Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 89
Filtrar
1.
Am J Cardiol ; 218: 43-50, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38479607

RESUMO

Low-voltage areas have been used as atrial structural substrates in estimating fibrotic degeneration in patients with atrial fibrillation (AF). The high-resolution maps obtained by recently developed mapping catheters allow the visualization of several functional abnormalities. We investigated the association between left atrial (LA) functional abnormal findings on a high-resolution substrate map and AF recurrence in patients who underwent pulmonary vein isolation without any additional LA substrate ablation. This observational study included 100 consecutive patients who underwent second ablation for AF (paroxysmal, 48%; persistent, 52%). Patients with extra-pulmonary-vein LA substrate ablation during the initial and second ablation were excluded. LA mapping was performed using a 64-pole mini-basket catheter on the RHYTHMIA mapping system (Boston Scientific, Marlborough [Cambridge] Massachusetts). Patients were followed for 2 years. AF recurrence developed in 39 (39%) patients. On the high-resolution substrate map, AF recurrence was associated with the presence of the following findings: low-voltage areas (<1.0 mV, >5 cm2; hazard ratio [HR] = 2.53; 95% confidence interval [CI] = 1.30 to 4.93; p <0.006), fractionated-electrogram areas (≥5 peaks, >5 cm2; HR = 2.15, 95% CI = 1.10 to 4.19; p = 0.025), LA conduction time of >130 ms (HR = 3.11, 95% CI = 1.65 to 5.88, p <0.0001), deceleration zone (≥5 isochrones/cm2; HR = 1.97, 95% CI = 1.04 to 3.37, p = 0.039), and multiple septal break-out points (HR = 3.27, 95% CI = 1.50 to 7.16, p = 0.003). Accumulation of these risk factors increased AF recurrence in a stepwise manner, with an HR = 1.90, 95% CI = 1.44 to 2.52, p <0.00001 for each additional risk factor. In conclusion, a high-resolution map revealed new LA functional substrates associated with AF recurrence. Implementation of functional substrates may improve the prediction of AF recurrence after ablation, and possibly aid the development of tailored AF ablation strategies.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Átrios do Coração , Frequência Cardíaca , Fatores de Risco , Ablação por Cateter/efeitos adversos , Recidiva , Resultado do Tratamento
2.
J Cardiovasc Electrophysiol ; 35(4): 775-784, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38375957

RESUMO

INTRODUCTION: Left atrial low-voltage areas (LVAs) are known to be correlated with atrial scarring and atrial fibrillation (AF) recurrence after ablation. However, the association between LVAs and glycemic status before ablation has not been fully clarified. The purpose of this study was to investigate associations among the prevalence of diabetes mellitus (DM), glycemic control, and the prevalence of LVAs in patients with AF ablation. METHODS: In total, 912 (age, 68 ± 10 years; female, 299 [33%]; persistent AF, 513 [56%]) consecutive patients who underwent initial AF ablation were included. A preprocedure glycated hemoglobin A1c (HbA1c) ≥7% was set as the cutoff for poor glycemic control in patients with DM. LVAs were defined as areas with a bipolar voltage of <0.5 mV covering ≥5 cm2 of left atrium. RESULTS: LVAs existed in 208 (23%) patients, and 168 (18%) patients had DM. LVAs were found more frequently in patients with DM and poor glycemic control. On multivariate analysis, DM with HbA1c ≥7% was an independent predictor of LVAs (odds ratio, 3.3; 95% confidence interval: 1.6-6.7; p = .001). In patients with LVAs, freedom from AF recurrence during the 24-month study period was significantly lower in patients who had DM with HbA1c ≥7% than in those without DM (37.9% vs. 54.7%, p = .02). CONCLUSION: In patients with AF ablation, LVAs were found more frequently in patients with DM and poor glycemic control. DM with HbA1c ≥7% was an independent predictor of LVAs.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Diabetes Mellitus , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Prevalência , Hemoglobinas Glicadas , Controle Glicêmico , Átrios do Coração/cirurgia , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiologia , Diabetes Mellitus/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva , Resultado do Tratamento
3.
J Cardiovasc Electrophysiol ; 35(1): 171-181, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38018401

