JACC Cardiovasc Interv ; 17(3): 374-387, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38180419

RESUMO

BACKGROUND: The COVID-19 pandemic adversely affected health care systems. Patients in need of transcatheter aortic valve replacement (TAVR) are especially susceptible to treatment delays. OBJECTIVES: This study sought to evaluate the impact of the COVID-19 pandemic on global TAVR activity. METHODS: This international registry reported monthly TAVR case volume in participating institutions prior to and during the COVID-19 pandemic (January 2018 to December 2021). Hospital-level information on public vs private, urban vs rural, and TAVR volume was collected, as was country-level information on socioeconomic status, COVID-19 incidence, and governmental public health responses. RESULTS: We included 130 centers from 61 countries, including 65,980 TAVR procedures. The first and second pandemic waves were associated with a significant reduction of 15% (P < 0.001) and 7% (P < 0.001) in monthly TAVR case volume, respectively, compared with the prepandemic period. The third pandemic wave was not associated with reduced TAVR activity. A greater reduction in TAVR activity was observed in Africa (-52%; P = 0.001), Central-South America (-33%; P < 0.001), and Asia (-29%; P < 0.001). Private hospitals (P = 0.005), urban areas (P = 0.011), low-volume centers (P = 0.002), countries with lower development (P < 0.001) and economic status (P < 0.001), higher COVID-19 incidence (P < 0.001), and more stringent public health restrictions (P < 0.001) experienced a greater reduction in TAVR activity. CONCLUSIONS: TAVR procedural volume declined substantially during the first and second waves of the COVID-19 pandemic, especially in Africa, Central-South America, and Asia. National socioeconomic status, COVID-19 incidence, and public health responses were associated with treatment delays. This information should inform public health policy in case of future global health crises.


Assuntos
Estenose da Valva Aórtica , COVID-19 , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Pandemias , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/epidemiologia , Resultado do Tratamento , COVID-19/epidemiologia , Sistema de Registros , Fatores de Risco
5.
JACC Cardiovasc Interv ; 15(12): 1266-1274, 2022 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-35738747

RESUMO

BACKGROUND: Data on outcomes of transcatheter aortic valve replacement (TAVR) using balloon-expandable valves (BEVs) or self-expandable valves (SEVs) as well as the impact of center valve preference on these outcomes are limited. OBJECTIVES: The aim of this study was to compare outcomes of TAVR procedures using third-generation BEVs and SEVs stratified by center valve preference. METHODS: In a multicenter registry (n = 17), 13 centers exhibited valve preference (66.6%-90% of volume) and were included. Outcomes were compared between BEVs and SEVs stratified by center valve preference. RESULTS: In total, 7,528 TAVR procedures (3,854 with SEVs and 3,674 with BEVs) were included. The mean age was 81 years, and the mean Society of Thoracic Surgeons score was 5.2. Baseline characteristics were similar between BEVs and SEVs. Need for pacemaker implantation was higher with SEVs at BEV- and SEV-dominant centers (17.8% vs 9.3% [P < 0.001] and 12.7% vs 10.0% [P = 0.036], respectively; HR: 1.51; P for interaction = 0.021), risk for cerebrovascular accident was higher with SEVs at BEV-dominant but not SEV-dominant centers (3.6% vs 1.1% [P < 0.001] and 2.2% vs 1.4% [P = 0.162]; HR: 2.08; P for interaction < 0.01). Aortic regurgitation greater than mild was more frequent with SEVs at BEV-dominant centers and similar with BEVs regardless of center dominance (5.2% vs 2.8% [P < 0.001] and 3.4% vs 3.7% [P = 0.504], respectively). Two-year mortality was higher with SEVs at BEV-dominant centers but not at SEV-dominant centers (21.9% vs 16.9% [P = 0.021] and 16.8% vs 16.5% [P = 0.642], respectively; HR: 1.20; P for interaction = 0.032). CONCLUSIONS: Periprocedural outcomes, aortic regurgitation greater than mild, and 2-year mortality are worse when TAVR is performed using SEVs at BEV-dominant centers. Outcomes are similar regardless of valve type at SEV-dominant centers. The present results stress the need to account for this factor when comparing BEV and SEV outcomes. (The Aortic+Mitral Transcatheter [AMTRAC] Valve Registry; NCT04031274).


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Sistema de Registros , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
6.
Int J Cardiol ; 361: 55-60, 2022 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-35500820

RESUMO

OBJECTIVES: The aim of this study was to evaluate outcomes of real-world patients with aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) with the 34 mm Evolut R (Medtronic, Minneapolis, Minnesota). BACKGROUND: Larger aortic annulus has been associated with increased incidence of paravalvular leaks (PVLs) after TAVR. However, little is known, so far, about the performance of the 34 mm Evolut R in this setting. METHODS: From the multicenter, international, retrospective Horizontal Aorta in Transcatheter Self-expanding Valves (HORSE) registry, including patients who underwent TAVR for native severe AS, we selected patients treated with the 34 mm Evolut R evaluating procedural characteristics and VARC-2 defined device success. We also compared 34 mm Evolut R with other Evolut R sizes. RESULTS: Among the 4434 patients included in the registry, 572 (13%) received the 34 mm Evolut R valve. Mean age was 80.8 ± 6.5 years and the median STS PROM score was 4 [interquartile range 2-6]. Device success was achieved in 87.4% with 7.7% of PVLs; moreover, the rate of permanent pacemaker implantation (PPMI) was 22.4%. Patients who underwent 34 mm Evolut R implantation experienced more in-hospital permanent pacemaker implantation (22.4% vs. 15%; p < 0.001). At multivariate analysis, 34 mm Evolut R did not affect device success (OR: 0.81 [0.60-1.09]; p = 0.151). Device success was consistent with other THVs sizes (87.4% vs. 89.6%; p = 0.157). CONCLUSIONS: THV replacement in patients requiring 34 mm Evolut R has an acceptable performance. Compared to other Medtronic sizes it demonstrated to be comparable in terms of device success, despite an increased rate of pacemaker implantation.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
7.
EuroIntervention ; 17(16): 1289-1297, 2022 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-34673502

RESUMO

BACKGROUND: The mean age of transcatheter aortic valve implantation (TAVI) patients is steadily decreasing. AIMS: The aim of the study was to describe the characteristics, the indications for and the outcomes of TAVI in patients <70 years old. METHODS: All patients undergoing TAVI (n=8,626) from the 18 participating centres between January 2007 and June 2020 were stratified by age (70). For patients <70, the indications for TAVI were extracted from Heart Team discussions and the baseline characteristics and mortality were compared between the two groups. RESULTS: Overall, 640 (7.4%) patients were <70 (9.1% during 2018-2020, p<0.001); the mean age was 65.0±2.3 years. The younger patients were more often male, with bicuspid valves or needing valve-in-valve procedures. They had a higher prevalence of lung disease and diabetes. In 80.7% of cases, the Heart Team estimated an increased surgical risk and TAVI was selected, reflected by an STS score >4% in 20.4%. Five-year mortality was similar (29.4 vs 29.8%, HR 0.95, p=0.432) in the <70 and >70 groups. In the <70 group, mortality was higher for those referred for TAVI due to an increased surgical risk compared to those referred for other reasons (31.6 vs 24.5%, HR 1.23, p=0.021). Mortality was similar regardless of the STS stratum in patients judged by the Heart Team to be at increased surgical risk (32.6 vs 30.4%, HR 0.98, p=0.715). CONCLUSIONS: Use of TAVI in patients <70 is becoming more frequent. The main reason for choosing TAVI is due to an increased surgical risk not adequately represented by the STS score. The outcomes for these patients are similar to those for older TAVI patients. Dedicated trials of TAVI/SAVR in younger patients are needed to guide decisions concerning expansion of TAVI indications. ((ClinicalTrials.gov: NCT04031274).


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
8.
Catheter Cardiovasc Interv ; 99(4): 1172-1180, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34792842

RESUMO

BACKGROUND: The ACURATE neo™ is a novel, second-generation self-expanding supra-annular transcatheter heart valve (THV). The objective of this multi-centre registry is to assess the safety, clinical utility, and impact of 'learning-curve-experience' (LCE) on transcatheter aortic valve replacement outcomes in the United Kingdom (UK) and Ireland. METHODS: We prospectively collected data from seven ACURATE neo™ THV implanting centres (n = 484) between February 2016 and November 2020. We compared mortality rates and outcomes in the LCE group (n = 120) compared to next successive 120 cases. RESULTS: The mean age of the cohort was 81.9(SD: 6.1) years and the majority were in the moderate risk category (EuroSCORE-II):3.3(SD: 3). The 97.5% of cases were performed under local anesthetic. The valve was successfully deployed in 98.8% of cases. The survival rate at 30 days was 97.9%. The incidence of stroke was 2.5%. Life threatening bleeding occurred in 0.6% of cases and vascular access complications occurred in 21 (4.3%) patients. Implantation-related conduction abnormalities occurred in 8.3% but only 5.6% required a PPM. The successful valve deployment occurred in 96% of the patients in the LCE group compared to 100% in the other group (p = 0.04; OR-2[CI 1.7-2.3]). The mortality rates at 30 days (1.7% vs. 1.7%) and 1 year (1.9% vs. 2.7%) were comparable between the two groups. CONCLUSIONS: This study represents the largest published UK and Ireland real-world experience of the ACURATE neo™ valve. The procedural success rates and safety outcomes were excellent and endorse its utility in clinical practice. The LCE appears to have an impact on the successful valve deployment but without translating into short-term or long-term outcomes.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Irlanda , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Reino Unido
10.
Int J Cardiol ; 338: 58-62, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-34090956

RESUMO

BACKGROUND: Horizontal aorta (HA) is an anatomical feature that can pose significant technical challenges for the successful positioning of the bioprosthetic valve during transcatheter aortic valve replacement (TAVR). Physiological range of aortic angle (AA) is unknown; hence there is no cutoff AA for classifying HA. Moreover, patient characteristics predicting HA are under-investigated. METHODS: This was a retrospective analysis of prospective collected data from 16 heart valve centers in Europe. The study utilized a common dataset with a priori agreed-upon definitions and variables. Eligible patients underwent TAVR between 2014 and 2020 and had multidetector computed tomographic imaging data available for determining the AA. The analysis described the distribution of AA and potential predictors of HA. Inter-center variability was also explored. RESULTS: For 4022 patients analyzed, the mean AA ± standard deviation was 49.4° ± 9.4° (median 49°, inter-quartile range [IQR] 12°, range 18-90°). There was no significant difference in mean AA between men and women (49.4° ± 9.1° vs. 49.6° ± 9.3°, respectively; p = 0.53); therefore, 49.4° was accepted as the cutoff value for HA in subsequent analyses. Covariates significantly associated with HA included age (odds ratio [OR]: 1.02, 95% confidence interval [CI]: 1.01-1.04, p < 0.001), body mass index (OR: 1.06, 95% CI: 1.05-1.08, p < 0.01), previous cardiac surgery (OR: 0.58, 95% CI: 0.45-0.75, p < 0.001), and porcelain aorta (OR: 0.66, 95% CI: 0.52-0.85, p = 0.001). Some inter-center variability was observed. CONCLUSIONS: We defined 49.4° as the mean AA, and also associated predictors of HA in a large case series of patients with severe aortic stenosis candidates for TAVR.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Aorta , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Europa (Continente) , Feminino , Humanos , Masculino , Estudos Prospectivos , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
11.
JACC Cardiovasc Interv ; 14(11): 1181-1192, 2021 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-33992550

RESUMO

OBJECTIVES: The purpose of this study was to examine the impact of residual mitral regurgitation (MR) on mortality in patients undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: MR is common in patients undergoing TAVR. Data on optimal management of patients with significant MR after TAVR are limited. METHODS: The registry consisted of 16 TAVR centers (n = 7,303). Outcomes of patients with ≥ moderate versus lesser grade MR after TAVR were compared. RESULTS: In 1,983 (27.2%) patients, baseline MR grade was ≥ moderate. MR regressed in 874 (44.1%) patients and persisted in 1,109 (55.9%) after TAVR. Four-year mortality was higher for those with MR persistence, but not for those with MR regression after TAVR, compared with nonsignificant baseline MR (43.8% vs. 35.1% vs. 32.4%; hazard ratio [HR]: 1.38; p = 0.008; HR: 1.02; p = 0.383, respectively). New York Heart Association functional class III to IV after TAVR was more common in those with MR persistence vs. regression (14.4% vs. 3.9%; p < 0.001). In a propensity score-matched cohort (91 patients' pairs), with significant residual MR after TAVR who did or did not undergo staged mitral intervention, staged intervention was associated with a better functional class through 1 year of follow-up (82.4% vs. 33.3% New York Heart Association functional class I or II; p < 0.001), and a numerically lower 4-year mortality, which was not statistically significant (64.6% vs. 37.5%; HR: 1.66; p = 0.097). CONCLUSIONS: Risk stratification based on improvement in MR and symptoms after TAVR can identify patients at increased mortality risk after TAVR. These patients may benefit from a staged transcatheter mitral intervention, but this requires further proof from future studies. (Transcatheter Treatment for Combined Aortic and Mitral Valve Disease. The Aortic+Mitral TRAnsCatheter [AMTRAC] Valve Registry [AMTRAC]; NCT04031274).


Assuntos
Estenose da Valva Aórtica , Insuficiência da Valva Mitral , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Estudos Retrospectivos , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
12.
JACC Cardiovasc Interv ; 14(2): 172-181, 2021 01 25.
Artigo em Inglês | MEDLINE | ID: mdl-33478633

RESUMO

OBJECTIVES: The aim of this study was to evaluate the short-term safety and efficacy of transcatheter aortic valve replacement (TAVR) with the LOTUS Edge system. BACKGROUND: The LOTUS Edge system was commercially re-released in April 2019. The authors report the first European experience with this device. METHODS: A multicenter, single-arm, retrospective registry was initiated to evaluate short-term clinical outcomes. Included cases are the first experience with this device and new implantation technique in Europe. Clinical, echocardiographic, and computed tomographic data were analyzed. Endpoints were defined according to Valve Academic Research Consortium-2 and were site reported. RESULTS: Between April and November 2019, 286 consecutive patients undergoing TAVR with the LOTUS Edge system at 18 European centers were included. The mean age and Society of Thoracic Surgeons score were 81.2 ± 6.9 years and 5.2 ± 5.4%, respectively. Nearly one-half of all patients (47.9%) were considered to have complex anatomy. Thirty-day major adverse events included death (2.4% [n = 7]) and stroke (3.5% [n = 10]). After TAVR, the mean aortic valve area was 1.9 ± 0.9 cm2, and the mean transvalvular gradient was 11.9 ± 5.7 mm Hg. None or trace paravalvular leak (PVL) occurred in 84.4% and moderate PVL in 2.0%. There were no cases of severe PVL. New permanent pacemaker (PPM) implantation was required in 25.9% among all patients and 30.8% among PPM-naive patients. CONCLUSIONS: Early experience with the LOTUS Edge system demonstrated satisfactory short-term safety and efficacy, favorable hemodynamic data, and very low rates of PVL in an anatomically complex cohort. New PPM implantation remained high. Further study will evaluate if increasing operator experience with the device and new implantation technique can reduce the incidence of PPM implantation.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Europa (Continente) , Humanos , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
16.
J Am Heart Assoc ; 9(22): e017624, 2020 11 17.
Artigo em Inglês | MEDLINE | ID: mdl-33140688

RESUMO

Background The clinical significance of conduction disturbances after transcatheter aortic valve implantation has been described; however, little is known about the influence of baseline ECGs in the prognosis of these patients. Our aim was to study the influence of baseline ECG parameters, including interatrial block (IAB), in the prognosis of patients treated with transcatheter aortic valve implantation. Methods and Results The BIT (Baseline Interatrial Block and Transcatheter Aortic Valve Implantation) registry included 2527 patients with aortic stenosis treated with transcatheter aortic valve implantation. A centralized analysis of baseline ECGs was performed. Patients were divided into 4 groups: normal P wave duration (<120 ms); partial IAB (P wave duration ≥120 ms, positive in the inferior leads); advanced IAB (P wave duration ≥120 ms, biphasic [+/-] morphology in the inferior leads); and nonsinus rhythm (atrial fibrillation/flutter and paced rhythm). The mean age of patients was 82.6±9.8 years and 1397 (55.3%) were women. A total of 960 patients (38.0%) had a normal P wave, 582 (23.0%) had partial IAB, 300 (11.9%) had advanced IAB, and 685 (27.1%) presented with nonsinus rhythm. Mean follow-up duration was 465±171 days. Advanced IAB was the only independent predictor of all-cause mortality (hazard ratio [HR], 1.48; 95% CI, 1.10-1.98 [P=0.010]) and of the composite end point (death/stroke/new atrial fibrillation) (HR, 1.51; 95% CI, 1.17-1.94 [P=0.001]). Conclusions Baseline ECG characteristics influence the prognosis of patients with aortic stenosis treated with transcatheter aortic valve implantation. Advanced IAB is present in about an eighth of patients and is associated with all-cause death and the composite end point of death, stroke, and new atrial fibrillation during follow-up.


Assuntos
Estenose da Valva Aórtica/cirurgia , Fibrilação Atrial/epidemiologia , Bloqueio Interatrial/complicações , Complicações Pós-Operatórias/epidemiologia , Acidente Vascular Cerebral/epidemiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/mortalidade , Eletrocardiografia , Feminino , Humanos , Masculino , Marca-Passo Artificial , Prognóstico , Sistema de Registros
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...