Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 195
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38693866

RESUMO

AIMS: Evaluation of left and right ventricular longitudinal systolic function may enhance risk stratification following aortic valve replacement (AVR). The study objective was to evaluate the changes in left and right ventricular longitudinal systolic function and RV-pulmonary artery (RV-PA) coupling from baseline to 30-days and 1-year after aortic valve replacement (AVR). METHODS AND RESULTS: LV longitudinal strain (LS), tricuspid annulus plane systolic excursion (TAPSE), and RV-PA coupling were evaluated in patients from the PARTNER-2A surgical AVR (SAVR) arm (n=985) and from the PARTNER-2 SAPIEN-3 registry (n=719). TAPSE and RV-PA coupling decreased significantly following SAVR, but remained stable following TAVR. Lower LV LS, TAPSE, or RV-PA coupling at baseline were associated with increased risk of the composite of death, hospitalization, and stroke at 5-years (Adjusted-HRs for LV LS<15%: 1.24 95%CI 1.05-1.45, p=0.001; TAPSE<14mm: 1.44 95%CI 1.21-1.73, p<0.001; RV/PA coupling<0.55mm/mmHg: 1.32 95% CI 1.07-1.63, p=0.011). Reduced TAPSE at baseline was the most powerful predictor of the composite endpoint at 5-years. Patients with LV ejection fraction <50% at baseline had increased risk of the primary endpoint with SAVR (HR: 1.34, 95%CI 1.08-1.68, p=0.009) but not with TAVR (HR: 1.12, 95%CI 0.88-1.42). Lower RV-PA coupling at 30-days showed the strongest association with cardiac mortality. CONCLUSION: SAVR but not TAVR was associated with a marked deterioration in RV longitudinal systolic function and RV-PA coupling. Lower TAPSE and RV-PA coupling at 30-days were associated with inferior clinical outcomes at 5-years. In patients with LVEF<50%, TAVR was associated with superior 5-year outcomes.

2.
JTCVS Open ; 17: 47-54, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38420548

RESUMO

Background: Although various hemodynamic parameters to assess prosthetic performance are available, prosthesis-patient mismatch (PPM) is defined exclusively by effective orifice area (EOA) index thresholds. Adjusting for the Society of Thoracic Surgeons predicted risk of mortality (STS PROM), we aimed to explore the added value of postoperative hemodynamic parameters for the prediction of all-cause mortality at 5 years after aortic valve replacement. Methods: Data were obtained from the Pericardial Surgical Aortic Valve Replacement (PERIGON) Pivotal Trial, a multicenter prospective cohort study examining the performance of the Avalus bioprosthesis. Candidate predictors were assessed at the first follow-up visit; patients who had no echocardiography data, withdrew consent, or died before this visit were excluded. Candidate predictors included peak jet velocity, mean pressure gradient, EOA, predicted and measured EOA index, Doppler velocity index, indexed internal prosthesis orifice area, and categories for PPM. The performance of Cox models was investigated using the c-statistic and net reclassification improvement (NRI), among other tools. Results: A total of 1118 patients received the study valve, of whom 1022 were eligible for the present analysis. In univariable analysis, STS PROM was the sole significant predictor of all-cause mortality (hazard ratio, 1.40; 95% confidence interval, 1.26-1.55). When extending the STS PROM with single hemodynamic parameters, neither the c-statistics nor the NRIs demonstrated added prognostic value compared to a model with STS PROM alone. Similar findings were observed when multiple hemodynamic parameters were added. Conclusions: The STS PROM was found to be the main predictor of patient prognosis. The additional prognostic value of postoperative hemodynamic parameters for the prediction of all-cause mortality was limited.

3.
Arch Cardiol Mex ; 94(2): 219-239, 2024 02 07.
Artigo em Espanhol | MEDLINE | ID: mdl-38325117

RESUMO

This consensus of nomenclature and classification for congenital bicuspid aortic valve and its aortopathy is evidence-based and intended for universal use by physicians (both pediatricians and adults), echocardiographers, advanced cardiovascular imaging specialists, interventional cardiologists, cardiovascular surgeons, pathologists, geneticists, and researchers spanning these areas of clinical and basic research. In addition, as long as new key and reference research is available, this international consensus may be subject to change based on evidence-based data1.


