Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Sci Rep ; 14(1): 10409, 2024 05 06.
Artigo em Inglês | MEDLINE | ID: mdl-38710782

RESUMO

In transcatheter aortic valve implantation (TAVI), final device position may be affected by device interaction with the whole aortic landing zone (LZ) extending to ascending aorta. We investigated the impact of aortic LZ curvature and angulation on TAVI implantation depth, comparing short-frame balloon-expanding (BE) and long-frame self-expanding (SE) devices. Patients (n = 202) treated with BE or SE devices were matched based on one-to-one propensity score. Primary endpoint was the mismatch between the intended (HPre) and the final (HPost) implantation depth. LZ curvature and angulation were calculated based on the aortic centerline trajectory available from pre-TAVI computed tomography. Total LZ curvature ( k L Z , t o t ) and LZ angulation distal to aortic annulus ( α L Z , D i s t a l ) were greater in the SE compared to the BE group (P < 0.001 for both). In the BE group, HPost was significantly higher than HPre at both cusps (P < 0.001). In the SE group, HPost was significantly deeper than HPre only at the left coronary cusp (P = 0.013). At multivariate analysis, α L Z , D i s t a l was the only independent predictor (OR = 1.11, P = 0.002) of deeper final implantation depth with a cut-off value of 17.8°. Aortic LZ curvature and angulation significantly affected final TAVI implantation depth, especially in high stent-frame SE devices reporting, upon complete release, deeper implantation depth with respect to the intended one.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Substituição da Valva Aórtica Transcateter , Substituição da Valva Aórtica Transcateter/métodos , Humanos , Masculino , Feminino , Idoso de 80 Anos ou mais , Idoso , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Tomografia Computadorizada por Raios X , Aorta/diagnóstico por imagem , Aorta/cirurgia , Resultado do Tratamento , Próteses Valvulares Cardíacas , Estudos Retrospectivos
2.
Circ Cardiovasc Interv ; 16(7): e012636, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37417226

RESUMO

BACKGROUND: Anomalous aortic origin of coronary artery (AAOCA) with intramural segment is associated with risk of sudden cardiac death, probably related to a compressive mechanism exerted by the aorta. However, the intramural compression occurrence and magnitude during the cardiac cycle remain unknown. We hypothesized that (1) in end diastole, the intramural segment is narrower, more elliptic, and has greater resistance than extramural segment; (2) the intramural segment experiences a further compression in systole; and (3) morphometry and its systolic changes vary within different lumen cross-sections of the intramural segment. METHODS: Phasic changes of lumen cross-sectional coronary area, roundness (minimum/maximum lumen diameter), and hemodynamic resistance (Poiseuille law for noncircular sections) were derived from intravascular ultrasound pullbacks at rest for the ostial, distal intramural, and extramural segments. Data were obtained for 35 AAOCA (n=23 with intramural tract) after retrospective image-based gating and manual lumen segmentation. Differences between systolic and end-diastolic phases in each section, between sections of the same coronary, and between AAOCA with and without intramural tract were assessed by nonparametric statistical tests. RESULTS: In end diastole, both the ostial and distal intramural sections were more elliptical (P<0.001) than the reference extramural section and the correspondent sections in AAOCA without intramural segment. In systole, AAOCA with intramural segment showed a flattening at the ostium (-6.76% [10.82%]; P=0.024) and a flattening (-5.36% [16.56%]; P=0.011), a narrowing (-4.62% [11.38%]; P=0.020), and a resistance increase (15.61% [30.07%]; P=0.012) at the distal intramural section. No-intramural sections did not show morphological changes during the entire cardiac cycle. CONCLUSIONS: AAOCA with intramural segment has pathological segment-specific dynamic compression mainly in the systole under resting conditions. Studying AAOCA behavior with intravascular ultrasound during the cardiac cycle may help to evaluate and quantify the severity of the narrowing.


Assuntos
Anomalias dos Vasos Coronários , Vasos Coronários , Humanos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Estudos Retrospectivos , Estudos Transversais , Anomalias dos Vasos Coronários/diagnóstico por imagem , Anomalias dos Vasos Coronários/complicações , Resultado do Tratamento , Aorta/diagnóstico por imagem
4.
Eur Heart J Open ; 2(4): oeac043, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36117948

