Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Environ Int ; 172: 107744, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36696793

RESUMO

The 2017-2019 hourly particle number size distributions (PNSD) from 26 sites in Europe and 1 in the US were evaluated focusing on 16 urban background (UB) and 6 traffic (TR) sites in the framework of Research Infrastructures services reinforcing air quality monitoring capacities in European URBAN & industrial areaS (RI-URBANS) project. The main objective was to describe the phenomenology of urban ultrafine particles (UFP) in Europe with a significant air quality focus. The varying lower size detection limits made it difficult to compare PN concentrations (PNC), particularly PN10-25, from different cities. PNCs follow a TR > UB > Suburban (SUB) order. PNC and Black Carbon (BC) progressively increase from Northern Europe to Southern Europe and from Western to Eastern Europe. At the UB sites, typical traffic rush hour PNC peaks are evident, many also showing midday-morning PNC peaks anti-correlated with BC. These peaks result from increased PN10-25, suggesting significant PNC contributions from nucleation, fumigation and shipping. Site types to be identified by daily and seasonal PNC and BC patterns are: (i) PNC mainly driven by traffic emissions, with marked correlations with BC on different time scales; (ii) marked midday/morning PNC peaks and a seasonal anti-correlation with PNC/BC; (iii) both traffic peaks and midday peaks without marked seasonal patterns. Groups (ii) and (iii) included cities with high insolation. PNC, especially PN25-800, was positively correlated with BC, NO2, CO and PM for several sites. The variable correlation of PNSD with different urban pollutants demonstrates that these do not reflect the variability of UFP in urban environments. Specific monitoring of PNSD is needed if nanoparticles and their associated health impacts are to be assessed. Implementation of the CEN-ACTRIS recommendations for PNSD measurements would provide comparable measurements, and measurements of <10 nm PNC are needed for full evaluation of the health effects of this size fraction.


Assuntos
Poluentes Atmosféricos , Poluição do Ar , Material Particulado/análise , Poluentes Atmosféricos/análise , Emissões de Veículos/análise , Tamanho da Partícula , Monitoramento Ambiental , Poluição do Ar/análise , Europa (Continente) , Cidades , Fuligem
2.
Gesundheitswesen ; 84(7): 566-574, 2022 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-35835094

RESUMO

The relevance of aerosols for the transmission of the Severe Acute Respiratory Syndrome Coronavirus Type 2 (SARS-CoV-2) is still debated. However, over time, in addition to distancing and hygiene rules, aerosol physics-based measures such as wearing face masks and ventilating indoor spaces were found to be efficient in reducing infections. In an interdisciplinary workshop "Aerosol & SARS-CoV-2" of the Association for Aerosol Research (GAeF) in cooperation with the German Society for Pneumology and Respiratory Medicine (DGP), the Professional Association of General Air Technology of the VDMA, the German Society for Virology (GfV), the Health Technology Society (GG) and the International Society for Aerosols in Medicine (ISAM) under the auspices of the Robert Koch Institute (RKI) in March 2021, the need for research and coordination on this topic was addressed. Fundamental findings from the various disciplines as well as interdisciplinary perspectives on aerosol transmission of SARS-CoV-2 and infection mitigation measures are summarized here. Finally, open research questions and needs are presented.


Assuntos
COVID-19 , Aerossóis , COVID-19/prevenção & controle , Alemanha , Humanos , Máscaras , SARS-CoV-2
3.
Nat Nanotechnol ; 15(9): 731-742, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32807878

RESUMO

Nanotechnology is identified as a key enabling technology due to its potential to contribute to economic growth and societal well-being across industrial sectors. Sustainable nanotechnology requires a scientifically based and proportionate risk governance structure to support innovation, including a robust framework for environmental risk assessment (ERA) that ideally builds on methods established for conventional chemicals to ensure alignment and avoid duplication. Exposure assessment developed as a tiered approach is equally beneficial to nano-specific ERA as for other classes of chemicals. Here we present the developing knowledge, practical considerations and key principles need to support exposure assessment for engineered nanomaterials for regulatory and research applications.


