Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-30882044

RESUMO

Peripheral nerves are often vulnerable to damage during surgeries, with risks of significant pain, loss of motor function, and reduced quality of life for the patient. Intraoperative methods for monitoring nerve activity are effective, but conventional systems rely on bench-top data acquisition tools with hard-wired connections to electrode leads that must be placed percutaneously inside target muscle tissue. These approaches are time and skill intensive and therefore costly to an extent that precludes their use in many important scenarios. Here we report a soft, skin-mounted monitoring system that measures, stores, and wirelessly transmits electrical signals and physical movement associated with muscle activity, continuously and in real-time during neurosurgical procedures on the peripheral, spinal, and cranial nerves. Surface electromyography and motion measurements can be performed non-invasively in this manner on nearly any muscle location, thereby offering many important advantages in usability and cost, with signal fidelity that matches that of the current clinical standard of care for decision making. These results could significantly improve accessibility of intraoperative monitoring across a broad range of neurosurgical procedures, with associated enhancements in patient outcomes.

2.
Digit Biomark ; 1(1): 52-63, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-32095745

RESUMO

BACKGROUND: Clinician rating scales and patient-reported outcomes are the principal means of assessing motor symptoms in Parkinson disease and Huntington disease. However, these assessments are subjective and generally limited to episodic in-person visits. Wearable sensors can objectively and continuously measure motor features and could be valuable in clinical research and care. METHODS: We recruited participants with Parkinson disease, Huntington disease, and prodromal Huntington disease (individuals who carry the genetic marker but do not yet exhibit symptoms of the disease), and controls to wear 5 accelerometer-based sensors on their chest and limbs for standardized in-clinic assessments and for 2 days at home. The study's aims were to assess the feasibility of use of wearable sensors, to determine the activity (lying, sitting, standing, walking) of participants, and to survey participants on their experience. RESULTS: Fifty-six individuals (16 with Parkinson disease, 15 with Huntington disease, 5 with prodromal Huntington disease, and 20 controls) were enrolled in the study. Data were successfully obtained from 99.3% (278/280) of sensors dispatched. On average, individuals with Huntington disease spent over 50% of the total time lying down, substantially more than individuals with prodromal Huntington disease (33%, p = 0.003), Parkinson disease (38%, p = 0.01), and controls (34%; p < 0.001). Most (86%) participants were "willing" or "very willing" to wear the sensors again. CONCLUSIONS: Among individuals with movement disorders, the use of wearable sensors in clinic and at home was feasible and well-received. These sensors can identify statistically significant differences in activity profiles between individuals with movement disorders and those without. In addition, continuous, objective monitoring can reveal disease characteristics not observed in clinic.

3.
Biosens Bioelectron ; 78: 290-299, 2016 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-26630284

RESUMO

In developing countries, the deployment of medical diagnostic technologies remains a challenge because of infrastructural limitations (e.g. refrigeration, electricity), and paucity of health professionals, distribution centers and transportation systems. Here we demonstrate the technical development and clinical testing of a novel electronics enabled microfluidic paper-based analytical device (EE-µPAD) for quantitative measurement of micronutrient concentrations in decentralized, resource-limited settings. The system performs immune-detection using paper-based microfluidics, instrumented with flexible electronics and optoelectronic sensors in a mechanically robust, ultrathin format comparable in size to a credit card. Autonomous self-calibration, plasma separation, flow monitoring, timing and data storage enable multiple devices to be run simultaneously. Measurements are wirelessly transferred to a mobile phone application that geo-tags the data and transmits it to a remote server for real time tracking of micronutrient deficiencies. Clinical tests of micronutrient levels from whole blood samples (n=95) show comparable sensitivity and specificity to ELISA-based tests. These results demonstrate instantaneous acquisition and global aggregation of diagnostics data using a fully integrated point of care system that will enable rapid and distributed surveillance of disease prevalence and geographical progression.


Assuntos
Técnicas Biossensoriais , Técnicas Analíticas Microfluídicas/métodos , Micronutrientes/sangue , Telefone Celular , Ensaio de Imunoadsorção Enzimática , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Sensibilidade e Especificidade
4.
Annu Int Conf IEEE Eng Med Biol Soc ; 2016: 5298-5302, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28269456

RESUMO

Sufficient range of motion of the knee joint is necessary for performing many activities of daily living. Ambulatory monitoring of knee function can provide valuable information about progression of diseases like knee osteoarthritis and recovery after surgical interventions like total knee arthroplasty. In this paper, we describe a skin-mounted, conformal, accelerometer-based system for measuring knee angle and range of motion that does not require a skilled operator to apply devices. We establish the accuracy of this technique with respect to clinical gold standard goniometric measurements on a dataset collected from normative subjects during the performance of repeated bouts of knee flexion and extension tests. Results show that knee angle and range of motion estimates are highly correlated with goniometer measurements, and track differences in knee angle and range of motion to within 1%. These results demonstrate the ability of this system to characterize knee angle and range of motion, enabling future longitudinal monitoring of knee motion in naturalistic environments.