Este consenso de nomenclatura y clasificación para la válvula aórtica bicúspide congénita y su aortopatía está basado en la evidencia y destinado a ser utilizado universalmente por médicos (tanto pediatras como de adultos), médicos ecocardiografistas, especialistas en imágenes avanzadas cardiovasculares, cardiólogos intervencionistas, cirujanos cardiovasculares, patólogos, genetistas e investigadores que abarcan estas áreas de investigación clínica y básica. Siempre y cuando se disponga de nueva investigación clave y de referencia, este consenso internacional puede estar sujeto a cambios de acuerdo con datos basados en la evidencia1.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38243591

RESUMO

BACKGROUND: Although impaired left ventricular (LV) global longitudinal strain (GLS) with apical sparing is a feature of cardiac amyloidosis (CA), its diagnostic accuracy has varied across studies. We aimed to determine the ability of apical sparing ratio (ASR) and most common echocardiographic parameters to differentiate patients with confirmed CA from those with clinical and/or echocardiographic suspicion of CA, but with this diagnosis ruled out. METHODS: We identified 544 patients with confirmed CA and 200 controls as defined above (CTRL Patients). Measurements from transthoracic echocardiograms (TTE) were performed using artificial intelligence software (Us2.AI, Singapore) and audited by an experienced echocardiographer. Receiver-operating characteristic curve analysis was used to evaluate the diagnostic performance and optimal cutoffs for the differentiation of CA patients from CTRL Patients. Additionally, a group of 174 healthy subjects (Healthy CTRL) was included to provide insight on how Patients and Healthy controls differed echocardiographically. RESULTS: LV GLS was more impaired (-13.9 ± 4.6% vs -15.9 ± 2.7%, p < 0.0005) and ASR was higher (2.4 ± 1.2 vs 1.7 ± 0.9, p < 0.0005) in the CA group vs. CTRL Patients. Relative wall thickness and ASR were the most accurate parameters for differentiating CA from CTRL Patients (AUC: 0.77 and 0.74, respectively). However, even with the optimal cutoff of 1.67, ASR was only 72% sensitive and 66% specific for CA, indicating presence of apical sparing in 32% of CTRL Patients and even in 6% Healthy CTRLs. CONCLUSIONS: Apical sparing did not prove to be a CA-specific biomarker for accurate identification of CA, when compared to clinically similar controls with no CA.

6.
Eur Heart J Cardiovasc Imaging ; 25(2): 152-160, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-37602694

RESUMO

AIMS: Right ventricular (RV) functional assessment is mainly limited to its longitudinal contraction. Dedicated three-dimensional echocardiography (3DE) software enabled the separate assessment of the non-longitudinal components of RV ejection fraction (EF). The aims of this study were (i) to establish normal values for RV 3D-derived longitudinal, radial, and anteroposterior EF (LEF, REF, and AEF, respectively) and their relative contributions to global RVEF, (ii) to calculate 3D RV strain normal values, and (iii) to determine sex-, age-, and race-related differences in these parameters in a large group of normal subjects (WASE study). METHODS AND RESULTS: 3DE RV wide-angle datasets from 1043 prospectively enrolled healthy adult subjects were analysed to generate a 3D mesh model of the RV cavity (TomTec). Dedicated software (ReVISION) was used to analyse RV motion along the three main anatomical planes. The EF values corresponding to each plane were identified as LEF, REF, and AEF. Relative contributions were determined by dividing each EF component by the global RVEF. RV strain analysis included longitudinal, circumferential, and global area strains (GLS, GCS, and GAS, respectively). Results were categorized by sex, age (18-40, 41-65, and >65 years), and race. Absolute REF, AEF, LEF, and global RVEF were higher in women than in men (P < 0.001). With aging, both sexes exhibited a decline in all components of longitudinal shortening (P < 0.001), which was partially compensated in elderly women by an increase in radial contraction. Black subjects showed lower RVEF and GAS values compared with white and Asian subjects of the same sex (P < 0.001), and black men showed significantly higher RV radial but lower longitudinal contributions to global RVEF compared with Asian and white men. CONCLUSION: 3DE evaluation of the non-longitudinal components of RV contraction provides additional information regarding RV physiology, including sex-, age-, and race-related differences in RV contraction patterns that may prove useful in disease states involving the right ventricle.


