Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
CVIR Endovasc ; 7(1): 6, 2024 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-38180623

RESUMO

The aim of the article is to introduce a new term in post-procedural events related to the procedure itself. All the Societies and Councils report these events as complications and they are divided in mild, moderate and severe or immediate and delayed.On the other hand the term error is known as the application of a wrong plan, or strategy to achieve a goal.For the first time, we are trying to introduce the term "consequence"; assuming that the procedure is the only available and the best fit to clinical indication, a consequence should be seen as an expected and unavoidable occurrence of an "adverse event" despite correct technical execution.

2.
J Clin Med ; 13(2)2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-38256659

RESUMO

Transcatheter aortic valve implantation (TAVI) is a less invasive alternative to surgical implantation and its implementation is progressively increasing worldwide. We routinely perform pre-procedural aortic angiography CT to assess aortic dimensions and vascular anatomy. This study aims to evaluate the image quality of CTA for TAVI planning using dual-layer spectral CT, with virtual monoenergetic image reconstructions at 40 keV. Thirty-one patients underwent a CTA protocol with the injection of 20 mL of contrast media. Image quality was assessed by measuring the mean density in Hounsfield Units (HU), the signal-to-noise ratio, and the contrast-to-noise ratio in VMI reconstructions. Additionally, a blinded subjective analysis was conducted by two observers. The results showed significant enhancement at all sampled vascular levels with a gradual decrease in HU from proximal to distal regions. Favourable subjective ratings were given for all parameters, with greater variability in the evaluation of iliac axes. A significant negative correlation (p < 0.05) was observed between BMI and CA at all vascular levels, indicating reduced contrast enhancement with increasing BMI. Spectral CT, along with reducing iodine load, allows for obtaining high-quality images without a significant increase in noise. The reduction in iodine load can have positive implications in clinical practice, improving patient safety and resource efficiency.

3.
J Clin Med ; 12(23)2023 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-38068478

RESUMO

The aim of the study was to try to obtain more information on diagnostic samplings and biomarkers using dual-layer spectral CT in lung biopsies. Lung biopsies were performed by merging images obtained with CBCT with those from spectral CT to use them as functional guidance, experimenting with double sampling to determine the difference between the area with a higher Z-effective number and that with a lower Z-effective number. Ten patients with large lung lesions on spectral CT were selected and underwent percutaneous transthoracic lung mass biopsy. Technical success was calculated. The percentage of neoplastic, inflammatory, fibrotic, necrotic cells, or non-neoplastic lung parenchyma was reported. The possibility of carrying out immunohistochemical or molecular biology investigations was analyzed. All lesions were results malignant in 10/10 samples in the Zmax areas; in the Zmin areas, malignant cells were found in 7/10 samples. Technical success was achieved in 100% of cases for Zmax sampling and in 70% for Zmin sampling (p-value: 0.2105). The biomolecular profile was detected in 9/10 (90%) cases in Zmax areas, while in 4/10 (40%) cases in Zmin areas (p-value: 0.0573). The advantage of Z-effective imaging would be to identify a region of the lesion that is highly vascularized and probably richer in neoplastic cells, thus decreasing the risk of obtaining a non-diagnostic biopsy sample.

4.
Diagnostics (Basel) ; 13(19)2023 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-37835802

RESUMO

The efficacy and complication rates of percutaneous radiofrequency ablation (RFA) and cryoablation (CA) in the treatment of T1 renal masses in two Northern Italy hospitals were retrospectively investigated. Eighty-two patients with 80 T1a tumors and 10 T1b tumors treated with thermal ablation from 2015 through 2020 were included. A total of 43 tumors in 38 patients were treated with RFA (2.3 ± 0.9 cm), and 47 tumors in 44 patients were treated with CA (2.1 ± 0.8 cm). The mean follow-up observation period was 26 ± 19 months. The major complications and efficacy, as measured using the technical success and local tumor recurrence rates, were recorded. There were three (6.9%) technical failures with RFA and one (2.1%) with cryoablation (p = 0.30). Among the 40 tumors that were successfully treated with RFA, 1 tumor (2.5%) developed local tumor recurrence; 5/46 tumors that were treated with cryoablation (10.8%) developed local tumor recurrence (p = 0.17). T1b lesions (4.0 ± 0.7 cm) resulted in 1/6 technically unsuccessful cases with RFA and 0/4 with CA. No recurrent disease was detected in the T1b lesions. Major complications occurred after 2.3% (1/43) of RFAs and 0/47 of cryoablation procedures. RFA and cryoablation are both effective in the treatment of renal masses. Major complications with either procedure are uncommon.