Assuntos
Acelerometria/instrumentação , Joelho/fisiologia , Monitorização Ambulatorial/instrumentação , Monitorização Ambulatorial/métodos , Amplitude de Movimento Articular/fisiologia , Humanos
5.
Annu Int Conf IEEE Eng Med Biol Soc ; 2016: 5997-6001, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28269619

RESUMO

Wearable sensors have the potential to enable clinical-grade ambulatory health monitoring outside the clinic. Technological advances have enabled development of devices that can measure vital signs with great precision and significant progress has been made towards extracting clinically meaningful information from these devices in research studies. However, translating measurement accuracies achieved in the controlled settings such as the lab and clinic to unconstrained environments such as the home remains a challenge. In this paper, we present a novel wearable computing platform for unobtrusive collection of labeled datasets and a new paradigm for continuous development, deployment and evaluation of machine learning models to ensure robust model performance as we transition from the lab to home. Using this system, we train activity classification models across two studies and track changes in model performance as we go from constrained to unconstrained settings.


Assuntos
Computação em Nuvem , Aprendizado de Máquina , Modelos Teóricos , Monitorização Ambulatorial/instrumentação , Monitorização Ambulatorial/métodos , Atividades Cotidianas , Adulto , Feminino , Humanos , Masculino
6.
Biophys J ; 99(10): 3274-81, 2010 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-21081075

RESUMO

The solid component of the tectorial membrane (TM) is a porous matrix made up of the radial collagen fibers and the striated sheet matrix. The striated sheet matrix is believed to contribute to shear impedance in both the radial and longitudinal directions, but the molecular mechanisms involved have not been determined. A missense mutation in Tecta, a gene that encodes for the α-tectorin protein in the striated sheet matrix, causes a 60-dB threshold shift in mice with relatively little reduction in outer hair cell amplification. Here, we show that this threshold shift is coupled to changes in shear impedance, response to osmotic pressure, and concentration of fixed charge of the TM. In Tecta(Y)(1870C/+) mice, the tectorin content of the TM was reduced, as was the content of glycoconjugates reacting with the lectin wheat germ agglutinin. Charge measurements showed a decrease in fixed charge concentration from -6.4±1.4 mmol/L in wild-types to -2.1±0.7 mmol/L in Tecta(Y)(1870C/+) TMs. TMs from Tecta(Y)(1870C/+) mice showed little volume change in response to osmotic pressure compared to those of wild-type mice. The magnitude of both radial and longitudinal TM shear impedance was reduced by 10±1.6 dB in Tecta(Y)(1870C/+) mice. However, the phase of shear impedance was unchanged. These changes are consistent with an increase in the porosity of the TM and a corresponding decrease of the solid fraction. Mechanisms by which these changes can affect the coupling between outer and inner hair cells are discussed.


Assuntos
Proteínas da Matriz Extracelular/metabolismo , Heterozigoto , Membrana Tectorial/metabolismo , Animais , Impedância Elétrica , Proteínas Ligadas por GPI/metabolismo , Potenciais da Membrana/efeitos dos fármacos , Potenciais da Membrana/fisiologia , Camundongos , Peso Molecular , Pressão Osmótica/efeitos dos fármacos , Polietilenoglicóis/química , Polietilenoglicóis/farmacologia , Resistência ao Cisalhamento , Membrana Tectorial/citologia , Membrana Tectorial/efeitos dos fármacos
7.
Biophys J ; 96(11): 4717-24, 2009 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-19486694

RESUMO

The tectorial membrane (TM) has a significantly larger stiffness in the radial direction than other directions, a prominent mechanical anisotropy that is believed to be critical for the proper functioning of the cochlea. To determine the molecular basis of this anisotropy, we measured material properties of TMs from mice with a targeted deletion of Col11a2, which encodes for collagen XI. In light micrographs, the density of TM radial collagen fibers was lower in Col11a2 -/- mice than wild-types. Tone-evoked distortion product otoacoustic emission and auditory brainstem response measurements in Col11a2 -/- mice were reduced by 30-50 dB independent of frequency as compared with wild-types, showing that the sensitivity loss is cochlear in origin. Stress-strain measurements made using osmotic pressure revealed no significant dependence of TM bulk compressibility on the presence of collagen XI. Charge measurements made by placing the TM as an electrical conduit between two baths revealed no change in the density of charge affixed to the TM matrix in Col11a2 -/- mice. Measurements of mechanical shear impedance revealed a 5.5 +/- 0.8 dB decrease in radial shear impedance and a 3.3 +/- 0.3 dB decrease in longitudinal shear impedance resulting from the Col11a2 deletion. The ratio of radial to longitudinal shear impedance fell from 1.8 +/- 0.7 for TMs from wild-type mice to 1.0 +/- 0.1 for those from Col11a2 -/- mice. These results show that the organization of collagen into radial fibrils is responsible for the mechanical anisotropy of the TM. This anisotropy can be attributed to increased mechanical coupling provided by the collagen fibrils. Mechanisms by which changes in TM material properties may contribute to the threshold elevation in Col11a2 -/- mice are discussed.


