Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Cardiothorac Surg ; 19(1): 203, 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38615049

RESUMO

BACKGROUND: Open arch surgery is technically demanding for the surgeon and surgically and biologically invasive for the patient, requiring a variably long period of hypothermic circulatory arrest. CASE PRESENTATION: Here we present a case of an elderly patient with chronic renal failure and multiple splanchnic artery disease successfully treated for a rupturing pseudoaneurysm of the aortic arch with a technique that we developed for particularly frail patients. The procedure includes: triple supra-aortic vessel perfusion; distal thoracic aorta antegrade perfusion; balloon endo-clamping of the descending aorta; and anastomosis of an off-the-shelf hybrid arch prosthesis in Ishimaru zone 0. These maneuvers allowed to maintain an extracorporeal circulation in the phase of distal anastomosis, instead of a period of circulatory arrest, employing just mild hypothermia: technical details are depicted and discussed also in comparison with other methods proposed in the literature. CONCLUSIONS: Being able to take advantage of both open surgery advancements and endovascular methods is the key to cardiovascular surgery success today in front of complex pathologies of the aorta: increasing safety and reducing invasiveness of therapeutic options may progressively extend surgical candidacy to the frailest patients.


Assuntos
Implante de Prótese Vascular , Parada Cardíaca , Idoso , Humanos , Aorta Torácica/cirurgia , Aorta , Perfusão
2.
Eur J Cardiothorac Surg ; 60(6): 1388-1394, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34008022

RESUMO

OBJECTIVES: Our goal was to investigate whether the incidence of valve-related adverse events might be different depending on the valve substitute after valve replacement for left-sided native valve endocarditis. METHODS: We assessed the long-term freedom from recurrence, reoperation and survival of 395 patients who had valve replacements for native valve endocarditis (314 mechanical vs 81 biological). Age <18 years, reoperation, prosthetic endocarditis, right valve involvement, valve repair and homograft implants were the main exclusion criteria. The balance between the 2 groups was addressed by weighting the results on the inverse of the propensity score. RESULTS: After inverse probability of treatment weighting (IPTW), freedom from recurrence of infective endocarditis was not significantly different (mechanical 84.1 ± 3.2% vs 50.6 ± 21.7%; P = 0.29) nor was freedom from reoperation different (mechanical 85.7 ± 3.1% vs biological 50.9 ± 21.9%; P = 0.29). Excluding competing deaths, patients receiving a bioprosthesis had a similar subdistribution hazard of the above end points compared to recipients of a mechanical valve [recurrence IPTW: hazard ratio (HR) 1.631, 95% confidence interval (CI) 0.756-3.516; P = 0.21; reoperation IPTW-HR 1.737, 95% CI 0.780-3.870; P = 0.18]. Mechanical valves were associated with improved long-term survival (34.9 ± 5.8% vs 10.5 ± 7.4% at 30 years; P = 0.0009; in particular: aortic valve subgroup 41.6 ± 9.3% vs 10.1 ± 8.2%; P < 0.0001), although the hazard of cardiovascular mortality did not favour either valve type (IPTW: HR 1.361, 95% CI 0.771-2.404; P = 0.29). CONCLUSIONS: Our analysis showed a clinical trend in favour of mechanical valves as valve substitutes for native valve endocarditis, especially in the aortic position. In view of long-term freedom from adverse events, the choice of the valve type should be tailored according to patient characteristics and specific clinical conditions.


Assuntos
Bioprótese , Endocardite , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Adolescente , Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Endocardite/epidemiologia , Endocardite/etiologia , Endocardite/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Recidiva , Reoperação/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
3.
Curr Probl Cardiol ; 46(3): 100428, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31296418

RESUMO

The current management of aortic dilatation associated with congenital bicuspid aortic valve (bicuspid aortic valve aortopathy) is based on dimensional parameters (diameter of the aneurysm, growth of the diameter over time) and few other criteria. The disease is however heterogeneous in terms of natural and clinical history and risk of acute complications, ie aortic dissection. Dimensional criteria are now admitted to have limited value as predictors of such complications. Thus, novel principles for risk stratification have been recently investigated, including phenotypic criteria, flow-related metrics, and circulating biomarkers. A systematization of the typical anatomoclinical forms that the aortopathy can assume has led to the identification of the more severe root phenotype, associated with higher risk of progression of the aneurysm and possible higher aortic dissection risk. Four-dimensional-flow magnetic resonance imaging studies are searching for potentially clinically significant metrics of flow derangement, based on the recognized association of local abnormal shear stress with wall pathology. Other research initiatives are addressing the question whether circulating molecules could predict the presence or, more importantly, the future development of aortopathy. The present review summarizes the latest progresses in the knowledge on risk stratification of bicuspid aortic valve aortopathy, focusing on critical aspects and debated points.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/patologia , Humanos , Medição de Risco
4.
Ultrasound Med Biol ; 44(6): 1198-1211, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29609808

RESUMO

Our aim was to analyze atrial function with 2-D (2-D-STE) and 3-D (3-D-STE) speckle tracking echocardiography in patients with atrial septal devices and paroxysmal atrial fibrillation (PAF). One hundred sixteen patients and a subgroup of 22 patients who developed PAF after device insertion were studied. Left atrial and right atrial peak longitudinal strain and standard deviations of time to peak strain (TPS) were calculated using 2-D-STE. The left atrial/right atrial emptying fraction and expansion index were determined using 3-D-STE. By multivariate analysis, pre-closure 3-D right atrial expansion index, left atrial time to peak strain, and 3-D left atrial expansion index were independently associated with PAF. Compared with the other indices, receiver operating characteristic analysis revealed better diagnostic accuracy for the combination of pre-closure time to peak strain and 3-D expansion index in detecting PAF. Patients with atrial septal devices have pre-existing left and right atrial dilation and dysfunction as assessed by 2-D-STE and 3-D-STE that appear sensitive for the stratification of PAF risk in this population.


Assuntos
Fibrilação Atrial/fisiopatologia , Função Atrial , Septo Interatrial/cirurgia , Ecocardiografia/métodos , Cardiopatias Congênitas/cirurgia , Adulto , Ecocardiografia Tridimensional/métodos , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes
5.
J Am Soc Echocardiogr ; 28(9): 1070-82, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25982249

RESUMO

BACKGROUND: The goal of this study was to determine changes in left ventricular (LV) and right ventricular (RV) function with three-dimensional (3D) speckle-tracking echocardiography (STE) after percutaneous mitral valve repair with the MitraClip system in high-risk surgical patients with moderate to severe or severe secondary mitral regurgitation (MR). METHODS: Thirty-two patients with MR undergoing MitraClip were prospectively included. Patients underwent two-dimensional (2D) and 3D transthoracic echocardiography before clip implantation and after 6-month follow-up. LV and RV longitudinal strain was obtained by 2D STE and 3D STE. LV circumferential, radial, and area strain was calculated by 3D STE. Data analysis was performed offline. RESULTS: At 6-month follow-up, significant improvements were seen in LV 2D global longitudinal strain (P < .005), 3D global longitudinal strain (P = .0002), and 3D area strain (P = .0001). Overall, significant improvements were also seen in 3D RV ejection fraction (P < .05) and 3D RV free-wall longitudinal strain (P < .05). A poor increase in LV strain after clip implantation (P = NS) occurred in patients with pronounced preexisting RV dysfunction. The areas under the receiver operating characteristic curves for LV and RV 3D speckle-tracking echocardiographic parameters showed high discriminative values (range, 0.87-0.91) in predicting unfavorable outcomes with persistent symptoms (New York Heart Association class > II) after the procedure. CONCLUSIONS: Three-dimensional STE showed overall LV and RV strain improvement after clip implantation as well as lower postprocedural LV strain values in patients with worse preexisting RV function. These findings could help in guiding MR treatment strategies, suggesting different therapies in the presence of marked RV impairment or anticipating the procedure in case of evolving RV dysfunction.


Assuntos
Ecocardiografia Tridimensional/métodos , Implante de Prótese de Valva Cardíaca/instrumentação , Ventrículos do Coração/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico por imagem , Função Ventricular Esquerda/fisiologia , Função Ventricular Direita/fisiologia , Idoso , Desenho de Equipamento , Feminino , Seguimentos , Ventrículos do Coração/fisiopatologia , Humanos , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Período Pós-Operatório , Prognóstico , Desenho de Prótese , Curva ROC , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Fatores de Tempo
6.
J Am Heart Assoc ; 4(3): e001584, 2015 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-25792128

RESUMO

BACKGROUND: Our aim was to compare three-dimensional (3D) and 2D and 3D speckle-tracking (2D-STE, 3D-STE) echocardiographic parameters with conventional right ventricular (RV) indexes in patients with chronic pulmonary hypertension (PH), and investigate whether these techniques could result in better correlation with hemodynamic variables indicative of heart failure. METHODS AND RESULTS: Seventy-three adult patients (mean age, 53±13 years; 44% male) with chronic PH of different etiologies were studied by echocardiography and cardiac catheterization (25 precapillary PH from pulmonary arterial hypertension, 23 obstructive pulmonary heart disease, and 23 postcapillary PH from mitral regurgitation). Thirty healthy subjects (mean age, 54±15 years; 43% male) served as controls. Standard 2D measurements (RV-fractional area change-tricuspid annular plane systolic excursion) and mitral and tricuspid tissue Doppler annular velocities were obtained. RV 3D volumes and global and regional ejection fraction (3D-RVEF) were determined. RV strains were calculated by 2D-STE and 3D-STE. RV 3D global-free-wall longitudinal strain (3DGFW-RVLS), 2D global-free-wall longitudinal strain (GFW-RVLS), apical-free-wall longitudinal strain, basal-free-wall longitudinal strain, and 3D-RVEF were lower in patients with precapillary PH (P<0.0001) and postcapillary PH (P<0.01) compared to controls. 3DGFW-RVLS (hazard ratio 4.6, 95% CI 2.79 to 8.38, P=0.004) and 3D-RVEF (hazard ratio 5.3, 95% CI 2.85 to 9.89, P=0.002) were independent predictors of mortality. Receiver operating characteristic curves showed that the thresholds offering an adequate compromise between sensitivity and specificity for detecting hemodynamic signs of RV failure were 39% for 3D-RVEF (AUC 0.89), -17% for 3DGFW-RVLS (AUC 0.88), -18% for GFW-RVLS (AUC 0.88), -16% for apical-free-wall longitudinal strain (AUC 0.85), 16 mm for tricuspid annular plane systolic excursion (AUC 0.67), and 38% for RV-FAC (AUC 0.62). CONCLUSIONS: In chronic PH, 3D, 2D-STE and 3D-STE parameters indicate global and regional RV dysfunction that is associated with RV failure hemodynamics better than conventional echo indices.


Assuntos
Ecocardiografia Doppler , Ecocardiografia Tridimensional , Insuficiência Cardíaca/diagnóstico por imagem , Hemodinâmica , Hipertensão Pulmonar/diagnóstico por imagem , Disfunção Ventricular Direita/diagnóstico por imagem , Função Ventricular Direita , Adulto , Idoso , Área Sob a Curva , Cateterismo Cardíaco , Estudos de Casos e Controles , Doença Crônica , Feminino , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Hipertensão Pulmonar/complicações , Hipertensão Pulmonar/mortalidade , Hipertensão Pulmonar/fisiopatologia , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Curva ROC , Fatores de Risco , Disfunção Ventricular Direita/etiologia , Disfunção Ventricular Direita/mortalidade , Disfunção Ventricular Direita/fisiopatologia
7.
Medicine (Baltimore) ; 93(12): e71, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25211047

RESUMO

Dyslipidemia and obesity are considered strong risk factors for premature atherosclerotic cardiovascular disease and increased morbidity and mortality and may have a negative impact on myocardial function.Our purpose was to assess the presence of early myocardial deformation abnormalities in dyslipidemic children free from other cardiovascular risk factors, using 2-dimensional speckle tracking echocardiography (2DSTE) and 3-dimensional speckle tracking echocardiography (3DSTE).We studied 80 consecutive nonselected patients (6-18 years of age) with hypercholesterolemia (low-density lipoprotein [LDL] cholesterol levels >95th percentile for age and sex). Forty of them had normal weight and 40 were obese (body mass index >95th percentile for age and sex). Forty healthy age-matched children were selected as controls. Left ventricular (LV) global longitudinal, circumferential, and radial strains were calculated by 2DSTE and 3DSTE. Global area strain (GAS) was calculated by 3DSTE as percentage of variation in surface area defined by the longitudinal and circumferential strain vectors. Right ventricular (RV) global and free-wall longitudinal strain and LV and RV diastolic strain rate parameters were obtained. Data analysis was performed offline.LV global longitudinal strain and GAS were lower in normal-weight and obese dyslipidemic children compared with normal controls and reduced in obese patients compared with normal-weight dyslipidemic children. LV early diastolic strain rate was lower compared with normals. RV global and free-wall longitudinal strain was significantly reduced in obese patients when compared with the control group. A significant inverse correlation was found between LV strain, LDL cholesterol levels, and body mass index.2DSTE and 3DSTE show LV longitudinal strain and GAS changes in dyslipidemic children and adolescents free from other cardiovascular risk factors or structural cardiac abnormalities. Obesity causes an additive adverse effect on LV strain parameters and RV strain impairment.


Assuntos
Ecocardiografia Tridimensional , Ecocardiografia , Hipercolesterolemia/complicações , Miocárdio/patologia , Obesidade/complicações , Adolescente , Índice de Massa Corporal , Estudos de Casos e Controles , Criança , LDL-Colesterol/sangue , Comorbidade , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Humanos , Hipercolesterolemia/sangue , Masculino
8.
Eur Heart J Cardiovasc Imaging ; 15(12): 1377-85, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25139906

RESUMO

AIMS: Percutaneous closure of patent foramen ovale (PFO) in cryptogenic cerebrovascular events is an alternative to medical therapy. The interpretation of residual shunts after implantation of different devices for PFO with different morphologies is controversial. METHODS AND RESULTS: Transcatheter PFO closure was performed in 123 patients with a history of ≥1 paradoxical embolism using three different devices: Amplatzer (n = 46), Figulla Occlutech (n = 41), and Atriasept Cardia (n = 36). Fifty-six patients presented with simple PFO and 67 patients had complex morphologies. All patients were studied with contrast enhanced transesophageal echocardiography (TEE) before interventional procedure and thereafter at 1 and 6 months and every 6-12 months in case of incomplete closure. Definite closure was confirmed in at least two consecutive TEE studies. Various PFO morphologies were identified by TEE before device implantation. The device size to PFO diameter ratio was significantly increased in patients with complex PFO compared with those patients with a simple PFO morphology (P < 0.05). The difference between the closure rate of S-PFO and C-PFO concerning each device type was significant (Amplatzer P = 0.0027, Figulla P = 0.0043, and Atriasept P < 0.01). The mean follow-up period was 3.4 years (median 2.7 years) with a cerebrovascular re-event rate of 2.4% per year. In three patients, thrombi were detected in the 6-month TEE controls and resolved after medical therapy. In three other patients, the implantation of an adjunctive device was necessary for residual shunt. CONCLUSION: In our series of patients, the closure rate was dependent on PFO morphology more than occluder size and type. An adjunctive device was implanted in selected cases.


Assuntos
Cateterismo Cardíaco , Ecocardiografia Transesofagiana/métodos , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/terapia , Implante de Prótese de Valva Cardíaca , Ultrassonografia de Intervenção , Adulto , Idoso , Meios de Contraste , Feminino , Seguimentos , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade , Fatores de Tempo , Resultado do Tratamento
9.
J Am Soc Echocardiogr ; 27(3): 329-38, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24325961

RESUMO

BACKGROUND: The aim of this study was to assess changes in right ventricular (RV) parameters determined by three-dimensional (3D) echocardiography and speckle-tracking echocardiography in patients with acute pulmonary embolism and RV dysfunction without systemic hypotension (submassive pulmonary embolism). METHODS: Sixty-six patients were prospectively studied at the onset of the acute episode and after median follow-up periods of 30 days and 6 months. Sixty-six controls were selected. RV fractional area change, tricuspid annular plane systolic excursion, and myocardial performance index were determined. RV systolic pressure was assessed using continuous-wave Doppler echocardiography. Three-dimensional RV ejection fraction (RVEF) was calculated. Two-dimensional peak systolic RV longitudinal strain (RVLS) was measured in the basal free wall, mid free wall (MFW), and apical free wall and the septum. RESULTS: Tricuspid annular plane systolic excursion and fractional area change were smaller and myocardial performance index was larger compared with controls (P < .05). Global RVLS (P < .05), MFW RVLS (P < .001), and 3D RVEF (P < .001) were lower in patients with pulmonary embolism than in controls. There was earlier reversal of MFW RVLS values on 30-day follow-up and longer reversal of 3D RVEF and RV systolic pressure values at 6-month follow-up. Receiver operating characteristic curve analysis showed that changes in 3D RVEF and MFW RVLS were the most sensitive predictors of adverse events. By multivariate analysis, RV systolic pressure (P = .007), MFW RVLS (P = .002), and 3D RVEF (P = .001) were independently associated with adverse outcomes. CONCLUSIONS: Acute submassive pulmonary embolism has a significant impact on RV function as assessed by 3D echocardiography and speckle-tracking echocardiography. Decreases in MFW RVLS and 3D RVEF may persist during short-term and long-term follow-up and correlate with unfavorable outcomes.


Assuntos
Ecocardiografia Tridimensional/métodos , Técnicas de Imagem por Elasticidade/métodos , Imagem Multimodal/métodos , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/fisiopatologia , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/fisiopatologia , Doença Aguda , Módulo de Elasticidade , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Embolia Pulmonar/complicações , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estresse Mecânico , Disfunção Ventricular Direita/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...