5.
J Clin Med ; 12(20)2023 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-37892768

RESUMO

PURPOSE: The present study aims to evaluate the effectiveness and safety of the anti-reflux microcatheter during DEB-TACE with DC Bead LUMITM (radiopaque beads) for the treatment of hepatocellular carcinoma (HCC). METHODS: We performed an observational longitudinal prospective monocentric study to analyze all patients with HCC who underwent to DEB-TACE with DC Bead LUMITM and anti-reflux microcatheter. Technical success, the presence of residual disease, and clinical success were evaluated. The performance of the anti-reflux microcatheter on the basis of the percentage of tumor covered and the non-target embolization (NTE) was also evaluated. RESULTS: Twenty patients underwent DEB-TACE with DC Bead LUMITM and an anti-reflux microcatheter. Technical success was achieved in all cases. Residual disease in the target tumor was observed in 11/20 (55%) of cases and no residual disease was found in 9/20 (45%) of cases. The clinical response at 1-month follow-up was of PD 4/20 (20%), SD 7/20 (35%), and CR 9/20 (45%). No major complications were recorded, and 10% of cases had minor complications. The distribution of beads on post-procedural CBCT, classified according to the percentage of target nodule coverage, was ≥50% in 70% (14/20) of cases and between 30-50% in 30% of cases (6/20). NTE was never registered.

6.
Int J Mol Sci ; 24(16)2023 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-37628865

RESUMO

Despite the advances made in treatment, the prognosis of pancreatic ductal adenocarcinoma (PDAC) remains dismal, even in the locoregional and locally advanced stages, with high relapse rates after surgery. PDAC exhibits a chemoresistant and immunosuppressive phenotype, and the tumor microenvironment (TME) surrounding cancer cells actively participates in creating a stromal barrier to chemotherapy and an immunosuppressive environment. Recently, there has been an increasing use of interventional radiology techniques for the treatment of PDAC, although they do not represent a standard of care and are not included in clinical guidelines. Local approaches such as radiation therapy, hyperthermia, microwave or radiofrequency ablation, irreversible electroporation and high-intensity focused ultrasound exert their action on the tumor tissue, altering the composition and structure of TME and potentially enhancing the action of chemotherapy. Moreover, their action can increase antigen release and presentation with T-cell activation and reduction tumor-induced immune suppression. This review summarizes the current evidence on locoregional therapies in PDAC and their effect on remodeling TME to make it more susceptible to the action of antitumor agents.


Assuntos
Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Humanos , Microambiente Tumoral , Recidiva Local de Neoplasia , Neoplasias Pancreáticas/terapia , Carcinoma Ductal Pancreático/terapia , Neoplasias Pancreáticas
7.
Technol Cancer Res Treat ; 22: 15330338231185277, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37608585

RESUMO

OBJECTIVE: The aim of this study is to evaluate the feasibility, safety, and short-term effectiveness of a high-power (150 W) microwave ablation (MWA) device for tumor ablation in the lung, liver, and kidney. METHODS: Between December 2021 and June 2022, patients underwent high-power MWA for liver, lung, and kidney tumors. A retrospective observational study was conducted in accordance with the Declaration of Helsinki. The MWA system utilized a 150-W, 2.45-GHz microwave generator (Emprint™ HP Ablation System, Medtronic). The study assessed technical success, safety, and effectiveness, considering pre- and post-treatment diameter and volume, lesion location, biopsy and/or cone beam computed tomography (CBCT) usage, MWA ablation time, MWA power, and dose-area product (DAP). RESULTS: From December 2021 to June 2022, 16 patients were enrolled for high-power MWA. Treated lesions included hepatocellular carcinoma (10), liver metastasis from colon cancer (1), liver metastasis from pancreatic cancer (1), squamous cell lung carcinoma (2), renal cell carcinoma (1), and renal oncocytoma (1). Technical success rate was 100%. One grade 1 complication (6.25%) was reported according to CIRSE classification. Overall effectiveness was 92.8%. Pre- and post-treatment mean diameters for liver lesions were 19.9 mm and 37.5 mm, respectively; for kidney lesions, 34 mm and 35 mm; for lung lesions, 29.5 mm and 31.5 mm. Pre- and post-treatment mean volumes for liver lesions were 3.4 ml and 24 ml, respectively; for kidney lesions, 8.2 ml and 20.5 ml; for lung lesions, 10.2 ml and 32.7 ml. The mean ablation time was 48 minutes for liver, 42.5 minutes for lung, and 42.5 minutes for renal ablation. The mean DAP for all procedures was 40.83 Gcm2. CONCLUSION: This preliminary study demonstrates the feasibility, safety, and effectiveness of the new 150 W MWA device. Additionally, it shows reduced ablation times for large lesions.


Assuntos
Carcinoma Hepatocelular , Ablação por Cateter , Neoplasias Hepáticas , Humanos , Micro-Ondas/uso terapêutico , Ablação por Cateter/métodos , Carcinoma Hepatocelular/cirurgia , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/cirurgia , Rim/cirurgia , Pulmão/diagnóstico por imagem , Pulmão/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
8.
9.
Diagnostics (Basel) ; 13(14)2023 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-37510092

RESUMO

Percutaneous image-guided thermal ablation is included in most society guidelines for treatment of hepatocellular carcinoma (HCC). The results of this treatment in terms of efficacy depend on the ability to precisely place the device into the target tumor. Ultrasound (US) is a commonly used imaging guidance modality for its real-time feedback. However, an accurate device deployment remains challenging in some clinical scenarios, including cases of tumors that are undetectable or not clearly visible by US. To overcome this problem, fusion imaging techniques have been developed, which combine images from different modalities. The most widely known technique combines pre-procedural contrast-enhanced computed tomography (CT) or magnetic resonance imaging (MRI) with real-time US scans. Cone beam CT (CBCT) is a technology that can provide intra-procedural cross-sectional images, which can be registered to images from other modalities, including preprocedural CT/MR scans. The aim of our study is to report the preliminary experience on percutaneous microwave ablation (MWA) of patients with HCC that were treated using the "double fusion" technique, which combines the use of US fusion imaging and CBCT fusion imaging. We describe the technical details, feasibility, safety and short-term efficacy of this technique in a small series of eight patients with 11 HCCs.

10.
J Clin Med ; 12(14)2023 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-37510833

RESUMO

Dual-layer Dual-Energy CT (dl-DECT) allows one to create virtual non-contrast (VNC) reconstructions from contrast-enhanced CT scans, with a consequent decrease of the radiation dose. This study aims to assess the reliability of VNC for the diagnostic evaluation of renal masses in comparison with true non-contrast (TNC) images. The study cohort included 100 renal masses in 40 patients who underwent dl-DECT between June and December 2021. Attenuation values and standard deviations were assessed through the drawing of regions of interest on TNC and VNC images reconstructed from corticomedullary and nephrographic phases. A Wilcoxon signed-rank test was performed in order to assess equivalence of data and Spearman's Rho correlation coefficient to evaluate correlations between each parameter. The diagnostic accuracy of VNC was estimated through the performance of receiver operating characteristic (ROC) curve analysis. Differences between attenuation values were, respectively, 74%, 18%, 5% and 3% (TNC-VNCcort), and 74%, 15%, 9% and 2% (TNC-VNCneph). The Wilcoxon signed-rank test demonstrated the equivalence of attenuation values between the TNC and VNC images. The diagnostic performance of VNC images in the depiction of kidney simple cysts remains high compared to TNC (VNCcort-AUC: 0.896; VNCneph-AUC: 0.901, TNC-AUC: 0.903). In conclusion, quantitative analysis of attenuation values showed a strong agreement between VNC and TNC images in the evaluation of renal masses.