RESUMO

INTRODUCTION: Atrial fibrillation (AF) is accompanied by various types of remodeling, including volumetric enlargement and histological degeneration. Electrical remodeling reportedly reflects histological degeneration. PURPOSE: To clarify the differences in determinants and clinical impacts among types of remodeling. METHODS: This observational study included 1118 consecutive patients undergoing initial ablation for AF. Patients were divided into four groups: minimal remodeling (left atrial volume index [LAVI] < mean value and no low-voltage area [LVA], n = 477); volumetric remodeling (LAVI ≥ mean value and no LVA, n = 361); electrical remodeling (LAVI < mean value and LVA presence, n = 96); and combined remodeling (LAVI ≥ mean value and LVA presence, n = 184). AF recurrence and other clinical outcomes were followed up for 2 and 5 years, respectively. RESULTS: Major determinants of each remodeling pattern were high age for electrical (odds ratio = 2.32, 95% confidence interval = 1.68-3.25) and combined remodeling (2.57, 1.88-3.49); female for electrical (3.85, 2.21-6.71) and combined remodeling (4.92, 2.90-8.25); persistent AF for combined remodeling (7.09, 3.75-13.4); and heart failure for volumetric (1.71, 1.51-2.53) and combined remodeling (2.21, 1.30-3.75). Recurrence rate after initial ablation increased in the order of minimal remodeling (20.1%), volumetric (27.4%) or electrical remodeling (36.5%), and combined remodeling (50.0%, p < .0001). A composite endpoint of heart failure, stroke, and death occurred in the order of minimal (3.4%), volumetric (7.5%) or electrical (8.3%), and combined remodeling (15.2%, p < .0001). CONCLUSION: Volumetric, electrical, and combined remodeling were each associated with a unique patient background, and defined rhythm and other clinical outcomes.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Remodelamento Atrial , Insuficiência Cardíaca , Feminino , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Recidiva , Resultado do Tratamento , Masculino
4.
Pacing Clin Electrophysiol ; 47(1): 28-35, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38029377

RESUMO

BACKGROUND: Recently, a new OCTARAY® mapping catheter was commercially launched. The catheter is designed to enable high-density mapping and precise signal recording via 48 small electrodes arranged on eight radiating splines. The purpose of this study was to compare bipolar voltage and low-voltage-area size, and mapping efficacy between the OCTARAY catheter and the PENTARAY® catheter METHODS: Twelve consecutive patients who underwent initial and second ablations for persistent atrial fibrillation within 2 years were considered for enrollment. Voltage mapping was performed twice, first during the initial ablation using the PENTARY catheter and second during the second ablation using the OCTARAY Long 3-3-3-3-3 (L3) catheter. RESULTS: Mean voltage with the OCTARAY-L3 catheter (1.64 ± 0.57 mV) was 32.3% greater than that with the PENTARAY catheter (1.24 ± 0.46 mV, p < .0001) in total left atrium. Low-voltage-area (<0.50 mV) size with the OCTARAY-L3 catheter was smaller than that with the PENTARAY catheter (6.9 ± 9.7 vs. 11.4 ± 13.0 cm2 , p < .0001). The OCTARAY-L3 catheter demonstrated greater efficacy than the PENTARAY catheter in terms of shorter mapping time (606 ± 99 vs. 782 ± 211 s, p = .008) and more mapping points (3,026 ± 838 vs. 781 ± 342 points, p < .0001). CONCLUSION: The OCTARAY catheter demonstrated higher voltage recordings, narrower low-voltage areas, and a more efficacious mapping procedure than the PENTARAY catheter.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Técnicas Eletrofisiológicas Cardíacas , Ablação por Cateter/métodos , Fibrilação Atrial/cirurgia , Átrios do Coração , Catéteres
5.
Heart Rhythm ; 21(4): 378-386, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38157922

RESUMO

BACKGROUND: Atrial cardiomyopathy is known as an underlying pathophysiological factor in the majority of patients with atrial fibrillation (AF). Left atrial low-voltage areas (LVAs) are reported to coincide with fibrosis and likely represent atrial cardiomyopathy. OBJECTIVE: The purpose of this study was to delineate differences in the long-term prognosis of patients stratified by the size of LVAs. METHODS: This observational study included 1488 consecutive patients undergoing initial ablation for AF. LVAs were defined as regions with a bipolar peak-to-peak voltage <0.50 mV. The total study population was divided into 3 groups stratified by LVA size: patients with no LVAs (n = 1136); those with small (<20 cm2) LVAs (n = 250) LVAs; and those with extensive (≥20 cm2) LVAs (n = 102). Composite endpoints of death, heart failure, and stroke were followed for up to 5 years. RESULTS: Composite endpoints developed in 105 of 1488 patients (7.1%), and AF recurrence occurred in 410 (27.6%). Composite endpoints developed more frequently in the order of patients with extensive LVAs (19.1%), small LVAs (10.8%), and no LVAs (5.1%) (P for trend <.0001). Multivariable analysis revealed that LVA presence was independently associated with higher incidence of composite endpoints, irrespective of AF recurrence (modified hazard ratio 1.73; 95% confidence interval 1.13-2.64; P = .011) CONCLUSION: LVA presence and its extent both were associated with poor long-term composite endpoints of death, heart failure, and stroke, irrespective of AF recurrence or other confounders. Underlying atrial cardiomyopathy seems to define a poor prognosis after AF ablation.


