Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
J Thorac Dis ; 11(3): 708-716, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31019758

RESUMO

BACKGROUND: Transcatheter closure for atrial septal defect (ASD) with inferior-posterior rim deficiency has been scarcely reported with proper identification of the indications and limits. We aimed to assess the safety and feasibility of transcatheter closure of ASDs with deficient rims, paying particular attention to cases with inferior-posterior rim deficiency. METHODS: From January 2008 to January 2013, 241 patients underwent transcatheter ASD closure, including 50 cases (20.7%) with deficient rims, other than the anterior-superior one. Eighteen patients (12 females) presented inferior-posterior rim deficiency. Their median age was 8 (1.4-85) years and their median weight was 24 [9-97] kg. Transcatheter closure was performed in all cases under transesophageal echocardiography (TEE) guidance in children and intracardiac echocardiography (ICE) guidance in adults. RESULTS: Out of 18 patients with inferior-posterior rim deficiency, only 8 underwent successful immediate transcatheter closure. Four cases failed to be closed. Major complications occurred in 6 patients, including 4 device embolizations, 1 pericardial effusion and 1 complete atrioventricular block that resolved after surgical removal of the device. During a median follow up of 54±13 months, a residual right-to-left shunt was documented in 2 more cases, requiring surgery in one case because of cyanosis. Transcatheter closure was successfully performed in the rest of the 223 patients, including in the 32 cases with deficient rims other than inferior-posterior. CONCLUSIONS: Transcatheter closure of ASDs with inferior-posterior rim deficiency cannot be recommended.

2.
J Thorac Dis ; 10(3): E207-E209, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29707375

RESUMO

Trans-catheter device closure of patent ductus arteriosus (PDA) via femoral route is the commonly used, safe and effective procedure. Trans-jugular approach has been successfully used in older children with interrupted inferior vena cava. We report a case of successful occlusion of PDA using Amplatzer duct occluder (ADO) via trans-jugular approach following difficulties encountered in gaining femoral venous access. A 6-month-old male infant, weighing 8 kg was admitted for percutaneous catheter closure of PDA. Echocardiogram showed a 4.5 mm duct and left heart dilatation. Femoral venous access was not possible; therefore, we decided to use a trans-jugular approach. The duct was occluded using 8/6 mm ADO. Successful closure of the duct was confirmed with an aortogram. Post procedure echocardiogram showed no residual shunt across the duct. We highlight that trans-catheter closure of PDA using jugular venous access is safe and effective even in infants.

3.
EuroIntervention ; 10(11): 1326-31, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25631368

RESUMO

AIMS: The VALEO vascular stent is a stainless steel, pre-mounted, open-cell stent. Redilation to large diameters and low profile are advantages in growing children. Clinical experience is scarce. This study aimed to analyse our experience with the use of the VALEO vascular stent in children. METHODS AND RESULTS: Between June 2010 and December 2012, 41 VALEO stents were inserted during 30 transcatheter (group 1) and three perioperative procedures (group 2). Data were retrospectively analysed. Median age at implantation was 3.8 years (four days - 23 years), and median weight was 13.3 kg (2.2-53 kg). Indications were: pulmonary artery (n=23), pulmonary vein (n=1) or subhepatic vein (n=1) stenosis, and ductus arteriosus stenting (n=8). Stent placement was achieved in all but one. Acute complications (n=11) included stent dislodgement in two patients and fracture in three patients, with vessel predilatation as a risk factor. Median "stent" follow-up reached 7.83 months (0.4-34.3 months) and included 26 recatheterisations (23 patients, median interval 6.2 months, range 0.2-33 months). Ten stents were redilated. Surgery in six patients (interval 1.9 to 10 months) showed patent endothelialised stents. No "late" type II or III stent fractures were seen. CONCLUSIONS: The VALEO stent is useful in children. Low radial force is counterbalanced by high flexibility, allowing implantation in distal and tortuous lesions. Early fractures occur. Longer-term follow-up is needed.


Assuntos
Canal Arterial/cirurgia , Cardiopatias Congênitas/cirurgia , Complicações Pós-Operatórias , Artéria Pulmonar/cirurgia , Stents , Adolescente , Criança , Pré-Escolar , Estudos de Coortes , Constrição Patológica/cirurgia , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/métodos , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Desenho de Prótese , Falha de Prótese , Estudos Retrospectivos , Aço Inoxidável , Resultado do Tratamento , Adulto Jovem
4.
Arch Cardiovasc Dis ; 107(11): 607-14, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25453718

