Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
2.
J Matern Fetal Neonatal Med ; 32(23): 3980-3985, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29788801

RESUMO

Purpose: Spinal anesthesia is considered the gold standard anesthetic technique for cesarean deliveries (CDs) but is associated with a high rate of hypotension. The recent international consensus recommends continuous prophylactic phenylephrine infusion (PPI) administered throughout CD to prevent hypotension. However, little information is available on the hemodynamic profiles of women with twin pregnancies as compared to singleton pregnancies perioperatively. Therefore, in this study, we aim to compare maternal hemodynamic changes both intraoperatively and postoperatively with the use of the NICAS bioimpendence monitor in healthy singleton versus twin parturients undergoing CD deliveries with spinal anesthesia with PPI. Materials and methods: After IRB approval and signed informed consent, healthy term women with either twin or singleton pregnancies undergoing spinal anesthesia for uncomplicated CD were enrolled. The following data were collected - cardiac output (CO), stroke volume (SV), mean arterial pressure (MAP), and total peripheral resistance (TPR). Measurements were measured at five time points: (1) before arrival in OR, (2) after spinal anesthesia with PPI, (3) after beginning of oxytocin infusion, (4) in post anesthesia care room, (5) 24 hours postoperatively, and (6) 48 hours postoperatively. All parturients received standardized spinal solution consisting of 12 mg hyperbaric bupivacaine, 20 µg fentanyl and 100-µg preservative-free morphine. PPI administered was titrated to preserve blood pressure to 20% of baseline blood pressure and stopped at the end of surgery. Oxytocin was administered as a continuous infusion (20-units/1000 cm3 Ringer's lactate) at a rate of 100 cm3/h. Results: One hundred and thirty seven parturients with singleton pregnancies and 27 parturients with twin pregnancies completed the study. There were no significant differences between groups in age or BMI. Intraoperatively, there was no difference in any hemodynamic parameter. However, postoperatively at all three times women with twin pregnancies had higher MAP, lower CO and higher TPR compared with parturients with singleton pregnancies. Conclusions: There were significant hemodynamic changes postoperatively but not intraoperatively in parturients with twin pregnancies compared to women with singleton pregnancies. These changes need to be further investigated.


Assuntos
Anestesia Obstétrica/métodos , Débito Cardíaco/efeitos dos fármacos , Cesárea/métodos , Hipotensão/prevenção & controle , Monitorização Intraoperatória/métodos , Fenilefrina/administração & dosagem , Adulto , Raquianestesia , Débito Cardíaco/fisiologia , Quimioprevenção/métodos , Estudos de Coortes , Feminino , Hemodinâmica/efeitos dos fármacos , Humanos , Hipotensão/fisiopatologia , Recém-Nascido , Infusões Intravenosas , Parto/efeitos dos fármacos , Parto/fisiologia , Período Perioperatório , Gravidez , Gravidez de Gêmeos , Vasoconstritores/administração & dosagem
3.
Arch Gynecol Obstet ; 297(6): 1405-1413, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29453654

RESUMO

PURPOSE: Uterine activity plays a crucial role in labor, especially when utero-tonic materials are administered. We aimed to determine the electrical responsiveness of the uterine musculature to labor augmentation with oxytocin using electrical uterine myography (EUM) technology, and to assess whether the kinetics of the EUM device may serve as a predictor for successful vaginal delivery. METHODS: EUM prospectively measured electrical uterine activity in women with singleton gestations at term (≥ 37 + 0 weeks) undergoing labor augmentation by oxytocin administration. The results were reported as the EUM index, which represented the mean electrical activity in 10-min intervals and measured in units of microwatt per second (mW/s). Measurements were performed at least 30 min before oxytocin initiation and until at least four contractions per 10 min were recorded by standard tocodynamometry. The delta EUM index was defined as the difference between the mean EUM index before and after the initiation of oxytocin. RESULTS: The mean EUM index increased significantly during oxytocin augmentation in all the parturients (P < 0.001). Mean and minimum (but not maximum) uterine electrical activity during oxytocin infusion correlated with the baseline uterine activity. The delta EUM index was not significantly affected by demographic or obstetric parameters. There was no correlation between the delta EUM index and time to delivery or the mean EUM index during oxytocin administration and time to delivery. CONCLUSIONS: Uterine electrical activity as evaluated by EUM is significantly intensified following oxytocin administration, regardless of obstetrical characteristics, and is correlated with the baseline uterine electrical activity prior to oxytocin infusion.