Assuntos
Fibrilação Atrial , Cardiomiopatias , Ablação por Cateter , Insuficiência Cardíaca , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Prognóstico , Seguimentos , Átrios do Coração , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico , Ablação por Cateter/efeitos adversos , Recidiva
6.
J Endovasc Ther ; : 15266028231209234, 2023 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-37933462

RESUMO

PURPOSE: Despite widespread use of anti-restenosis devices, drug-coated balloons (DCBs) and drug-eluting stents (DESs), their appropriate use for femoropopliteal (FP) lesions has not been well investigated and the risk factors for restenosis have not been compared. To investigate risk factors associated with restenosis after endovascular therapy using DCB and DES for contemporary FP lesions. MATERIALS AND METHODS: This single-center, retrospective, observational study evaluated 378 FP lesions in 273 patients treated with DCB (278 lesions in 193 patients) or DES (120 lesions in 106 patients). The DCB used was high-dose DCB (IN.PACT, Admiral. Medtronic, Inc.) and DES was fluoropolymer-based DES (ELUVIA, Boston Scientific). Vessel preparation failure was defined as a residual stenosis of ≥50% and a dissection grade of D or greater on pre-dilatation angiography. The outcome measure was restenosis, and factors associated with restenosis in the DCB and DES groups were assessed using a Cox proportional hazards model. RESULTS: The 2-year restenosis rate was not significantly different between the DCB and DES groups (29%±4% vs. 24%±5%, p=0.42). Interaction analysis demonstrated that popliteal lesions and plaque burden of ≥50% were restenosis-related factors for DES but not for DCB, whereas vessel preparation failure was a factor for DCB but not for DES (p<0.05). Vessel diameter of <6 mm and nodular calcification were risk factors in both groups (p<0.05). CONCLUSION: In contemporary FP lesions, smaller vessels and nodular calcification were shared restenosis-related factors for high-dose DCB and fluoropolymer-based DES. Popliteal lesions and plaque burden of ≥50% were restenosis-related factors for fluoropolymer-based DES and vessel preparation failure for high-dose DCB. CLINICAL IMPACT: Shared and differential restenosis-related factors after endovascular therapy using high-dose drug-coated balloons (DCBs) and fluoropolymer-based drug-eluting stents (DESs) in contemporary femoropopliteal (FP) lesions are unclear. This single-center retrospective study included 378 FP lesions in 273 patients with lower-extremity arterial disease (high-dose DCB, 278 lesions in 193 patients; fluoropolymer-based DES, 120 lesions in 106 patients). Smaller vessels and calcified nodules were shared restenosis-related factors for both high-dose DCB and fluoropolymer-based DES, whereas popliteal lesions and plaque burden of ≥50% were restenosis-related factors for fluoropolymer-based DES and vessel preparation failure for high-dose DCB.

7.
Am J Cardiol ; 203: 37-44, 2023 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-37481810

RESUMO

Atrial myocardial degeneration predisposes to atrial fibrillation (AF), ischemic stroke, and heart failure. Studies suggest the presence of gender differences in atrial myocardial degeneration. This study aimed to delineate gender differences in the prevalence, predictors, and prognostic impact of left atrial low-voltage areas (LVAs). This observational study included 1,488 consecutive patients who underwent initial ablation for AF. Voltage mapping was performed after pulmonary vein isolation during sinus rhythm. LVAs were defined as regions where bipolar peak-to-peak voltage was <0.50 mV. LVA prevalence was higher in women (38.7%) than in men (16.0%). High age, persistent form of AF, diabetes mellitus, and a large left atrium were shown to be common predictors in both gender categories. Heart failure and history of stroke/thromboembolic events were men-specific predictors of LVA existence. Women experienced more AF recurrence than men (31.1% vs 25.7%, p = 0.027). LVA existence was significantly associated with increased AF recurrence in each gender category, with a respective hazard ratio, 95% confidence interval, and p value of 2.45, 1.87 to 3.22, and <0.0001 in men and 1.82, 1.33 to 2.49, and <0.0001 in women. In conclusion, LVA was more frequent in women than men, and predicted frequent AF recurrence irrespective of gender category.