Assuntos
Exposição Ambiental/efeitos adversos , Nanoestruturas/química , Nanoestruturas/toxicidade , Nanotecnologia/métodos , Medição de Risco/métodos , Disponibilidade Biológica , Exposição Ambiental/prevenção & controle , Humanos , Termodinâmica
4.
Clin Oral Investig ; 24(7): 2403-2414, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31811493

RESUMO

OBJECTIVE: To evaluate the collection efficiency of water spray on the release of airborne composite particles during grinding of composite materials. MATERIALS AND METHODS: Composite sticks (L:35 mm × W:5.4 mm × H:1.6 mm) of seven commercial dental composites were ground with a rough diamond bur (grain size 100 µm, speed 200,000 rpm). All experiments were performed in an enclosed 1-m3 chamber with low particulate background (< 1,000 #/cm3), and airborne particles were evaluated based on their electrical mobility. The number size distribution was determined by scanning mobility particle sizer (SMPS). Particles were collected by an electrostatic precipitator (ESP), and were ultramorphologically and chemically analyzed by a transmission electron microscope equipped with energy-dispersive X-ray spectroscopy (TEM-EDS). RESULTS: SMPS measurements confirmed that both dry and wet grinding generated high concentrations of nanoparticles particles with the highest concentration recorded during the last minute of grinding (1.80 × 106 - 3.29 × 106#/cm3), after which a gradual decline in particle concentration took place. Nevertheless, grinding with water spray resulted in a significant reduction of the number of released particles (5.6 × 105 - 1.37 × 106#/cm3). The smallest particle diameter was recorded during the last minute of grinding followed by a continuous growth for every next measurement. TEM of composite dust revealed a high concentration of particles varying in both size and shape. CONCLUSIONS: Regardless of whether the water cooling spray system was used during bur manipulation of composite materials, predominately nanoparticles were released. However, the particle concentrations were significantly decreased with water spray. CLINICAL RELEVANCE: Since water spray might not be sufficient in nanoparticle collection, special care should be taken to prevent inhalation of composite dust.


Assuntos
Poeira , Nanopartículas , Tamanho da Partícula , Água
5.
Sci Total Environ ; 627: 689-702, 2018 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-29426194

RESUMO

Exposure assessment is a key stage in the risk assessment/management of engineered nanomaterials. Although different sampling strategies and instruments have been used to define the occupational exposure to nano-scale materials, currently there is no international consensus regarding measurement strategy, metrics and limit values. In fact, the assessment of individual exposure to engineered nanomaterials remains a critical issue despite recent innovative developments in personal monitors and samplers. Hence, we used several of these instruments to evaluate the workers' personal exposure in a large research laboratory where engineered nanomaterials are produced, handled, and characterized in order to provide input data for nanomaterial exposure assessment strategies and future epidemiological studies. The results obtained using personal monitors showed that the workplace concentrations of engineered nanomaterials (lung deposited surface area and particle number concentrations) were quite low in all the different workplaces monitored, with short spikes during the execution of some specific job tasks. The sampling strategy was been adopted on the basis of an Organisation for Economic Cooperation and Development (OECD) suggestion for a tiered approach and was found to be suitable for determining the individual exposure and for identifying possible sources of emission, even those with very low emission rates. The use of these instruments may lead to a significant improvement not only in the exposure assessment stage but, more generally, in the entire risk assessment and management process.


Assuntos
Poluentes Ocupacionais do Ar/análise , Monitoramento Ambiental , Exposição por Inalação/análise , Nanoestruturas/análise , Exposição Ocupacional/análise , Humanos , Exposição por Inalação/estatística & dados numéricos , Exposição Ocupacional/estatística & dados numéricos , Local de Trabalho
6.
Sci Total Environ ; 605-606: 929-945, 2017 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-28688352

RESUMO

Personal monitors based on unipolar diffusion charging (miniDiSC/DiSCmini, NanoTracer, Partector) can be used to assess the individual exposure to nanoparticles in different environments. The charge acquired by the aerosol particles is nearly proportional to the particle diameter and, by coincidence, also nearly proportional to the alveolar lung-deposited surface area (LDSA), the metric reported by all three instruments. In addition, the miniDiSC/DiSCmini and the NanoTracer report particle number concentration and mean particle size. In view of their use for personal exposure studies, the comparability of these personal monitors was assessed in two measurement campaigns. Altogether 29 different polydisperse test aerosols were generated during the two campaigns, covering a large range of particle sizes, morphologies and concentrations. The data provided by the personal monitors were compared with those obtained from reference instruments: a scanning mobility particle sizer (SMPS) for LDSA and mean particle size and a ultrafine particle counter (UCPC) for number concentration. The results indicated that the LDSA concentrations and the mean particle sizes provided by all investigated instruments in this study were in the order of ±30% of the reference value obtained from the SMPS when the particle sizes of the test aerosols generated were within 20-400nm and the instruments were properly calibrated. Particle size, morphology and concentration did not have a major effect within the aforementioned limits. The comparability of the number concentrations was found to be slightly worse and in the range of ±50% of the reference value obtained from the UCPC. In addition, a minor effect of the particle morphology on the number concentration measurements was observed. The presence of particles >400nm can drastically bias the measurement results of all instruments and all metrics determined.


