Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(6)2023 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-36991665

RESUMO

In this article, the performance of n-type junctionless (JL) double-gate (DG) MOSFET-based biosensors with and without gate stack (GS) has been studied. Here, the dielectric modulation (DM) method is applied to detect biomolecules in the cavity. The sensitivity of n-type JL-DM-DG-MOSFET and n-type JL-DM-GSDG-MOSFET-based biosensors have also been evaluated. The sensitivity (ΔVth) improved in JL-DM-GSDG MOSFET/JL-DM-DG-MOSFET-based biosensors for neutral/charged biomolecules is 116.66%/66.66% and 1165.78%/978.94%, respectively, compared with the previously reported results. The electrical detection of biomolecules is validated using the ATLAS device simulator. The noise and analog/RF parameters are compared between both biosensors. A lower threshold voltage is observed in the GSDG-MOSFET-based biosensor. The Ion/Ioff ratio is higher for DG-MOSFET-based biosensors. The proposed GSDG-MOSFET-based biosensor demonstrates higher sensitivity than the DG-MOSFET-based biosensor. The GSDG-MOSFET-based biosensor is suitable for low-power, high-speed, and high sensitivity applications.


Assuntos
Técnicas Biossensoriais , Transistores Eletrônicos , Semicondutores , Técnicas Biossensoriais/métodos , Eletricidade
2.
Biosensors (Basel) ; 12(10)2022 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-36290965

RESUMO

Microstrip patch antennas have been used in many applications since their appearance. Despite their great promise, their narrow bandwidth and the loss at high-frequency bands have limited their usage in medical applications. This work proposes a developed low-cost microstrip patch antenna suitable for microwave imaging (MWI) applications within the wideband frequency range. The proposed antenna is loaded with an artificial magnetic conductor (AMC) to improve the antenna performance. The simulated results obtained using computer simulation technology (CST) indicate that the presence of the AMC has improved the frequency selectivity of the antenna at 8.6 GHz with a peak realized gain of 9.90443 dBi and 10.61 dBi for simulated and measured results, respectively. The proposed microstrip antenna has been fabricated to validate the simulated results, and its performance is tested experimentally. Additionally, the fidelity factor of face-to-face (FtF) and side-by-side (SbS) scenarios have been presented. The breast phantom models with a tumor and the antenna operating as a transceiver have been numerically simulated for the application of cancer tumor cell detection. The work will have a significant impact on the design of electromagnetic biosensors.


Assuntos
Neoplasias da Mama , Corpo Humano , Humanos , Feminino , Simulação por Computador , Desenho de Equipamento , Mama , Neoplasias da Mama/diagnóstico
3.
ACS Omega ; 7(42): 38094-38104, 2022 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-36312388

RESUMO

In this paper, a terahertz (THz) metamaterial absorber (MTMA), incorporating surface Pythagorean tree fractal resonators, was designed and experimentally fabricated on the flexible substrate of polyethylene terephthalate. The design presented two peaks with strong absorption of more than 97% at 0.49 and 0.69 THz. The dual-band absorption peaks were seen to be shifted with the change in the refractive index of the surrounding medium, with a corresponding sensitivity of 0.0968 and 0.1182 THz/RIU. The spectral shift of the reflection resonance dip was utilized as an assessment index to evaluate the sensing performance of the new structure, and it was found to be 2.08 and 2.98 for the two resonance peaks, respectively. It was observed that the proposed structure acted as an epsilon negative material at the first resonance and as a mu negative material at the second resonance. Further investigations on the electric field, magnetic field, and surface current distributions were carried out to elaborate on the absorption characteristics at various resonance frequencies. The proposed sensor is a highly sensitive MTMA which can be used to investigate the interaction of matter with THz waves.

4.
Materials (Basel) ; 15(18)2022 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-36143675

RESUMO

A new design of a triple band perfect metamaterial absorber based on Pythagorean fractal geometry is proposed and analyzed for terahertz sensing applications. The proposed design showed an enhanced sensing performance and achieved three intensive peaks at 33.93, 36.27, and 38.39 THz, corresponding to the absorptivity of 98.5%, 99.3%, and 99.6%, respectively. Due to the symmetrical nature of the recommended design, the structure exhibited the characteristics of independency on the incident wave angles. Furthermore, a parametric study was performed to show the effects of the change in substrate type, resonator material, and substrate thickness on the absorption spectrum. At a fixed analyte thickness (0.5 µm), the resonance frequency of the design was found to be sensitive to the refractive index of the surrounding medium. The proposed design presented three ultra-sensitive responses of 1730, 1590, and 2050 GHz/RIU with the figure of merit (FoM) of 3.20, 1.54, and 4.28, respectively, when the refractive index was changed from 1.0 to 1.4. Additionally, the metamaterial sensor showed a sensitivity of 1230, 2270, and 1580 GHz/µm at the three resonance frequencies, respectively, when it was utilized for the detection of thickness variation at a fixed analyte refractive index (RI) of 1.4. As long as the RI of the biomedical samples is between 1.3 and 1.4, the proposed sensor can be used for biomedical applications.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA