Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
J Nucl Med Technol ; 50(1): 25-29, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34583952

RESUMO

CE credit: For CE credit, you can access the test for this article, as well as additional JNMT CE tests, online at https://www.snmmilearningcenter.org Complete the test online no later than March 2025. Your online test will be scored immediately. You may make 3 attempts to pass the test and must answer 75% of the questions correctly to receive Continuing Education Hour (CEH) credit. Credit amounts can be found in the SNMMI Learning Center Activity. SNMMI members will have their CEH credit added to their VOICE transcript automatically; nonmembers will be able to print out a CE certificate upon successfully completing the test. The online test is free to SNMMI members; nonmembers must pay $15.00 by credit card when logging onto the website to take the test.123I thyroid scintigraphy can be performed with either a low-energy or a medium-energy (ME) collimator. The high-energy photon emissions from 123I cause septal penetration with scattered photons, which deteriorate image quality. The aim of this study was to evaluate the impact of collimator choice on 123I thyroid scintigraphy in clinical practice. Methods: Forty-seven patients who underwent thyroid planar scintigraphy with both a low-energy, high-resolution (LEHR) collimator and a ME collimator were prospectively recruited using the same imaging protocol. Image quality, collimator sensitivity, and estimation of thyroid size were assessed between LEHR and ME collimators and were compared with thyroid ultrasonography as the gold standard. Results: Images acquired with the ME collimator demonstrated reduced scattered background noise, improved thyroid-to-background contrast, and increased sensitivity in the thyroid gland compared with images acquired by the LEHR collimator. Manual measurement of the thyroid length is more accurate using the ME collimator. Automatic estimation of the thyroid area using the same thyroid threshold is larger in ME collimator images than in LEHR collimator images. Conclusion: Compared with the LEHR collimator, the ME collimator generates cleaner 123I thyroid scintigraphy images with less background noise and has higher collimator sensitivity for thyroid imaging. Different thyroid thresholds should be used to estimate the thyroid area and volume between low and ME collimators.


Assuntos
Radioisótopos do Iodo , Glândula Tireoide , Humanos , Imagens de Fantasmas , Cintilografia , Glândula Tireoide/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único
2.
AJR Am J Roentgenol ; 214(5): 1101-1111, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32130048

RESUMO

OBJECTIVE. The objective of our study was to determine the performance of 3-T multiparametric MRI (mpMRI) for prostate cancer (PCa) detection and localization, stratified by anatomic zone and level, using Prostate Imaging Reporting and Data System version 2 (PI-RADSv2) and whole-mount histopathology (WMHP) as reference. MATERIALS AND METHODS. Multiparametric MRI examinations of 415 consecutive men were compared with thin-section WMHP results. A genitourinary radiologist and pathologist collectively determined concordance. Two radiologists assigned PI-RADSv2 scores and sector location to all detected foci by consensus. Tumor detection rates were calculated for clinical and pathologic (tumor location and zone) variables. Both rigid and adjusted sector-matching models were used to account for fixation-related issues. RESULTS. Of 863 PCa foci in 16,185 prostate sectors, the detection of overall and index PCa lesions in the midgland, base, and apex was 54.9% and 83.1%, 42.1% and 64.0% (p = 0.04, p = 0.02), and 41.9% and 71.4% (p = 0.001, p = 0.006), respectively. Tumor localization sensitivity was highest in the midgland compared with the base and apex using an adjusted match compared with a rigid match (index lesions, 71.3% vs 43.7%; all lesions, 70.8% vs 36.0%) and was greater in the peripheral zone (PZ) than in the transition zone. Three-Tesla mpMRI had similarly high specificity (range, 93.8-98.3%) for overall and index tumor localization when using both rigid and adjusted sector-matching approaches. CONCLUSION. For 3-T mpMRI, the highest sensitivity (83.1%) for detection of index PCa lesions was in the midgland, with 98.3% specificity. Multiparametric MRI performance for sectoral localization of PCa within the prostate was moderate and was best for index lesions in the PZ using an adjusted model.


Assuntos
Imageamento por Ressonância Magnética Multiparamétrica/métodos , Neoplasias da Próstata/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias da Próstata/patologia , Estudos Retrospectivos
3.
Abdom Radiol (NY) ; 45(7): 2225-2234, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31549211

RESUMO

PURPOSE: To investigate the role of qualitative and quantitative DCE-MRI parameters in prostate cancer (PCa) stratified by whole-mount histopathology (WMHP) Gleason score (GS) and PI-RADSv2. METHODS: This retrospective study included 323 PCa tumors in 254 men, who underwent 3T MRI prior to prostatectomy, 7/2009-12/2016. Qualitative DCE curve types included type 1 (progressive), type 2 (plateau) and type 3 (washout). Quantitative DCE-MRI pharmacokinetic (PK) parameters included Ktrans (influx volume transfer coefficient), Kep (efflux reflux rate constant) and iAUC (initial area under the curve). DCE-MRI features of true positive lesions were evaluated for overall, index, transition zone (TZ) and peripheral zone (PZ), based on GS grade (low = 6, high > 6) and PI-RADSv2 score using SPSSv24. RESULTS: There were 57 (17.6%) low-grade and 266 (82.4%) high-grade PCa lesions. PI-RADSv2 3, 4 and 5 included 106, 120 and 97 lesions, respectively. 251 (77.7%) and 72 (22.3%) lesions were located in PZ and TZ, respectively. High-grade lesions had significantly higher proportion of Type 3 curves compared to low-grade lesions in overall (70.3% vs. 54.4%) and TZ (73.5% vs. 43.5%). As PI-RADSv2 increased, the proportion of type 3 curve significantly increased for overall (80.4-51.9%), index (80.4-54.7%) and PZ (78.7-52.1%) lesions. Among PK parameters, Ktrans (0.43 vs 0.32) and iAUC (8.99 vs 6.9) for overall PCa, Ktrans (0.43 vs 0.31) and iAUC (9 vs 6.67) for PZ PCa, and iAUC (8.94 vs 7.42) for index PCa were significantly higher for high-grade versus low-grade lesions. Also, Ktrans (0.51-0.34), Kep (1.75-1.29) and iAUC (9.79-7.6) for overall PCa, Ktrans (0.53-0.32), Kep (1.81-1.26) and iAUC (9.83-7.34) for PZ PCa; and Kep (1.79-1.17) and iAUC (11.3-8.45) for index PCa increased significantly with a higher PI-RADSv2 score. CONCLUSIONS: The results of study show the possible utility of qualitative and quantitative DCE-MRI parameters for assessment of PCa GS and PI-RADSv2 categorization.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias da Próstata , Meios de Contraste , Humanos , Masculino , Gradação de Tumores , Prostatectomia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/cirurgia , Estudos Retrospectivos
4.
Eur Radiol ; 30(3): 1813-1821, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31822975

RESUMO

PURPOSE: To evaluate therapeutic efficacy and complication of percutaneous thermal ablation of subcapsular hepatocellular carcinomas (HCCs), and how these may be influenced by the degree of tumor to liver surface contact and tumor protrusion from liver surface. MATERIALS AND METHODS: Our retrospective study was approved by the Institutional Review Board. Between January 2006 and December 2013, 290 patients (82 women, 208 men; mean age, 64.5 years; range, 33-89 years) with 474 subcapsular (within 1 cm to the liver surface) HCCs (mean size, 23.7 mm; range, 6-71 mm) underwent percutaneous thermal ablation. The HCCs were divided into surface contact group (n = 243) and non-surface contact group (n = 231). The former was further subdivided into exophytic and non-exophytic HCCs. Technical success, primary technique efficacy, local tumor progression (LTP), and secondary technique efficacy rates were analyzed and compared by the chi-square test or Fisher exact test. Prognostic factors for LTP and secondary technique efficacy were assessed using the Cox regression model. Major complications were also assessed. RESULTS: With median follow-up of 15 months (range, 1-87 months), technical success and primary technique efficacy were 98.7% and 95.7% % in the non-surface contact group; 96.4% and 94.0% in the non-exophytic group; and 100% and 94.7% in the exophytic group (p > 0.05). Tumor size > 3 cm was a significant predictor for LTP, but not for secondary efficacy. Overall major complication rate was 3.8% (24/624) and was not different among the three groups. CONCLUSION: Subcapsular HCCs can be effectively treated with thermal ablation techniques. Degree of tumor-surface contact including moderate protrusion does not appear to limit feasibility or procedure effectiveness. KEY POINTS: • Subcapsular HCCs can be effectively treated with thermal therapy when proper image-guided technique and assistive techniques are applied. • Degree of tumor surface contact including moderate protrusion does not appear to limit feasibility or procedure effectiveness. • Major complications after percutaneous thermal ablation of subcapsular HCCs such as tumor seeding can be minimized by avoiding breach of the tumor capsule exposed to the peritoneal surface and use of tract ablation.


Assuntos
Carcinoma Hepatocelular/cirurgia , Ablação por Cateter/métodos , Neoplasias Hepáticas/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/diagnóstico , Feminino , Humanos , Hipertermia Induzida , Neoplasias Hepáticas/diagnóstico , Masculino , Pessoa de Meia-Idade , Inoculação de Neoplasia , Estudos Retrospectivos , Resultado do Tratamento
5.
AJR Am J Roentgenol ; 212(6): W122-W131, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30995090

RESUMO

OBJECTIVE. The purpose of this study is to determine the overall and sector-based performance of 3-T multiparametric MRI for prostate cancer (PCa) detection and localization by using Prostate Imaging-Reporting and Data System version 2 (PI-RADSv2) scoring and segmentation compared with whole-mount histopathologic analysis. MATERIALS AND METHODS. Multiparametric 3-T MRI examinations of 415 consecutive men were compared with thin-section whole-mount histopathologic analysis. A genitourinary radiologist and pathologist collectively determined concordance. Two radiologists assigned PI-RADSv2 categories and sectoral location to all detected foci by consensus. Tumor detection rates were calculated for clinical and pathologic (Gleason score) variables. Both rigid and adjusted sector-matching models were used to account for fixation-related issues. RESULTS. The 415 patients had 863 PCa foci (52.7% had a Gleason score ≥ 7, 61.9% were ≥ 1 cm, and 90.4% (375/415) of index lesions were ≥ 1 cm) and 16,185 prostate sectors. Multiparametric MRI enabled greater detection of PCa lesions 1 cm or larger (all lesions vs index lesions, 61.6% vs 81.6%), lesions with Gleason score greater than or equal to 7 (all lesions vs index lesions, 71.4% vs 80.9%), and index lesions with both Gleason score greater than or equal to 7 and size 1 cm or larger (83.3%). Higher sensitivity was obtained for adjusted versus rigid tumor localization for all lesions (56.0% vs 28.5%), index lesions (55.4% vs 34.3%), lesions with Gleason score greater than or equal to 7 (55.7% vs 36.0%), and index lesions 1 cm or larger (56.1% vs 35.0%). Multiparametric 3-T MRI had similarly high specificity (96.0-97.9%) for overall and index tumor localization with adjusted and rigid sector-matching approaches. CONCLUSION. Using 3-T multiparametric MRI and PI-RADSv2, we achieved the highest sensitivity (83.3%) for the detection of lesions 1 cm or larger with Gleason score greater than or equal to 7. Sectoral localization of PCa within the prostate was moderate and was better with an adjusted model than with a rigid model.

6.
IEEE Trans Biomed Eng ; 66(1): 14-22, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-29993431

RESUMO

OBJECTIVE: This investigation was performed to evaluate the registration accuracy between magnetic resonance imaging (MRI) and pathology using three-dimensional (3-D) printed molds. METHODS: Tissue-mimicking prostate phantoms were manufactured with embedded fiducials. The fiducials were used to measure and compare target registration error (TRE) between phantoms that were sliced by hand versus phantoms that were sliced within 3-D-printed molds. Subsequently, ten radical prostatectomy specimens were placed inside molds, scanned with MRI, and then sliced. The ex vivo scan was used to assess the true location of whole mount (WM) slides relative to in vivo MRI. The TRE between WM and in vivo MRI was measured using anatomic landmarks. RESULTS: Manually sliced phantoms had a 4.1-mm mean TRE, whereas mold-sliced phantoms had a 1.9-mm mean TRE. Similarly, mold-assisted slicing reduced mean angular misalignment around the left-right (LR) anatomic axis from 10.7° to 4.5°. However, ex vivo MRI revealed that excised prostates were misaligned within molds, including a mean 14° rotation about the LR axis. The mean in-plane TRE was 3.3 mm using molds alone and 2.2 mm after registration was corrected with ex vivo MRI. CONCLUSION: Patient-specific molds improved accuracy relative to manual slicing techniques in a phantom model. However, the registration accuracy of surgically resected specimens was limited by their imperfect fit within molds. This limitation can be overcome with the addition of ex vivo imaging. SIGNIFICANCE: The accuracy of 3-D-printed molds was characterized, quantifying their utility for facilitating MRI-pathology registration.


Assuntos
Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Próstata , Neoplasias da Próstata , Marcadores Fiduciais , Humanos , Masculino , Imagens de Fantasmas , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia
7.
J Magn Reson Imaging ; 49(1): 270-279, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30069968

RESUMO

BACKGROUND: Patient-specific 3D-printed molds and ex vivo MRI of the resected prostate have been two important strategies to align MRI with whole-mount histopathology (WMHP) for prostate cancer (PCa) research, but the combination of these two strategies has not been systematically evaluated. PURPOSE: To develop and evaluate a system that combines patient-specific 3D-printed molds with ex vivo MRI (ExV) to spatially align in vivo MRI (InV), ExV, and WMHP in PCa patients. STUDY TYPE: Prospective cohort study. POPULATION: Seventeen PCa patients who underwent 3T MRI and robotic-assisted laparoscopic radical prostatectomy (RALP). FIELD STRENGTH/SEQUENCES: T2 -weighted turbo spin-echo sequences at 3T. ASSESSMENT: Immediately after RALP, the fresh whole prostate specimens were imaged in patient-specific 3D-printed molds by 3T MRI and then sectioned to create WMHP slides. The time required for ExV was measured to assess impact on workflow. InV, ExV, and WMHP images were registered. Spatial alignment was evaluated using: slide offset (mm) between ExV slice locations and WMHP slides; overlap of the 3D prostate contour on InV versus ExV using Dice's coefficient (0 to 1); and 2D target registration error (TRE, mm) between corresponding landmarks on InV, ExV, and WMHP. Data are reported as mean ± standard deviation (SD). STATISTICAL TESTING: Differences in 2D TRE before versus after registration were compared using the Wilcoxon signed-rank test (P < 0.05 considered significant). RESULTS: ExV (duration 115 ± 15 min) was successfully incorporated into the workflow for all cases. Absolute slide offset was 1.58 ± 1.57 mm. Dice's coefficient was 0.865 ± 0.035. 2D TRE was significantly reduced after registration (P < 0.01) with mean (±SD of per patient means) of 1.9 ± 0.6 mm for InV versus ExV, 1.4 ± 0.5 mm for WMHP versus ExV, and 2.0 ± 0.5 mm for WMHP versus InV. DATA CONCLUSION: The proposed system combines patient-specific 3D-printed molds with ExV to achieve spatial alignment between InV, ExV, and WMHP with mean 2D TRE of 1-2 mm. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;49:270-279.


Assuntos
Imageamento por Ressonância Magnética , Impressão Tridimensional , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Idoso , Desenho de Equipamento , Humanos , Laparoscopia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Prostatectomia/métodos , Reprodutibilidade dos Testes , Procedimentos Cirúrgicos Robóticos , Robótica , Glândulas Seminais/patologia
8.
Hepatology ; 65(6): 1979-1990, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28170115

RESUMO

In a long-term (10-year) study of radiofrequency ablation (RFA) of hepatocellular carcinoma (HCC) as bridging therapy in patients listed for orthotopic liver transplantation (LT), we evaluated the impact of RFA on waiting list dropout rate, post-LT tumor recurrence, and long-term intention-to-treat, disease-specific survival (DSS). From March 2004 to October 2014, RFA was performed as the initial stand-alone bridge therapy to LT for 121 patients (men/women ratio, 83:38; mean age, 60.0 years) with 156 de novo HCCs (mean size, 2.4 cm). Follow-up period from initial RFA ranged from 1.3 to 128.0 months (median, 42.9 months). We assessed the overall and tumor-specific waiting list dropout rates, post-LT tumor recurrence, and 10-year post-LT and intention-to-treat survival rates. Dropout from the waiting list due to tumor progression occurred in 7.4% of patients. HCC recurrence after LT occurred in 5.6% of patients. The post-LT overall survival (OS) rate at 5 and 10 years was 75.8% and 42.2%, respectively, and the recurrence-free survival (RFS) rate was 71.1% and 39.6%, respectively. Intention-to-treat OS, RFS, and DSS rates for the entire study population at 5 and 10 years were 63.5% and 41.2%, 60.8% and 37.7%, and 89.5% and 89.5%, respectively. CONCLUSION: RFA as a first-line stand-alone bridge therapy to LT achieves excellent long-term overall and tumor-specific survivals, with a low dropout rate from tumor progression despite long wait list times and a sustained low tumor recurrence rate upon post-LT follow-up of up to 10 years. (Hepatology 2017;65:1979-1990).


Assuntos
Carcinoma Hepatocelular/cirurgia , Ablação por Cateter/métodos , Doença Hepática Terminal/cirurgia , Hepatectomia/métodos , Neoplasias Hepáticas/cirurgia , Transplante de Fígado/métodos , Centros Médicos Acadêmicos , Adulto , Idoso , Análise de Variância , California , Carcinoma Hepatocelular/mortalidade , Carcinoma Hepatocelular/patologia , Causas de Morte , Estudos de Coortes , Doença Hepática Terminal/mortalidade , Doença Hepática Terminal/patologia , Feminino , Seguimentos , Humanos , Análise de Intenção de Tratamento , Estimativa de Kaplan-Meier , Neoplasias Hepáticas/mortalidade , Neoplasias Hepáticas/patologia , Transplante de Fígado/mortalidade , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/mortalidade , Recidiva Local de Neoplasia/patologia , Recidiva Local de Neoplasia/cirurgia , Pacientes Desistentes do Tratamento , Estudos Retrospectivos , Medição de Risco , Estatísticas não Paramétricas , Análise de Sobrevida , Fatores de Tempo , Resultado do Tratamento , Listas de Espera
9.
Radiology ; 283(1): 130-139, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-27861110

RESUMO

Purpose To determine the diagnostic yield of in-bore 3-T magnetic resonance (MR) imaging-guided prostate biopsy and stratify performance according to Prostate Imaging Reporting and Data System (PI-RADS) versions 1 and 2. Materials and Methods This study was HIPAA compliant and institution review board approved. In-bore 3-T MR-guided prostate biopsy was performed in 134 targets in 106 men who (a) had not previously undergone prostate biopsy, (b) had prior negative biopsy findings with increased prostate-specific antigen (PSA) level, or (c) had a prior history of prostate cancer with increasing PSA level. Clinical, diagnostic 3-T MR imaging was performed with in-bore guided prostate biopsy, and pathology data were collected. The diagnostic yields of MR-guided biopsy per patient and target were analyzed, and differences between biopsy targets with negative and positive findings were determined. Results of logistic regression and areas under the curve were compared between PI-RADS versions 1 and 2. Results Prostate cancer was detected in 63 of 106 patients (59.4%) and in 72 of 134 targets (53.7%) with 3-T MR imaging. Forty-nine of 72 targets (68.0%) had clinically significant cancer (Gleason score ≥ 7). One complication occurred (urosepsis, 0.9%). Patients who had positive target findings had lower apparent diffusion coefficient values (875 × 10-6 mm2/sec vs 1111 × 10-6 mm2/sec, respectively; P < .01), smaller prostate volume (47.2 cm3 vs 75.4 cm3, respectively; P < .01), higher PSA density (0.16 vs 0.10, respectively; P < .01), and higher proportion of PI-RADS version 2 category 3-5 scores when compared with patients with negative target findings. MR targets with PI-RADS version 2 category 2, 3, 4, and 5 scores had a positive diagnostic yield of three of 23 (13.0%), six of 31 (19.4%), 39 of 50 (78.0%), and 24 of 29 (82.8%) targets, respectively. No differences were detected in areas under the curve for PI-RADS version 2 versus 1. Conclusion In-bore 3-T MR-guided biopsy is safe and effective for prostate cancer diagnosis when stratified according to PI-RADS versions 1 and 2. ©RSNA, 2016.


