Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Front Cardiovasc Med ; 11: 1351746, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38464843

RESUMO

Introduction: Out-of-office blood pressure (BP) monitoring is increasingly valuable in the diagnosis and management of hypertension. With advances in wearable BP technologies, the ability to gain insight into BP outside of traditional centers of care has expanded greatly. Methods: Here we explore the usability of a novel, wrist-worn BP cuff monitor for out-of-office data collection with participants following digital cues rather than in-person instruction. Transmitted measurements were used to evaluate BP variation with the time of day and day of week, BP variation with mood, and orthostatic measurements. Results: Fifty participants, with a mean age of 44.5 years, were enrolled and received the BP monitor. 82% of the participants transmitted data via the smartphone application, and the median wear time of the device during the 4-week study was 11 days (IQR 8-17). Discussion: This prospective digital pilot study illustrates the usability of wearable oscillometric BP technology combined with digital cues via a smartphone application to obtain complex out-of-office BP measurements, including orthostatic vital signs and BP associated with emotion. 25 out of 32 participants who attempted orthostatic vital signs based on in-app instruction were able to do so correctly, while 24 participants transmitted BP readings associated with emotion, with a significant difference in BP noted between calm and stressed emotional states.

2.
PLoS One ; 16(10): e0258276, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34610049

RESUMO

BACKGROUND: Atrial fibrillation (AF) is common, often without symptoms, and is an independent risk factor for mortality, stroke and heart failure. It is unknown if screening asymptomatic individuals for AF can improve clinical outcomes. METHODS: mSToPS was a pragmatic, direct-to-participant trial that randomized individuals from a single US-wide health plan to either immediate or delayed screening using a continuous-recording ECG patch to be worn for two weeks and 2 occasions, ~3 months apart, to potentially detect undiagnosed AF. The 3-year outcomes component of the trial was designed to compare clinical outcomes in the combined cohort of 1718 individuals who underwent monitoring and 3371 matched observational controls. The prespecified primary outcome was the time to first event of the combined endpoint of death, stroke, systemic embolism, or myocardial infarction among individuals with a new AF diagnosis, which was hypothesized to be the same in the two cohorts but was not realized. RESULTS: Over the 3 years following the initiation of screening (mean follow-up 29 months), AF was newly diagnosed in 11.4% (n = 196) of screened participants versus 7.7% (n = 261) of observational controls (p<0.01). Among the screened cohort with incident AF, one-third were diagnosed through screening. For all individuals whose AF was first diagnosed clinically, a clinical event was common in the 4 weeks surrounding that diagnosis: 6.6% experienced a stroke,10.2% were newly diagnosed with heart failure, 9.2% had a myocardial infarction, and 1.5% systemic emboli. Cumulatively, 42.9% were hospitalized. For those diagnosed via screening, none experienced a stroke, myocardial infarction or systemic emboli in the period surrounding their AF diagnosis, and only 1 person (2.3%) had a new diagnosis of heart failure. Incidence rate of the prespecified combined primary endpoint was 3.6 per 100 person-years among the actively monitored cohort and 4.5 per 100 person-years in the observational controls. CONCLUSIONS: At 3 years, screening for AF was associated with a lower rate of clinical events and improved outcomes relative to a matched cohort, although the influence of earlier diagnosis of AF via screening on this finding is unclear. These observational data, including the high event rate surrounding a new clinical diagnosis of AF, support the need for randomized trials to determine whether screening for AF will yield a meaningful protection from strokes and other clinical events. TRAIL REGISTRATION: The mHealth Screening To Prevent Strokes (mSToPS) Trial is registered on ClinicalTrials.gov with the identifier NCT02506244.


Assuntos
Fibrilação Atrial/diagnóstico , Programas de Rastreamento , Acidente Vascular Cerebral/prevenção & controle , Telemedicina , Idoso , Determinação de Ponto Final , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
3.
Nat Med ; 27(1): 73-77, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33122860

RESUMO

Traditional screening for COVID-19 typically includes survey questions about symptoms and travel history, as well as temperature measurements. Here, we explore whether personal sensor data collected over time may help identify subtle changes indicating an infection, such as in patients with COVID-19. We have developed a smartphone app that collects smartwatch and activity tracker data, as well as self-reported symptoms and diagnostic testing results, from individuals in the United States, and have assessed whether symptom and sensor data can differentiate COVID-19 positive versus negative cases in symptomatic individuals. We enrolled 30,529 participants between 25 March and 7 June 2020, of whom 3,811 reported symptoms. Of these symptomatic individuals, 54 reported testing positive and 279 negative for COVID-19. We found that a combination of symptom and sensor data resulted in an area under the curve (AUC) of 0.80 (interquartile range (IQR): 0.73-0.86) for discriminating between symptomatic individuals who were positive or negative for COVID-19, a performance that is significantly better (P < 0.01) than a model1 that considers symptoms alone (AUC = 0.71; IQR: 0.63-0.79). Such continuous, passively captured data may be complementary to virus testing, which is generally a one-off or infrequent sampling assay.


Assuntos
COVID-19/diagnóstico , Monitorização Fisiológica/métodos , Dispositivos Eletrônicos Vestíveis , Adulto , Idoso , COVID-19/patologia , Portador Sadio , Feminino , Frequência Cardíaca , Humanos , Masculino , Programas de Rastreamento , Pessoa de Meia-Idade , Autorrelato , Sono , Estados Unidos
4.
J Clin Transl Sci ; 4(5): 457-462, 2020 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-33244436

RESUMO

BACKGROUND: Pregnant women living in rural locations in the USA have higher rates of maternal and infant mortality compared to their urban counterparts. One factor contributing to this disparity may be lack of representation of rural women in traditional clinical research studies of pregnancy. Barriers to participation often include transportation to research facilities, which are typically located in urban centers, childcare, and inability to participate during nonwork hours. METHODS: POWERMOM is a digital research app which allows participants to share both survey and sensor data during their pregnancy. Through non-targeted, national outreach a study population of 3612 participants (591 from rural zip codes and 3021 from urban zip codes) have been enrolled so far in the study, beginning on March 16, 2017, through September 20, 2019. RESULTS: On average rural participants in our study were younger, had higher pre-pregnancy weights, were less racially diverse, and were more likely to plan a home birth compared to the urban participants. Both groups showed similar engagement in terms of week of pregnancy when they joined, percentage of surveys completed, and completion of the outcome survey after they delivered their baby. However, rural participants shared less HealthKit or sensor data compared to urban participants. DISCUSSION: Our study demonstrated the feasibility and effectiveness of enrolling pregnant women living in rural zip codes using a digital research study embedded within a popular pregnancy app. Future efforts to conduct remote digital research studies could help fill representation and knowledge gaps related to pregnant women.

5.
Heart Rhythm O2 ; 1(5): 351-358, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34113893

RESUMO

BACKGROUND: Screening for asymptomatic, undiagnosed atrial fibrillation (AF) has the potential to allow earlier treatment, possibly resulting in prevention of strokes, but also to increase medical resource utilization. OBJECTIVE: To compare healthcare utilization rates during the year following initiation of screening among participants screened for AF by electrocardiogram (ECG) sensor patch compared with a matched observational control group. METHODS: A total of 1718 participants recruited from a health care plan based on age and comorbidities who were screened with an ECG patch (actively monitored group) as part of a prospective, pragmatic research trial were matched by age, sex, and CHA2DS2-VASc score with 3371 members from the same health plan (observational control group). Healthcare utilization, including visits, prescriptions, procedures, and diagnoses, during the 1 year following screening was compared between the groups using health plan claims data. RESULTS: Overall, the actively monitored group had significantly higher rates of cardiology visits (adjusted incidence rate ratio [aIRR] [95% confidence interval (CI)]: 1.43 [1.27, 1.60]), no difference in primary care provider visits (aIRR [95% CI]: 1.0 [0.95, 1.05]), but lower rates of emergency department (ED) visits and hospitalizations (aIRR [95% CI]: 0.80 [0.69, 0.92]) compared with controls. Among those with newly diagnosed AF, the reduction in ED visits and hospitalizations was even greater (aIRR [95% CI]: 0.27 [0.17, 0.43]). CONCLUSION: AF screening in an asymptomatic, moderate-risk population with an ECG patch was associated with an increase in cardiology outpatient visits but also significantly lower rates of ED visits and hospitalizations over the 1 year following screening.

6.
Contemp Clin Trials Commun ; 14: 100318, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30656241

RESUMO

OBJECTIVES: The advent of large databases, wearable technology, and novel communications methods has the potential to expand the pool of candidate research participants and offer them the flexibility and convenience of participating in remote research. However, reports of their effectiveness are sparse. We assessed the use of various forms of outreach within a nationwide randomized clinical trial being conducted entirely by remote means. METHODS: Candidate participants at possibly higher risk for atrial fibrillation were identified by means of a large insurance claims database and invited to participate in the study by their insurance provider. Enrolled participants were randomly assigned to one of two groups testing a wearable sensor device for detection of the arrhythmia. RESULTS: Over 10 months, the various outreach methods used resulted in enrollment of 2659 participants meeting eligibility criteria. Starting with a baseline enrollment rate of 0.8% in response to an email invitation, the recruitment campaign was iteratively optimized to ultimately include website changes and the use of a five-step outreach process (three short, personalized emails and two direct mailers) that highlighted the appeal of new technology used in the study, resulting in an enrollment rate of 9.4%. Messaging that highlighted access to new technology outperformed both appeals to altruism and appeals that highlighted accessing personal health information. CONCLUSIONS: Targeted outreach, enrollment, and management of large remote clinical trials is feasible and can be improved with an iterative approach, although more work is needed to learn how to best recruit and retain potential research participants. TRIAL REGISTRATION: Clinicaltrials.govNCT02506244. Registered 23 July 2015.

7.
Digit Biomark ; 3(3): 176-184, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-32095776

RESUMO

BACKGROUND: The availability of a wide range of innovative wearable sensor technologies today allows for the ability to capture and collect potentially important health-related data in ways not previously possible. These sensors can be adopted in digitalized clinical trials, i.e., clinical trials conducted outside the clinic to capture data about study participants in their day-to-day life. However, having participants activate, charge, and wear the digital sensors for long hours may prove to be a significant obstacle to the success of these trials. OBJECTIVE: This study explores a broad question of wrist-wearable sensor effectiveness in terms of data collection as well as data that are analyzable per individual. The individuals who had already consented to be part of an asymptomatic atrial fibrillation screening trial were directly sent a wrist-wearable activity and heart rate tracker device to be activated and used in a home-based setting. METHODS: A total of 230 participants with a median age of 71 years were asked to wear the wristband as frequently as possible, night and day, for at least a 4-month monitoring period, especially to track heart rhythm during sleep. RESULTS: Of the individuals who received the device, 43% never transmitted any data. Those who used the device wore it a median of ∼15 weeks (IQR 2-24) and for 5.3 days (IQR 3.2-6.5) per week. For rhythm detection purposes, only 5.6% of all recorded data from individuals were analyzable (with beat-to-beat intervals reported). CONCLUSIONS: This study provides some important learnings. It showed that in an older population, despite initial enthusiasm to receive a consumer-quality wrist-based fitness device, a large proportion of individuals never activated the device. However, it also found that for a majority of participants it was possible to successfully collect wearable sensor data without clinical oversight inside a home environment, and that once used, ongoing wear time was high. This suggests that a critical barrier to overcome when incorporating a wearable device into clinical research is making its initiation of use as easy as possible for the participant.

8.
JAMA ; 320(2): 146-155, 2018 07 10.
Artigo em Inglês | MEDLINE | ID: mdl-29998336

RESUMO

Importance: Opportunistic screening for atrial fibrillation (AF) is recommended, and improved methods of early identification could allow for the initiation of appropriate therapies to prevent the adverse health outcomes associated with AF. Objective: To determine the effect of a self-applied wearable electrocardiogram (ECG) patch in detecting AF and the clinical consequences associated with such a detection strategy. Design, Setting, and Participants: A direct-to-participant randomized clinical trial and prospective matched observational cohort study were conducted among members of a large national health plan. Recruitment began November 17, 2015, and was completed on October 4, 2016, and 1-year claims-based follow-up concluded in January 2018. For the clinical trial, 2659 individuals were randomized to active home-based monitoring to start immediately or delayed by 4 months. For the observational study, 2 deidentified age-, sex- and CHA2DS2-VASc-matched controls were selected for each actively monitored individual. Interventions: The actively monitored cohort wore a self-applied continuous ECG monitoring patch at home during routine activities for up to 4 weeks, initiated either immediately after enrolling (n = 1364) or delayed for 4 months after enrollment (n = 1291). Main Outcomes and Measures: The primary end point was the incidence of a new diagnosis of AF at 4 months among those randomized to immediate monitoring vs delayed monitoring. A secondary end point was new AF diagnosis at 1 year in the combined actively monitored groups vs matched observational controls. Other outcomes included new prescriptions for anticoagulants and health care utilization (outpatient cardiology visits, primary care visits, or AF-related emergency department visits and hospitalizations) at 1 year. Results: The randomized groups included 2659 participants (mean [SD] age, 72.4 [7.3] years; 38.6% women), of whom 1738 (65.4%) completed active monitoring. The observational study comprised 5214 (mean [SD] age, 73.7 [7.0] years; 40.5% women; median CHA2DS2-VASc score, 3.0), including 1738 actively monitored individuals from the randomized trial and 3476 matched controls. In the randomized study, new AF was identified by 4 months in 3.9% (53/1366) of the immediate group vs 0.9% (12/1293) in the delayed group (absolute difference, 3.0% [95% CI, 1.8%-4.1%]). At 1 year, AF was newly diagnosed in 109 monitored (6.7 per 100 person-years) and 81 unmonitored (2.6 per 100 person-years; difference, 4.1 [95% CI, 3.9-4.2]) individuals. Active monitoring was associated with increased initiation of anticoagulants (5.7 vs 3.7 per 100 person-years; difference, 2.0 [95% CI, 1.9-2.2]), outpatient cardiology visits (33.5 vs 26.0 per 100 person-years; difference, 7.5 [95% CI, 7.2-7.9), and primary care visits (83.5 vs 82.6 per 100 person-years; difference, 0.9 [95% CI, 0.4-1.5]). There was no difference in AF-related emergency department visits and hospitalizations (1.3 vs 1.4 per 100 person-years; difference, 0.1 [95% CI, -0.1 to 0]). Conclusions and Relevance: Among individuals at high risk for AF, immediate monitoring with a home-based wearable ECG sensor patch, compared with delayed monitoring, resulted in a higher rate of AF diagnosis after 4 months. Monitored individuals, compared with nonmonitored controls, had higher rates of AF diagnosis, greater initiation of anticoagulants, but also increased health care resource utilization at 1 year. Trial Registration: ClinicalTrials.gov Identifier: NCT02506244.


Assuntos
Fibrilação Atrial/diagnóstico , Eletrocardiografia Ambulatorial/instrumentação , Dispositivos Eletrônicos Vestíveis , Idoso , Anticoagulantes/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/epidemiologia , Estudos de Coortes , Comorbidade , Feminino , Recursos em Saúde/estatística & dados numéricos , Humanos , Incidência , Análise de Intenção de Tratamento , Masculino , Programas de Rastreamento , Pessoa de Meia-Idade , Fatores de Risco , Dispositivos Eletrônicos Vestíveis/efeitos adversos
9.
Per Med ; 14(1): 17-25, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-29749824

RESUMO

This study assessed perspectives on whole-genome sequencing (WGS) for rare disease diagnosis and the process of receiving genetic results. Semistructured interviews were conducted with adult patients and parents of minor patients affected by idiopathic diseases (n = 10 cases). Three main themes were identified through qualitative data analysis and interpretation: perceived benefits of WGS; perceived drawbacks of WGS; and perceptions of the return of results from WGS. Findings suggest that patients and their families have important perspectives on the use of WGS in diagnostic odyssey cases. These perspectives could inform clinical sequencing research study designs as well as the appropriate deployment of patient and family support services in the context of clinical genome sequencing.


Assuntos
Testes Genéticos/ética , Medicina de Precisão/psicologia , Doenças Raras/genética , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Atitude Frente a Saúde , Criança , Exoma , Feminino , Testes Genéticos/métodos , Genoma Humano , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Doenças Raras/diagnóstico , Análise de Sequência de DNA/métodos , Sequenciamento Completo do Genoma/ética
10.
PeerJ ; 4: e1554, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26788432

RESUMO

Background. Mobile health and digital medicine technologies are becoming increasingly used by individuals with common, chronic diseases to monitor their health. Numerous devices, sensors, and apps are available to patients and consumers-some of which have been shown to lead to improved health management and health outcomes. However, no randomized controlled trials have been conducted which examine health care costs, and most have failed to provide study participants with a truly comprehensive monitoring system. Methods. We conducted a prospective randomized controlled trial of adults who had submitted a 2012 health insurance claim associated with hypertension, diabetes, and/or cardiac arrhythmia. The intervention involved receipt of one or more mobile devices that corresponded to their condition(s) (hypertension: Withings Blood Pressure Monitor; diabetes: Sanofi iBGStar Blood Glucose Meter; arrhythmia: AliveCor Mobile ECG) and an iPhone with linked tracking applications for a period of 6 months; the control group received a standard disease management program. Moreover, intervention study participants received access to an online health management system which provided participants detailed device tracking information over the course of the study. This was a monitoring system designed by leveraging collaborations with device manufacturers, a connected health leader, health care provider, and employee wellness program-making it both unique and inclusive. We hypothesized that health resource utilization with respect to health insurance claims may be influenced by the monitoring intervention. We also examined health-self management. Results & Conclusions. There was little evidence of differences in health care costs or utilization as a result of the intervention. Furthermore, we found evidence that the control and intervention groups were equivalent with respect to most health care utilization outcomes. This result suggests there are not large short-term increases or decreases in health care costs or utilization associated with monitoring chronic health conditions using mobile health or digital medicine technologies. Among secondary outcomes there was some evidence of improvement in health self-management which was characterized by a decrease in the propensity to view health status as due to chance factors in the intervention group.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...