Assuntos
Ecocardiografia Tridimensional , Disfunção Ventricular Direita , Adulto , Masculino , Humanos , Feminino , Idoso , Ventrículos do Coração/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Volume Sistólico/fisiologia , Envelhecimento , Função Ventricular Direita/fisiologia
8.
EuroIntervention ; 20(1): 85-94, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37982152

RESUMO

BACKGROUND: Transcatheter aortic valve implantation is an effective treatment for patients with aortic stenosis; however, complications related to paravalvular leakage (PVL) persist, including increased risk of mortality, cardiovascular mortality, and rehospitalisation. AIMS: We sought to evaluate the clinical outcomes and valve performance at 1 year in patients with severe aortic stenosis treated with the ACURATE neo2 valve in a post-market clinical setting. METHODS: Valve Academic Research Consortium-2 safety events were assessed up to 1 year. Independent core laboratories evaluated echocardiographic measures of valve performance and hypoattenuated leaflet thickening (HALT; as measured by four-dimensional computed tomography). RESULTS: The study enrolled 250 patients (64% female; mean age: 81 years; baseline Society of Thoracic Surgeons risk score: 2.9±2.0%); 246 patients were implanted with ACURATE neo2. All-cause mortality was 0.8% at 30 days and 5.1% at 1 year. The 1-year rates for stroke and disabling stroke were 3.0% and 1.3%, respectively. Overall, HALT of >50% leaflet involvement of at least one leaflet was present in 9% of patients at 30 days and in 12% of patients at 1 year. No association was observed between the presence of HALT and 1-year clinical or haemodynamic outcomes. Early haemodynamic improvements were maintained up to 1 year (mean aortic valve gradient: 47.6±14.5 mmHg at baseline, 7.6±3.2 mmHg at 1 year; mean aortic valve area: 0.7±0.2 cm2 at baseline, 1.7±0.4 cm2 at 1 year). At 1 year, 99% of patients had mild or no/trace PVL (<1% had moderate PVL; no patient had severe PVL). CONCLUSIONS: The study outcomes confirm favourable performance and safety up to 1 year in patients treated with ACURATE neo2 in routine clinical practice. (ClinicalTrials.gov: NCT04655248).


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Desenho de Prótese , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
9.
Int J Cardiol ; 395: 131431, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-37832606

RESUMO

BACKGROUND: Recent randomized studies have broadened the indication of transcatheter aortic valve replacement (TAVR) to also include low-surgical-risk patients. However, the data on self-expanding (SE) and balloon-expandable (BE) valves in low-risk patients remain sparse. METHODS: The current study is a post hoc analysis of combined data from both LRT 1.0 and 2.0 trials comparing BE and SE transcatheter heart valves. RESULTS: A total of 294 patients received a BE valve, and 102 patients received an SE valve. The 30-day clinical outcomes were similar across both groups except for stroke (4.9% vs. 0.7%, p = 0.014) and permanent pacemaker implantation (17.8% vs. 5.8%, p < 0.001), which were higher in the SE cohort than the BE cohort. No difference was observed in terms of paravalvular leak (≥moderate) between the groups (0% vs. 1.5%, p = 0.577). SE patients had higher aortic valve area (1.92 ± 0.43 mm2 vs. 1.69 ± 0.45 mm2, p < 0.001) and lower mean gradient (8.93 ± 3.53 mmHg vs. 13.41 ± 4.73 mmHg, p < 0.001) than BE patients. In addition, the rate of subclinical leaflet thrombosis was significantly lower in SE patients (5.6% vs. 13.8%, p = 0.038). CONCLUSION: In this non-randomized study assessing SE and BE valves in low-risk TAVR patients, SE valves are associated with better hemodynamics and lesser leaflet thrombosis, with increased rates of stroke and permanent pacemaker implantation at 30 days; however, this could be due to certain patient-dependent factors not fully evaluated in this study. The long-term implications of these outcomes on structural valve durability remain to be further investigated. CLINICAL TRIAL REGISTRY: LRT 1.0: NCT02628899 LRT 2.0: NCT03557242.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Acidente Vascular Cerebral/etiologia , Trombose/etiologia , Resultado do Tratamento , Desenho de Prótese , Fatores de Risco
10.
Artigo em Inglês | MEDLINE | ID: mdl-38060997

