Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 92
Filtrar
2.
Arch Orthop Trauma Surg ; 141(12): 2323-2328, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34292380

RESUMO

INTRODUCTION: The effect of patient anxiety during the perioperative period has been shown to be of great importance in its influence on post-operative recovery. Over the last 10 years, virtual reality (VR) has been developed in anesthesia for patient's distraction by immersion. The aim of this study was to evaluate post-operative patient anxiety the day after TKA surgery under spinal anesthesia (SA) with or without VR distraction. MATERIALS AND METHODS: A single-center, prospective cohort study was performed looking at patients undergoing TKA surgery under SA with a VR headset (group 1) compared with those undergoing the same procedure with standard protocol (group 2). Data using a validated scoring system looking at patient anxiety (STAI Y-1) were collected. Secondary endpoints were need for sedation during surgery, intraoperative complications (hypotension and oxygen need), postoperative pain and comfort scores (VAS) and patient satisfaction. RESULTS: Ten patients (group 1) received the VR headset during surgery and 10 (group 2) received the standard protocol established in our center. Average age was 73 years old. No difference was found in post-operative patient anxiety regarding to STAI Y-1 score (95% CI - 7 to 10, p = 0.71. There was a decrease of sedation and intra-operative adverse event as hypotension and oxygen requirement in group 1 (p < 0.0001, p = 0.015, p = 0.0054), and a significant increase in comfort score (p = 0.002). No difference in patient satisfaction was found. CONCLUSION: Using VR for immersive distraction seemed to lead to no difference in patient anxiety in TKA under SA. Intra-operative adverse events were decreased, and post-operative comfort was increased. Patient satisfaction was not modified. This preliminary study is encouraging and gives us arguments to involve larger number of patients while exploring the various possibilities offered by VR.


Assuntos
Raquianestesia , Artroplastia do Joelho , Realidade Virtual , Idoso , Ansiedade , Humanos , Estudos Prospectivos
3.
Bone Joint J ; 101-B(7): 848-851, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31256673

RESUMO

AIMS: The aims of this study were to compare the mean duration of antibiotic release and the mean zone of inhibition between vancomycin-loaded porous tantalum cylinders and antibiotic-loaded bone cement at intervals, and to evaluate potential intrinsic antimicrobial properties of tantalum in an in vitro medium environment against methicillin-sensitive Staphylococcus aureus (MSSA). MATERIALS AND METHODS: Ten porous tantalum cylinders and ten cylinders of cement were used. The tantalum cylinders were impregnated with vancomycin, which was also added during preparation of the cylinders of cement. The cylinders were then placed on agar plates inoculated with MSSA. The diameter of the inhibition zone was measured each day, and the cylinders were transferred to a new inoculated plate. Inhibition zones were measured with a Vernier caliper and using an automated computed evaluation, and the intra- and interobserver reproducibility were measured. The mean inhibition zones between the two groups were compared with Wilcoxon's test. RESULTS: MSSA was inhibited for 12 days by the tantalum cylinders and for nine days by the cement cylinders. At day one, the mean zone of inhibition was 28.6 mm for the tantalum and 19.8 mm for the cement group (p < 0.001). At day ten, the mean zone of inhibition was 3.8 mm for the tantalum and 0 mm for the cement group (p < 0.001). The porous tantalum cylinders soaked only with phosphate buffered solution showed no zone of inhibition. CONCLUSION: Compared with cement, tantalum could release antibiotics for longer. Further studies should assess the advantages of using antibiotic-loaded porous tantalum implants at revision arthroplasty. Cite this article: Bone Joint J 2019;101-B:848-851.


Assuntos
Antibacterianos/administração & dosagem , Cimentos Ósseos , Sistemas de Liberação de Medicamentos , Staphylococcus aureus/efeitos dos fármacos , Tantálio , Vancomicina/administração & dosagem , Antibacterianos/farmacologia , Antibacterianos/uso terapêutico , Artroplastia de Substituição/instrumentação , Humanos , Prótese Articular , Testes de Sensibilidade Microbiana , Variações Dependentes do Observador , Infecções Relacionadas à Prótese/prevenção & controle , Fatores de Tempo , Vancomicina/farmacologia , Vancomicina/uso terapêutico
5.
Bone Joint J ; 100-B(7): 839-844, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29954209

