Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Thorac Cardiovasc Surg ; 158(5): 1332-1340, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31005306

RESUMO

OBJECTIVE: We sought to develop an instrument that would enable the delivery of artificial chordae tendineae (ACT) using optical visualization of the leaflet inside the beating heart. METHODS: A delivery instrument was developed together with an ACT anchor system. The instrument incorporates an optically clear silicone grasping surface in which are embedded a camera and LED for direct leaflet visualization during localization, grasping, and chordal delivery. ACTs, comprised of T-shaped anchors and an expanded polytetrafluoroethylene chordae, were fabricated to enable testing in a porcine model. Ex vivo experiments were used to measure the anchor tear-out force from the mitral leaflets. In vivo experiments were performed in which the mitral leaflets were accessed transapically using only optical guidance and ACTs were deployed in the posterior and anterior leaflets (P2 and A2 segments). RESULTS: In 5 porcine ex vivo experiments, the mean force required to tear the anchors from the leaflets was 3.8 ± 1.2 N. In 5 porcine in vivo nonsurvival procedures, 14 ACTs were successfully placed in the leaflets (9 in P2 and 5 in A2). ACT implantation took an average of 3.22 ± 0.83 minutes from entry to exit through the apex. CONCLUSIONS: Optical visualization of the mitral leaflet during chordal placement is feasible and provides direct feedback to the operator throughout the deployment sequence. This enables visual confirmation of the targeted leaflet location, distance from the free edge, and successful deployment of the chordal anchor. Further studies are needed to refine and assess the device for clinical use.


Assuntos
Cordas Tendinosas/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas/normas , Imagem Óptica/métodos , Animais , Desenho de Equipamento , Implante de Prótese de Valva Cardíaca/métodos , Teste de Materiais/métodos , Valva Mitral/cirurgia , Prolapso da Valva Mitral/cirurgia , Modelos Anatômicos , Cirurgia Assistida por Computador/instrumentação , Cirurgia Assistida por Computador/métodos , Suínos
2.
Sci Robot ; 3(14)2018 01 10.
Artigo em Inglês | MEDLINE | ID: mdl-33141697

RESUMO

Robots that reside inside the body to restore or enhance biological function have long been a staple of science fiction. Creating such robotic implants poses challenges both in signaling between the implant and the biological host, as well as in implant design. To investigate these challenges, we created a robotic implant to perform in vivo tissue regeneration via mechanostimulation. The robot is designed to induce lengthening of tubular organs, such as the esophagus and intestines, by computer-controlled application of traction forces. Esophageal testing in swine demonstrates that the applied forces can induce cell proliferation and lengthening of the organ without a reduction in diameter, while the animal is awake, mobile, and able to eat normally. Such robots can serve as research tools for studying mechanotransduction-based signaling and can also be used clinically for conditions such as long-gap esophageal atresia and short bowel syndrome.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...