RESUMO

BACKGROUND: Percutaneous implantation of pulmonary valves has recently been introduced into clinical practice. AIM: To analyse data of patients treated in France between April 2008 and December 2010. METHODS: Prospective, observational, multi-centric survey by means of a database registry of the Filiale de cardiologie pédiatrique et congénitale. RESULTS: Sixty-four patients were included, with a median (range) age of 21.4 (10.5-77.3) years. The majority (60.9%) of the patients were New York Heart Association (NYHA) class II. The most common congenital heart disease was tetralogy of Fallot with or without pulmonary atresia (50%). Indication for valve implantation was stenosis in 21.9%, regurgitation in 10.9% and association of stenosis and regurgitation in 67.2%. Implantation was successful in all patients. Pre-stenting was performed in 96.9% of cases. Median (range) procedure time was 92.5 (25-250) minutes. No significant regurgitation was recorded after the procedure, and the trans-pulmonary gradient was significantly reduced. Early minor complications occurred in five cases (7.8%). Three patients died during a median follow-up of 4.6 (0.2-5.2) years, two from infectious endocarditis and one from end-stage cardiac failure. Surgical reintervention was required in three patients. Follow-up with magnetic resonance imaging demonstrated significant improvements in right ventricular volumes and pulmonary regurgitation in mixed and regurgitant lesions. CONCLUSIONS: Transcatheter pulmonary valve implantation is highly feasible and mid-term follow-up demonstrates sustained improvement of right ventricular function. Late endocarditis is of concern, therefore longer follow-up in more patients is urgently needed to better assess long-term outcome. CLINICAL TRIAL REGISTRATION: NCT01250327.


Assuntos
Cateterismo Cardíaco/instrumentação , Cardiopatias Congênitas/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar/terapia , Estenose da Valva Pulmonar/terapia , Valva Pulmonar/cirurgia , Adolescente , Adulto , Idoso , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/mortalidade , Criança , Feminino , França , Pesquisas sobre Atenção à Saúde , Cardiopatias Congênitas/mortalidade , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/diagnóstico , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/mortalidade , Insuficiência da Valva Pulmonar/fisiopatologia , Estenose da Valva Pulmonar/diagnóstico , Estenose da Valva Pulmonar/etiologia , Estenose da Valva Pulmonar/mortalidade , Estenose da Valva Pulmonar/fisiopatologia , Recuperação de Função Fisiológica , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Direita , Adulto Jovem
5.
Arch Cardiovasc Dis ; 107(12): 646-53, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25241222

RESUMO

BACKGROUND: Studies on intracardiac echocardiography for transcatheter closure of secundum atrial septal defect (ASD) only include ASDs ≤38mm diameter without rim deficiency. AIMS: To assess transcatheter closure of complex ASDs under intracardiac echocardiography guidance. METHODS: Retrospective study from January 2006 to January 2012 in all consecutive adult patients referred to our centre for percutaneous device closure of ASD. Complex cases were defined as defect>38mm and/or defect with rim deficiency other than the anterior-superior rim. RESULTS: Transcatheter closure was performed in 93 consecutive adult patients (59 women) with a median age of 48 (18-88) years. Complex cases comprised 17 patients (18%) with a median age of 54 (20-81) years and a median weight of 58 (45-99) kg. Thirteen cases had one or more deficient rims other than the anterior-superior rim, whereas nine had an ASD size>38mm. Transcatheter closure was successful in 14 cases, whereas three cases failed (18%). Minor complications occurred in three patients (18%). All the other non-complex ASDs were successfully closed percutaneously. Among the 93 patients, rim deficiency other than the anterior-superior rim tended to be associated with failure of transcatheter closure (P=0.058). CONCLUSION: Transcatheter closure of complex ASDs is safe and effective under intracardiac echocardiographic guidance.


Assuntos
Cateterismo Cardíaco , Comunicação Interatrial/terapia , Ultrassonografia de Intervenção , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Ecocardiografia Transesofagiana , Feminino , Comunicação Interatrial/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Dispositivo para Oclusão Septal , Resultado do Tratamento , Ultrassonografia de Intervenção/efeitos adversos , Adulto Jovem
6.
Ann Thorac Surg ; 98(2): e41-3, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25087830

RESUMO

Anomalous origin of the left coronary artery from the pulmonary artery is a rare congenital anomaly that usually presents in infancy with cardiomyopathy and congestive heart failure. Surgical reimplantation of the anomalous left coronary artery is offered as definitive treatment in infancy. We describe the case of a 26-year-old man presenting with cardiomyopathy who was identified to have an anomalous left coronary artery from the pulmonary artery. Surgical reimplantation presented a high risk due to severe postcapillary pulmonary hypertension. Transcatheter occlusion of the proximal left main coronary artery was obtained. The patient was started subsequently on anticongestive therapy. Surgical coronary artery bypass was performed 3-months later after resolution of postcapillary pulmonary hypertension. The patient remains well at 1-year follow-up.