RESUMO

AIMS: The conceptual framework of proportionate versus disproportionate mitral regurgitation (MR) translates poorly to individual patients with heart failure (HF) and secondary MR. A novel index, the ratio of MR severity to left atrial volume (LAV), may identify patients with "disproportionate" MR and a higher risk of events. The objectives, therefore, were to investigate the prognostic impact of MR severity to LAV ratio on outcomes among HF patients with severe secondary MR randomized to transcatheter edge-to-edge repair (TEER) with the MitraClipTM device plus guideline-directed medical therapy (GDMT) vs. GDMT alone in the COAPT trial. METHODS AND RESULTS: The ratio of preprocedural regurgitant volume (RVol) to LAV was calculated from baseline transthoracic echocardiograms. The primary endpoint was 2-year covariate-adjusted rate of HF hospitalization (HFH).Among 567 patients, the median RVol/LAV was 0.67 (IQR 0.48-0.91). In patients randomized to GDMT alone, lower RVol/LAV was independently associated with an increased 2-year risk of HFH (adjHR: 1.77; 95% CI: 1.20-2.63). RVol/LAV was a stronger predictor of adverse outcomes than RVol or LAV alone. Treatment with TEER plus GDMT compared with GDMT alone was associated with lower 2-year rates of HFH both in patients with low and high RVol/LAV (Pinteraction = 0.28). Baseline RVol/LAV ratio was unrelated to 2-year mortality, health status, or functional capacity in either treatment group. CONCLUSIONS: Low RVol/LAV ratio was an independent predictor of 2-year HFH in HF patients with severe MR treated with GDMT alone in the COAPT trial. TEER improved outcomes regardless of baseline RVol/LAV ratio. CLINICAL TRIAL REGISTRATION: Trial Name: Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation (The COAPT Trial) (COAPT) ClinicalTrial.gov Identifier: NCT01626079 URL: https://clinicaltrials.gov/ct2/show/NCT01626079.

11.
Circ Rep ; 5(11): 424-429, 2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-37969234

RESUMO

Background: Although accurate assessment of right ventricular (RV) morphology and function is clinically important, data regarding reference values for echocardiographic measurements of the right ventricle in the Japanese population are limited. Methods and Results: The World Alliance Society of Echocardiography (WASE) Normal Values Study was conducted to examine normal echocardiographic values in 15 countries. Using the WASE study database, we analyzed 2-dimensional echocardiographic parameters of RV size and systolic function in 192 healthy Japanese individuals and compared them with those obtained from 153 healthy American individuals. In the Japanese population, the absolute values of RV dimensions were smaller for women than men, although the difference disappeared after the data were adjusted for body surface area. RV dimensions, RV length and RV area were smaller in the elderly, but age did not affect RV systolic function. The absolute value, but not the adjusted value, of RV size tended to be smaller in Japanese than American individuals for both sexes. For men, RV systolic function parameters were lower in the Japanese population. This trend was not seen in women. Conclusions: The present study identified normal reference values for RV size and systolic function in a healthy Japanese population. Sex, age, and race had a significant impact on RV size; however, this trend was weak for RV systolic function.

12.
Int J Cardiovasc Imaging ; 39(12): 2507-2516, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37872467

RESUMO

Machine learning techniques designed to recognize views and perform measurements are increasingly used to address the need for automation of the interpretation of echocardiographic images. The current study was designed to determine whether a recently developed and validated deep learning (DL) algorithm for automated measurements of echocardiographic parameters of left heart chamber size and function can improve the reproducibility and shorten the analysis time, compared to the conventional methodology. The DL algorithm trained to identify standard views and provide automated measurements of 20 standard parameters, was applied to images obtained in 12 randomly selected echocardiographic studies. The resultant measurements were reviewed and revised as necessary by 10 independent expert readers. The same readers also performed conventional manual measurements, which were averaged and used as the reference standard for the DL-assisted approach with and without the manual revisions. Inter-reader variability was quantified using coefficients of variation, which together with analysis times, were compared between the conventional reads and the DL-assisted approach. The fully automated DL measurements showed good agreement with the reference technique: Bland-Altman biases 0-14% of the measured values. Manual revisions resulted in only minor improvement in accuracy: biases 0-11%. This DL-assisted approach resulted in a 43% decrease in analysis time and less inter-reader variability than the conventional methodology: 2-3 times smaller coefficients of variation. In conclusion, DL-assisted approach to analysis of echocardiographic images can provide accurate left heart measurements with the added benefits of improved reproducibility and time savings, compared to conventional methodology.