Assuntos
Poluentes Ocupacionais do Ar/análise , Monitoramento Ambiental/instrumentação , Nanopartículas/análise , Exposição Ocupacional/análise , Dispositivos Eletrônicos Vestíveis , Aerossóis , Humanos , Tamanho da Partícula , Local de Trabalho
7.
Sci Total Environ ; 603-604: 793-806, 2017 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-28431758

RESUMO

Exposure to airborne agents needs to be assessed in the personal breathing zone by the use of personal measurement equipment. Specific measurement devices for assessing personal exposure to airborne nanomaterials have only become available in the recent years. They can be differentiated into direct-reading personal monitors and personal samplers that collect the airborne nanomaterials for subsequent analyses. This article presents a review of the available personal monitors and samplers and summarizes the available literature regarding their accuracy, comparability and field applicability. Due to the novelty of the instruments, the number of published studies is still relatively low. Where applicable, literature data is therefore complemented with published and unpublished results from the recently finished nanoIndEx project. The presented data show that the samplers and monitors are robust and ready for field use with sufficient accuracy and comparability. However, several limitations apply, e.g. regarding the particle size range of the personal monitors and their in general lower accuracy and comparability compared with their stationary counterparts. The decision whether a personal monitor or a personal sampler shall be preferred depends strongly on the question to tackle. In many cases, a combination of a personal monitor and a personal sampler may be the best choice to obtain conclusive results.


Assuntos
Poluentes Ocupacionais do Ar/análise , Monitoramento Ambiental , Exposição por Inalação/análise , Nanoestruturas/análise , Exposição Ocupacional/análise , Humanos , Tamanho da Partícula , Local de Trabalho
8.
Dent Mater ; 32(12): 1482-1491, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27726967

RESUMO

INTRODUCTION: Previous research revealed that during routine abrasive procedures like polishing, shaping or removing of composites, high amounts of respirable dust particles (<5µm) including nano-sized particles (<100nm) may be released. OBJECTIVE: To determine the cytotoxic potential of composite dust particles on bronchial epithelium cells. METHODS: Composite dust of five commercial composites (one nano-composite, two nano-hybrid and two hybrid composites) was generated following a clinically relevant protocol. Polymerized composite samples were cut with a rough diamond bur (grain size 100µm, speed 200,000rpm) and all composite dust was collected in a sterile chamber. Human bronchial epithelial cells (16HBE14o-) were exposed to serially diluted suspensions of composite dust in cell culture medium at concentrations between 1.1 and 3.3mg/ml. After 24h-exposure, cell viability and membrane integrity were assessed by the WST-1 and the LDH leakage assay, respectively. The release of IL-1ß and IL-6 was evaluated. The composite dust particles were characterized by transmission electron microscopy and by dynamic and electrophoretic light scattering. RESULTS: Neither membrane damage nor release of IL-1ß was detected over the complete concentration range. However, metabolic activity gradually declined for concentrations higher than 660µg/ml and the release of IL-6 was reduced when cells were exposed to the highest concentrations of dust. SIGNIFICANCE: Composite dust prepared by conventional dental abrasion methods only affected human bronchial epithelial cells in very high concentrations.


Assuntos
Resinas Compostas/toxicidade , Poeira , Células Epiteliais/efeitos dos fármacos , Membrana Celular/efeitos dos fármacos , Células Epiteliais/metabolismo , Humanos , Interleucina-1beta/metabolismo , Interleucina-6 , Pulmão/citologia , Tamanho da Partícula
9.
Ann Occup Hyg ; 56(5): 606-21, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22752099