Assuntos
Colágeno Tipo XI/genética , Colágeno/fisiologia , Membrana Tectorial/fisiologia , Animais , Anisotropia , Limiar Auditivo/fisiologia , Cóclea/fisiologia , Colágeno/genética , Elasticidade , Potenciais Evocados Auditivos do Tronco Encefálico/genética , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Deleção de Genes , Camundongos , Camundongos Knockout , Microeletrodos , Estresse Mecânico
8.
Biophys J ; 95(5): 2529-38, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18515382

RESUMO

Microscale mechanical probes were designed and bulk-fabricated for applying shearing forces to biological tissues. These probes were used to measure shear impedance of the tectorial membrane (TM) in two dimensions. Forces were applied in the radial and longitudinal directions at frequencies ranging from 0.01-9 kHz and amplitudes from 0.02-4 microN. The force applied was determined by measuring the deflection of the probes' cantilever arms. TM impedance in the radial direction had a magnitude of 63 +/- 28 mN x s/m at 10 Hz and fell with frequency by 16 +/- 0.4 dB/decade, with a constant phase of -72 +/- 6 degrees . In the longitudinal direction, impedance was 36 +/- 9 mN x s/m at 10 Hz and fell by 19 +/- 0.4 dB/decade, with a constant phase of -78 +/- 4 degrees . Impedance was nearly constant as a function of force except at the highest forces, for which it fell slightly. These results show that the viscoelastic properties of the TM extend over a significant range of audio frequencies, consistent with a poroelastic interpretation of TM mechanics. The shear modulus G' determined from these measurements was 17-50 kPa, which is larger than in species with a lower auditory frequency range. This value suggests that hair bundles cannot globally shear the TM, but most likely cause bulk TM motion.


Assuntos
Modelos Biológicos , Membrana Tectorial/fisiologia , Animais , Elasticidade , Impedância Elétrica , Masculino , Camundongos , Microscopia de Vídeo , Resistência ao Cisalhamento , Estresse Mecânico , Vibração , Viscosidade
9.
J Acoust Soc Am ; 118(3 Pt 1): 1585-92, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16240819

RESUMO

Measurements of motion of an in vitro preparation of the alligator lizard basilar papilla in response to sound demonstrate elliptical trajectories. These trajectories are consistent with the presence of both a translational and rotational mode of motion. The translational mode is independent of frequency, and the rotational mode has a displacement peak near 5 kHz. These measurements can be explained by a simple mechanical system in which the basilar papilla is supported asymmetrically on the basilar membrane. In a quantitative model, the translational admittance is compliant while the rotational admittance is second order. Best-fit model parameters are consistent with estimates based on anatomy and predict that fluid flow across hair bundles is a primary source of viscous damping. The model predicts that the rotational mode contributes to the high-frequency slopes of auditory nerve fiber tuning curves, providing a physical explanation for a low-pass filter required in models of this cochlea. The combination of modes makes the sensitivity of hair bundles more uniform with radial position than that which would result from pure rotation. A mechanical analogy with the organ of Corti suggests that these two modes of motion may also be present in the mammalian cochlea.


Assuntos
Membrana Basilar/fisiologia , Cóclea/fisiologia , Lagartos/fisiologia , Movimento/fisiologia , Animais , Membrana Basilar/anatomia & histologia , Células Ciliadas Auditivas/fisiologia , Modelos Biológicos
10.
Biophys J ; 87(5): 3536-46, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15315953

RESUMO

We present motions of individual freestanding hair bundles in an isolated cochlea in response to tonal sound stimulation. Motions were measured from images taken by strobing a light source at the tone frequency. The tips and bases of hair bundles moved a comparable amount, but with a phase difference that increased by 180 degrees with frequency, indicating that distributed fluid properties drove hair bundle motion. Hair bundle rotation increased with frequency to a constant value, and underwent >90 degrees of phase change. The frequency at which the phase of rotation relative to deflection of the bundle base was 60 degrees was comparable to the expected best frequency of each hair cell, and varied inversely with the square of bundle height. The sharpness of tuning of individual hair bundles was comparable to that of hair cell receptor potentials at high sound levels. These results indicate that frequency selectivity at high sound levels in this cochlea is purely mechanical, determined by the interaction of hair bundles with the surrounding fluid. The sharper tuning of receptor potentials at lower sound levels is consistent with the presence of a negative damping, but not a negative stiffness, as an active amplifier in hair bundles.


Assuntos
Estimulação Acústica/métodos , Células Ciliadas Auditivas Internas/citologia , Células Ciliadas Auditivas Internas/fisiologia , Mecanotransdução Celular/fisiologia , Movimento/fisiologia , Espectrografia do Som/métodos , Animais , Células Cultivadas , Cóclea/citologia , Cóclea/fisiologia , Interpretação de Imagem Assistida por Computador/métodos , Lagartos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...