Assuntos
Aprendizado Profundo , Ecocardiografia Tridimensional , Humanos , Ventrículos do Coração/diagnóstico por imagem , Variações Dependentes do Observador , Fluxo de Trabalho , Reprodutibilidade dos Testes , Ecocardiografia Tridimensional/métodos , Valor Preditivo dos Testes , Ecocardiografia
13.
Heliyon ; 9(10): e20334, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37810843

RESUMO

Background: Left atrial volume (LAV) has prognostic value. Guidelines propose indexation to body surface area (BSA), however studies demonstrate this can overcorrect for body size. Limited studies investigate indexation across different ethnicities. We sought to evaluate the effect of ethnicity on indexation. Methods: Using data from the World Alliance of Societies of Echocardiography (WASE) cohort, healthy subjects were classified by race as White, Black, Asian, or Other. Biplane LAV was indexed to traditional isometric measurements (BSA, height, weight, ideal body weight (IBW) and IBW derived BSA (IBSA)), as well as previously-derived allometric height exponents (2.7 and 1.72). Additionally, an allometric height exponent for our cohort was derived (linear regression of the logarithmic transformation of LAV = a(height)b) as 1.87. All indices were then assessed using Spearman correlation, with a good index retaining correlation of LAV/index to raw LAV (r∼1), while avoiding overcorrection by the index (r∼0). Results: There were 1366 subjects (White: 524, Black: 149, Asian: 523, Other: 170; median age 44 years, 653 females (47.8%)). In the entire group, BSA, IBSA, height1.87 and height1.72 performed well with retaining correlation to raw LAV (r > 0.9 for all), and minimising overcorrection to body size (r < 0.1 for all). On race-specific analysis, BSA overcorrected for body size in the White population (r = 0.128). Height1.72 minimised overcorrection for body size in all populations (r ≤ 0.1 for all races). Conclusion: Despite a cohort with normal BMI, there was still disparity in LAV indexation with BSA across races. Allometric height indexation, particularly using height1.72, is a possible solution, although further validation studies in BMI extremes are required.

14.
JACC Cardiovasc Interv ; 16(21): 2600-2610, 2023 11 13.
Artigo em Inglês | MEDLINE | ID: mdl-37877913

RESUMO

BACKGROUND: The fourth-generation mitral transcatheter edge-to-edge repair (M-TEER) device introduced an improved clip deployment sequence, independent leaflet grasping, and 2 wider clip sizes to tailor the treatment of patients with mitral regurgitation (MR) for a broad range of anatomies. The 30-day safety and effectiveness of the fourth-generation M-TEER device were previously demonstrated. OBJECTIVES: The aim of this study was to evaluate 1-year outcomes in a contemporary, real-world cohort of subjects treated with the MitraClip G4 system. METHODS: EXPAND G4 is an ongoing prospective, multicenter, international, single-arm study that enrolled subjects with primary and secondary MR. One-year outcomes included MR severity (echocardiographic core laboratory assessed), heart failure hospitalization, all-cause mortality, functional capacity (NYHA functional class), and quality of life (Kansas City Cardiomyopathy Questionnaire). RESULTS: A total of 1,164 subjects underwent M-TEER from 2020 to 2022. At 1 year, there was a durable reduction in MR to mild or less in 92.6% and to none or trace in 44.2% (P < 0.0001 vs baseline). Few subjects had major adverse events through 1 year (<2% for myocardial infarction, surgical reintervention, or single-leaflet device attachment). The 1-year Kaplan-Meier estimates for all-cause mortality and heart failure hospitalization were 12.3% and 16.9%. Significant improvements in functional capacity (NYHA functional class I or II in 82%; P < 0.0001 vs baseline) and quality of life (18.5-point Kansas City Cardiomyopathy Questionnaire overall summary score improvement; P < 0.0001) were observed. CONCLUSIONS: M-TEER with the fourth-generation M-TEER device was safe and effective at 1 year, with durable reductions in MR severity to ≤1+ in more than 90% of patients and concomitant improvements in functional status and quality of life.


Assuntos
Cardiomiopatias , Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Qualidade de Vida , Estudos Prospectivos , Resultado do Tratamento , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia
15.
J Am Heart Assoc ; 12(19): e029518, 2023 10 03.
Artigo em Inglês | MEDLINE | ID: mdl-37776192

