Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38745522

RESUMO

BACKGROUND: Evidence on management of behavioral symptoms in motor neuron disease (MND) is lacking. The MiNDToolkit, an online psychoeducational platform, supports carers dealing with behavioral symptoms (BehSymp). The study objectives were to ascertain recruitment and retention rates, carer and healthcare professional (HCP) use of the platform, and completion of online assessments, to inform a full-scale trial. Design: Randomized, parallel, multi-center, feasibility trial. SETTING: England and Wales, across diverse MND services; recruitment from July/21 to November/22; last participant follow-up in March/23. PARTICIPANTS: Carers of people with motor neuron disease (PwMND) with BehSymp, recruited through MND services. After confirming eligibility, participants completed screening and baseline assessments online via the MiNDToolkit platform and were randomized centrally in a 1:1 ratio to MiNDToolkit or control. INTERVENTION: MiNDToolkit offered tailored modules to carers for the 3-month study period. Carers in the intervention group could receive additional support from MiNDToolkit trained HCPs. The control group was offered access to the intervention at the end of the study. Data were collected on platform usage and psychosocial variables. MAIN OUTCOMES: One hundred and fifty-one carers from 11 sites were invited to join the study (letter, face-to-face); 30 were screened; 29 were randomized. Fifteen people were allocated to the control arm; 14 to intervention. Carers were mostly female; median age for was 62.5 (IQR: 58, 68; intervention) and 57 (IQR: 56, 70; controls). Study retention was high (24/29 = 82.76%); carers engaged with the platform on average 14 times (median (IQR):14.0 (10.0, 18.5)) during the study period. CONCLUSION: The MiNDToolkit study was feasible and well accepted by carers and trained HCPs. A definitive trial is warranted.

2.
Sci Rep ; 10(1): 16471, 2020 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-33020502

RESUMO

SARS-CoV-2 has a zoonotic origin and was transmitted to humans via an undetermined intermediate host, leading to infections in humans and other mammals. To enter host cells, the viral spike protein (S-protein) binds to its receptor, ACE2, and is then processed by TMPRSS2. Whilst receptor binding contributes to the viral host range, S-protein:ACE2 complexes from other animals have not been investigated widely. To predict infection risks, we modelled S-protein:ACE2 complexes from 215 vertebrate species, calculated changes in the energy of the complex caused by mutations in each species, relative to human ACE2, and correlated these changes with COVID-19 infection data. We also analysed structural interactions to better understand the key residues contributing to affinity. We predict that mutations are more detrimental in ACE2 than TMPRSS2. Finally, we demonstrate phylogenetically that human SARS-CoV-2 strains have been isolated in animals. Our results suggest that SARS-CoV-2 can infect a broad range of mammals, but few fish, birds or reptiles. Susceptible animals could serve as reservoirs of the virus, necessitating careful ongoing animal management and surveillance.


Assuntos
Peptidil Dipeptidase A/química , Filogenia , Glicoproteína da Espícula de Coronavírus/química , Enzima de Conversão de Angiotensina 2 , Animais , Betacoronavirus/classificação , Betacoronavirus/genética , Humanos , Mamíferos , Simulação de Acoplamento Molecular , Mutação , Peptidil Dipeptidase A/classificação , Peptidil Dipeptidase A/genética , Peptidil Dipeptidase A/metabolismo , Ligação Proteica , SARS-CoV-2 , Glicoproteína da Espícula de Coronavírus/metabolismo
3.
Hum Reprod Open ; 2019(2): hoz005, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30949588

RESUMO

Medical products of human origin (MPHO) distributed for use in assisted reproduction are currently labelled and identified using national or local systems. Products may be distributed internationally with potentially confusing identification labelling due to inconsistent terminology and definitions. In other fields of MPHO activity terminology has previously been standardized through professional collaboration as a precursor to adoption of a global standard for identification, coding and labelling. The International Council for Commonality in Blood Bank Automation (ICCBBA), an international nongovernmental organization in official relations with the World Health Organization, brought together representatives from professional societies to develop a terminology using a well-established methodology. The terminology was reviewed by professional associations and released for public comment. Further refinements were made following the comment period. Representatives of the American Society for Reproductive Medicine (ASRM), ESHRE, the Reproductive Tissue Council of the American Association of Tissue Banks (AATB) and ICCBBA met by international conference call and interacted by email. The terminology was developed using a standard model previously used across many areas of MPHO. A terminology comprising six classes, and six attribute groups has been developed. The terminology design is such that additional classes, attribute groups and attribute values can be added to meet the developing needs of the ART community. The level of detail incorporated into the terminology is based on the consensus view of the experts. The objective has been to provide sufficient detail to satisfy clinical need in product identification but there is the possibility that the level of detail may need to be adjusted in the future. The terminology is designed in a way that can readily accommodate such adjustments. Adoption of a standard terminology provides the basis for standardization of identification, coding and labelling and the use of internationally standardized barcoding to improve the accuracy and efficiency of information transfer and to reduce the risks of harm due to manual transcriptions errors.

7.
Vox Sang ; 98(1): 85-6, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20017864

RESUMO

A survey of blood centre organizations was carried out to establish the degree of progress towards the implementation of global standards for coding and labelling blood components. The survey was performed through questionnaires completed by blood organizations. Of nearly 32 million blood donations collected annually by the participants, 43% are identified with ISBT 128 donation numbers and 36% are fully compliant with the ISBT 128 Standard. Planned implementations indicate that 85% of donations will be identified by ISBT 128 donation numbers by 2011.


Assuntos
Armazenamento de Sangue/métodos , Doadores de Sangue , Fidelidade a Diretrizes , Bancos de Sangue/normas , Transfusão de Componentes Sanguíneos , Processamento Eletrônico de Dados , Humanos , Rotulagem de Produtos , Inquéritos e Questionários
8.
Bone Marrow Transplant ; 40(11): 1085-90, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17906707

RESUMO

The publication of new standards for terminology and labeling marks an important step in ensuring consistency and traceability of cellular therapies at the global level. However, it is only with the widespread implementation of the standard that the benefits can be truly realized. This paper provides guidance on the practical aspects of adopting these new standards for organizations with differing current levels of computerization. It discusses project management, equipment, licensing, and validation topics.


Assuntos
Transplante de Células/normas , Cooperação Internacional , Organizações , Rotulagem de Produtos , Processamento Eletrônico de Dados/normas , Humanos , Organizações/organização & administração , Organizações/normas , Rotulagem de Produtos/métodos , Rotulagem de Produtos/normas , Terminologia como Assunto
9.
Bone Marrow Transplant ; 40(11): 1075-83, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17906708

RESUMO

The International Cellular Therapy Coding and Labeling Advisory Group was established to address the growing need for standardization of terminology and labeling for cellular therapy products as a result of increasing international transfer of these products. This paper presents new standards for terminology and labeling. These standards have been developed through a consultative process and are supported by key professional and accreditation bodies. By using these standards, together with the unique donation identification numbers and international product reference tables provided by the International Society of Blood Transfusion (ISBT) 128 Standard, consistency and traceability can be assured at the global level. A companion paper provides guidance on the implementation of the ISBT 128 system.


Assuntos
Transplante de Células/normas , Rotulagem de Produtos/normas , Terminologia como Assunto , Células Sanguíneas/classificação , Remoção de Componentes Sanguíneos/classificação , Processamento Eletrônico de Dados/normas , Humanos , Células-Tronco/classificação
12.
Vox Sang ; 49(5): 315-8, 1985.
Artigo em Inglês | MEDLINE | ID: mdl-4082528

RESUMO

Spontaneous formation of clotted material occurs occasionally in all stored red cell units, but larger amounts have been noted in SAG-M optimal additive suspensions. These can be substantially reduced by substitution of the SAG-M solution by a SAG-M/CPDA-1 mixture suggesting that there is insufficient citrate in SAG-M red cell suspensions to completely inhibit coagulation of the residual plasma.


Assuntos
Coleta de Amostras Sanguíneas/métodos , Coagulação Sanguínea , Coleta de Amostras Sanguíneas/normas , Transfusão de Sangue , Hemólise , Humanos , Soluções
13.
Vox Sang ; 49(2): 121-5, 1985.
Artigo em Inglês | MEDLINE | ID: mdl-3929472

RESUMO

A study of automated anti-D quantitation on untreated and dithiothreitol (DTT) pre-treated plasma has been undertaken. The results indicate that in most cases pre-treatment of plasma with DTT causes a reduction in the anti-D level detected. In one case such treatment caused the anti-D level to fall to less than 50% of its original value. DTT treatment prior to quantitation may give a more accurate assessment of the IgG anti-D level present in plasma and thus be of assistance in the selection of suitable plasma for anti-D immunoglobulin preparation. The technique may also have applications in the diagnosis and management of haemolytic disease of the newborn.


Assuntos
Ditiotreitol , Isoanticorpos/análise , Plasma/imunologia , Sistema do Grupo Sanguíneo Rh-Hr/imunologia , Eritroblastose Fetal/diagnóstico , Feminino , Humanos , Imunoglobulina G/análise , Imunoglobulina M/análise , Recém-Nascido , Gravidez
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...