RESUMO

Aims: As the indications to transcatheter aortic valve replacement (TAVR) expand to patients at increasingly lower risk, procedure-related vascular and bleeding complications events must be minimized. We aimed to evaluate the impact of different large-bore arterial access closure devices on clinical outcomes after TAVR. Methods and results: We searched for papers that reported outcomes according to the type of vascular closure device/technique used after TAVR and performed a Bayesian network meta-analysis (NMA). Fifteen studies involving 9259 patients who underwent access site closure using PROSTAR™ XL percutaneous vascular surgical system (Abbott Vascular, Santa Clara, CA, USA), Perclose ProGlide™ suture-mediated closure system (Abbott), or MANTATM vascular closure device (Teleflex, Morrisville, NC, USA) were included. NMA showed MANTA to have the highest likelihood of reducing a primary composite endpoint of intra-hospital death, major vascular complications, and major or life-threatening bleedings [surface under the cumulative ranking curve analysis (SUCRA) 94.8%], but this was mitigated when only randomized clinical trials and propensity-matched cohorts were included (SUCRA 56.1%). The ProGlide showed the highest likelihood to reduce major or life-threatening bleedings, especially with increasing procedural complexity, and the MANTA device to reduce major and minor vascular complications. The ProStar XL device performed poorly in all explored endpoints. Conclusion: Available evidence summarized through a NMA shows that ProGlide and MANTA devices appear to be both valid vascular closure devices globally and to be the best options to minimize vascular complications and reduce bleeding in patients undergoing TAVR, respectively.

5.
Hellenic J Cardiol ; 66: 59-66, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35550178

RESUMO

The Academic Research Consortium High Bleeding Risk (ARC-HBR) criteria aims to stratify patients undergoing percutaneous coronary intervention (PCI) and are now recommended by international guidelines to stratify bleeding risk in clinical practice. We searched electronic databases from 2019 (ARC-HBR proposal) up to February 2021 for studies that reported the occurrence of major bleedings according to ARC-HBR status in patients undergoing PCI and pooled them as relative risk (RR) in a random-effect analysis. Only studies that reported events according to the number of times the ARC-HBR definition was met were included in a sensitivity analysis and RR for each stratum was calculated. Nine studies and 68,874 subjects were included in our analysis; 39.2% of them were at HBR and they had a significantly higher risk of major bleedings (RR: 2.70; 95% CI: 2.35-3.10; p < 0.0001). The ARC-HBR definition also had a moderate discriminative power (pooled c-stat: 0.69; 95% CI: 0.61-0.75) while calibration was suboptimal with a tendency toward underpredicting bleeding events (pooled observed:expected ratio: 1.47; 95% CI: 0.82-2.60). Our sensitivity analysis included 5 studies and 46,712 patients and confirmed the incremental, additive power of the ARC-HBR when it is met multiple times. Finally, among baseline characteristics explored, only presenting with an acute coronary syndrome had a significant impact on the ARC-HBR predictive ability. The ARC-HBR definition is a useful clinical tool, but with a tendency towards underpredicting major bleedings and its predictive ability might be optimized by including the number of times the definition is met.


Assuntos
Síndrome Coronariana Aguda , Intervenção Coronária Percutânea , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/epidemiologia , Síndrome Coronariana Aguda/cirurgia , Hemorragia/epidemiologia , Hemorragia/etiologia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Inibidores da Agregação Plaquetária , Fatores de Risco , Resultado do Tratamento
6.
Eur Heart J Acute Cardiovasc Care ; 11(6): 464-469, 2022 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-35524735

RESUMO

The effectiveness of transcatheter edge-to-edge repair (TEER) in patients with functional mitral regurgitation (FMR) and pulmonary hypertension (PH) is still debated and pre-procedural predictors of haemodynamic improvement after TEER in this setting are currently unknown. We investigated whether normalization of pulmonary artery wedge pressure (PAWP) in response to sodium nitroprusside (SNP) during baseline right heart catheterization might be predictive of a favourable haemodynamic response to MitraClip in patients with FMR and PH. Among 22 patients enrolled, 13 had a positive response to SNP (responders), nine were non-responders. At 6-months follow-up, responders showed a 33% reduction in PAWP and a 25% reduction in mean pulmonary artery pressure (PAP) (P = 0.002 and 0.004, respectively); no significant change occurred in non-responders. In patients with FMR and PH, pre-procedural vasodilator challenge with SNP may help define patients who may have haemodynamic improvement after TEER.


Assuntos
Hipertensão Pulmonar , Insuficiência da Valva Mitral , Cateterismo Cardíaco , Hemodinâmica/fisiologia , Humanos , Hipertensão Pulmonar/complicações , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento , Vasodilatadores/uso terapêutico
9.
Rev Cardiovasc Med ; 22(1): 33-38, 2021 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-33792246

RESUMO

Transcatheter mitral valve repair with MitraClip has emerged as a possible therapeutic option for patients with severe mitral regurgitation (MR) with high risk for surgical valve repair. MitraClip intervention has demonstrated to improve haemodynamics and clinical outcomes in selected patients in observational and randomized studies. Preoperative pulmonary hypertension (PH) is known to affect prognosis in patients undergoing surgical mitral valve intervention. The aim of the present review is to discuss the available literature focused on the haemodynamic and clinical effects of MitraClip in patients with severe MR and PH.


Assuntos
Implante de Prótese de Valva Cardíaca , Hipertensão Pulmonar , Insuficiência da Valva Mitral , Cateterismo Cardíaco/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hemodinâmica , Humanos , Hipertensão Pulmonar/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Prognóstico , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...