Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int Dent J ; 58(5): 269-78, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19009994

RESUMO

OBJECTIVE: To quantify the amount of Total Volatile Organic Compounds (TVOCs) emitted from five dental substances commonly used in a dental clinic. METHOD: An assessment of the indoor air quality in two clinics of the Athens University Dentistry Faculty was conducted. RESULTS: It was found that TVOC emissions from Kalocryl and Bacillol reached extremely high values affecting the air in the dental clinics at short and long distances from the source. Six pollutants TVOCs, CO2, PM10, PM2.5, SO2 and NO(x) were measured and indoor sources associated with dental activities were identified. Very high concentrations of TVOCs were found which exceeded the acceptable levels by a factor of 20, associated with the nature of the dental activities and the ventilation conditions. The CO2 concentration levels were high and the indoor conditions were considered unsatisfactory, associated with the number of occupants and the ventilation conditions. PM concentrations were high due to the nature of the dental activities and they exceeded the outdoor levels by a factor of 5 to 6. The concentrations of the gaseous pollutants NO(x) were low while the SO2 concentrations were hardly detectable.


Assuntos
Poluição do Ar em Ambientes Fechados/análise , Clínicas Odontológicas , Compostos Orgânicos Voláteis/análise , Dióxido de Carbono/análise , Materiais Dentários/química , Grécia , Humanos , Óxido Nitroso/análise , Material Particulado/análise , Dióxido de Enxofre/análise , Ventilação
2.
Sci Total Environ ; 377(2-3): 349-65, 2007 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-17434576

RESUMO

The purpose of this work is to assess, both experimentally and theoretically the status of air quality in a dentistry clinic of the Athens University Dentistry Faculty with respect to chemical pollutants and identify the indoor sources associated with dental activities. Total VOCs, CO(2), PM(10), PM(2.5), NO(x) and SO(2) were measured over a period of approximately three months in a selected dentistry clinic. High pollution levels during the operation hours regarding CO(2), total VOCs and Particulate Matter were found, while in the non-working periods lower levels were recorded. On the contrary, NO(x) and SO(2) remained at low levels for the whole experimental period. These conditions were associated with the number of occupants, the nature of the dental clinical procedures, the materials used and the ventilation schemes, which lead to high concentrations, far above the limits that are set by international organizations and concern human exposure. The indoor environmental conditions were investigated using the Computational Fluid Dynamics (CFD) model PHOENICS for inert gases simulation. The results revealed diagonal temperature stratification and low air velocities leading to pollution stratification, accompanied by accumulation of inert gaseous species in certain areas of the room. Different schemes of natural ventilation were also applied in order to examine their effect on the indoor comfort conditions for the occupants, in terms of air renewal and double cross ventilation was found to be most effective. The relative contribution of the indoor sources, which are mainly associated with indoor activities, was assessed by application of the Multi Chamber Indoor Air Quality Model (MIAQ) to the experimental data. It was found that deposition onto indoor surfaces is an important removal mechanism while a great amount of particulate matter emitted in the Clinic burdened severely the indoor air quality. The natural ventilation of the room seemed to reduce the levels of the fine particles. The emission rates for the fine and coarse particulates were found to be almost equal, while the coarse particles were found susceptible to deposition onto indoor surfaces.


Assuntos
Poluentes Atmosféricos/análise , Poluição do Ar em Ambientes Fechados/análise , Clínicas Odontológicas , Dióxido de Carbono/análise , Monitoramento Ambiental , Grécia , Modelos Teóricos , Óxidos de Nitrogênio/análise , Compostos Orgânicos/análise , Material Particulado/análise , Dióxido de Enxofre/análise , Ventilação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...