Assuntos
Eletromiografia/métodos , Miométrio/fisiologia , Ocitocina/administração & dosagem , Tocolíticos/farmacologia , Contração Uterina/efeitos dos fármacos , Monitorização Uterina , Útero/efeitos dos fármacos , Adulto , Feminino , Humanos , Trabalho de Parto Induzido/métodos , Trabalho de Parto , Ocitocina/farmacologia , Gravidez , Estudos Prospectivos , Tocolíticos/uso terapêutico , Contração Uterina/metabolismo , Útero/fisiologia
4.
J Perinatol ; 37(12): 1285-1291, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-28906497

RESUMO

OBJECTIVE: The sonographic prediction of fetal macrosomia affects obstetrical decision regarding the timing and mode of delivery. We aimed to compare the accuracy of various formulas for prediction of macrosomia at different thresholds. STUDY DESIGN: This was a retrospective cohort study of singleton gestations at term, with fetal biometrical measurements taken up to 7 days prior to delivery (2007 to 2014). Sonographic estimated fetal weight was calculated using 20 previously published formulas. Macrosomia prediction was evaluated for every formula utilizing: (1) measures of accuracy (sensitivity, specificity and so on); (2) comparison of the systematic and random errors (SE and RE), and the proportion of estimates within 10% of actual birth weight for macrosomic and non-macrosomic neonates. Performance measurements were evaluated for different macrosomia thresholds: 4000, 4250 and 4500 g. Best performing formula for every threshold was defined as the one with the lowest Euclidean distance (=SQRT(SE2+RE2)). RESULTS: Out of 7977 women who met the inclusion criteria, 754 (9.4%) delivered a neonate weighing ⩾4000 g, 266 (3.3%) delivered a neonate weighing⩾4250 g and 75 (0.9%) delivered a neonate weighing⩾4500 g. Considerable variability was noted between the accuracy parameters of the different formulas, with Woo's formula integrating Abdominal circumference (AC) and femur length (FL) as the most sensitive formula with the highest negative predictive value for all thresholds and Woo's formula using AC, FL and biparietal diameter (BPD) as the most specific for all thresholds. The same formula also demonstrated the best overall accuracy. Regardless of threshold chosen, 80% or more of formulas demonstrated negative systematic error, meaning lower EFW than actual birthweight. As for the Euclidean distance, Hadlock's formula (AC, FL and BPD) ranked the highest for the 4000 and 4250 g thresholds, whereas Shepard's formula (AC and BPD) ranked the highest for the 4500 g threshold. CONCLUSION: Considerable variability exist between formulas for prediction of neonatal macrosomia. Formulas by Hadlock's and Shepard's utilizing AC, BPD±FL were most accurate for macrosomia prediction at 4000, 4250 and 4500 g thresholds, respectively.


Assuntos
Macrossomia Fetal/diagnóstico por imagem , Peso Fetal , Ultrassonografia Pré-Natal/métodos , Abdome/diagnóstico por imagem , Abdome/embriologia , Adulto , Peso ao Nascer , Feminino , Fêmur/diagnóstico por imagem , Fêmur/embriologia , Macrossomia Fetal/classificação , Idade Gestacional , Humanos , Recém-Nascido , Masculino , Osso Parietal/diagnóstico por imagem , Osso Parietal/embriologia , Valor Preditivo dos Testes , Gravidez , Estudos Retrospectivos
5.
J Perinatol ; 37(5): 513-517, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28151496

RESUMO

OBJECTIVE: As sonographic estimation of fetal weight (EFW) carries substantial impact, especially in large-for-gestational-age (LGA) neonates, we aimed to compare the accuracy of various formulas for prediction of LGA neonates. STUDY DESIGN: Retrospective cohort study of singleton gestations at term, with EFW up to 7 days before delivery (2007 to 2014). Small-for-gestational-age neonates were excluded. LGA prediction for various formulas was evaluated by: (i) measures of performance (sensitivity, specificity, etc.); (ii) systematic and random errors (SE and RE) and the proportion of estimates (POEs) exceeding 10% of actual birth weight. Best performing formula was defined as the one with the lowest Euclidean distance [=square root of (SE2+RE2)]. RESULTS: Out of 62 102 deliveries, 7996 met inclusion criteria, of which 1618 neonates were LGA (22%). There was a considerable variation in sensitivity (74.6±16.3%, 23.5% to 99%), specificity (86.3±10.6%, 51.7% to 99.6%), positive predictive value (64.9±12.4%, 35.6% to 93.8%), positive likelihood ratio (LR; 9.3±10.9, 2.1 to 54.2) and negative LR (0.3±0.16, 0.02 to 0.8), a mild variation in the negative predictive value (92.9±3.7%, 82.3% to 99.5%) and a minimal variation in the area under the curve (94.3%, 93.0 to 95.1; mean±s.d., range for all). Absolute SE was higher for the LGA group in 11/20 formulas (55%). The RE and POE were lower in 19/20 (95%) and 14/20 (70%) for the LGA neonates, respectively. CONCLUSION: There is a wide variation in EFW formulas performance for detecting LGA. Hadlock's formula (1985) combining abdominal circumference, femur length and biparietal diameter ranked highest.