RESUMO

Five different portable instrument types to monitor exposure to nanoparticles were subject to an intensive intercomparison measurement campaign. Four of them were based on electrical diffusion charging to determine the number concentration or lung deposited surface area (LDSA) concentration of airborne particles. Three out of these four also determined the mean particle size. The fifth instrument type was a handheld condensation particle counter (CPC). The instruments were challenged with three different log-normally distributed test aerosols with modal diameters between 30 and 180 nm, varying in particle concentration and morphology. The CPCs showed the highest comparability with deviations on the order of only ±5%, independent of the particle sizes, but with a strictly limited upper number concentration. The diffusion charger-based instruments showed comparability on the order of ±30% for number concentration, LDSA concentration, and mean particle size, when the specified particle size range of the instruments matched the size range of the aerosol particles, whereas significant deviations were found when a large amount of particles exceeded the upper or lower detection limit. In one case the reported number concentration was even increased by a factor of 6.9 when the modal diameter of the test aerosol exceeded the specified upper limit of the instrument. A general dependence of the measurement accuracy of all devices on particle morphology was not detected.


Assuntos
Poluentes Ocupacionais do Ar/análise , Monitoramento Ambiental/instrumentação , Exposição por Inalação/análise , Teste de Materiais/estatística & dados numéricos , Nanopartículas/análise , Tamanho da Partícula , Aerossóis/análise , Calibragem , Ácidos Decanoicos/análise , Monitoramento Ambiental/métodos , Monitoramento Ambiental/normas , Humanos , Limite de Detecção , Pulmão/fisiologia , Teste de Materiais/métodos , Modelos Biológicos , Exposição Ocupacional/análise , Análise de Regressão , Cloreto de Sódio/análise , Fuligem/análise
10.
Part Fibre Toxicol ; 8: 22, 2011 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-21794132

RESUMO

Risk, associated with nanomaterial use, is determined by exposure and hazard potential of these materials. Both topics cannot be evaluated absolutely independently. Realistic dose concentrations should be tested based on stringent exposure assessments for the corresponding nanomaterial taking into account also the environmental and product matrix. This review focuses on current available information from peer reviewed publications related to airborne nanomaterial exposure. Two approaches to derive realistic exposure values are differentiated and independently presented; those based on workplace measurements and the others based on simulations in laboratories. An assessment of the current available workplace measurement data using a matrix, which is related to nanomaterials and work processes, shows, that data are available on the likelihood of release and possible exposure. Laboratory studies are seen as an important complementary source of information on particle release processes and hence for possible exposure. In both cases, whether workplace measurements or laboratories studies, the issue of background particles is a major problem. From this review, major areas for future activities and focal points are identified.


Assuntos
Poluentes Ocupacionais do Ar/análise , Nanopartículas/análise , Exposição Ocupacional , Poluentes Ocupacionais do Ar/toxicidade , Humanos , Nanopartículas/toxicidade , Exposição Ocupacional/efeitos adversos , Exposição Ocupacional/análise , Tamanho da Partícula , Fatores de Tempo , Local de Trabalho/normas
11.
J Environ Monit ; 7(9): 877-82, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16121267

RESUMO

A Gas Particle Partitioner (GPP) that allows highly efficient separation of gas and particles with no effect on the thermodynamic conditions and substantially no change of the gas composition has been developed. The GPP is a coaxial arrangement with inner and outer electrodes and utilizes a corona discharge to electrically charge the particles and a strong electric field to remove them from the sample flow. Several measures were taken to avoid an influence of the corona discharge on the gas composition. The GPP can be applied for various applications. This paper focuses on the use of the GPP as a pre-filter for gas analyzers, where zero pressure drop and a minimization of the influence of the corona discharge on the gas composition are the main objective. Due to its design, the GPP introduces no changes to the thermodynamic conditions. However, corona discharge is known to produce significant amounts of ozone and oxides of nitrogen. The effect of the corona on the gas composition of the sample flow was determined under various conditions. The gas concentrations strongly depended on several aspects, such as material and diameter of the corona wire and polarity of the corona voltage. Due to the measures taken to minimize an effect on the gas composition, the concentrations of these gases could effectively be reduced. Along with the maximum gas-particle separation efficiency of near 100%, the additional O3 concentration was 42 ppbV and the additional NO2 concentration 15 ppbV. If an efficiency of 95% is acceptable, the added concentrations can be as low as 2.5 ppbV (O3) and 0.5 ppbV (NO2), respectively.


Assuntos
Poluentes Atmosféricos/análise , Monitoramento Ambiental/métodos , Gases/química , Eletroquímica , Monitoramento Ambiental/instrumentação , Filtração , Dióxido de Nitrogênio/análise , Dióxido de Nitrogênio/química , Ozônio/análise , Ozônio/química , Tamanho da Partícula , Termodinâmica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...