Assuntos
Anormalidades Múltiplas/cirurgia , Anomalias dos Vasos Coronários/complicações , Anomalias dos Vasos Coronários/cirurgia , Hipertensão Pulmonar/etiologia , Isquemia Miocárdica/etiologia , Artéria Pulmonar/anormalidades , Artéria Pulmonar/cirurgia , Adulto , Humanos , Masculino
7.
Catheter Cardiovasc Interv ; 83(7): E260-8, 2014 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-24619978

RESUMO

OBJECTIVES: Evaluate the incidence, diagnosis, and outcome of coronary compression (CC) during right-ventricular outflow tract interventions. BACKGROUND: The incidence, risk factors, diagnosis, and outcomes of CC during percutaneous pulmonary valve implantation are poorly defined. METHODS: One-hundred consecutive patients (May 2008 to January 2012) undergoing transcatheter right-ventricular outflow tract treatment in two institutions were studied. RESULTS: CC occurred in six patients (6%) with a right ventricular outflow conduit stenosis, at a median age of 24.5 (13-49) years. It involved the left main coronary artery in four and the right coronary artery originating from the left anterior descending coronary artery in two patients. Conduit types were homograft (n = 3), bioprosthesis (n = 2), and a pericardial patch (n = 1). Median diameter was 23 (17-24) mm at surgical implantation. CC was diagnosed through a selective coronary angiogram during balloon dilation of the conduit in the first three patients and through an aortic root angiogram for the three next cases because we recognized that proximal compression could be masked during coronary artery cannulation. It was suspected on pre-procedure imaging (magnetic resonance imaging and/or computed tomography) in three cases. Patients with abnormal coronary anatomy tend to be at increased risk of CC (P = 0.0504). One institution had a higher incidence of CC (P = 0.04). CC resolved after balloon deflation. No patient underwent conduit stenting. Four patients underwent surgical reconstruction of right ventricular outflow tract. CONCLUSIONS: CC is accurately diagnosed during right-ventricular outflow tract interventions. We recommend an aortic root angiogram during dilation with a non-compliant balloon matching the diameter and length of the intended conduit implant.


Assuntos
Oclusão Coronária/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Insuficiência da Valva Pulmonar/cirurgia , Obstrução do Fluxo Ventricular Externo/cirurgia , Adolescente , Adulto , Cateterismo Cardíaco , Angiografia Coronária , Oclusão Coronária/diagnóstico , Oclusão Coronária/epidemiologia , Feminino , Seguimentos , França/epidemiologia , Humanos , Incidência , Análise de Intenção de Tratamento , Masculino , Pessoa de Meia-Idade , Valva Pulmonar , Estudos Retrospectivos , Resultado do Tratamento , Obstrução do Fluxo Ventricular Externo/diagnóstico , Obstrução do Fluxo Ventricular Externo/epidemiologia , Adulto Jovem
8.
Cardiol Young ; 24(4): 729-31, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23902997

RESUMO

We report a case of successful recanalisation of the left pulmonary artery after occlusion due to embolic thrombi in a 9-month-old infant after surgical repair of a common atrioventricular canal with tetralogy of Fallot. A transhepatic approach was used because of caval vein thrombosis. After the failure of high-pressure balloon angioplasty, the left pulmonary artery was successfully recanalised with cutting balloons, followed by stent implantation with an excellent result.


Assuntos
Comunicação Atrioventricular/cirurgia , Complicações Pós-Operatórias/cirurgia , Artéria Pulmonar/cirurgia , Embolia Pulmonar/cirurgia , Tetralogia de Fallot/cirurgia , Angiografia , Cateterismo de Swan-Ganz/métodos , Defeitos dos Septos Cardíacos , Humanos , Lactente , Masculino , Complicações Pós-Operatórias/diagnóstico por imagem , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem
10.
Catheter Cardiovasc Interv ; 82(4): 556-9, 2013 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-22511530

RESUMO

Aortic coarctation is an unusual cause of hypertension during pregnancy and its management is not clarified. We report transcatheter balloon dilatation and stenting for native aortic coarctation in a 22-year-old pregnant woman with severe and uncontrolled systemic hypertension. Arterial blood pressure could be successfully controlled with medical treatment during the rest of the pregnancy and the patient underwent uneventful delivery. No adverse events or recoarctation was observed during 24 months clinical follow-up. In conclusion, native aortic coarctation can be successfully treated during pregnancy with transcatheter therapy. More experience is needed to confirm the safety and efficacy of such management.


Assuntos
Angioplastia com Balão , Coartação Aórtica/terapia , Pressão Arterial , Cateterismo Cardíaco , Hipertensão Induzida pela Gravidez/terapia , Angioplastia com Balão/instrumentação , Anti-Hipertensivos/uso terapêutico , Coartação Aórtica/complicações , Coartação Aórtica/diagnóstico , Coartação Aórtica/fisiopatologia , Aortografia , Pressão Arterial/efeitos dos fármacos , Feminino , Humanos , Hipertensão Induzida pela Gravidez/diagnóstico , Hipertensão Induzida pela Gravidez/etiologia , Hipertensão Induzida pela Gravidez/fisiopatologia , Nascido Vivo , Imageamento por Ressonância Magnética , Gravidez , Índice de Gravidade de Doença , Stents , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...