Assuntos
Peso ao Nascer , Peso Fetal , Feto/diagnóstico por imagem , Idade Gestacional , Ultrassonografia Pré-Natal/normas , Adulto , Feminino , Humanos , Recém-Nascido , Recém-Nascido Pequeno para a Idade Gestacional , Israel , Masculino , Gravidez , Estudos Retrospectivos , Sensibilidade e Especificidade , Centros de Atenção Terciária , Ultrassonografia Pré-Natal/métodos
6.
Ultrasound Obstet Gynecol ; 47(2): 217-23, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25728404

RESUMO

OBJECTIVE: To determine the association between sonographic assessment of fetal biparietal diameter (BPD) and pregnancy outcome. METHODS: This was a retrospective cohort study of pregnancies at 37-42 weeks of gestation which had antepartum sonographic measurement of BPD within 7 days before delivery. Eligibility was limited to singleton pregnancies with neither known structural or chromosomal abnormalities nor prelabor Cesarean delivery (CD). The association of BPD with outcome was analyzed using multivariate logistic regression, receiver-operating characteristics curves and stratification according to BPD quartiles. RESULTS: In total, 3229 women were eligible for analysis, of whom 2483 (76.9%) had a spontaneous vaginal delivery (SVD), 418 (12.9%) underwent operative vaginal delivery (OVD) and 328 (10.2%) underwent CD. The mean BPD in the obstetric intervention groups (OVD and CD) was significantly higher than that in the SVD group (P < 0.001). After adjusting for confounders, increased BPD was an independent risk factor such that higher values of BPD were associated with progressively higher risk of obstetric intervention (adjusted odds ratio, 1.05 for each 1-mm increase in BPD (95% CI, 1.02-1.09)), but no clear cut-off value for obstetric intervention was found. The fourth quartile group (BPD ≥ 97 mm) was associated with a significantly lower SVD rate (P < 0.001) and higher OVD rate (P = 0.04), relative to the first (BPD 88-90 mm) and second (BPD 91-93 mm) quartile groups, with no apparent adverse impact on immediate neonatal outcome. CONCLUSIONS: Increased BPD within the week prior to delivery is an independent risk factor such that higher values of BPD are associated with progressively higher risk of obstetric intervention; however, in our experience, no adverse neonatal outcome resulted from such intervention. Thus, increased BPD should not discourage a trial of vaginal delivery.


Assuntos
Parto Obstétrico/estatística & dados numéricos , Desenvolvimento Fetal , Lobo Parietal/diagnóstico por imagem , Resultado da Gravidez , Ultrassonografia Pré-Natal/métodos , Adulto , Parto Obstétrico/métodos , Feminino , Humanos , Modelos Logísticos , Análise Multivariada , Complicações do Trabalho de Parto/etiologia , Tamanho do Órgão , Lobo Parietal/embriologia , Lobo Parietal/crescimento & desenvolvimento , Valor Preditivo dos Testes , Gravidez , Curva ROC , Estudos Retrospectivos , Fatores de Risco
7.
Ultrasound Obstet Gynecol ; 48(4): 470-475, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26663574

