Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Odovtos (En línea) ; 26(1): 21-34, Jan.-Apr. 2024. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1558616

RESUMO

Abstract Ectodermal dysplasia (ED) is a genetic disorder affecting anatomical structures with an ectodermal origin. The consequent alveolar bone anomalies and lack of teeth require a multidisciplinary approach to rehabilitate patients function and esthetics. To avoid bone grafting procedures the application of zygomatic implants was suggested for the upper jaw treatment. The advancements in three-dimensional (3D) radiology and the introduction of digital implant planning software could enhance the approach to zygomatic implants in ED patients. The present case report describes the quad zygomatic implant treatment of the edentulous maxilla of an ED patient by means of computer guided implant surgery. The patient reported previous failure of bone grafting procedures in the upper jaw. The implants were immediately loaded with a screw-retained complete-arch resin prosthesis. The patient was followed up for 1 year with no biological nor mechanical complications reported, but a slight bone resorption in the anterior zone was observed. Zygomatic implants could be a potential alternative treatment to bone grafting in upper jaw and the digital implant planning could enhance the surgical procedure.


Resumen La displasia ectodérmica (DE) es una enfermedad genética que afecta las estructuras anatómicas de origen ectodérmico. Las consiguientes anomalías del hueso alveolar y la anodoncia requieren un planteamiento multidisciplinario para rehabilitar la función y la estética de los pacientes. Para evitar procedimientos de injerto óseo se sugirió la aplicación de implantes cigomáticos para el tratamiento del maxilar superior. Los avances en radiología tridimensional (3D) y la introducción de software de planificación de implantes digitales podrían mejorar el enfoque de los implantes cigomáticos en los pacientes con displasia ectodérmica. El presente reporte de caso describe el tratamiento con implantes cigomáticos en el maxilar superior edéntulo de un paciente con displasia ectodérmica mediante cirugía de implantes guiada por ordenador. El paciente refirió fracaso de procedimientos de injerto óseo en el maxilar superior. Los implantes se cargaron inmediatamente con una prótesis de resina de arcada completa. El paciente ha sido incluido en un programa de control postoperatorio por 1 año, sin reportarse complicaciones ni biológicas ni mecánicas, siendo el único problema encontrado una ligera reabsorción ósea en la zona anterior. Los implantes cigomáticos podrían ser un posible tratamiento alternativo al injerto óseo en el maxilar superior y la planificación de implantes digitales podría mejorar el procedimiento quirúrgico.

2.
J Prosthodont Res ; 68(1): 172-180, 2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-37574278

RESUMO

PURPOSE: To assess and compare the accuracies of intraoral scanners (IOS) and stereophotogrammetry (SPG) devices for complete-arch digital implant impressions. METHODS: A 4-analog model was digitized using a desk scanner to obtain a reference file. Thirty test scans were conducted using the investigated IOS device, while an additional 30 scans were performed using the SPG device. Using the best-fit algorithm, the resulting 60 test files were aligned with the reference file. Linear (ΔX, ΔY, and ΔZ-axis) and angular deviations (ΔANGLE) were evaluated. Three-dimensional (3D) deviation was calculated based on the Euclidean distance (ΔEUC). The analysis was stratified according to the scanning device and implant position. Fisher's F and t-tests were used to compare the variances and expected values of the two scanning systems. RESULTS: IOS expressed a higher 3D (ΔEUC) mean deviation than SPG (52.8 µm vs. 33.4 µm, P < 0.0001), with extreme measurements up to 181.9 µm. A significantly higher standard deviation (SD) was associated with IOS (37.1 µm vs. 17.7 µm, P < 0.0001). Considering angular deviations, the IOS showed slightly higher angular mean deviations (ΔANGLE) than the SPG (0.28° vs. 0.24°, P = 0.0022), with extreme measurements of up to 0.73°. The SPG SD values were significantly lower than the IOS SD values (0.14° vs. 0.04°, P < 0.0001). CONCLUSIONS: The SPG showed significantly higher 3D and angular accuracies for complete arch implant impressions, with consistent repeatability. IOS scanning revealed significantly higher extreme deviations exceeding the acceptable threshold value. Despite study limitations, SPG appears more feasible than IOS for complete-arch digital implant impressions.