Assuntos
Fibrilação Atrial , Cardiomiopatias , Ablação por Cateter , Insuficiência Cardíaca , Veias Pulmonares , Masculino , Humanos , Feminino , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Fatores Sexuais , Átrios do Coração , Fibrose , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
8.
J Cardiovasc Med (Hagerstown) ; 24(8): 544-551, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37161971

RESUMO

AIMS: Atrial natriuretic peptide (ANP) deficiency is thought to be one of the causes of heart failure induced by atrial fibrillation (AF). Although ANP deficiency is thought to occur as a result of atrial remodeling, data to explain this mechanism are limited. The purpose of this study was to investigate the association between ANP and left atrial remodeling or prognosis of heart failure in patients with AF ablation. METHODS: In total, 373 consecutive patients who underwent initial ablation for persistent AF [age, 67 ±â€Š10 years; female, 97 (26%)] were retrospectively enrolled. ANP and brain natriuretic peptide (BNP) were measured before the procedure and the ANP/BNP ratio was calculated. Left atrial volume index, left atrial appendage emptying velocity, and left atrial low-voltage areas (LVAs) were used as left atrial-remodeling parameters. The primary outcome of heart failure was defined as the composite of all-cause death or hospitalization due to worsening heart failure. RESULTS: The median ANP level was 116 (71-178) pg/ml and the median ANP/BNP ratio was 0.65 (0.46-1.00). The ANP/BNP ratio decreased with increasing left atrial volume index or LVAs and with decreasing left atrial appendage emptying velocity. During the 5-year follow-up, freedom from the primary outcome was significantly lower in patients with ANP/BNP ratio ≤0.65 than in those with ANP/BNP ratio >0.65 (84.6% versus 95.6%, P  < 0.01). CONCLUSION: Secretion of ANP relative to BNP decreased with progression of left atrial remodeling in patients with AF ablation. Furthermore, prognosis of heart failure was poor in patients with a low ANP/BNP ratio.


Assuntos
Fibrilação Atrial , Remodelamento Atrial , Insuficiência Cardíaca , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Fator Natriurético Atrial , Insuficiência Cardíaca/etiologia , Peptídeo Natriurético Encefálico , Estudos Retrospectivos , Masculino
9.
J Cardiol Cases ; 27(5): 241-244, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37180222

RESUMO

Deep brain stimulation (DBS) is a well-established therapy for drug-refractory Parkinson's disease. As 100-200 Hz signals from DBS are transmitted from the generator implanted subcutaneously in the anterior chest wall, there is a risk of central nervous system damage by radiofrequency energy or cardioversion. A 76-year-old female with a DBS was admitted for catheter ablation because of palpitation and syncope by paroxysmal atrial fibrillation. There may have been a risk of central nervous system damage and DBS electrode malfunction by radiofrequency energy and defibrillation shocks. In addition, cardioversion by an external defibrillator had the possibility to cause brain injury in patients with DBS. Therefore, pulmonary vein isolation by cryoballoon and cardioversion using an intracardiac defibrillation catheter were performed. Despite continued application of DBS during the procedure, no complications occurred. This is the first case report of cryoballoon ablation accompanied with intracardiac defibrillation under continued DBS. Cryoballoon ablation may be an alternative atrial fibrillation ablation method to radiofrequency catheter ablation for patients with DBS. Additionally, intracardiac defibrillation may reduce the risk of central nervous system damage and DBS malfunction. Learning objective: Deep brain stimulation (DBS) is a well-established therapy for Parkinson's disease. In patients with DBS, there is a risk of central nervous system damage by radiofrequency energy or cardioversion by an external defibrillator. Cryoballoon ablation may be an alternative atrial fibrillation ablation method to radiofrequency catheter ablation for patients with continued DBS. In addition, intracardiac defibrillation may reduce the risk of central nervous system damage and DBS malfunction.

10.
Circ J ; 87(3): 432-429, 2023 02 24.
Artigo em Inglês | MEDLINE | ID: mdl-36624062

RESUMO

BACKGROUND: Although favorable clinical outcomes have been demonstrated for fluoropolymer-based paclitaxel-eluting stents (FP-DES) in the treatment of femoropopliteal lesions, the vascular response after implantation has not been systematically studied through intravascular imaging.Methods and Results: We angioscopically compared FP-DES: 24 in the early phase (mean [±SD] 3±1 months), 26 in the middle phase (12±3 months), and 20 in the late phase (≥18 months) after implantation. The dominant neointimal coverage grade, heterogeneity of neointimal coverage grade, and thrombus adhesion in the stent segment were evaluated. Neointimal coverage was graded as follows: Grade 0, stent struts exposed; Grade 1, struts bulging into the lumen, although covered; Grade 2, struts embedded in the neointima, but visible; Grade 3, struts fully embedded and invisible. Dominant neointimal coverage and heterogeneity grades were significantly higher in the middle and late phases than in the early phase (all P<0.05), but did not differ significantly between the middle and late phases. The incidence of thrombus adhesion was recorded for all stents in each of the 3 different phases. CONCLUSIONS: The middle and late phases after FP-DES implantation were associated with significantly higher dominant neointimal coverage and heterogeneity grades than the early phase. However, thrombus adhesion was observed in all phases after FP-DES implantation. Arterial healing may not be completed even in the late phase after FP-DES implantation.


Assuntos
Stents Farmacológicos , Trombose , Humanos , Polímeros de Fluorcarboneto , Angioscopia/métodos , Artéria Femoral , Neointima/patologia , Trombose/patologia , Vasos Coronários/patologia , Resultado do Tratamento
11.
Circ J ; 87(3): 424-431, 2023 02 24.
Artigo em Inglês | MEDLINE | ID: mdl-36567110

RESUMO

BACKGROUND: Vessel preparation for endovascular treatment (EVT) is important but because the contributory factors for favorable outcomes are not yet known, we conducted the present study to elucidate the factors associated with sufficient vessel preparation for severely calcified femoropopliteal (FP) lesions.Methods and Results: This was a single-center retrospective observational study of 97 patients (mean age, 75±8 years, 76% male) with 106 de novo severely calcified FP lesions who underwent EVT under intravascular ultrasound (IVUS) evaluation. The lesion definition was 360° of superficial calcification on IVUS. The primary outcome measure was sufficient vessel preparation, which was defined as successful cracking of severely calcified lesions evaluated by IVUS after predilation. The mean lesion length was 200±103 mm, and chronic total occlusion was present in 38% of patients. According to the greater difference between the preballoon size and the lumen diameter of the severely calcified lesion, the frequency of sufficient vessel preparation increased (odds ratio, 4.68; 95% confidence interval, 2.09-10.49; P<0.01). Balloon type (noncompliant, P=0.80; scoring: P=0.25) and pressure (P=0.27) were non-contributory. CONCLUSIONS: The difference between the lumen diameter at the severely calcified FP lesion site and the preballoon dilatation diameter was the sole factor contributing to sufficient vessel preparation.


Assuntos
Angioplastia com Balão , Doença Arterial Periférica , Humanos , Masculino , Idoso , Idoso de 80 Anos ou mais , Feminino , Stents , Resultado do Tratamento , Artéria Femoral , Artéria Poplítea , Doença Arterial Periférica/terapia
12.
Heart Vessels ; 38(4): 497-506, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36454300

RESUMO

Although the superiority of DCBs to uncoated balloon angioplasty for the treatment of femoropopliteal (FP) lesions has been demonstrated, the association of clinical factors, including anatomical features evaluated by intravascular ultrasound (IVUS) and platelet reactivity, with the loss of patency has not been systematically studied. The current prospective, observational study enrolled 160 consecutive patients (male 67.5%, mean age 74.7 ± 9.7 years) with 213 FP lesions treated with DCBs under IVUS evaluation. The platelet reactivity was measured in P2Y12 reaction units for all of the patients at the DCB treatment. The primary end point was primary patency at 12 months, while the secondary end points were freedom from target lesion revascularization (TLR), all-cause death, major target limb amputation and bleeding events at 12 months. Mean lesion length was 11.9 ± 9.4 cm and 34 (16.0%) were chronic total occlusions (CTOs). Thirty-four (16.0%) were severely calcified lesions. Primary patency by Kaplan-Meier estimate was 79.2% at 12 months, while the 12-month freedom from TLR, all-cause death and bleeding events were observed in 89.1%, 93.4% and 97.4%, respectively. There were no major target limb amputations through 12 months. Multivariate analysis showed that subintimal angioplasty for CTO lesions was a sole risk factor for loss of 12-month primary patency, while other IVUS parameters and platelet reactivity were not.


Assuntos
Angioplastia com Balão , Doença Arterial Periférica , Humanos , Masculino , Idoso , Idoso de 80 Anos ou mais , Artéria Poplítea/diagnóstico por imagem , Doença Arterial Periférica/cirurgia , Resultado do Tratamento , Materiais Revestidos Biocompatíveis , Grau de Desobstrução Vascular , Fatores de Tempo , Artéria Femoral/diagnóstico por imagem , Angioplastia com Balão/efeitos adversos , Ultrassonografia de Intervenção
13.
J Endovasc Ther ; 30(2): 269-280, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-35249409

RESUMO

PURPOSE: Although the size of drug-coated balloons (DCBs) is determined according to the vessel diameter during femoropopliteal (FP)-endovascular therapy (EVT), the measurements of the vessel diameter vary among modalities and its definitions. The aim of this study was to reveal whether the DCB size fitting (1) angiographically-measured lumen diameter (Angio-lumen size), (2) intravascular ultrasound (IVUS)-measured lumen diameter (IVUS-lumen size), or (3) IVUS-measured external elastic membrane (EEM) diameter (IVUS-EEM size) would be beneficial in restenosis occurrence. MATERIALS AND METHODS: This retrospective, single-center study included 231 de novo FP lesions in 165 patients with peripheral artery disease treated with IN.PACT Admiral DCB under IVUS evaluation. The reference vessel diameter was evaluated as the lumen or EEM diameter at the healthy site distal to the lesion. We retrospectively determined whether the DCB size was close to (ie, equal to or different by <0.5 mm from) Angio-lumen size, IVUS-lumen size, and IVUS-EEM size. The association of the size of DCB with restenosis risk was investigated. RESULTS: The mean lesion length was 13 ± 9 cm and the prevalence of chronic total occlusion was 18%. During a mean follow-up period of 17 ± 9 months, restenosis occurred in 26% of lesions. Lesions treated with a DCB of IVUS-EEM size had a lower 2 year restenosis rate than those treated with a DCB over/under IVUS-EEM size (19.7 ± 5.7% vs 34.5 ± 4.7%, p=0.02 by the log-rank test), while the restenosis rate was not significantly different between DCBs of Angio-lumen size or IVUS-lumen size and those over/under the size (both p>0.05). The multivariate Cox regression analysis revealed that DCBs of IVUS-EEM size were independently associated with a reduced risk of restenosis (adjusted hazard ratio 0.50; 95% confidence interval 0.27-0.95; p=0.03). CONCLUSION: The DCBs of IVUS-EEM size, but not of Angio-lumen size or IVUS-lumen size, were associated with a reduced risk of restenosis after FP-EVT. Determining the DCB size according to IVUS-evaluated EEM diameter would be potentially beneficial in restenosis occurrence.


Assuntos
Angioplastia com Balão , Doença Arterial Periférica , Humanos , Artéria Poplítea/diagnóstico por imagem , Estudos Retrospectivos , Angioplastia com Balão/efeitos adversos , Resultado do Tratamento , Artéria Femoral/diagnóstico por imagem , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/terapia , Materiais Revestidos Biocompatíveis , Grau de Desobstrução Vascular
14.
Circ Rep ; 4(10): 461-468, 2022 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-36304430

RESUMO

Background: Decompensated heart failure (DHF) can complicate catheter ablation for atrial fibrillation (AF). We investigated the association between heart rate and DHF in AF patients undergoing catheter ablation. Methods and Results: In all, 1,004 consecutive patients who underwent initial ablation for AF (mean [±SD] age 68±10 years; 34% female; persistent AF n=513 [51%]) were enrolled in the study. Heart rate was assessed before and after ablation. DHF was defined as heart failure requiring medical therapy within 2 days after the procedure. The incidence of DHF was 2% (22 of 1,004 patients). Patients with DHF had a higher prevalence of a history of symptomatic heart failure (11/22 [50%] vs. 160/982 [16%]; P<0.0001) and a greater degree of heart rate decrease after the procedure (-21±29 vs. 2±21 beats/min; P=0.001) than those without DHF. On multivariate analysis, heart rate decrease was a significant independent predictor of DHF (hazard ratio 0.8; 95% confidence interval 0.7-0.9; P=0.004; 10 beats/min-increment). Conclusions: In patients undergoing AF ablation, a decrease in heart rate after the procedure was an independent predictor of DHF.

15.
J Cardiovasc Electrophysiol ; 33(8): 1697-1704, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35748348

RESUMO

BACKGROUND: Very late recurrence of atrial fibrillation (VLRAF) occurring >1 year after catheter ablation may influence long-term follow-up strategies, including oral anticoagulant therapy. However, little is known about the predictors of this condition. Given that the prevalence of left atrial low-voltage areas (LVAs) is strongly associated with the recurrence of atrial tachyarrhythmias following catheter ablation, we hypothesized that VLRAF might occur more frequently in patients with LVAs at the time of initial ablation. The purpose of this study was to investigate the impact of LVAs on VLRAF. METHODS: This study included 1001 consecutive patients undergoing initial ablation procedures for AF. LVAs were defined as regions with bipolar peak-to-peak voltages of <0.50 mV on the voltage map obtained during sinus rhythm after pulmonary vein isolation. During a 1-year follow-up period, 248 patients had a late recurrence of AF (LRAF), defined as recurrence within 3-12 months after ablation. The occurrence of VLRAF was examined in 711 patients without LRAF who were followed for more than 1 year. RESULTS: A total of 711 patients who did not develop AF recurrence within 1 year and for whom clinical data were available after 1 year were analyzed. During a median follow-up of 25 (19, 37) months, VLRAF more than 1 year after the initial ablation was detected in 123 patients. On multivariate analysis, independent predictors of VLRAF were the existence of LVAs, female, left atrial diameter and early recurrence of AF. A Kaplan-Meier analysis showed that the AF-free survival rate was significantly lower in patients with LVAs than in those without LVAs within 1 year and on more than 1-year follow-up (p < .001). An additional Kaplan-Meier analysis of the incidence of VLRAF in propensity score-matched patients with and without LVAs showed that VLRAF occurred significantly more frequently in patients with LVAs (p = .003). CONCLUSIONS: LVAs during the initial AF ablation procedures have an impact on VLRAF occurrence.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Feminino , Humanos , Veias Pulmonares/cirurgia , Recidiva , Fatores de Tempo , Resultado do Tratamento
16.
Heart Vessels ; 37(11): 1957-1961, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35612597