RESUMO

Aims: In patients where the proximal femur shows gross deformity due to degenerative changes or fracture, the contralateral femur is often used to perform preoperative templating for hip arthroplasty. However, femurs may not be symmetrical: the aim of this study was to determine the degree of variation between hips in healthy individuals and to determine whether it is affected by demographic parameters. Materials and Methods: CT-scan based modelling was used to examine the pelvis and bilateral femurs of 345 patients (211 males, 134 women; mean age 62 years (standard deviation (sd) 17), mean body mass index 27 kg/m2 (sd 5)) representing a range of ethnicities. The femoral neck-shaft angle (NSA), femoral offset (FO), femoral neck version (FNV), femoral length (FL), femoral canal flare index (fCFI), and femoral head radius (FHr) were then determined for each patient. All measurements were constructed using algorithm-calculated landmarks, resulting in reproducible and consistent constructs for each specimen. We then analyzed femoral symmetry based on absolute differences (AD) and percentage asymmetry (%AS) following a previously validated method. Results: We found an asymmetry > 2% for NSA (mean AD 2.9°, mean %AS 2.3; p = 0.03), FO (AD 3.8 mm, %AS 9.1 ; p = 0.01), FNV (AD 5.1°, %AS 46.7 ; p = 0.001) and fCFI (AD 0.2 mm, %AS 5.4 ; p = 0.7). Significant relationships were found for AD regarding NSA and ethnicity (p = 0.037), FL and height (R2 = 0.22), and fCFI and gender (R2 = 0.34). Conclusion: Our data confirm the presence of asymmetry of proximal femurs, which is mostly independent of demographic parameters. In cases where contralateral templating is used, such asymmetry may lead to inaccurate anatomical restoration of the hip if the templated sizes are routinely implanted. However, the clinical impact cannot be determined from our investigation. Cite this article: Bone Joint J 2018;100-B:839-44.


Assuntos
Fêmur/diagnóstico por imagem , Articulação do Quadril/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/métodos , Bases de Dados Factuais , Feminino , Fêmur/anormalidades , Fêmur/cirurgia , Articulação do Quadril/cirurgia , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
6.
Orthop Traumatol Surg Res ; 104(2): 203-207, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29408566

RESUMO

INTRODUCTION: In reconstructions of the anterior cruciate ligament (ACL), tibial fixation can be the weak point in the assembly during the early postoperative period. The present study sought to compare pull-out strength between four tibial fixation systems used in ACL reconstruction. HYPOTHESIS: The study hypothesis was that all four devices show ≥450N pull-out strength with comparable biomechanical breakage characteristics. MATERIAL AND METHODS: An experimental study used a mechanical model to perform axial traction on a synthetic ligament (polypropylene cord folded in four) implanted in an artificial tibia (Sawbones Proximal Tibia # 1116-2: model: normal anatomy; solid foam; size: medium) using four tibial fixation systems: Ligafix® interference screw (SBM™); Bio-Intrafix® (Mitek™); Translig® (SBM™); RIGIDfix® (SBM™). For each system, four models were tested using an Instron 5566® traction machine, allowing 100mm/min stretching up to breakage. Study parameters comprised: pull-out strength, maximal whole assembly slippage, stiffness at breaking point, and type of break. RESULTS: Mean pull-out strength was 450±24N (range, 421-488N) for Ligafix®, 415±60N (327-454N) for Bio-Intrafix®, 539±66N (449-636N) for RigidFix and 1067±211N (736-1301N) for Translig®, and was significantly greater for Translig® than for the other devices (p=0.02), which did not significantly differ from one another. The expected maximal load of 450N was reached in 100% of cases with Translig® and RIGIDfix® and in 50% of cases with Bio-Intrafix® and Ligafix®. There were no significant differences regarding stiffness. Ligafix® showed significantly less slippage than the others (p=0.006), with breakage caused by the ligament sliding between bone and implant. DISCUSSION: In this in-vitro study, the Translig® fixation device showed better pull-out strength than the other three devices tested. TYPE OF STUDY AND LEVEL OF EVIDENCE: Comparative laboratory study. Level II.


Assuntos
Reconstrução do Ligamento Cruzado Anterior/instrumentação , Parafusos Ósseos , Falha de Equipamento , Fenômenos Biomecânicos , Humanos , Teste de Materiais , Estresse Mecânico , Tíbia/cirurgia
7.
Orthop Traumatol Surg Res ; 104(3): 363-367, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29458200

RESUMO

INTRODUCTION: The incidence of periprosthetic femoral fracture is constantly increasing, with high associated morbidity and mortality. Surgical treatment is guided by the Vancouver classification, but the influence of type of treatment on morbidity and mortality has been little analyzed. The theoretical advantage of implant revision over internal fixation is that it should allow earlier weight-bearing, although the impact of this on morbidity and mortality and autonomy has not been demonstrated. We conducted a case-control study, to assess the influence of type of treatment (implant revision or internal fixation) (1) on mobility and autonomy and (2) on morbidity and mortality. HYPOTHESIS: The study hypothesis was that clinical results and morbidity and mortality do not differ between these two types of treatment. METHODS: A retrospective study included 70 patients with a total of 71 femoral periprosthetic fractures treated between 2007 and 2014. Two treatment groups, comparable for mean age, gender and ASA and Parker scores, were studied. Mean age was 78±13.5years (range, 23-95years). Thirty-six fractures (50.7%) were treated by implant revision via a posterolateral approach, using a revision stem with (n=11) or without cement (n=25) (REVISION group); immediate postoperative weight-bearing was authorized. Thirty-five fractures (49.3%) were treated by open reduction and internal fixation, using a locking plate (ORIF group); weight-bearing was authorized only in the third month. Mean follow-up was 43±27months (range, 0.75-107months). RESULTS: Autonomy on Parker score was reduced by 2 points at 1year's follow-up. Mean preoperative scores were 7.32±1.79 (range, 3-9) and 7.43±1.79 (range, 4-9) in the REVISION and ORIF group, respectively, (p=0.8), falling to 5.06±2.6 (range, 0-9) and 4.5±2.01 (range, 0-9) respectively at follow-up (p=0.349). Sixteen patients in the REVISION group versus 13 in the ORIF group had made adaptations in their home or changed place of residence (p=0.2). At last follow-up, 18 patients (28.6%) had died: 12 (37.5%) in the ORIF and 6 (19.3%) in the REVISION group (p<0.05). Survival with death as endpoint at a mean 3.5years was 88±11% in the REVISION group versus 51±11% in the ORIF group (p=0.02). Three implant replacements were performed in each group (p=0.83). Twelve medical or surgical complications occurred in the ORIF group (37.5%) and 11 in the REVISION group (34%) (p=0.9). CONCLUSION: Implant revision for periprosthetic femoral fracture showed significantly lower overall mortality than internal fixation, without difference in terms of treatment failure or complications requiring revision surgery. LEVEL OF EVIDENCE: Level III, case-control study.


Assuntos
Artroplastia de Quadril/efeitos adversos , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas , Fraturas Periprotéticas/cirurgia , Reoperação , Adulto , Idoso , Idoso de 80 Anos ou mais , Placas Ósseas , Estudos de Casos e Controles , Feminino , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Redução Aberta , Complicações Pós-Operatórias , Reoperação/efeitos adversos , Estudos Retrospectivos , Taxa de Sobrevida , Falha de Tratamento , Suporte de Carga , Adulto Jovem
8.
Orthop Traumatol Surg Res ; 104(3): 353-358, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29462725

RESUMO

INTRODUCTION: Recent reports described possible mechanical factors in the development and aggravation of osteonecrosis of the femoral head (OFH), but these have yet to be confirmed on dedicated mechanical study. We therefore developed a 3D finite element model based on in-vivo data from patients with incipient OFH, with a view to determining whether the necrosis area was superimposed on the maximal stress area on the femoral head. HYPOTHESIS: The location of the necrosis area is determined by stress on the femoral head. MATERIAL AND METHOD: All patients from the rheumatology department with early stage OFH in our center were investigated. Analysis of CT scans showed stress distribution on the head by 3D finite elements models, enabling determination of necrosis volume within the maximal stress area and of the percentage intersection of necrosis within the stress area (%I n/s: necrosis volume in stress area divided by total stress area volume and multiplied by 100) and of stress within the necrosis area (%I s/n: stress volume in necrosis area divided by total necrosis area volume and multiplied by 100). RESULTS: Nineteen of the 161 patients assessed retrospectively for the period between 2006 and 2015 had incipient unilateral OFH, 10 of whom (4 right, 6 left) had CT scans of sufficient quality for inclusion. Mean age was 52 years (range, 37-81 years). Mean maximal stress was 1.63MPa, mean maximal exported stress volume was 2,236.9 mm3 and mean necrosis volume 6,291.1 mm3. Mean %I n/s was 83% and mean %I s/n 35%, with no significant differences according to gender, age, side or stress volume. There was a strong inverse correlation between necrosis volume and %I s/n (R2=-0.92) and a strong direct correlation between exported stress volume and %I s/n (R2=0.55). %I s/n was greater in small necrosis (<7,000mm3). CONCLUSION: OFH seems to develop within the maximal stress area on the femoral head. The present results need confirmation by larger-scale studies. We consider it essential to take account of these mechanical parameters to reduce failure rates in conservative treatment of OFH. LEVEL OF EVIDENCE: IV.


Assuntos
Necrose da Cabeça do Fêmur/diagnóstico por imagem , Necrose da Cabeça do Fêmur/etiologia , Modelos Teóricos , Estresse Mecânico , Adulto , Idoso , Idoso de 80 Anos ou mais , Simulação por Computador , Feminino , Análise de Elementos Finitos , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
9.
Orthop Traumatol Surg Res ; 104(2): 161-164, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29292123

RESUMO

BACKGROUND: Previous surgical procedures raise technical challenges in performing total knee arthroplasty (TKA) and may affect TKA outcomes. Survival rates of TKA done after trauma or surgery to the knee have not been accurately determined in large populations. The objectives of this retrospective study in 263 patients with TKA after knee trauma or surgery and a follow-up of 10 years were to assess survival, functional outcomes, and the nature and frequency of complications. HYPOTHESIS: Knee trauma or surgery before TKA increases the risk of complications and decreases implant survival. MATERIAL AND METHODS: Two hundred and sixty-three patients (122 [47%] females and 141 [53%] males) underwent TKA between 2005 and 2009 at nine centres in France. Mean age at surgery was 61 years. The patients had knee osteoarthritis secondary to a fracture (n=66), osteotomy (n=131), or ligament injury (n=66). Mean time from trauma or surgery to TKA was 145 months (range, 72-219 months). RESULTS: Major complications were infection (n=12, 4.5%), skin problems (n=8, 3%), and stiffness (n=8, 3%). Ten-year survival to implant exchange for any reason was 89%±2.8%. Flexion range increased by 2.5°±17° (p=0.02) to a mean of 110° (range, 30° to 140°); extension range increased by 4°±7° (p<0.001) to a mean of -1.19 (range, -20° to 0°). Of the 263 patients, 157 (60%) reported little or no pain at last follow-up. Mean postoperative hip-knee-ankle angle was 179°±3.2° (range, 171°-188°). CONCLUSION: TKA performed after knee injury or surgery carries a risk of specific complications (infection, skin problems, and stiffness) and may have a lower survival rate compared to primary TKA. LEVEL OF EVIDENCE: IV, retrospective cohort study.


Assuntos
Artroplastia do Joelho/efeitos adversos , Traumatismos do Joelho/complicações , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Complicações Pós-Operatórias/etiologia , Falha de Prótese , Idoso , Idoso de 80 Anos ou mais , Feminino , França , Humanos , Articulação do Joelho/fisiopatologia , Prótese do Joelho , Ligamentos Articulares/lesões , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/etiologia , Osteotomia/efeitos adversos , Amplitude de Movimento Articular , Estudos Retrospectivos
10.
Orthop Traumatol Surg Res ; 104(1S): S71-S80, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29199087

RESUMO

Relatively poor results have been reported with open reduction and internal fixation of complex fractures around the knee in elderly osteoporotic patients, and primary total knee arthroplasty (TKA) has been proposed as an alternative solution. While limiting the number of procedures, it meets two prerequisites: (1) to save the patient's life, thanks to early weight-bearing, to limit decubitus complications; and (2) to save knee function and patient autonomy, thanks to early knee mobilization. There are 3 main indications: complex articular fractures in elderly patients with symptomatic osteoarthritis prior to fracture; complex articular fractures of the tibial plateau in elderly patients whose bone quality makes internal fixation hazardous; and major destruction of the distal femur in younger patients. Although admitted in emergency, these patients require adequate preoperative management, including a multidisciplinary approach to manage comorbidities, control of anemia and pain, and assessment and management of vascular and cutaneous conditions. Preoperative planning is crucial, to order appropriate implants and materials that may be needed intraoperatively. Surgical technique is based on the basic principles of revision surgery as regards choice of implant, steps of reconstruction, bone defect management and implant fixation. For complex fractures of the distal femur, primary temporary reduction is a useful "trick", to determine the level of the joint line and femoral rotation. Complementary internal fixation may be required in case of diaphyseal extension of the fracture and to prevent inter-prosthetic fractures. In the literature, the results of primary TKA for fracture are encouraging and better than for secondary TKA after failure of non-operative treatment or internal fixation, with lower rates of revision and complications, earlier full weight-bearing and better functional results. Loss of autonomy is, however, frequent, and 1-year mortality is high, especially following complex femoral fractures in the elderly.


Assuntos
Artroplastia do Joelho , Fraturas do Fêmur/cirurgia , Fraturas Intra-Articulares/cirurgia , Fraturas da Tíbia/cirurgia , Diáfises/lesões , Diáfises/cirurgia , Deambulação Precoce , Fixação Interna de Fraturas , Humanos , Fraturas Intra-Articulares/complicações , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/complicações , Planejamento de Assistência ao Paciente , Fraturas da Tíbia/complicações , Suporte de Carga
11.
Orthop Traumatol Surg Res ; 104(3): 347-351, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29122687

RESUMO

BACKGROUND: Links between sagittal spinal alignment and acetabular orientation attract considerable research attention with the goal of optimising prosthetic cup position. However, whether pelvic incidence (PI) is related to anatomic acetabular orientation remains unknown. We therefore conducted a radiological study with the following objectives: to look for correlations between PI and anatomic acetabular parameters; to describe the sacro-pubic angle (SPA), defined by fixed bony pelvic landmarks, and its relations with acetabular anteversion; and to determine whether anatomical parameters (PI and SPA) correlate with demographic characteristics. HYPOTHESIS: PI correlates with anatomical acetabular parameters. MATERIALS AND METHODS: We conducted a computed tomography (CT) study of the pelvises of 150 patients free of degenerative disease. Three parameters were measured: anatomic acetabular orientation in the Lewinnek reference plane, PI, and the SPA subtended by the line connecting the midpoint of the sacral endplate to the pubic symphysis and the anterior pelvic plane. Statistical tests were performed to look for correlations among these parameters. RESULTS: Intra-observer and inter-observer reproducibility was considered highly satisfactory (inter-class correlation coefficient, >86% and >82%, respectively). Mean PI was 58.6°±10.2° (range, 32.8°-97.6°), with no significant differences between genders or across age groups. Mean SPA was 34.7°±5.5° (range, 18.3°-49.8°). Mean anatomic acetabular anteversion (AAA) was greater in females (23.4°; range, 11.5°-34.5°) than in males (20°; range, 7.5°-34.5°) (P<0.001). PI did not correlate with any of the acetabular parameters (PI/AAA, r=0.8 and P=0.33; PI/acetabular inclination on the horizontal, r=-0.96 and P=0.24). SPA correlated significantly with both PI (r=0.33 and P<0.001) and AAA (r=0.33 and P<0.001). DISCUSSION: This CT study of normal pelvises showed that AAA was significantly greater in females and that SPA correlated significantly with both PI and acetabular anteversion. SPA could serve to define the "theoretical" AAA of each individual patient and could thus be incorporated into surgical planning protocols or intra-operative guidance methods for hip replacement surgery. LEVEL OF EVIDENCE: IV, retrospective study with no control group.


Assuntos
Acetábulo/anatomia & histologia , Osso Púbico/anatomia & histologia , Sacro/anatomia & histologia , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Pontos de Referência Anatômicos , Artroplastia de Quadril , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Osso Púbico/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sacro/diagnóstico por imagem , Fatores Sexuais , Tomografia Computadorizada por Raios X , Adulto Jovem
12.
Orthop Traumatol Surg Res ; 103(7): 1035-1039, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28888524

RESUMO

INTRODUCTION: High tibial osteotomy (HTO) is effective in treating isolated medial osteoarthritis of the knee, but subsequent deterioration is inevitable, and total knee arthroplasty (TKA) is then an option. The present study sought to compare TKA following medial opening-wedge HTO (OW-HTO) versus lateral closing-wedge HTO (CW-HTO) in terms of intraoperative data and clinical results. The study hypothesis was that there is no significant difference in clinical results or complications in TKA following OW-HTO or CW-HTO. MATERIAL AND METHOD: A retrospective multicenter (9 centers) study was conducted for the French Society of Orthopedic Surgery and Traumatology (SoFCOT), including 135 TKAs following HTO (58 OW and 77 CW) at a minimum 5 years' follow-up. Mean interval between HTO and TKA was 134 months and was longer in case of CW-HTO (P<0.0001). Mean age at TKA was 65.4 years and older in case of CW-HTO (P=0.021). Tibial slope was greater in case of OW-HTO (P=0.024). Prior to TKA, 55.7% of patients could walk without canes, 98.4% found stairs difficult or impossible and only 19.1% could manage a walking distance greater than 1000m. Mean flexion was 110°; 54.2% of patients showed frontal knee stability and 87.8% sagittal stability; 60.1% had a mechanical axis in varus, without difference according to OW- or CW-HTO. RESULTS: Hardware was almost systematically removed (in 98.5% of cases): in the same step for OW-HTO (P=0.018) or often in 2 steps for CW-HTO. The primary approach was generally re-used (54.2%), but less frequently in the CW-HTO group (P=0.0004). Lateral or medial ligament release was not associated in respectively 78.2% and 79.7% of cases. The TKA implant was usually without stem (87.2%) and was fitted using a conventional technique (74.4%). At a mean 87 months' follow-up, 78.5% of patients could walk without canes, stairs were still difficult or impossible for 67%, and 74.1% could now walk further than 1000m; mean flexion was 110.5°. Overall, 91.5% of patients showed frontal knee stability and 98.2% sagittal stability, without difference according to OW- or CW-HTO. There were 15 complications within 3 months, more often in the OW-HTO group (12.3%) although not significantly, and with no difference in severity. Late complications comprised loosening (5.5%) and infection (3.6%) and were more frequent in the CW-HTO group (12%) (P<0.05). DISCUSSION: The study hypothesis was partially confirmed. The only technical differences concerned hardware removal, often performed in two steps in case of CW-HTO, and TKA approach, which differed from the primary approach in case of CW-HTO. Clinical results were comparable between OW- and CW-HTO, but late complications were more frequent in the CW-HTO group. LEVEL OF EVIDENCE: III; comparative retrospective study.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho/cirurgia , Osteotomia/métodos , Tíbia/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
13.
Orthop Traumatol Surg Res ; 103(7): 1027-1030, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28760374

RESUMO

OBJECTIVE: Intraarticular or periarticular injection of ropivacaine (RI) is an element of current knee surgery practices. The goal of this study was to determine the effects of RI on the mechanical properties of hamstring tendons. We hypothesized that RI would have a detrimental effect on the mechanical properties of periarticular soft tissues METHODS: A tensile test to failure was performed on 120 hamstring tendon segments harvested during ACL reconstruction surgery in 120 patients. Two sets of tensile tests were done. The first evaluated the effect of RI itself on the mechanical properties of tendons: 30 samples were soaked for 1hour in a 2% RI solution and compared to 30 samples soaked in a saline solution (control group). The second evaluated the effect of RI concentration on the mechanical properties of hamstring tendons: 30 samples were soaked for 1hour in a 2% RI solution and 30 samples were soaked in a 7.5% RI solution. RESULTS: In the first test, 29 samples from each group were analyzed as two samples (one in each group) failed at the grip interface. The specimens exposed to 2% RI had lower ultimate tensile strength (Δ=4.4MPa, P=0.001), strain energy (Δ=13MPa, P=0.001) and Young's modulus (Δ=1.6MPa, P=0.02) than the specimens in the control group. There was no significant difference in the strain at failure between groups (Δ=5%, P=0.3). In the second test, one specimen from the 7.5% RI group failed during the preloading and was excluded. There was no significant difference in terms of the load at failure and ultimate tensile stress (Δ=0.45MPa, P=0.6) and strain energy (Δ=0.49MPa, P=0.49) between the two groups. There were significant differences in terms of elongation at failure (Δ=28%, P=0.0003) and Young's modulus (Δ=2.6MPa, P=0.005), with the specimens exposed to 7.5% RI undergoing greater deformation and having a lower Young's modulus. DISCUSSION: While local RI injections are widely performed in clinical practice, the results of this in vitro study point to short-term alterations of the mechanical properties of hamstring tendons. If these results hold in vivo, this could lead to weakness of the soft tissues exposed to this product, particularly the tendons and ligaments around the injection area. LEVEL OF EVIDENCE: Experimental study. Level 1.


Assuntos
Amidas/efeitos adversos , Anestésicos Locais/efeitos adversos , Tendões dos Músculos Isquiotibiais/efeitos dos fármacos , Resistência à Tração/efeitos dos fármacos , Adolescente , Adulto , Fenômenos Biomecânicos , Relação Dose-Resposta a Droga , Feminino , Tendões dos Músculos Isquiotibiais/fisiopatologia , Humanos , Técnicas In Vitro , Doadores Vivos , Masculino , Ropivacaina , Adulto Jovem
14.
Orthop Traumatol Surg Res ; 103(6): 891-897, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28733108

RESUMO

INTRODUCTION: Total elbow arthroplasty (TEA) is one option in distal humerus fracture in elderly osteoporotic patients. HYPOTHESIS: The study hypothesis was that, in patients aged 70years or more, TEA provides functional results and ranges of motion compatible with everyday activity, with a complications rate equal to or lower than with internal fixation, and no loss of autonomy or cognitive impairment. MATERIAL AND METHODS: In this retrospective study, 21 patients receiving TEA for distal humerus fracture were included. Mean follow-up was 3.2years, with functional (Quick DASH and MEPS), cognitive (MMSE), autonomy-related (ADL) and radiological assessment (Morrey). RESULTS: Mean MEPS was 84 and QuickDASH 32.4. Mean extension deficit was 22°, and mean flexion 125°. There was no loss of autonomy or cognitive impairment. The complications rate was 9.5%. There were no revision surgeries. DISCUSSION: TEA proved reliable in comminuted distal humerus fracture in elderly patients. Functional results were comparable to those in the literature, and the complications rate was lower. Long-term implant survival needs confirmation to validate this option as a treatment of choice in these indications in geriatric traumatology. TYPE OF STUDY: Retrospective non-comparative, single-center. LEVEL OF EVIDENCE: 4.


Assuntos
Artroplastia de Substituição do Cotovelo/métodos , Articulação do Cotovelo/cirurgia , Fraturas do Úmero/cirurgia , Osteoporose , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Fixação Interna de Fraturas/métodos , Serviços de Saúde para Idosos , Humanos , Masculino , Amplitude de Movimento Articular , Estudos Retrospectivos , Traumatologia , Resultado do Tratamento
15.
Orthop Traumatol Surg Res ; 103(2): 245-250, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28137553

RESUMO

INTRODUCTION: Treatment of medial tibiofemoral osteoarthritis with a high-tibial osteotomy (HTO) is most effective when the optimal angular correction is achieved. However, conventional instrumentation is limited when multiplanar correction is needed. HYPOTHESIS: Use of patient-specific cutting guides (PSCGs) for HTO provides an accurate correction (difference<2°) relative to the preoperative planning. MATERIALS AND METHODS: Between February 2014 and February 2015, 10 patients (mean age: 46 years [range: 31-59]; grade 1 or 2 osteoarthritis in Ahlbäck's classification) were included prospectively in this reliability and safety study. All patients were operated using the same medial opening-wedge osteotomy technique. Preoperative planning was based on long-leg radiographs and CT scans with 3D reconstruction. The PSGCs were used to align the osteotomy cut and position the screw holes for the plate. The desired correction was achieved in the three planes when the holes on the plate were aligned with the holes drilled based on the PSCG. Preoperatively, the mean HKA angle was 171.9° (range: 166-179°), the mean proximal tibial angle was 87° (86-88°) and the mean tibial slope was 7.8° (1-22°). The postoperative correction was compared to the planned correction using 3D CT scan transformations. Intraoperative and postoperative complications were assessed at a minimum follow-up of 1 year. RESULTS: The procedure was successfully carried out in all patients with the PSCGs. On postoperative long-leg radiographs, the mean HKA was 182.3° (180-185°); on the CT scan, the mean tibial mechanical angle was 94° (90-98°) and the mean tibial slope was 7.1° (4-11°). In 19 out of 20 postoperative HKA and slope measurements, the difference between the planned and achieved correction was <2° based on the 3D analysis of the three planes in space; in the other case, the slope was 13° instead of the planned 10°. The intra-class correlation coefficients between the postoperative and planned parameters were 0.98 [0.92-0.99] for the HKA and 0.96 [0.79-0.99] for the tibial slope. There were no surgical site infections; one patient had a postoperative hematoma that resolved spontaneously. DISCUSSION: The results of this study showed that use of PSCGs in HTO procedures helps to achieve optimal correction in a safe and reliable manner. LEVEL OF EVIDENCE: IV - Prospective cohort study.


Assuntos
Osteoartrite do Joelho/cirurgia , Osteotomia/instrumentação , Impressão Tridimensional , Tíbia/cirurgia , Adulto , Placas Ósseas , Parafusos Ósseos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/diagnóstico por imagem , Osteotomia/métodos , Projetos Piloto , Período Pós-Operatório , Estudos Prospectivos , Radiografia , Reprodutibilidade dos Testes , Tíbia/diagnóstico por imagem , Tomografia Computadorizada por Raios X
16.
Bone Joint J ; 98-B(11): 1479-1488, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27803223

RESUMO

AIMS: The aim of this consensus was to develop a definition of post-operative fibrosis of the knee. PATIENTS AND METHODS: An international panel of experts took part in a formal consensus process composed of a discussion phase and three Delphi rounds. RESULTS: Post-operative fibrosis of the knee was defined as a limited range of movement (ROM) in flexion and/or extension, that is not attributable to an osseous or prosthetic block to movement from malaligned, malpositioned or incorrectly sized components, metal hardware, ligament reconstruction, infection (septic arthritis), pain, chronic regional pain syndrome (CRPS) or other specific causes, but due to soft-tissue fibrosis that was not present pre-operatively. Limitation of movement was graded as mild, moderate or severe according to the range of flexion (90° to 100°, 70° to 89°, < 70°) or extension deficit (5° to 10°, 11° to 20°, > 20°). Recommended investigations to support the diagnosis and a strategy for its management were also agreed. CONCLUSION: The development of standardised, accepted criteria for the diagnosis, classification and grading of the severity of post-operative fibrosis of the knee will facilitate the identification of patients for inclusion in clinical trials, the development of clinical guidelines, and eventually help to inform the management of this difficult condition. Cite this article: Bone Joint J 2016;98-B:1479-88.


Assuntos
Articulação do Joelho/patologia , Articulação do Joelho/cirurgia , Complicações Pós-Operatórias/diagnóstico , Algoritmos , Consenso , Fibrose , Humanos , Articulação do Joelho/fisiopatologia , Complicações Pós-Operatórias/classificação , Complicações Pós-Operatórias/fisiopatologia , Complicações Pós-Operatórias/terapia , Amplitude de Movimento Articular , Sistema de Registros , Índice de Gravidade de Doença
17.
Orthop Traumatol Surg Res ; 102(4): 429-33, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27052939

RESUMO

BACKGROUND: Successful management of large bone defects is of crucial importance when performing revision total knee arthroplasty (TKA). Trabecular tantalum cones may improve prosthesis fixation via their potential for reconstructing a stable metaphyseal support. The objective of this study was to evaluate the clinical and radiological outcomes and the complications of tantalum cones in revision TKA. HYPOTHESIS: Trabecular tantalum cones provide stable and durable metaphyseal reconstruction when used during revision TKA. MATERIAL AND METHODS: Trabecular Metal™ cones (Zimmer, Warsaw, IN, USA) were used for 52 revision TKAs in 51 patients (mean age, 68±9 years) managed in two centres between 2008 and 2013. A rotating hinge prosthesis was chosen for 38 (73%) knees and a condylar constrained knee prosthesis for 14 (27%) knees, with 37 tibial and 34 femoral cones. The two most common reasons for revision surgery were aseptic loosening (n=22, 42%) and infection (n=19, 37%). The bone loss was severe in most cases. At each centre, after a mean follow-up of 34 months (range, 24-52 months), two independent observers assessed the Knee Society Score (KSS), range of motion, mechanical axis, and osteo-integration for each patient. RESULTS: Mean KSS increased from 46 preoperatively to 77 (P=0.001) at last follow-up and the mean KSS function from 39 to 57 (P=0.007). Mean range of motion improved from 93° (45°-120°) to 110° (65°-130°) (P=0.001). Mean postoperative mechanical axis was 180° (172°-190°). Radiographic evaluation showed evidence of osteo-integration for all cones. Four revisions were performed for recurrence of infection but none for mechanical failure. DISCUSSION: The findings of our study confirm the biomechanical and biological reliability of Trabecular Metal™ cones used to fill metaphyseal bone defects during revision TKA. LEVEL OF EVIDENCE: IV, retrospective therapeutic study.


Assuntos
Artroplastia do Joelho/instrumentação , Prótese do Joelho , Reoperação/instrumentação , Tantálio , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Desenho de Prótese , Recidiva , Reoperação/métodos , Estudos Retrospectivos , Resultado do Tratamento
18.
Orthop Traumatol Surg Res ; 102(1 Suppl): S9-20, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26797005

RESUMO

Restoration of normal hip biomechanics is a key goal of total hip arthroplasty (THA) and favorably affects functional recovery. Furthermore, a major concern for both the surgeon and the patient is preservation or restoration of limb length equality, which must be achieved without compromising the stability of the prosthesis. Here, definitions are given for anatomic and functional limb length discrepancies and for femoral and hip offset, determined taking anteversion into account. Data on the influence of operated-limb length and offset on patient satisfaction, hip function, and prosthesis survival after THA are reviewed. Errors may adversely impact function, quality of life, and prosthetic survival and may also generate conflicts between the surgeon and patient. Surgeons rely on two- or three-dimensional preoperative templating and on intraoperative landmarks to manage offset and length. Accuracy can be improved by using computer-assisted planning or surgery and the more recently introduced EOS imaging system. The prosthetic's armamentarium now includes varus-aligned and lateralized implants, as well as implants with modular or custom-made necks, which allow restoration of the normal hip geometry, most notably in patients with coxa vara or coxa valga. Femoral anteversion must also receive careful attention. The most common errors are limb lengthening and a decrease in hip offset. When symptoms are caused by an error in length and/or offset, revision arthroplasty may deserve consideration.


Assuntos
Artroplastia de Quadril/métodos , Fêmur/cirurgia , Desigualdade de Membros Inferiores/prevenção & controle , Extremidade Inferior , Complicações Pós-Operatórias/prevenção & controle , Prótese de Quadril , Humanos , Satisfação do Paciente , Cuidados Pré-Operatórios/métodos , Falha de Prótese , Qualidade de Vida , Recuperação de Função Fisiológica , Reoperação
20.
Bone Joint J ; 97-B(10 Suppl A): 9-15, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26430081

RESUMO

Partial knee arthroplasty (PKA), either medial or lateral unicompartmental knee artroplasty (UKA) or patellofemoral arthroplasty (PFA) are a good option in suitable patients and have the advantages of reduced operative trauma, preservation of both cruciate ligaments and bone stock, and restoration of normal kinematics within the knee joint. However, questions remain concerning long-term survival. The goal of this review article was to present the long-term results of medial and lateral UKA, PFA and combined compartmental arthroplasty for multicompartmental disease. Medium- and long-term studies suggest reasonable outcomes at ten years with survival greater than 95% in UKA performed for medial osteoarthritis or osteonecrosis, and similarly for lateral UKA, particularly when fixed-bearing implants are used. Disappointing long-term outcomes have been observed with the first generation of patellofemoral implants, as well as early Bi-Uni (i.e., combined medial and lateral UKA) or Bicompartmental (combined UKA and PFA) implants due to design and fixation issues. Promising short- and med-term results with the newer generations of PFAs and bicompartmental arthroplasties will require long-term confirmation.


Assuntos
Artroplastia do Joelho/métodos , Hemiartroplastia , Prótese do Joelho , Osteoartrite do Joelho/cirurgia , Artroplastia do Joelho/instrumentação , Hemiartroplastia/instrumentação , Humanos , Desenho de Prótese , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...