11.
Radiol Med ; 128(8): 891-899, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37310558

RESUMO

PURPOSE: To compare conventional CT images and virtual monoenergetic images (VMI) at dual-layer dual-energy CT (dlDECT) in patients with colorectal cancer (CRC) through quantitative analysis and to investigate the added value of VMI. MATERIAL AND METHODS: Sixty-six consecutive patients with histologically documented CRC and available VMI reconstructions were retrospectively investigated. Subsequently, forty-two patients, without any colonic disease at colonoscopy, were selected as control group. Conventional CT images and VMI reconstructions at energy levels ranging from 40 (VMI40) to 100 keV (VMI100) in 10 keV increments, were obtained from the late arterial phase. First, signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were obtained to select the best VMI reconstruction. Finally, the diagnostic accuracy of conventional CT and VMI40 in late arterial phase was evaluated. RESULTS: On quantitative analysis, SNR and CNR were higher for VMI40 (19.5 ± 7.7 and 11.8 ± 6.2, respectively) with statistically significant differences compared to conventional CT (P < 0.05) and all the other VMI reconstructions (P < 0.05), except for VMI50 (P > 0.05). The addition of VMI40 to conventional CT images significantly improved the area under the curve (AUC) for the diagnosis of CRC, increasing it from 0.875 to 0.943 for reader 1 (P < 0.05) and from 0.916 to 0.954 for reader 2 (P < 0.05). The improvement was greater in the less experienced radiologist (0.068) compared to the more experienced one (0.037). CONCLUSION: VMI40 has showed the highest quantitative image parameters. Furthermore, the use of VMI40 can lead to a significant improvement in the diagnostic performance for detecting CRC.


Assuntos
Neoplasias Colorretais , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Tomografia Computadorizada por Raios X/métodos , Estudos Retrospectivos , Razão Sinal-Ruído , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Neoplasias Colorretais/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
12.
Semin Vasc Surg ; 36(2): 307-318, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37330243

RESUMO

"Acute venous problems" refers to a group of disorders that affect the veins and result in sudden and severe symptoms. They can be classified based on the pathological triggering mechanisms, such as thrombosis and/or mechanical compression, and their consequences, including symptoms, signs, and complications. The management and therapeutic approach depend on the severity of the disease, the location, and the involvement of the vein segment. Although summarizing these conditions can be challenging, the objective of this narrative review was to provide an overview of the most common acute venous problems. This will include an exhaustive yet concise and practical description of each condition. The multidisciplinary approach remains one of the major advantages in dealing with these conditions, maximizing the results and the prevention of complications.


Assuntos
Filtros de Veia Cava , Trombose Venosa , Humanos , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/terapia , Veias/diagnóstico por imagem , Veias/cirurgia , Filtros de Veia Cava/efeitos adversos , Veia Cava Inferior
13.
Jpn J Radiol ; 41(11): 1208-1215, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37341870

RESUMO

The large bowel can be affected by inflammatory bowel diseases, namely ulcerative colitis and Crohn's disease, with the latter occurring either as a unique localization or in conjunction with simultaneous ileal involvement. The differential diagnosis among these conditions is challenging and relies on clinical symptoms, laboratory tests and endoscopy with biopsy. However, as these features can overlap, a conclusive diagnosis is not always achievable, and the underlying cause remains indeterminate. Currently, endoscopy is the reference standard for colonic assessment, although its invasiveness limits its use and repetition within a short timeframe. Magnetic Resonance Enterography is a non-invasive, radiation-free technique that has been extensively and effectively employed in the intestinal evaluation of patients with Crohn's disease in recent years. Although the main goal of this technique is generally focused on evaluating small bowel loops, it can also provide important information about the large bowel if an adequate fulfillment by the oral contrast medium is achieved. The purpose of this work is, therefore, to put emphasis on the potential role of Magnetic Resonance Enterography in assessing the large bowel. In fact, this imaging modality is capable of providing valuable information for comprehensive staging and follow-up of inflammatory bowel diseases within the large bowel, thus complementing the clinical picture and the endoscopic features in the context of a differential diagnosis.


Assuntos
Doença de Crohn , Doenças Inflamatórias Intestinais , Humanos , Doença de Crohn/diagnóstico por imagem , Doenças Inflamatórias Intestinais/diagnóstico por imagem , Intestino Delgado , Colo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética
14.
Diagnostics (Basel) ; 13(10)2023 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-37238225

RESUMO

A 56-year-old man with a previous right nephrectomy for multiple papillary renal cell carcinomas (pRCC) underwent a follow-up CT scan. Using a dual-layer dual-energy CT (dlDECT), we demonstrated the presence of a small amount of fat in a 2.5 cm pRCC that mimicked the diagnosis of angiomyolipoma (AML). Histological examination demonstrated the absence of macroscopic intratumoral adipose tissue, showing a fair amount of enlarged foam macrophages loaded with intracytoplasmic lipids. The presence of fat density in an RCC is an extremely rare occurrence in the literature. To our knowledge, this is the first description using dlDECT of a minimal amount of fat tissue in a small RCC due to the presence of tumor-associated foam macrophages. Radiologists should be aware of this possibility when characterizing a renal mass with DECT. The option of RCCs must be considered, especially in the case of masses with an aggressive character or a positive history of RCC.

15.
Tomography ; 9(3): 909-930, 2023 04 30.
Artigo em Inglês | MEDLINE | ID: mdl-37218935

RESUMO

Computed Tomography Urography (CTU) is a multiphase CT examination optimized for imaging kidneys, ureters, and bladder, complemented by post-contrast excretory phase imaging. Different protocols are available for contrast administration and image acquisition and timing, with different strengths and limits, mainly related to kidney enhancement, ureters distension and opacification, and radiation exposure. The availability of new reconstruction algorithms, such as iterative and deep-learning-based reconstruction has dramatically improved the image quality and reducing radiation exposure at the same time. Dual-Energy Computed Tomography also has an important role in this type of examination, with the possibility of renal stone characterization, the availability of synthetic unenhanced phases to reduce radiation dose, and the availability of iodine maps for a better interpretation of renal masses. We also describe the new artificial intelligence applications for CTU, focusing on radiomics to predict tumor grading and patients' outcome for a personalized therapeutic approach. In this narrative review, we provide a comprehensive overview of CTU from the traditional to the newest acquisition techniques and reconstruction algorithms, and the possibility of advanced imaging interpretation to provide an up-to-date guide for radiologists who want to better comprehend this technique.


Assuntos
Rim , Tomografia Computadorizada por Raios X , Ureter , Bexiga Urinária , Urografia , Humanos , Inteligência Artificial , Tomografia Computadorizada por Raios X/tendências , Urografia/tendências , Rim/diagnóstico por imagem , Neoplasias Renais/diagnóstico por imagem , Algoritmos , Processamento de Imagem Assistida por Computador , Ureter/diagnóstico por imagem , Bexiga Urinária/diagnóstico por imagem
16.
Technol Cancer Res Treat ; 22: 15330338231157193, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36916200

RESUMO

Breast cancer (BC) is the most frequently diagnosed malignancy among women. In the past two decades, new technologies and BC screening have led to the diagnosis of smaller and earlier-stage BC (ESBC). Therefore, percutaneous minimally invasive techniques (PMIT) were adopted to treat patients unfit for surgery, women who refuse it, or elderly patients with comorbidities that could make surgery a difficult and life-threatening treatment. The target of PMIT is small-size ESBC with the scope of obtaining similar efficacy as surgery. Minimally invasive treatments are convenient alternatives with promising effectiveness, lower morbidity, less cost, less scarring and pain, and more satisfying cosmetic results. Ablative techniques used in BC are cryoablation, radiofrequency ablation, microwave ablation, high-intensity focused ultrasound (US), and laser ablation. The aim of our study is to discuss the current status of percutaneous management of BC, evaluate the clinical outcomes of PMIT in BC, and analyze future perspectives regarding ablation therapy in BC.