Assuntos
Implantes Dentários , Imageamento Tridimensional , Técnica de Moldagem Odontológica , Modelos Dentários , Desenho Assistido por Computador
3.
Healthcare (Basel) ; 11(21)2023 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-37958030

RESUMO

Introduction: Health professionals and bodyworkers may be pivotal in promoting prevention programs, providing tailored advice and guidance to patients' adherence to self-care strategies, such as physical activity. Contemporary evidence encourages manual therapists to involve patients in decision-making and treatment procedures integrating passive and active approaches in treatment planning. This manuscript provides a definition and applications of neuromyofascial movement patterns, discusses the significance of functional assessment, and gives an example of clinical applications in the osteopathic field to highlight how this assessment can promote interdisciplinarity. Methods: The reporting framework used in the current manuscript followed guidelines for writing a commentary. Results: The manuscript highlights the crucial role that the neuromyofascial system plays in human movement and overall well-being and the importance of a functional neuromyofascial activity assessment in the context of person-centered participative care. Conclusions: Understanding individual neuromyofascial patterns could help healthcare practitioners, movement specialists, and bodyworkers in tailoring treatment plans, meeting patients' unique needs, and promoting a more effective personalized approach to care. The current perspective could spark debates within the professional community and provide a research roadmap for developing an evidence-informed interprofessional framework.

4.
Clin Oral Implants Res ; 34(10): 1106-1117, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37485737

RESUMO

OBJECTIVES: To assess accuracy of intraoral optical scanning (IOS) and stereophotogrammetry (SPG), complete-arch digital implant impressions in vivo. MATERIALS AND METHODS: Consecutive patients needing implant-supported screw-retained zirconia complete-arch fixed-dental prostheses (ISZ-FDP) were recruited. For each patient, three impressions were taken: IOS, SPG (tests), and open-tray plaster (reference). Linear (ΔX, ΔY, and ΔZ), three-dimensional (ΔEUC), and angular deviations (ΔANGLE) were evaluated and stratified according to scanning technology for each implant. Potential effects of impression device (IOS and SPG), arch (maxilla and mandible), and implant number (4 and 6) were evaluated through multivariable analysis. Significance level was set at .05. RESULTS: A total of 11 complete arches (5 maxillae, 6 mandibles) in 11 patients were rehabilitated with ISZ-FDPs supported by 4 (n = 8) and 6 implants (n = 3). A total of 50 implants and 100 implant positions were captured by two investigated devices and compared to respective reference (mean ΔEUC IOS 137.2, SPG 87.6 µm; mean ΔANGLE 0.79, 0.38°). Differences between measurements (SPG-IOS) were computed for each implant, with negative values indicating better SPG accuracy. Significant mean ΔEUC difference of -49.60 µm (p = .0143; SD 138.15) and mean ΔANGLE difference of -0.40° (p < .0001; SD 0.65) were observed in favor of SPG. Multivariable analysis showed significant effect on ΔEUC (p = .0162) and ΔANGLE (p = .0001) only for impression devices, with SPG performing better. CONCLUSIONS: SPG experienced significantly higher linear and angular accuracy. No effect of type of arch or implant number was detected. Higher extreme deviations were experienced for IOS. SPG can be feasible for complete-arch digital impressions with caution, and rigid prototype try-in is recommended before screw-retained prosthesis manufacturing.