RESUMO

Background Arterial tortuosity is associated with adverse events in Marfan and Loeys-Dietz syndromes but remains understudied in Vascular Ehlers-Danlos syndrome. Methods and Results Subjects with a pathogenic COL3A1 variant diagnosed at age <50 years were included from 2 institutions and the GenTAC Registry (National Registry of Genetically Triggered Thoracic Aortic Aneurysms and Cardiovascular Conditions). Height-adjusted vertebral artery tortuosity index (VTI-h) using magnetic resonance or computed tomography angiography was calculated. Associations between VTI-h and outcomes of (1) cardiovascular events (arterial dissection/rupture, aneurysm requiring intervention, stroke), or (2) hollow organ collapse/rupture at age <50 years were evaluated using receiver operator curve analysis (using outcome by age 30 years) and mixed-effects Poisson regression for incidence rate ratios. Of 65 subjects (54% male), median VTI-h was 12 (interquartile range, 8-16). Variants were missense in 46%, splice site in 31%, and null/gene deletion in 14%. Thirty-two subjects (49%) had 59 events, including 28 dissections, 5 arterial ruptures, 4 aneurysms requiring intervention, 4 strokes, 11 hollow organ ruptures, and 7 pneumothoraces. Receiver operator curve analysis suggested optimal discrimination at VTI-h ≥15.5 for cardiovascular events (sensitivity 70%, specificity 76%) and no association with noncardiovascular events (area under the curve, 0.49 [95% CI, 0.22-0.78]). By multivariable analysis, older age was associated with increased cardiovascular event rate while VTI-h ≥15.5 was not (incidence rate ratios, 1.79 [95% CI, 0.76-4.24], P=0.185). However, VTI-h ≥15.5 was associated with events among those with high-risk variants <40 years (incidence rate ratios, 4.14 [95% CI, 1.13-15.10], P=0.032), suggesting effect modification by genotype and age. Conclusions Increased arterial tortuosity is associated with a higher incidence rate of cardiovascular events in Vascular Ehlers-Danlos syndrome. Vertebral tortuosity index may be a useful biomarker for prognosis when evaluated in conjunction with genotype and age.


Assuntos
Dissecção Aórtica , Síndrome de Ehlers-Danlos Tipo IV , Síndrome de Loeys-Dietz , Humanos , Masculino , Pessoa de Meia-Idade , Adulto , Feminino , Artérias
16.
Eur Heart J Cardiovasc Imaging ; 25(1): 18-26, 2023 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-37708373

RESUMO

AIMS: While transthoracic echocardiography (TTE) assessment of left ventricular end-diastolic pressure (LVEDP) is critically important, the current paradigm is subject to error and indeterminate classification. Recently, peak left atrial strain (LAS) was found to be associated with LVEDP. We aimed to test the hypothesis that integration of the entire LAS time curve into a single parameter could improve the accuracy of peak LAS in the noninvasive assessment of LVEDP with TTE. METHODS AND RESULTS: We retrospectively identified 294 patients who underwent left heart catheterization and TTE within 24 h. LAS curves were trained using machine learning (100 patients) to detect LVEDP ≥ 15 mmHg, yielding the novel parameter LAS index (LASi). The accuracy of LASi was subsequently validated (194 patients), side by side with peak LAS and ASE/EACVI guidelines, against invasive filling pressures. Within the validation cohort, invasive LVEDP was elevated in 116 (59.8%) patients. The overall accuracy of LASi, peak LAS, and American Society of Echocardiography/European Association for Cardiovascular Imaging (ASE/EACVI) algorithm was 79, 75, and 76%, respectively (excluding 37 patients with indeterminate diastolic function by ASE/EACVI guidelines). When the number of LASi indeterminates (defined by near-zero LASi values) was matched to the ASE/EACVI guidelines (n = 37), the accuracy of LASi improved to 87%. Importantly, among the 37 patients with ASE/EACVI-indeterminate diastolic function, LASi had an accuracy of 81%, compared with 76% for peak LAS. CONCLUSION: LASi allows the detection of elevated LVEDP using invasive measurements as a reference, at least as accurately as peak LAS and current diastolic function guideline algorithm, with the advantage of no indeterminate classifications in patients with measurable LAS.


Assuntos
Disfunção Ventricular Esquerda , Função Ventricular Esquerda , Humanos , Pressão Sanguínea , Estudos Retrospectivos , Átrios do Coração/diagnóstico por imagem , Ecocardiografia , Diástole , Disfunção Ventricular Esquerda/diagnóstico por imagem , Volume Sistólico , Pressão Ventricular
17.
J Am Heart Assoc ; 12(17): e029956, 2023 09 05.
Artigo em Inglês | MEDLINE | ID: mdl-37646214

RESUMO

Background Left ventricular (LV) global longitudinal strain (GLS) provides incremental prognostic information over LV ejection fraction in patients with heart failure (HF) and secondary mitral regurgitation. We examined the prognostic impact of LV GLS improvement in this population. Methods and Results The COAPT (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation) trial randomized symptomatic patients with HF with severe (3+/4+) mitral regurgitation to transcatheter edge-to-edge repair with the MitraClip device plus maximally tolerated guideline-directed medical therapy (GDMT) versus GDMT alone. LV GLS was measured at baseline and 6-month follow-up. The relationship between the improvement in LV GLS from baseline to 6 months and the composite of all-cause death or HF hospitalization between 6- and 24-month follow-up were assessed. Among 383 patients, 174 (45.4%) had improved LV GLS at 6-month follow-up (83/195 [42.6%] with transcatheter edge-to-edge repair+GDMT and 91/188 [48.4%] with GDMT alone; P=0.25). Improvement in LV GLS was strongly associated with reduced death or HF hospitalization between 6 and 24 months (P<0.009), with similar risk reduction in both treatment arms (Pinteraction=0.40). By multivariable analysis, LV GLS improvement at 6 months was independently associated with a lower risk of death or HF hospitalization (hazard ratio [HR], 0.55 [95% CI, 0.36-0.83]; P=0.009), death (HR, 0.48 [95% CI, 0.29-0.81]; P=0.006), and HF hospitalization (HR, 0.50 [95% CI, 0.31-0.81]; P=0.005) between 6 and 24 months. Conclusions Among patients with HF and severe mitral regurgitation in the COAPT trial, improvement in LV GLS at 6-month follow-up was associated with improved outcomes after both transcatheter edge-to-edge repair and GDMT alone between 6 and 24 months. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT01626079.


Assuntos
Insuficiência Cardíaca , Insuficiência da Valva Mitral , Humanos , Deformação Longitudinal Global , Insuficiência Cardíaca/terapia , Hospitalização , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Avaliação de Resultados em Cuidados de Saúde
18.
J Am Soc Echocardiogr ; 36(12): 1290-1301, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37574149

RESUMO

BACKGROUND: In patients with cardiac amyloidosis (CA), left ventricular ejection fraction (LVEF) is frequently preserved, despite commonly reduced global longitudinal strain (GLS). We hypothesized that nonlongitudinal contraction may initially serve as a mitigating mechanism to maintain cardiac output and studied the relationship between global circumferential (GCS) and radial (GRS) strain with LVEF and extracellular volume (ECV), a marker of amyloid burden. METHODS: Patients with CA who underwent cardiac magnetic resonance (CMR; n = 140, 70.7 ± 11.5 years, 66% male) or echocardiography (n = 67, 71 ± 13 years, 66% male) and normal controls (CMR, n = 20; echocardiography, n = 45) were retrospectively identified, and GCS, GLS, and GRS were quantified using feature-tracking CMR or speckle-tracking echocardiography and compared between CA patients with preserved and reduced LVEF (CAHFpEF, CAHFrEF) and controls. The prevalence of impaired strain (magnitudes <2.5th percentile of the controls) was compared between CAHFpEF and CAHFrEF and between ECV quartiles. RESULTS: While echocardiography-derived GLS was impaired in both CAHFpEF (-13.4% ± 3.1%, P < .003) and CAHFrEF (-9.1% ± 3.2%, P < .003), compared with controls (-20.8% ± 2.4%), GCS was more impaired in CAHFrEF compared with both controls (-15.6% ± 5.0% vs -32.3% ± 3.3%, P < .003) and CAHFpEF (-30.4% ± 5.7%, P < .003) and did not differ between CAHFpEF and controls (P = .24). The prevalence of abnormal CMR-derived GCS (P < .0001) and GRS (P < .0001) but not GLS (P = .054) varied significantly across ECV quartiles. CONCLUSIONS: Among CA patients with preserved LVEF, preserved GCS and GRS, despite near-universally impaired GLS, may be explained by an initial predominantly subendocardial involvement, where mostly longitudinal fibers are located. If confirmed in future studies, these findings may facilitate identification of patients with early stages of CA, when treatments may be most effective.


Assuntos
Amiloidose , Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Humanos , Masculino , Feminino , Função Ventricular Esquerda , Volume Sistólico , Estudos Retrospectivos , Amiloidose/complicações , Amiloidose/diagnóstico , Imagem Cinética por Ressonância Magnética , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia , Valor Preditivo dos Testes
19.
J Am Coll Cardiol ; 82(2): 128-138, 2023 07 11.
Artigo em Inglês | MEDLINE | ID: mdl-37306651

RESUMO

BACKGROUND: Although malnutrition is associated with poor prognosis in several diseases, its prognostic impact in patients with heart failure (HF) and secondary mitral regurgitation (SMR) is not understood. OBJECTIVES: The purpose of this study was to assess the prevalence and impact of malnutrition in HF patients with severe SMR randomized to transcatheter edge-to-edge repair (TEER) with the MitraClip plus guideline-directed medical therapy (GDMT) vs GDMT alone in the COAPT trial. METHODS: Baseline malnutrition risk was calculated using the validated geriatric nutritional risk index (GNRI) score. Patients were categorized as having "malnutrition" (GNRI ≤98) vs "no malnutrition" (GNRI >98). Outcomes were assessed through 4 years. The primary endpoint of interest was all-cause mortality. RESULTS: Among 552 patients, median baseline GNRI was 109 (IQR: 101-116); 94 (17.0%) had malnutrition. All-cause mortality at 4 years was greater in patients with vs those without malnutrition (68.3% vs 52.8%; P = 0.001). Using multivariable analysis, both baseline malnutrition (adjusted-HR [adj-HR]: 1.37; 95% CI: 1.03-1.82; P = 0.03) and randomization to TEER plus GDMT compared with GDMT alone (adj-HR: 0.65; 95% CI: 0.51-0.82; P = 0.0003) were independent predictors of 4-year mortality. In contrast, GNRI was unrelated to the 4-year rate of heart failure hospitalization (HFH), although TEER treatment reduced HFH (adj-HR: 0.46; 95% CI: 0.36-0.56). The reductions in death (adj-Pinteraction = 0.46) and HFH (adj-Pinteraction = 0.67) with TEER were consistent in patients with and without malnutrition. CONCLUSIONS: Malnutrition was present in 1 of 6 patients with HF and severe SMR enrolled in COAPT and was independently associated with increased 4-year mortality (but not HFH). TEER reduced mortality and HFH in patients with and without malnutrition. (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation [The COAPT Trial] and COAPT CAS [COAPT]; NCT01626079).


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Idoso , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/epidemiologia , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Prognóstico , Avaliação de Resultados em Cuidados de Saúde , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Resultado do Tratamento
20.
JACC Cardiovasc Interv ; 16(12): 1463-1473, 2023 06 26.
Artigo em Inglês | MEDLINE | ID: mdl-37380228

RESUMO

BACKGROUND: The fourth-generation MitraClip G4 System builds on the previous NTR/XTR system with additional wider clip sizes (NTW and XTW), an independent grasping feature, and an improved clip deployment sequence. OBJECTIVES: The primary objective of this study was to assess the safety and performance of the MitraClip G4 System within a contemporary real-world setting. METHODS: EXPAND G4 is a prospective, multicenter, international, single-arm, postapproval study that enrolled patients with primary (degenerative) mitral regurgitation (MR) and secondary (functional) MR at 60 centers. Follow-up of the full cohort has been conducted through 30 days. Echocardiograms were analyzed by an echocardiography core laboratory. Study outcomes included MR severity, functional capacity measured by NYHA functional class, quality of life measured using the Kansas City Cardiomyopathy Questionnaire, major adverse event rates, and all-cause mortality. RESULTS: In EXPAND G4, 1,141 subjects with primary MR and secondary MR were treated from March 2021 to February 2022. Implantation and acute procedural success rates were 98.0% and 96.2%, respectively, with a mean of 1.4 ± 0.6 clips implanted per subject. MR was significantly reduced at 30 days compared with baseline (98% achieved MR ≤ 2+, and 91% achieved MR ≤ 1+; P < 0.0001). Functional capacity and quality of life were substantially improved, with 83% of patients achieving NYHA functional class I or II. Likewise, an 18-point improvement was observed in Kansas City Cardiomyopathy Questionnaire summary scores compared with baseline. The composite major adverse event rate was 2.7%, and the all-cause death rate was 1.3% at 30 days. CONCLUSIONS: This study demonstrates for the first time the effectiveness and safety of MitraClip G4 System at 30 days in a cohort of >1,000 patients with MR in a contemporary, real-world setting.


Assuntos
Cardiomiopatias , Insuficiência da Valva Mitral , Humanos , Estudos Prospectivos , Qualidade de Vida , Resultado do Tratamento , Ecocardiografia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...