Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Analyst ; 141(2): 652-60, 2016 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-26549051

RESUMO

Early detection of initial onset, as well as recurrence, of cancer is paramount for improved patient prognosis and human health. Cancer screening is enhanced by rapid differentiation of cancerous from non-cancerous cells which employs the inherent differences in biophysical properties. Our preliminary testing demonstrates that cell-line derived bladder cancer cells deform our <30 nm silicone membrane within an hour and induce visually distinct wrinkle patterns while cell-line derived non-cancerous cells fail to induce these wrinkle patterns. Herein, we report a platform for the rapid detection of cancerous cells from human clinical urine samples. We performed a blinded study with cells extracted from the urine of human patients suspected to have bladder cancer alongside healthy controls. Wrinkle patterns were induced specifically by the five cancer patient samples within 12 hours and not by the healthy controls. These results were independently validated by the standard diagnostic techniques cystoscopy and cytology. Thus, our ultra-thin membrane approach for cancer diagnosis appears as accurate as standard diagnostic methods while vastly more rapid, less invasive, and requiring limited expertise.


Assuntos
Separação Celular/métodos , Membranas Artificiais , Silicones/química , Neoplasias da Bexiga Urinária/patologia , Linhagem Celular Tumoral , Humanos , Fatores de Tempo , Neoplasias da Bexiga Urinária/urina
2.
ACS Biomater Sci Eng ; 2(3): 361-367, 2016 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-33429540

RESUMO

Atomically thin transition-metal dichalcogenides (TMDs) have attracted considerable interest because of their unique combination of properties, including photoluminescence, high lubricity, flexibility, and catalytic activity. These unique properties suggest future uses for TMDs in medical applications such as orthodontics, endoscopy, and optogenetics. However, few studies thus far have investigated the biocompatibility of mechanically exfoliated and chemical vapor deposition (CVD)-grown pristine two-dimensional TMDs. Here, we evaluate pristine molybdenum disulfide (MoS2) and tungsten disulfide (WS2) in a series of biocompatibility tests, including live-dead cell assays, reactive oxygen species (ROS) generation assays, and direct assessment of cellular morphology of TMD-exposed human epithelial kidney cells (HEK293f). Genotoxicity and genetic mutagenesis were also evaluated for these materials via the Ames Fluctuation test with the bacterial strain S. typhimurium TA100. Scanning electron microscopy of cultured HEK293f cells in direct contact with MoS2 and WS2 showed no impact on cell morphology. HEK293f cell viability, evaluated by both live-dead fluorescence labeling to detect acute toxicity and ROS to monitor for apoptosis, was unaffected by these materials. Exposure of bacterial cells to these TMDs failed to generate genetic mutation. Together, these findings demonstrate that neither mechanically exfoliated nor CVD-grown TMDs are deleterious to cellular viability or induce genetic defects. Thus, these TMDs appear biocompatible for future application in medical devices.

3.
Ann Biomed Eng ; 43(3): 603-15, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25737163

RESUMO

Reliable cerebrospinal fluid (CSF) draining methods are needed to treat hydrocephalus, a chronic debilitating brain disorder. Current shunt implant treatments are characterized by high failure rates that are to some extent attributed to their length and multiple components. The designed valve, made of hydrogel, steers away from such protracted schemes and intends to provide a direct substitute for faulty arachnoid granulations, the brain's natural CSF draining valves, and restore CSF draining operations within the cranium. The valve relies on innate hydrogel swelling phenomena to strengthen reverse flow sealing at idle and negative pressures thereby alleviating common valve failure mechanisms. In vitro measurements display operation in range of natural CSF draining (cracking pressure, PT ~ 1-110 mmH2O and outflow hydraulic resistance, Rh ~ 24-152 mmH2O/mL/min), with negligible reverse flow leakage (flow, QO > -10 µL/min). Hydrodynamic measurements and over-time tests under physically relevant conditions further demonstrate the valve's operationally-reproducible properties and strengthen its validity for use as a chronic implant.


Assuntos
Hidrocefalia/terapia , Hidrogéis/uso terapêutico , Miniaturização/instrumentação , Líquido Cefalorraquidiano , Desenho de Equipamento , Humanos , Hidrodinâmica , Pressão Intracraniana
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...