Assuntos
Técnicas de Ablação , Neoplasias da Mama , Ablação por Cateter , Criocirurgia , Ablação por Ultrassom Focalizado de Alta Intensidade , Terapia a Laser , Humanos , Feminino , Idoso , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/cirurgia , Criocirurgia/métodos , Técnicas de Ablação/métodos , Terapia a Laser/métodos , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Ablação por Cateter/métodos
18.
Diagnostics (Basel) ; 13(2)2023 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-36673027

RESUMO

Due to its widespread availability, low cost, feasibility at the patient's bedside and accessibility even in low-resource settings, chest X-ray is one of the most requested examinations in radiology departments. Whilst it provides essential information on thoracic pathology, it can be difficult to interpret and is prone to diagnostic errors, particularly in the emergency setting. The increasing availability of large chest X-ray datasets has allowed the development of reliable Artificial Intelligence (AI) tools to help radiologists in everyday clinical practice. AI integration into the diagnostic workflow would benefit patients, radiologists, and healthcare systems in terms of improved and standardized reporting accuracy, quicker diagnosis, more efficient management, and appropriateness of the therapy. This review article aims to provide an overview of the applications of AI for chest X-rays in the emergency setting, emphasizing the detection and evaluation of pneumothorax, pneumonia, heart failure, and pleural effusion.

19.
Radiol Case Rep ; 18(3): 809-813, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36589500

RESUMO

Breast metastasis from extra-mammary neoplasm is a rare condition, accounting for approximately 1.2%-2% of all breast malignancies. Melanoma, lung cancer, gynecological, and hematological cancers can metastasis to the breast. Male breast metastasis is extremely rare and, no evidence of metastasis from cutaneous squamous cell carcinoma in a male breast have been reported to our knowledge. We describe a case of an 81-year-old man who came to our attention for a palpable solid mass in the upper-outer aspect of the left breast with the final histological diagnosis of breast metastasis from non-keratoblastic cutaneous squamous cell carcinoma.

20.
Radiol Med ; 128(1): 16-26, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36583843

RESUMO

BACKGROUND: The aim of the study was to provide radiologists and clinicians a rapid tool for assessment of intestinal inflammation in Crohn's disease (CD) patients through quantification of diffusion-weighted imaging (DWI) signal intensity while performing magnetic resonance enterography (MRE). MATERIALS AND METHODS: A monocentric retrospective study was conducted between September 2018 and July 2021 on CD patients who underwent MRE. Two radiologists measured signal intensity on DWI scans at the highest b-value (800 s/mm2) within pathologic intestinal walls, lymph nodes, spleen and psoas muscle and calculated the relative ratios. Spearman, Mann-Whitney and Jonckheere-Terpstra tests were applied for estimating correlation among ratios, significant differences between the two patient groups and determining the trend in relation to endoscopic classes. Wilcoxon's and Cronbach's alpha tests were employed for comparison of DWI measurements and ratios between the two observers. RESULTS: Fifty-nine patients were enrolled in the study. In the non-surgical group, correlation has been found among Simple Endoscopic Score for Crohn's Disease (SES-CD) classes and the different ratios: bowel/spleen (p = 0.034), bowel/psoas (p = 0.008) and bowel/lymph node (p = 0.010). Within the surgical group, positive correlation was found only between bowel/lymph node ratio and bowel/psoas ratio (p = 0.014). The J-T test demonstrated an increasing monotonic trend for bowel/psoas ratio and bowel/lymph node ratio and SES-CD classes. Inter-reader evaluation demonstrated no statistical differences for DWI measurements and high degree of concordance for the final ratios. CONCLUSION: DWI ratios correlate with endoscopic classes in non-surgical patients and have inter-observer reproducibility.


Assuntos
Doença de Crohn , Humanos , Doença de Crohn/diagnóstico por imagem , Doença de Crohn/patologia , Estudos Retrospectivos , Reprodutibilidade dos Testes , Imagem de Difusão por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...