5.
J Prosthet Dent ; 129(1): 96-108, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34187699

RESUMO

STATEMENT OF PROBLEM: Despite the broad clinical application of zirconia for fixed implant-supported prostheses, evidence of long-term performance is sparse. PURPOSE: The purpose of this retrospective study was to evaluate the long-term clinical and radiographic outcomes of zirconia-based partial and complete screw-retained implant-supported zirconia fixed dental prostheses (ISZFDPs). MATERIAL AND METHODS: Records of patients treated with dental implants and ISZFDPs between December 2004 and June 2017 were screened. Eligible study participants, according to inclusion criteria, were contacted and invited to undergo clinical and radiographic examinations. Outcomes were evaluated as implant and prosthetic survival rates, prosthetic success rate, complications, marginal bone level (MBL) change, and soft tissue condition. Along with the effects of zirconia prosthesis type and level, the effects of implant type and connection, type of loading, and follow-up on MBL were tested with a generalized linear effects model (GLEM) (α=.05). RESULTS: A total of 118 patients were identified, of whom 20 (16.9%) were not available for clinical examination for various reasons. Ninety-eight participants (mean age 60.7 ±11.7 years) with 337 implants were included, of which 176 (52.2%) had been immediately loaded. A total of 111 ISZFDPs (96 zirconia connection and 15 titanium base) were investigated: 24 complete ISZFDPs with a zirconia connection (12.9 ±0.97 dental units, minimum 12, maximum 14), 72 partial with a zirconia connection (3.11 ±1.12, minimum 2, maximum 7), 15 partial with a titanium base (3.62 ±1.02, minimum 2, maximum 5). Forty ISZFDPs had been in function for ≥10 years (36%), 38 for 5 to 9 years (34.2%), and 33 for 2 to 4 years (22.8%). The mean follow-up time was 7.2 ±3.4 years. No zirconia fractures were identified. Two implants and 2 ISZFDPs failed, with chipping being the most common complication (13.5%). The implant survival rate was 99.4%, and the prosthetic survival rate was 98.2%. The cumulative prosthetic success rate was 91.9%. MBL change was -0.18 ±0.59 mm. Thirteen implants were treated for peri-implantitis (3.8%), and 9 for mucositis (2.7%), but presented healthy peri-implant soft tissues at the follow-up examination. A significant difference was found between the implant-level and abutment-level prostheses (P=.013), with less marginal bone loss observed in ISZFDPs delivered at the implant level. CONCLUSIONS: Zirconia-based screw-retained implant-supported prosthesis can be considered a reliable long-term treatment option for partial and complete edentulism. No zirconia fractures were experienced. Stable bone levels and low peri-implantitis rates were reported regardless of the ISZFDP type and level, implant type and connection, and type of loading.


Assuntos
Implantes Dentários , Peri-Implantite , Humanos , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Titânio , Falha de Restauração Dentária , Parafusos Ósseos , Prótese Dentária Fixada por Implante
6.
PLoS One ; 17(11): e0278041, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36441692

RESUMO

INTRODUCTION: Since the previous survey of the osteopathic profession in Austria was almost a decade ago, an update was necessary. The Osteopathic Practitioners Estimates and RAtes (OPERA) project was developed as a Europe-based survey, whereby an updated profile of the profession not only provides new data for Austria, but also allows for a clear comparison with other European countries. METHODS: A voluntary, online-based, closed-ended survey was distributed across Austria in the period between April and August 2020. The original English OPERA-questionnaire, composed of 52 questions in seven sections, was formally translated in German and adapted to the Austrian situation. Recruitment was performed through social-media and an e-based campaign. RESULTS: The survey was completed by 338 individuals, of which 239 (71%) were female, and the median age was 40-49 years. Almost all respondents had preliminary healthcare training, mainly in physiotherapy (72%). The majority of respondents were self-employed (88%) and working as sole practitioners (54%). The median number of consultations per week was 21-25 and the majority of respondents scheduled 46-60 minutes for each consultation (69%). The most commonly used diagnostic techniques were: palpation of position/structure, palpation of tenderness and visual inspection. The most commonly used treatment techniques were cranial, visceral and articulatory/mobilisation techniques. The majority of patients estimated by respondents consulted an osteopath for musculoskeletal complaints mainly localised in the lumbar and cervical region. Although the majority of respondents experience a strong osteopathic identity, only a small proportion (17%) advertise themselves exclusively as osteopaths. CONCLUSIONS: This study represents the first published document to determine the characteristics of the osteopathic practitioners in Austria using large, national data. It provides new information on where, how, and by whom osteopathic care is delivered. The information provided may contribute to the evidence used by stakeholders and policy makers for the future regulation of the profession in Austria.


Assuntos
Doenças Ósseas , Osteopatia , Medicina Osteopática , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Masculino , Áustria , Estudos Transversais , Europa (Continente)
7.
Healthcare (Basel) ; 10(11)2022 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-36360477

RESUMO

BACKGROUND: This study gives an update on the characteristics of Belgian osteopaths five years after the Benelux Osteosurvey. Additional new data were collected on their professional identity and views on the profession. METHODS: All Belgian osteopaths who could be contacted (n = 1473) were invited to complete a voluntary, online-based, closed-ended survey distributed between May and September 2018. The survey, composed of 52 questions and seven sections, was formally translated from English to Dutch and French and adapted from the original version. Adult, self-defined osteopaths working in Belgium were eligible. Recruitment of participants was performed through all professional associations and the InterMutualistic Agency. Descriptive statistics were used to analyse the data. RESULTS: The survey was completed by 332 osteopaths. Thirty-one per cent of the respondents were female. Almost all the respondents were self-employed (99.4%); half of them worked as part of a team (47.6%). Most respondents had a 5-year part-time training, and the majority had a previous academic degree, mainly in physical therapy (65.8%). According to respondents, most patients seek care for lumbar non-specific low back, pelvis and neck pain. Most respondents strongly define themselves as osteopaths and advertise themselves exclusively as osteopaths. CONCLUSIONS: This survey provided an update of the current characteristics of Belgian osteopathic practitioners and added new information on their professional identity and views on the profession. The information provided could contribute to the body of evidence used by stakeholders and policymakers in the future regulation of the profession in Belgium.

8.
Chiropr Man Therap ; 30(1): 32, 2022 08 31.
Artigo em Inglês | MEDLINE | ID: mdl-36045398

RESUMO

BACKGROUND: Despite controversy regarding its validity and clinical usefulness, manual examination findings still have an important role for manipulative therapies. As an example, somatic dysfunction (SD) remains central to osteopathic practice.This study aims to explore the experienced osteopaths' attitudes concerning SD and its role in osteopathic practice. This qualitative research could contribute to building a consistent paradigm for manual intervention in all musculoskeletal manipulations. METHODS: A thematic analysis with grounded theory elements was used. Data were collected through semi-structured interviews carried out between February and April 2021. A purposive sample of twenty professional osteopaths with past experience in osteopathic care was chosen to reflect the phenomenon's variety. The data analysis was done inductively and in tandem with the recruiting to keep track of data saturation. RESULTS: Eleven osteopaths participated in the study. Three main themes emerged from the data analysis: (1) SD as a safe tissue-touch-based communication tool between operator and person complex adaptive health system; (2) The treatment of SD is shareable between osteopaths, other health professionals, and the patients involved in the therapeutic pathway improving body awareness and health; (3) The development of the SD concept in research and practice to better clarify osteopathic profession identity and definition. CONCLUSIONS: A panel of expert osteopaths consider the concept of SD as a valuable tool integrated into the osteopathic evaluation and treatment process. The shared concept and clinical application of SD is informed by person-centered care concepts and from the fields of neuroscience, cognitive and complexity science. Our study reports a common need among osteopaths to develop an evidence-based framework of SD to allow the best development of the osteopathic profession.


Assuntos
Medicina Osteopática , Médicos Osteopáticos , Humanos , Médicos Osteopáticos/psicologia , Exame Físico , Pesquisa Qualitativa , Inquéritos e Questionários
9.
J Dent ; 119: 104072, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35189313

RESUMO

OBJECTIVES: To assess accuracy of implant complete-arch digital impression with intraoral scanner (IOS) and implant scanbody splinting (ISS). METHODS: An edentulous mandibular model with 4 analogues was fabricated. Four polyetheretherketone (PEEK) implant scanbodies (ISBs) were scanned, according to a randomized sequence, by investigated IOS with (ISS+) and without implant scanbody splinting (ISS-), resulting in 30 test and 30 control files. The model was digitized by industrial optical scanner and the related file superimposed to the test and control files by a best fit algorithm. Linear (ΔX, ΔY and ΔZ-axis) and angular deviations (ΔANGLE) were evaluated for each analogue. A global measure of linear absolute error (ΔASS) was calculated considering the sum of absolute linear discrepancies. Influence of ISS and implant position on IOS accuracy was assessed using General Linear Model and possible interaction between ISS and implant position evaluated. RESULTS: Implant position showed a significant main effect (p<0.0001) and interaction with ISS (p=0.0454) when ΔASS was considered as response variable. Posterior implants resulted as less accurate. ISS was able to reduce ΔASS for both distal analogues (4.7, p=0.0188). When ΔANGLE was considered as a response variable, implant position and ISS showed significant main and interactive effects (p=0.0039, p<0.0001, p<0.0001). Analogue 3.6 was associated with highest angular discrepancy. This error was significantly reduced by ISS (p<0.0001). CONCLUSIONS: Complete-arch implant digital impression with scanbody splinting showed a significant improvement of the overall accuracy, particularly reducing linear and angular deviations at the most critical posterior implant positions. CLINICAL SIGNIFICANCE: Intraoral scanner accuracy for implant complete-arch digital impression could be improved by a low cost, easy to assemble and use implant scanbodies splinting 3D printed modular chain.