RESUMO

OBJECTIVE: The antenatal diagnosis of twin anemia-polycythemia sequence (TAPS) in monochorionic-diamniotic (MCDA) twin pregnancies is based on elevated peak systolic velocity in the middle cerebral artery (MCA-PSV) in the donor twin and decreased MCA-PSV in the recipient twin. However, the association between these parameters and polycythemia has not yet been established. The aim of this study was to determine whether MCA-PSV can predict polycythemia in MCDA pregnancies. METHODS: This was a prospective cohort study of MCDA pregnancies recruited at 14-18 weeks' gestation from a single tertiary care center between January 2011 and June 2014. Fetal MCA Doppler waveforms were recorded every 2 weeks from 18 weeks' gestation until delivery. Only those with an MCA-PSV measurement within 1 week of delivery were included in the analysis. Neonatal hematocrit level was determined in all twins from venous blood obtained within 4 h of delivery. Polycythemia was defined as a hematocrit of > 65%, and anemia as a hematocrit of < 45%. TAPS was diagnosed when an intertwin hemoglobin difference of > 8 g/dL and reticulocyte count ratio of > 1.7 were observed. RESULTS: Of 162 MCDA pregnancies followed during the study period, 69 had an MCA-PSV measurement within 1 week of delivery and were included in the study. Twenty-five neonates were diagnosed with polycythemia and nine twin pairs met the criteria for TAPS. In a pooled analysis, MCA-PSV was negatively correlated with neonatal hematocrit (P = 0.017, r = -0.215) and was significantly higher in anemic fetuses than in normal controls (1.15 multiples of the median (MoM) vs 1.02 MoM, respectively; P = 0.001). However, MCA-PSV was similar among polycythemic and normal fetuses (0.95 MoM vs 1.02 MoM, respectively; P = 0.47). Intertwin difference in MCA-PSV (delta MCA-PSV) was positively correlated with intertwin hematocrit difference (P = 0.002, r = 0.394). Moreover, twin pregnancies with an intertwin hematocrit difference of > 24% had a significantly greater delta MCA-PSV than did those with an intertwin hematocrit difference of ≤ 24% (delta MCA-PSV, 19 vs 5 cm/s; P < 0.001). CONCLUSIONS: MCA-PSV is not significantly decreased in polycythemic MCDA twins. However, delta MCA-PSV is associated with a large intertwin difference in hematocrit, and its use may be better than conventional methods for the risk assessment of TAPS. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Artéria Cerebral Média/diagnóstico por imagem , Artéria Cerebral Média/fisiopatologia , Policitemia/fisiopatologia , Ultrassonografia Pré-Natal/métodos , Adulto , Velocidade do Fluxo Sanguíneo , Feminino , Idade Gestacional , Humanos , Idade Materna , Policitemia/diagnóstico por imagem , Gravidez , Gravidez de Gêmeos , Estudos Prospectivos , Gêmeos Monozigóticos , Adulto Jovem
8.
Ultrasound Obstet Gynecol ; 46(6): 670-7, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25867754

RESUMO

OBJECTIVES: To compare the outcomes of radiofrequency ablation (RFA) and bipolar cord coagulation (BPC) methods for selective feticide in complicated monochorionic (MC) twin gestations and to determine risk factors for adverse pregnancy outcome. METHODS: This was a retrospective cohort study of all patients with complicated MC twin pregnancy who underwent selective reduction in a single tertiary care center between 2000 and 2014. We compared the two methods with respect to various demographic, obstetric and perinatal outcome variables. RESULTS: Fifty-three selective terminations in complicated MC twin gestations were performed, 36 by RFA and 17 by BPC. Each technique resulted in a similar overall survival rate of the remaining twin (88.9% vs 76.5%, P = 0.25). Likewise, the mean procedure-to-delivery interval, the rate of spontaneous preterm delivery < 37, < 34, < 32 and < 28 weeks and the rate of preterm prelabor rupture of the membranes did not differ between the groups. However, among patients in the BPC group, there was a trend towards earlier gestational age at delivery (31.3 vs 35.0 weeks, P = 0.09) compared with in the RFA group. There was selective reduction by RFA due to selective intrauterine growth restriction (sIUGR) in 19 cases, 17 (89.5%) of which survived perinatally, with delivery at a median gestational age of 37 weeks. There were no significant differences in perinatal outcome, irrespective of whether the procedure was performed pre- or post-viability. All post-viability reductions, most of which were by RFA, resulted in perinatal survival. CONCLUSIONS: Perinatal outcome of complicated MC twin gestations undergoing selective feticide seems to be similar regardless of whether termination is by BPC or RFA. Nevertheless, RFA appears to be particularly useful in MC twins complicated by sIUGR and in cases requiring selective reduction beyond the age of viability.


Assuntos
Ablação por Cateter/métodos , Eletrocoagulação/métodos , Redução de Gravidez Multifetal/métodos , Gravidez de Gêmeos , Cordão Umbilical/cirurgia , Adulto , Parto Obstétrico/métodos , Feminino , Retardo do Crescimento Fetal/etiologia , Retardo do Crescimento Fetal/cirurgia , Fetoscopia/métodos , Idade Gestacional , Humanos , Gravidez , Complicações na Gravidez/etiologia , Complicações na Gravidez/cirurgia , Resultado da Gravidez , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA