Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Quant Imaging Med Surg ; 11(4): 1470-1482, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33816183

RESUMO

BACKGROUND: Left ventricular (LV) kinetic energy (KE) assessment by four-dimensional flow cardiovascular magnetic resonance (4D flow CMR) may offer incremental value over routine assessment in aortic stenosis (AS). The main objective of this study is to investigate the LV KE in patients with AS before and after the valve intervention. In addition, this study aimed to investigate if LV KE offers incremental value for its association to the six-minute walk test (6MWT) or LV remodelling post-intervention. METHODS: We recruited 18 patients with severe AS. All patients underwent transthoracic echocardiography for mean pressure gradient (mPG), CMR including 4D flow and 6MWT. Patients were invited for post-valve intervention follow-up CMR at 3 months and twelve patients returned for follow-up CMR. KE assessment of LV blood flow and the components (direct, delayed, retained and residual) were carried out for all cases. LV KE parameters were normalised to LV end-diastolic volume (LVEDV). RESULTS: For LV blood flow KE assessment, the metrics including time delay (TD) for peak E-wave from base to mid-ventricle (14±48 vs. 2.5±9.75 ms, P=0.04), direct (4.91±5.07 vs. 1.86±1.72 µJ, P=0.01) and delayed (2.46±3.13 vs. 1.38±1.15 µJ, P=0.03) components of LV blood flow demonstrated a significant change between pre- and post-valve intervention. Only LV KEiEDV (r=-0.53, P<0.01), diastolic KEiEDV (r=-0.53, P<0.01) and Ewave KEiEDV (r=-0.38, P=0.04) demonstrated association to the 6MWT. However, Pre-operative LV KEiEDV (r=0.67, P=0.02) demonstrated association to LV remodelling post valve intervention. CONCLUSIONS: LV blood flow KE is associated with 6MWT and LV remodelling in patients with AS. LV KE assessment provides incremental value over routine LV function and pressure gradient (PG) assessment in AS.

2.
Sci Rep ; 10(1): 10569, 2020 06 29.
Artigo em Inglês | MEDLINE | ID: mdl-32601326

RESUMO

The management of patients with aortic stenosis (AS) crucially depends on accurate diagnosis. The main aim of this study were to validate the four-dimensional flow (4D flow) cardiovascular magnetic resonance (CMR) methods for AS assessment. Eighteen patients with clinically severe AS were recruited. All patients had pre-valve intervention 6MWT, echocardiography and CMR with 4D flow. Of these, ten patients had a surgical valve replacement, and eight patients had successful transcatheter aortic valve implantation (TAVI). TAVI patients had invasive pressure gradient assessments. A repeat assessment was performed at 3-4 months to assess the remodelling response. The peak pressure gradient by 4D flow was comparable to an invasive pressure gradient (54 ± 26 mmHG vs 50 ± 34 mmHg, P = 0.67). However, Doppler yielded significantly higher pressure gradient compared to invasive assessment (61 ± 32 mmHG vs 50 ± 34 mmHg, P = 0.0002). 6MWT was associated with 4D flow CMR derived pressure gradient (r = -0.45, P = 0.01) and EOA (r = 0.54, P < 0.01) but only with Doppler EOA (r = 0.45, P = 0.01). Left ventricular mass regression was better associated with 4D flow derived pressure gradient change (r = 0.64, P = 0.04). 4D flow CMR offers an alternative method for non-invasive assessment of AS. In addition, 4D flow derived valve metrics have a superior association to prognostically relevant 6MWT and LV mass regression than echocardiography.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Sistema Cardiovascular/fisiopatologia , Ecocardiografia/métodos , Ecocardiografia Doppler/métodos , Feminino , Tomografia Computadorizada Quadridimensional , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Volume Sistólico/fisiologia , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA