Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
2.
J Interv Cardiol ; 30(4): 347-355, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28670721

RESUMO

OBJECTIVES: We sought to analyze the percutaneous coronary intervention (PCI) outcomes of very elderly patients (V. Eld. group, age >80 years) and compare their outcomes to a less elderly cohort (Eld. group, age 75-80 years) traditionally reported in the literature. BACKGROUND: Limited data exist on peri-procedural and long-term outcomes following PCI in the V. Eld. (age >80 years), with under-representation of this cohort in randomized controlled trials. These patients present with advanced complex coronary disease and multiple comorbidities. METHODS: All 580 consecutive patients aged ≥75 years (age 80 ± 4.9 years, 57.4% males) undergoing PCI between April 2006 and November 2011 were included. A total of 624 consecutive lesions were identified and analyzed. All V. Eld. patients (n = 253) were subsequently selected, and their outcomes compared to Eld. patients (n = 327). Mean follow-up was 30.8 ± 2.7 months with 98% clinical follow-up achieved. RESULTS: All comparative data are expressed as (V. Eld. vs Eld.) unless otherwise specified. All-cause mortality was significantly higher in the V. Eld. group (11.9% vs 6.1%), although this did not translate into a significant difference in cardiac mortality (6.3% vs 3.7%) or major adverse cardiac and cerebrovascular events (16.2% vs 12.5%). The composite incidence of myocardial infarction (MI), stroke, definite/probable stent thrombosis, and TIMI major bleed was 4.7%, 1.4% 1.9%, and 6.4%, respectively with no significant difference between both cohorts. CONCLUSIONS: This study demonstrates an acceptable occurrence of MI, death, repeat intervention, and stent thrombosis in a high-risk group of V. Eld. patients with de novo lesions. Age alone in the absence of other non-cardiac factors should not prohibit a patient from access to PCI.


Assuntos
Doença da Artéria Coronariana/cirurgia , Intervenção Coronária Percutânea/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Doença da Artéria Coronariana/mortalidade , Feminino , Oclusão de Enxerto Vascular/epidemiologia , Humanos , Estimativa de Kaplan-Meier , Masculino , Infarto do Miocárdio/epidemiologia , Seleção de Pacientes , Acidente Vascular Cerebral/epidemiologia , Fatores de Tempo , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 85(4): 657-64, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25384846

RESUMO

OBJECTIVES: We present a case series of five patients in whom percutaneous paravalvular leak closure with the AVP4 device has been undertaken for symptomatic aortic regurgitation after CoreValve TAVI. BACKGROUND: Significant post-procedure aortic regurgitation (AR) is often difficult to assess, and is an important predictor of adverse outcome following TAVI. Paravalvular leak closure is an established procedure for surgical aortic prostheses, and has been undertaken for Edwards TAVIs, but has not been described for closure of CoreValve paravalvular leaks. METHODS AND RESULTS: Five patients were treated (mean age 81 ± 4 years) with residual grade 3-4 AR following placement of a single CoreValve (n = 2), double CoreValve (n = 2) or CoreValve within a bioprosthetic AVR (n = 1). The mean time post TAVI implantation was 308 ± 269 days. All patients were symptomatic with persistent NYHA Grade III dyspnoea. 6 devices were deployed successfully, with mean procedure time of 109 ± 23 min. There were no procedural complications and all patients were discharged home by Day 2. Residual AR after treatment was grade 0 (n = 2), grade 1 (n = 1), grade 2 (n = 1) and grade 3 (n = 1). Symptomatic improvement was noted in all 4 patients who have been reviewed in clinic since. CONCLUSIONS: This small series demonstrates the feasibility of paravalvular leak closure with the CoreValve TAVI, despite the adverse aortic lattice. The AVP4 device is ideally suited to this situation as it will pass through a 0.038' lumen and can therefore be delivered down standard diagnostic catheters.


Assuntos
Insuficiência da Valva Aórtica/terapia , Estenose da Valva Aórtica/terapia , Valva Aórtica , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Aortografia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Ecocardiografia Doppler em Cores , Ecocardiografia Transesofagiana , Estudos de Viabilidade , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Tempo de Internação , Masculino , Desenho de Prótese , Retratamento , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...