coronária/métodos , Anomalias dos Vasos Coronários/complicações , Anomalias dos Vasos Coronários/cirurgia , Eletrocardiografia , Seguimentos , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/cirurgia , Doenças Raras , Medição de Risco , Índice de Gravidade de Doença , Seio Aórtico/diagnóstico por imagem , Resultado do Tratamento
17.
Ann Surg ; 248(2): 205-11, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18650629

RESUMO

OBJECTIVE: The term "informed consent" explains the process by which a patient, before treatment, is provided comprehensive and impartial information regarding a planned operative procedure so that he/she understands the implications of the procedure before consenting. The goal of the current study was to investigate whether standard methods of consenting can be improved using a multimedia-based information program (MM-IP). PATIENTS AND METHODS: In a prospective multicenter study, 80 patients undergoing laparoscopic cholecystectomy went through the standard informed consent process. One group of patients was also given access to a MM-IP. Questionnaires were completed before surgery. These evaluated how patients perceived their own understanding of important aspects of their illness (ie, disease, therapeutic alternatives, operation, risks) and satisfaction with the consenting process. Patients' anxiety levels were also assessed. These questionnaires were used to evaluate the effectiveness of the MM-IP for improving the consent process. RESULTS: Seventy-six patients (47 women, 29 men, median age 54 years) were included. There was no significant age or gender variation between the groups (standard n = 41 and MM-IP n = 35). Eighty-two percent of all respondents were satisfied with the standard informed consent process. However, perceived understanding of the material was significantly improved in the MM-IP group (P < 0.001). Patients with less formal education profited particularly from the MM-IP. Preoperative anxiety did not vary between the groups. CONCLUSION: Use of the multimedia-based program was positively evaluated by patients, and significantly improved patients' perceived understanding of their disease and its treatment. It is, therefore, valuable in the informed consent process.


Assuntos
Colecistectomia/métodos , Consentimento Livre e Esclarecido/normas , Multimídia , Educação de Pacientes como Assunto/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Colecistectomia/efeitos adversos , Comunicação , Barreiras de Comunicação , Compreensão , Procedimentos Cirúrgicos Eletivos , Feminino , Humanos , Masculino , Informática Médica/normas , Informática Médica/tendências , Pessoa de Meia-Idade , Satisfação do Paciente , Relações Médico-Paciente , Cuidados Pré-Operatórios , Probabilidade , Estudos Prospectivos , Valores de Referência , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...