RESUMO

Although the global vascular guidelines recently proposed the Global Limb Anatomic Staging System (GLASS) as an anatomical classification for chronic limb-threatening ischaemia (CLTI), prediction of perioperative outcomes using the GLASS classification in patients with CLTI due to isolated below-the-knee (BTK) lesions has not been well studied.This retrospective study included 585 patients with CLTI due to isolated BTK lesions who underwent endovascular therapy (EVT). The severity of arterial lesions was graded using the GLASS infrapopliteal (IP) and inframalleolar (IM) classifications and defined as follows: non-severe IP, 0-3; severe IP, 4; non-severe IM, P0-1; and severe IM, P2. The outcome measures were technical failure, defined as recanalisation failure of the target artery path, and perioperative failure, defined as a composite of all-cause death, major amputation, or repeat revascularisation within 30 days.Technical and perioperative failures occurred in 9.4% (n = 55) and 9.9% (n = 58) patients, respectively. Compared to patients with non-severe IP and IM, those with both severe IP and IM were significantly associated with technical and perioperative failures (odds ratio [OR]: 13.87 [95% confidence interval (CI) 4.69-41.02, P < 0.001] and OR: 2.18 [95% CI 1.08-4.38, P = 0.041], respectively).The GLASS classification may have predictive value for technical and perioperative failure in patients with CLTI due to isolated BTK lesions after EVT.


Assuntos
Procedimentos Endovasculares , Doença Arterial Periférica , Amputação Cirúrgica , Doença Crônica , Isquemia Crônica Crítica de Membro , Procedimentos Endovasculares/efeitos adversos , Humanos , Isquemia/etiologia , Isquemia/cirurgia , Salvamento de Membro , Doença Arterial Periférica/complicações , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/cirurgia , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
17.
ESC Heart Fail ; 9(3): 1901-1913, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35293159

RESUMO

AIMS: The purpose of this study was to compare the impact of catheter ablation on cardiac structural reverse remodelling and atrial (AFMR) and ventricular (VFMR) functional mitral regurgitation (MR), and the long-term prognosis of patients with AFMR and VFMR. METHODS AND RESULTS: The retrospective study included persistent AF patients who had AFMR (n = 136, left atrial (LA) volume index >30 mL/m2 and left ventricular (LV) ejection fraction ≥40%) or VFMR (n = 31, LV ejection fraction <40% or LV regional asynergy) and had undergone the initial AF ablation from April 2015 to December 2019. Baseline and 6 month follow-up echocardiography were performed to assess MR, LA, and LV sizes. MR improvement after ablation was comparable in the AFMR (64%) and VFMR groups (52%, P = 0.20). Patients with AFMR improvement showed a greater decrease in left atrial volume after ablation than those without (amount of change: -11.4 ± 15.1 vs. -2.3 ± 21.1 mL/m2 , P = 0.01). Patients with VFMR improvement showed a greater increase in LV ejection fraction than those without (amount of change: 28.5 ± 13.6% vs. 9.0 ± 14.8%, P = 0.001). The composite endpoint of all-cause death and heart failure hospitalization during the 2 year follow-up period was more frequently observed in the VFMR than in the AFMR group (22.6% vs. 3.7%, P < 0.0001). Patients with MR improvement after catheter ablation less frequently demonstrated the composite endpoint than those without (1.9% vs. 15.6%, P < 0.0001). CONCLUSIONS: Atrial functional mitral regurgitation and VFMR improvement after ablation were associated with atrial and ventricular reverse remodelling, respectively. It is possible that long-term prognosis is better in patients with AFMR than with VFMR, and in those with MR improvement than in those without.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência da Valva Mitral , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Átrios do Coração , Humanos , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Remodelação Ventricular
18.
Circ J ; 86(2): 192-199, 2022 01 25.
Artigo em Inglês | MEDLINE | ID: mdl-34707070

RESUMO

BACKGROUND: The efficacy of ablation targeting low-voltage areas (LVAs) is controversial, although LVA presence is well known to be associated with atrial fibrillation (AF) recurrence after ablation. AF substrate may not localize within LVAs.Methods and Results:This observational study enrolled 405 consecutive patients who underwent an initial AF ablation procedure. The left atrial (LA) voltage map was obtained after pulmonary vein isolation. LVAs were defined as areas with voltage <0.5 mV. To estimate whole LA electrophysiological degeneration, mean regional voltage at each of the 6 regions and LA total conduction velocity were measured. LVAs existed in 143 of 405 (35.3%) patients. Patients with LVAs demonstrated lower mean regional voltages throughout all 6 regions compared to those without LVAs (1.3 [1.8, 0.8] vs. 0.6 [1.0, 0.2] mV for the anterior wall, P<0.001). In contrast, LA conduction velocity was lower in patients with LVAs than in those without (0.89 [1.01, 0.74] vs. 0.93 [1.03, 0.87] m/s, P<0.001). Multivariate analysis revealed that low LA total conduction velocity and a higher number of regions with mean voltage reduction were independently associated with AF recurrence, although LVA presence was not. CONCLUSIONS: Patients with localized LA LVAs were characterized by whole LA electrophysiological degeneration as assessed by mean regional voltage and conduction velocity. In addition, whole LA electrophysiological degeneration parameters were well associated with AF recurrence.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Potenciais de Ação , Fibrilação Atrial/cirurgia , Função do Átrio Esquerdo/fisiologia , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas , Átrios do Coração , Humanos , Recidiva
19.
J Interv Card Electrophysiol ; 64(2): 427-435, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34382152

RESUMO

BACKGROUND: The search for a less invasive and lower cost cryoballoon-based strategy for atrial fibrillation (AF) ablation has resulted in a simplified procedure that may be suitable for cryoballoon ablation (CBA). Here, we compared procedural characteristics and outcomes between conventional CBA and simple CBA. METHODS: We enrolled 628 consecutive patients who underwent initial CBA for AF (age, 69 ± 12 years; female, 263 (42%); paroxysmal AF, 576 (92%); CHA2DS2-VASc score, 2.7 ± 1.6 points). Simple CBA was characterized by the minimal procedure required to isolate pulmonary veins, including the following: (1) CBA was performed without guidance from a 3-D mapping system; (2) a coronary sinus electrode and esophageal temperature probe were not used; (3) a waiting period after pulmonary vein isolation was not set; and AF induction by isoproterenol and atrial burst stimuli were not performed. RESULTS: Simple CBA was performed in 240 (38%) patients. Procedural time (49 ± 18 versus 85 ± 27 min, p < 0.01) was shorter, and total procedural costs (20,699 ± 8,091 versus 30,350 ± 11,647 US dollars, p < 0.01) were lower with simple CBA than conventional CBA. Freedom from AF recurrence during the 12-month study period (79.8% versus 78.4%, p = 0.52) and complication rate (8.8% versus 13.1%, p = 0.09) were similar between the two groups. CONCLUSION: Compared with conventional CBA, simple CBA reduced procedural time and procedural costs while providing comparable outcomes.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia/métodos , Feminino , Humanos , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
20.
Circ J ; 86(2): 245-252, 2022 01 25.
Artigo em Inglês | MEDLINE | ID: mdl-34321377

RESUMO

BACKGROUND: The randomized controlled VOLCANO trial demonstrated comparable 1-year rhythm outcomes between patients with and without ablation targeting low-voltage areas (LVAs) in addition to pulmonary vein isolation among paroxysmal atrial fibrillation (PAF) patients with LVAsMethods and Results:An extended-follow-up study of 402 patients enrolled in the VOLCANO trial with PAF, divided into 4 groups based on the results of voltage mapping: group A, no LVA (n=336); group B, LVA ablation (n=30); group C, LVA without ablation (n=32); and group D, incomplete voltage map (n=4). At 25 (23, 31) months after the initial ablation, AF/atrial tachycardia (AT) recurrence rates were 19% in group A, 57% in group B, 59% in group C, and 100% in group D. Recurrence rates were higher in patients with LVAs than in those without (group A vs. B+C, P<0.0001), and were comparable between those with and without LVA ablation (group B vs. C, P=0.83). Among patients who underwent repeat ablation, ATs were more frequently observed in patients with LVAs (Group B+C, 50% vs. A, 14%, P<0.0001). In addition, LVA ablation increased the incidence of AT development (group B, 71% vs. C, 32%, P<0.0001). CONCLUSIONS: Patients with LVAs demonstrated poor long-term rhythm outcomes irrespective of LVA ablation. ATs were frequently observed in patients with LVAs, and LVA ablation might exacerbate the occurrence of iatrogenic ATs.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Taquicardia Supraventricular , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Seguimentos , Átrios do Coração , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...