PLoS One ; 18(4): e0284719, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37079589

RESUMO

BACKGROUND: Tinnitus is a common problem in patients with a cochlear implant (CI). Between 4% and 25% of CI recipients experience a moderate to severe tinnitus handicap. However, apart from handicap scores, little is known about the real-life impact tinnitus has on those with CIs. We aimed to explore the impact of tinnitus on adult CI recipients, situations impacting tinnitus, tinnitus-related difficulties and their management strategies, using an exploratory sequential mixed-method approach. METHODS: A 2-week web-based forum was conducted using Cochlear Ltd.'s online platform, Cochlear Conversation. A thematic analysis was conducted on the data from the forum discussion to develop key themes and sub-themes. To quantify themes and sub-themes identified, a survey was developed in English with face validity using cognitive interviews, then translated into French, German and Dutch and disseminated on the Cochlear Conversation platform, in six countries (Australia, France, Germany, New Zealand, the Netherlands and United Kingdom). Participants were adult CI recipients experiencing tinnitus who received a Cochlear Ltd. CI after 18 years of age. RESULTS: Four key themes were identified using thematic analysis of the discussion forum: tinnitus experience, situations impacting tinnitus, difficulties associated with tinnitus and tinnitus management. Among the 414 participants of the survey, tinnitus burden on average was a moderate problem without their sound processor and not a problem with the sound processor on. Fatigue, stress, concentration, group conversation and hearing difficulties were the most frequently reported difficulties and was reported to intensify when not wearing the sound processor. For most CI recipients, tinnitus seemed to increase when performing a hearing test, during a CI programming session, or when tired, stressed, or sick. To manage their tinnitus, participants reported turning on their sound processor and avoiding noisy environments. CONCLUSION: The qualitative analysis showed that tinnitus can affect everyday life of CI recipients in various ways and highlighted the heterogeneity in their tinnitus experiences. The survey findings extended this to show that tinnitus impact, related difficulties, and management strategies often depend on sound processor use. This exploratory sequential mixed-method study provided a better understanding of the potential benefits of sound processor use, and thus of intracochlear electrical stimulation, on the impact of tinnitus.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva , Percepção da Fala , Zumbido , Adulto , Humanos , Percepção da Fala/fisiologia , Implante Coclear/métodos , Perda Auditiva/complicações , Perda Auditiva/cirurgia
2.
J Clin Med ; 11(19)2022 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-36233532

RESUMO

Patients with single-sided deafness can experience an ipsilateral disabling tinnitus that has a major impact on individuals' social communication and quality of life. Cochlear implants appear to be superior to conventional treatments to alleviate tinnitus in single-sided deafness. We conducted a systematic review to evaluate the effectiveness of cochlear implants in single-sided deafness with disabling tinnitus when conventional treatments fail to alleviate tinnitus (PROSPERO ID: CRD42022353292). All published studies in PubMed/MEDLINE and SCOPUS databases until December 2021 were included. A total of 474 records were retrieved, 31 studies were included and were divided into two categories according to whether tinnitus was assessed as a primary complaint or not. In all studies, cochlear implantation, evaluated using subjective validated tools, succeeded in reducing tinnitus significantly. Objective evaluation tools were less likely to be used but showed similar results. A short-(3 months) and long-(up to 72 months) term tinnitus suppression was reported. When the cochlear implant is disactivated, complete residual tinnitus inhibition was reported to persist up to 24 h. The results followed a similar pattern in studies where tinnitus was assesed as a primary complaint or not. In conclusion, the present review confirmed the effectiveness of cochlear implantation in sustainably reducing disabling tinnitus in single-sided deafness patients.

3.
Trends Hear ; 26: 23312165221128431, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36154765

RESUMO

The aim of this study was to estimate the prevalence and distress of tinnitus pre- and post-cochlear implantation in patients with bilateral severe to profound hearing loss. In this retrospective study, we included patients from a cochlear implant clinic in Perth, Western Australia. Pre- and post-cochlear implantation data from 300 implant recipients were collected on self-reported presence of tinnitus, tinnitus distress using the Tinnitus Reaction Questionnaire (TRQ), hearing-related quality of life using the Abbreviated Profile of Hearing Aid Benefit (APHAB), and consonant-nucleus vowel-consonant (CNC) word recognition test scores. Retrospectively, patients were grouped into those with or without tinnitus, and the grade of tinnitus distress. The potential factors associated with post-implantation changes in the presence of tinnitus and its distress were evaluated. Tinnitus prevalence was 55.8% pre-operatively and 44.3% post-implantation with a median TRQ score respectively of 12.0 (IQR: 1.0-28.0) and 3.5 (IQR: 0.0-16.2) points. Among the 96 patients experiencing tinnitus pre-implantation, 14.6% patients experienced moderate to catastrophic tinnitus distress pre-implantation compared to 6.3% post-implantation. To conclude, the pre- and post-implantation median TRQ score for the cohort population showed that tinnitus was a "slight" handicap. Tinnitus prevalence and its associated tinnitus distress decreased post-implantation. Patients with tinnitus post-implantation were significantly younger and had less severe pre-implantation hearing loss in the non-implanted ear than patients without tinnitus. Further research is needed to understand the factors influencing changes in tinnitus.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva , Percepção da Fala , Zumbido , Implante Coclear/efeitos adversos , Perda Auditiva/cirurgia , Humanos , Prevalência , Qualidade de Vida , Estudos Retrospectivos , Zumbido/complicações , Zumbido/diagnóstico , Zumbido/epidemiologia , Resultado do Tratamento
4.
Sci Rep ; 12(1): 14423, 2022 08 24.
Artigo em Inglês | MEDLINE | ID: mdl-36002556

RESUMO

Tinnitus is a common symptom in cochlear implant (CI) recipients. There is no clear evidence of the influence of tinnitus on hearing-related quality of life (QoL) in this population. The aim of this study was to assess the relationship between hearing-related QoL measured by the Speech, Spatial and Qualities of Hearing scale (SSQ12) and tinnitus annoyance or perceived change in tinnitus annoyance after cochlear implantation. The study sample consisted of 2322 implanted adults across France, Germany, Ireland, Italy, the Netherlands, Sweden and the United Kingdom. Information relating to QoL measured using the SSQ12 and tinnitus annoyance and change in tinnitus annoyance, assessed using single-item questions, were collected one or more years post-implantation. The relationship between SSQ12 score and tinnitus annoyance or change in tinnitus annoyance was analysed using linear models adjusted for age and unilateral versus bilateral implants. Tukey pairwise tests were used to compare mean SSQ12 scores across levels of tinnitus annoyance and changes. Tinnitus prevalence was 33.9% post-implantation. Recipients with tinnitus had a significantly lower SSQ12 score than recipients without tinnitus. SSQ scores varied significantly with tinnitus annoyance, age and unilateral versus bilateral implants. Overall, CI recipients who experienced less bothersome tinnitus reported better hearing-related QoL. Healthcare professionals should be aware of the influence of tinnitus on CI recipients' hearing to manage patient expectations.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Zumbido , Adulto , Audição , Humanos , Qualidade de Vida , Inquéritos e Questionários , Zumbido/etiologia , Zumbido/cirurgia , Resultado do Tratamento
5.
BMJ Open ; 12(6): e063432, 2022 06 17.
Artigo em Inglês | MEDLINE | ID: mdl-35715189

RESUMO

INTRODUCTION: Tinnitus is the perception of sound without an external stimulus, often experienced as a ringing, buzzing sound. While several studies have shown a reduction in tinnitus distress following cochlear implantation, others showed an increase or no change after implantation. At this stage, clinicians have little certainty when counselling their patients prior to implantation regarding tinnitus post-implantation. To help clinicians to counsel cochlear implant (CI) candidates on the risk of developing or improving tinnitus after implantation, we aim to assess the effect of electrical stimulation with a CI on tinnitus impact for individual adult patients with tinnitus. We will also apply prediction models to individual patient data (IPD) of clinical trials to find predictive factors of the effect of electrical stimulation on tinnitus impact. METHOD AND ANALYSIS: The IPD meta-analysis is a follow-up project of the systematic review on cochlear implantation in patients with tinnitus as a primary complaint. First, the systematic searches will be updated to date. Methodological quality of eligible studies will be assessed using the Risk of Bias In Non-randomised Studies of Intervention tool (ROBINS-I). Based on a data-sharing agreement, authors of the eligible studies will be invited to share their deidentified and complete IPD. The primary outcome is the effect of electrical stimulation with a CI on tinnitus impact 1 month or more post-implantation. IPD meta-analysis will be used to assess the primary outcome, while differentiating the tinnitus impact questionnaires. Second, linear regression analyses will be used to model the effect of electrical stimulation on tinnitus impact based on relevant predictors. ETHICS AND DISSEMINATION: The Medical Research Involving Human Subject Act does not apply, and ethical approval is not required. The study results will be made accessible to the public in a peer-review open access journal. PROSPERO REGISTRATION NUMBER: CRD42022319367, review ongoing.


Assuntos
Implante Coclear , Implantes Cocleares , Zumbido , Adulto , Humanos , Estimulação Elétrica , Fatores de Risco , Inquéritos e Questionários , Zumbido/prevenção & controle , Zumbido/terapia , Metanálise como Assunto , Revisões Sistemáticas como Assunto
6.
Brain Sci ; 11(11)2021 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-34827395

RESUMO

Several electrical stimulation patterns of the auditory nerve have been described for tinnitus relief, but there is no consensus on the most effective stimulation pattern. Therefore, we aim to systematically review the literature on the effect of intra- and extracochlear electrical stimulation patterns as a treatment option for patients with tinnitus. Only studies on intra- and extracochlear electrical stimulation for patients with tinnitus were included if the stimulation used did not concern standardized CI stimulation patterns to primarily rehabilitate hearing loss as intervention. A total of 34 studies met the inclusion criteria, with 10 studies (89 patients) on intracochlear electrical stimulation and 25 studies on extracochlear electrical stimulation (1109 patients). There was a high to medium risk of bias in 22 studies, especially due to lack of a non-exposed group and poor selection of the exposed group. All included studies showed subjective tinnitus improvement during or after electrical stimulation, using different stimulation patterns. Due to methodological limitations and low reporting quality of the included studies, the potential of intra- and extracochlear stimulation has not been fully explored. To draw conclusions on which stimulation patterns should be optimized for tinnitus relief, a deeper understanding of the mechanisms involved in tinnitus suppression is needed.

8.
Front Aging Neurosci ; 13: 647285, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34177549

RESUMO

Tinnitus can be a burdensome condition on both individual and societal levels. Many aspects of this condition remain elusive, including its underlying mechanisms, ultimately hindering the development of a cure. Interdisciplinary approaches are required to overcome long-established research challenges. This review summarizes current knowledge in various tinnitus-relevant research fields including tinnitus generating mechanisms, heterogeneity, epidemiology, assessment, and treatment development, in an effort to highlight the main challenges and provide suggestions for future research to overcome them. Four common themes across different areas were identified as future research direction: (1) Further establishment of multicenter and multidisciplinary collaborations; (2) Systematic reviews and syntheses of existing knowledge; (3) Standardization of research methods including tinnitus assessment, data acquisition, and data analysis protocols; (4) The design of studies with large sample sizes and the creation of large tinnitus-specific databases that would allow in-depth exploration of tinnitus heterogeneity.

9.
BMJ Open ; 11(5): e043288, 2021 05 18.
Artigo em Inglês | MEDLINE | ID: mdl-34006544

RESUMO

INTRODUCTION: Tinnitus is the perception of sound without an external stimulus, often experienced as a ringing or buzzing sound. Subjective tinnitus is assumed to origin from changes in neural activity caused by reduced or lack of auditory input, for instance due to hearing loss. Since auditory deprivation is thought to be one of the causes of tinnitus, increasing the auditory input by cochlear implantation might be a possible treatment. In studies assessing cochlear implantation for patients with hearing loss, tinnitus relief was seen as a secondary outcome. Therefore, we will assess the effect of cochlear implantation in patients with primarily tinnitus complaints. METHOD AND ANALYSIS: In this randomised controlled trial starting in January 2021 at the ENT department of the UMC Utrecht (the Netherlands), patients with a primary complaint of tinnitus will be included. Fifty patients (Tinnitus Functional Index (TFI) >32, Beck's Depression Index <19, pure tone average at 0.5, 1, 2 and 4 kHz: bilateral threshold between 50 and ≤75 dB) will be randomised towards cochlear implantation or no intervention. Primary outcome of the study is tinnitus burden as measured by the TFI. Outcomes of interest are tinnitus severity, hearing performances (tinnitus pitch and loudness, speech perception), quality of life, depression and patient-related changes. Outcomes will be evaluated prior to implantation and at 3 and 6 months after the surgery. The control group will receive questionnaires at 3 and 6 months after randomisation. We expect a significant difference between the cochlear implant recipients and the control group for tinnitus burden. ETHICS AND DISSEMINATION: This research protocol was approved by the Institutional Review Board of the University Medical Center (UMC) Utrecht (NL70319.041.19, V5.0, January 2021). The trial results will be made accessible to the public in a peer-review journal. TRIAL REGISTRATION NUMBER: Trial registration number NL8693; Pre-results.


Assuntos
Implante Coclear , Zumbido , Adulto , Perda Auditiva Bilateral , Humanos , Países Baixos , Qualidade de Vida , Ensaios Clínicos Controlados Aleatórios como Assunto , Zumbido/cirurgia , Resultado do Tratamento
10.
Prog Brain Res ; 260: 27-50, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33637223

RESUMO

BACKGROUND: Cochlear implantation (CI) is used in patients with severe-to-profound hearing loss when hearing aids provide limited or no benefit for speech perception. Studies on this topic reported tinnitus reduction as a common side effect of the electrical activation after cochlear implantation. So far, it is unclear what the effect is when patients do receive their implant primarily because of tinnitus complaints. OBJECTIVES: To assess the effectiveness of the electrical stimulation with a cochlear implant in patients with tinnitus as a primary complaint, by systematically reviewing the literature. METHODS: Two independent authors identified studies, extracted data and assessed risk of bias of included studies. Original studies reporting outcomes of electrical stimulation by cochlear implantation for primarily tinnitus (defined as severe or incapacitating distress levels) were included, if they reported a follow-up of at least three months. The pre- and post-implantation tinnitus distress scores on single and/or multi-item questionnaires of the included studies were extracted. RESULTS: In total, 4091 unique articles were retrieved. After screening titles, abstracts and full texts, we included seven prospective cohort studies (105 subjects in total, range: 10-26). All studies had considerable risks of bias. All tinnitus patients in the included studies had asymmetrical hearing loss or single-sided deafness. A statistically significant tinnitus distress improvement based on tinnitus questionnaire scores was found in every study. CONCLUSION: Our systematic review reveals that electrical stimulation by cochlear implants in patients with a primary complaint of tinnitus has a positive impact on tinnitus distress. Nevertheless, only small sample sizes were found and studies showed considerable risks of bias.a.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva Unilateral , Zumbido , Perda Auditiva Unilateral/cirurgia , Humanos , Estudos Prospectivos , Zumbido/cirurgia , Zumbido/terapia , Resultado do Tratamento
11.
Int J Audiol ; 60(5): 374-384, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33074733

RESUMO

OBJECTIVE: Despite the positive effect of a cochlear implant (CI) on tinnitus in many patients, tinnitus remains a problem for a significant proportion of CI users. We investigated the acceptability and effect of sound therapy (a combination of natural background sounds and one concise tinnitus counselling session) on tinnitus and speech perception in CI users who still experienced tinnitus during CI use. DESIGN AND STUDY SAMPLE: Thirty-two CI users (32-78 years) participated in phase 1: a test at the clinic to evaluate six background sounds provided by the sound processor. Eighteen out of the 32 CI users participated in phase 2: an optional take-home evaluation of 2 weeks without sound therapy, followed by 5 weeks with sound therapy, ending with an evaluation visit. RESULTS: Thirty subjects (93.8%) found at least one background sound acceptable. In phase 2, a small improvement with sound therapy was found for tinnitus loudness, annoyance, and intrusiveness. 50% of the subjects subjectively reported benefit of sound therapy. Especially the sense of control on their tinnitus was highly appreciated. No detrimental effect on speech perception was observed. CONCLUSION: The background sounds were acceptable and provided tinnitus relief in some CI users with tinnitus during CI use.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Zumbido , Humanos , Som , Zumbido/diagnóstico , Zumbido/terapia
SELEÇÃO DE REFERÊNCIAS