Assuntos
Implantes Dentários , Boca Edêntula , Desenho Assistido por Computador , Técnica de Moldagem Odontológica , Humanos , Imageamento Tridimensional , Modelos Dentários
10.
Materials (Basel) ; 15(3)2022 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-35160873

RESUMO

The aim of this study was to evaluate the influence of implant scanbody (ISB) wear on the accuracy of digital impression for complete-arch. A polymethylmethacrylate (PMMA) edentulous mandibular model with four internal hexagonal interlocking conical connections was scanned with an extraoral optical scanner to achieve a reference file. Four cylindrical polyetheretherketone (PEEK) ISBs were scanned 30 times with IOS, and the test files were aligned to the reference file with a best-fit algorithm. For each analog linear (ΔX, ΔY and ΔZ-axis) and angular deviations (ΔANGLE) were assessed. Euclidean distance (ΔEUC) was calculated from the linear deviation, reporting a mean of 82 µm (SD 61) ranging from 8 to 347 µm. ΔANGLE error mean was 0.33° (SD 0.20), ranging from 0.02 to 0.92°. From a multivariate analysis, when ΔEUC was considered as a response variable, a significant influence of ISB wear by scan number in interaction to position for implant 3.6 was identified (p < 0.0001); when ΔANGLE was considered as a response variable, a significant effect of position 3.6 was recorded ((p < 0.0001). The obtained results showed that the ISB wear negatively influenced the accuracy of IOS, suggesting that ISB base wear could be detrimental for the seating of ISBs on angulated implants.

11.
J Esthet Restor Dent ; 34(1): 203-214, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34994995

RESUMO

OBJECTIVE: To assess clinical, radiological performance of novel navigation guided socket-shield technique (NSS) with immediate implant placement and loading. MATERIALS AND METHODS: Eighteen patients (12 females; age 52.54 ± 4.92; 33-72) treated between January 2018 and June 2019, were investigated, and followed for at least 1 year after definitive prosthesis placement (mean 20.1 months, 18-23). Primary outcomes: implant and prosthetic success rates, surgical, biologic, prosthetic complications. SECONDARY OUTCOMES: marginal bone loss (MBL), implant stability quotient (ISQ), pink esthetic score (PES), plaque and bleeding indexes. RESULTS: Sixty-nine navigation guided socket-shield procedures were performed (27 implant-sites and 42 pontic-sites) and 27 implants (NobelParallel, NobelBiocare AG) positioned and immediately loaded. Mean insertion torque and ISQ at implant positioning were 49 ± 5.34 Ncm (36-74), 73 ± 5.72 (68-81). No implant failure was experienced. Two root-shield exposures with mucositis, ulceration and bleeding were reported at two pontic-sites (2.9%) and successfully treated. No complications were experienced at implant-site leading to an overall NSS success-rate of 100%. No prosthetic complications occurred. Mean MBL was -0.72 ± 0.26 mm (-0.42 to -1.06 mm). PES final at the last follow-up 12.84 ± 0.92. The plaque and bleeding scores were 18.5 ± 6.12 and 3.15 ± 2.21. CONCLUSIONS: Within study limitations, dynamic navigation was effective to streamline execution of socket-shield technique at implant and pontic sites, shortening treatment time and reducing complications. Navigation guided socket-shield technique was reliable to achieve digitally planned shield-to-implant distance, facilitate immediate implant placement and loading and establish the mucosal dimension needed for underlying bone-to-implant protection and esthetic integration. CLINICAL SIGNIFICANCE: The investigated NSS technique overcomes the difficulties related to root preparation at implant and pontic-sites, facilitating immediate implant placement and loading. Dynamic guided surgery contributed to make socket-shield technique less technical-sensitive, shortening time for execution, reducing complication rate.


Assuntos
Implantes Dentários para Um Único Dente , Implantes Dentários , Carga Imediata em Implante Dentário , Pré-Escolar , Prótese Parcial Fixa , Estética Dentária , Feminino , Humanos , Carga Imediata em Implante Dentário/métodos , Estudos Prospectivos , Extração Dentária , Alvéolo Dental/cirurgia , Resultado do Tratamento
12.
Clin Oral Implants Res ; 32(12): 1397-1410, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34467555

RESUMO

OBJECTIVES: To evaluate clinical, radiological performance of novel digital workflow integrating dynamic navigation to streamline in one-visit single-implant immediate loading in aesthetic zone. MATERIAL AND METHODS: Consecutive patients requiring one single-implant in aesthetic zone of both jaws were treated between May and September 2017. Primary outcomes were implant and prosthetic success rates, surgical and prosthetic complications, marginal bone loss (MBL), final pink aesthetic score (PES-f), and implant stability quotient (ISQ-f). Secondary outcomes were ISQ-0 and PES-0 at implant positioning and PES-p at definitive prosthesis placement. Potential effect of jaw (maxilla vs mandible), biotype (thin vs thick), type of incision (flap vs flapless), and implant site (healed vs. post-extractive) on the primary outcomes (MBL, PES-f, and ISQ-f) was evaluated through a multivariable analysis. RESULTS: Fifty-two implants were placed (follow-up 18.6, 15-20 months). One post-extractive implant failed. No other surgical, biological complications occurred, accounting for 98.10% cumulative success rate (CSR). No definitive prostheses failed. Mean MBL was -0.63 ± 0.25 mm (-1.69 to -0.06). PES-f was 12.34 ± 1.41 (9-14). ISQ-f was 78.1 ± 3.2 (70-84). Age had significantly negative effect on MBL and PES-f (p = .0058 and p = .0052). No other variables significantly affected primary outcomes. CONCLUSIONS: Within study limitations, investigated digital workflow integrating dynamic navigation was reliable for single-implant immediate loading in aesthetic zone in one visit. No statistically significant difference was found for MBL, PES-f, and ISQ-f, considering type of incision (flap vs. flapless), implant site (healed vs post-extractive), jaw (maxilla vs. mandible), and biotype (thick vs. thin). Live-tracked dynamic navigation may have contributed to improve operator clinical performance regardless of implant site characteristics. Further investigations are needed to confirm positive outcomes.


Assuntos
Implantes Dentários para Um Único Dente , Implantes Dentários , Carga Imediata em Implante Dentário , Prótese Dentária Fixada por Implante , Estética Dentária , Seguimentos , Humanos , Maxila/cirurgia , Resultado do Tratamento , Fluxo de Trabalho
13.
Materials (Basel) ; 14(6)2021 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-33810040

RESUMO

Implant abutment connection was described among the main causes of peri-implant bone resorption. The aim of this in vitro study was to test the coupling capacity, the surface modification of a new hybrid connection and the influence of repeated connection activations caused during the main clinical and laboratory phases. A total of 40 implant-abutment screw retained systems with 10°-conical and internal hexagon connection were tested. The connection was screwed, fixed to the universal test machine, removed the screw and a pull-out test was performed. Test was repeated five times in succession. Also Scanning Electron Microscopy (SEM) was used to detect microscopically surface modification. Analysis of variance and Tukey tests were used for the statistical analysis. Pull-out test reveals a mean value of 131.35 ± 16.52 Newton Centimeter (N·cm). For each single activation, results from first to fifth were: 113.9 ± 13.02, 126.1 ± 12.81, 138.11 ± 15.15, 138.8 ± 11.90 and 140 ± 12.99 N·cm. A statistically significant difference between the measurements and an increase in the removal force was shown. The collected data supports the use of this new type of connection, resulting in a very strong interface between implant and abutment. Also, repeated activation of connection can promote a better coupling of the implant-abutment interface.

14.
J Esthet Restor Dent ; 33(1): 224-236, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33470044

RESUMO

OBJECTIVE: To assess clinical and radiological performance of novel digital workflow integrating dynamic guided surgery, to streamline execution of implant placement, soft and bone tissue sculpturing, and immediate delivery of navigation guided complete-arch prosthesis. MATERIALS AND METHODS: This proof of concept prospective single cohort study investigated 10 consecutive patients (three males, seven females; mean age 62.5 ± 8.9 years; range, 48-75) requiring at least one complete-arch fixed dental prostheses (FDP) in both jaws, treated between January and August 2019. Primary outcomes were implant and prosthetic success rates, surgical and prosthetic complications. Secondary outcomes were marginal bone loss (MBL), implant stability quotient (ISQ), periodontal parameters (plaque and bleeding indexes). RESULTS: Sixty implants (32 NobelParallel TiUltra and 28 NobelActive TiUltra, Nobel Biocare) were placed and 14 complete-arch FDPs immediately loaded (mean follow-up 16.2 ± 1.7 months, 14-18). One implant failed and was immediately replaced. No other surgical or biological complications occurred, accounting for a cumulative success rate of 98.3%. No prosthetic complication occurred, leading to 100% prosthetic success rate. Mean ISQ at implant placement was 71 ± 2.8 (65-78). The mean MBL was -0.53 ± 0.28 mm (-0.22 to -1.12 mm). Plaque and bleeding scores were 14.4 ± 8.18 and 7.15 ± 4.4, respectively. CONCLUSION: Within the limitations of this proof-of-concept dynamic navigation was effective to deliver in the planned coordinates both implants and prosthesis and guide bone and soft tissue sculpturing. Immediate loading of digitally prefabricated esthetically driven complete-arch FDP was facilitated, resulting in high implant and prosthetic success rates. CLINICAL SIGNIFICANCE: The investigated digital workflow integrating dynamic navigation may overcome the difficulties related to immediate positioning and loading of digitally prefabricated complete-arch FDP. The navigation guided soft and bone tissues sculpturing, associated to xenogeneic collagen matrix grafting, represented a predictable technique to achieve the digitally planned interface, reestablishing the mucosal dimension required for the protection of underlying bone while maintaining tissue health.


Assuntos
Implantes Dentários , Carga Imediata em Implante Dentário , Idoso , Estudos de Coortes , Implantação Dentária Endóssea , Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante , Falha de Restauração Dentária , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
15.
J Prosthodont Res ; 65(1): 119-124, 2021 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-32938863

RESUMO

PURPOSE: To introduce a digitally assisted technique to achieve the ideal soft and bone tissue interface for anatomic-driven pink free implant supported fixed prosthesis, and prefabricate an interim prosthesis to be used the day of the surgery as a prosthetic scaffold to condition the healing. METHODS: The digital assisted soft tissue sculpturing (DASS) technique allows the previsualization of the ideal soft and bone tissue interface and fabricate a computer aided design computer aided manufacturing (CAD-CAM) anatomic-driven pink free complete arch interim prosthesis for the immediate loading. Bone and soft tissue interface as well as the interim prosthesis design are performed in a segmented multiple standard tessellation language (STL) file embedding the bone anatomy, the intraoral surface anatomy (dental and soft tissue), the digital wax-up and the implant positioning. The interim prosthesis is used as a prosthetic scaffold to guide the soft and bone tissue surgical sculpturing and regeneration. CONCLUSIONS: The DASS technique is a predictable integrated digital workflow that simplifies the achievement of a scalloped tissue interface for pink free fixed implant prosthesis, reestablishing the mucosal dimension required for the protection of underlying bone while maintaining tissue health. The surgical sculpturing and maturation of the soft and bone tissue is driven and enhanced by the xenogeneic collagen matrix grafting and prosthetic scaffold effect of the digitally prefabricated interim prosthesis delivered the day of the surgery.


Assuntos
Implantes Dentários , Carga Imediata em Implante Dentário , Desenho Assistido por Computador , Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante
16.
J Prosthodont Res ; 64(2): 128-136, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31255546

RESUMO

PURPOSE: To evaluate the influence of implant scanbody (ISB) material, position and operator on the accuracy of a confocal microscopy intraoral scanning (IOS) for complete-arch implant impression. METHODS: An edentulous maxillary model with 6 internal hexagonal connection analogues was scanned with an extraoral optical scanner to achieve a reference file. Three ISBs made of different materials (polyetheretherketone (Pk), titanium (T) and Pk with a titanium base (Pkt)) were scanned with IOS by 3 operators. The resulting 45 test files were aligned to the reference file with a best fit algorithm. Linear (ΔX, ΔY and ΔZ-axis) and angular deviations (ΔANGLE) were assessed. Absolute values of the linear discrepancies were summed up to obtain a global measure of linear absolute error (ΔASS). Influence of ISB material, position and operator was statistically assessed using the mixed general linear model. RESULTS: At multivariate analysis, whenΔASS was considered as response variable, it was identified a significant influence of material (p<0.0001) and position (p=0.0009) while no significant operator effect was detected. When ΔANGLE was considered as response variable, material and position significantly influenced the expected ΔANGLE (p=0.0232 and p<0.0001) and no operator effect was identified. CONCLUSIONS: The investigated IOS for complete-arch digital impression was influenced by the ISB material with peek reporting the best results on both linear and angular measurements followed by titanium, peek-titanium resulting as the less accurate. Implant angulation affected significantly the linear deviations while implant position the angular deviations. Operator did not show any significant effect on the IOS accuracy.


Assuntos
Implantes Dentários , Técnica de Moldagem Odontológica , Desenho Assistido por Computador , Materiais para Moldagem Odontológica , Imageamento Tridimensional , Modelos Dentários , Distribuição Aleatória
17.
J Prosthodont Res ; 62(4): 514-517, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29655527

RESUMO

PURPOSE: To introduce a proof of concept technique and new integrated workflow to optimize the functional and esthetic outcome of the implant-supported restorations by means of a 3-dimensional (3D) facially-driven, digital assisted treatment plan. METHODS: The Smiling Scan technique permits the creation of a virtual dental patient (VDP) showing a broad smile under static conditions. The patient is exposed to a cone beam computed tomography scan (CBCT), displaying a broad smile for the duration of the examination. Intraoral optical surface scanning (IOS) of the dental and soft tissue anatomy or extraoral optical surface scanning (EOS) of the study casts are achieved. The superimposition of the digital imaging and communications in medicine (DICOM) files with standard tessellation language (STL) files is performed using the virtual planning software program permitting the creation of a VDP. CONCLUSIONS: The smiling scan is an effective, easy to use, and low-cost technique to develop a more comprehensive and simplified facially driven computer-assisted treatment plan, allowing a prosthetically driven implant placement and the delivery of an immediate computer aided design (CAD) computer aided manufacturing (CAM) temporary fixed dental prostheses (CAD/CAM technology).


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Implantação Dentária/métodos , Implantes Dentários , Planejamento de Prótese Dentária , Prostodontia/métodos , Sorriso/fisiologia , Cirurgia Assistida por Computador/métodos , Desenho Assistido por Computador , Humanos , Imageamento Tridimensional
18.
Compend Contin Educ Dent ; 39(3): e9-e12, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29493252

RESUMO

The growing interest in minimally invasive implant placement and delivery of a prefabricated provisional prosthesis immediately, thus minimizing "time to teeth," has led to the development of numerous 3-dimensional (3D) planning software programs. Given the enhancements associated with fully digital workflows, such as better 3D soft-tissue visualization and virtual tooth rendering, computer-guided implant surgery and immediate function has become an effective and reliable procedure. This article describes how modern implant planning software programs provide a comprehensive digital platform that enables efficient interplay between the surgical and restorative aspects of implant treatment. These new technologies that streamline the overall digital workflow allow transformation of the digital wax-up into a personalized, CAD/CAM-milled provisional restoration. Thus, collaborative digital workflows provide a novel approach for time-efficient delivery of a customized, screw-retained provisional restoration on the day of implant surgery, resulting in improved predictability for immediate function in the partially edentate patient.


Assuntos
Implantação Dentária Endóssea/métodos , Implantes Dentários , Planejamento de Prótese Dentária/métodos , Restauração Dentária Temporária , Arcada Edêntula/cirurgia , Fluxo de Trabalho , Desenho Assistido por Computador , Prótese Dentária Fixada por Implante/métodos , Humanos , Carga Imediata em Implante Dentário/métodos , Software , Cirurgia Assistida por Computador/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...