Assuntos
Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Adulto , Idoso , Humanos , Biópsia Guiada por Imagem , Masculino , Pessoa de Meia-Idade , Próstata/diagnóstico por imagem , Próstata/patologia , Curva ROC , Sistemas de Informação em Radiologia , Reprodutibilidade dos Testes , Estudos Retrospectivos
10.
J Vasc Interv Radiol ; 27(4): 496-502; quiz 503, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26922977

RESUMO

PURPOSE: To evaluate the technique, efficacy, safety, and clinical outcomes of CT-guided microwave ablation of tumors in the hepatic dome. MATERIALS AND METHODS: Retrospective review was conducted of 46 consecutive patients (31 men and 15 women; mean age, 64 y) treated with CT-guided microwave ablation for hepatic-dome tumors between June 2011 and December 2014. Baseline demographics of sex, tumor diagnosis, tumor location, tumor size, and technical details were recorded. Technical success was evaluated. Treatment response was assessed per European Association for the Study of the Liver criteria. Overall success and overall survival were calculated, and complications were recorded. RESULTS: Forty-eight tumors were treated. Tumor locations included segments VIII (n = 32), VII (n = 10), and VIa (n = 6). Mean tumor size was 2.4 cm (range, 0.9-5.2 cm). Thirty-four tumors (70%) were treated following creation of artificial ascites with 0.9% normal saline solution (mean volume, 1,237 mL; range, 300-3,000 mL). The technical success rate was 100%, and the complete response rate was 94%. Overall survival rate was 73.9% over 24.7 months of follow-up. There were no major complications. Two patients experienced small, asymptomatic pneumothoraces that were aspirated at the time of the procedure and required no further treatment. CONCLUSIONS: CT-guided microwave ablation of tumors in the hepatic dome is associated with a high technical success rate, high complete response rate, and low complication rate.


Assuntos
Carcinoma Hepatocelular/cirurgia , Ablação por Cateter/métodos , Neoplasias Hepáticas/cirurgia , Micro-Ondas/uso terapêutico , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/mortalidade , Carcinoma Hepatocelular/patologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/mortalidade , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/mortalidade , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética , Masculino , Micro-Ondas/efeitos adversos , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
11.
J Urol ; 194(5): 1428-32, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26094806

RESUMO

PURPOSE: We describe the indications, technique and outcome of transrenal antegrade ureteral occlusion. MATERIALS AND METHODS: An institutional database was used to retrospectively identify patients who underwent image guided transrenal ureteral occlusion between December 1998 and March 2014. Platinum coils were deployed into the distal ureter or 4 to 5 cm proximal to the site of ureteral leak. Gelfoam® pledgets were injected in the ureter at the level of the coils. Additional coils were deployed to trap the pledgets in the distal ureter. RESULTS: Between December 1998 and March 2014, 12 men and 12 women with a mean age of 69 years (range 45 to 87) underwent fluoroscopically guided, transrenal antegrade ureteral occlusion for intractable hematuria in 7 and urinary fistula in 17. A total of 39 ureteral units were occluded, including 3 on the right side, 6 on the left side and 30 that were bilateral. Ureteral occlusion was successful in 35 of 37 renal units (94.6%) as determined by post-procedure antegrade nephrostogram and resolution of clinical symptoms of hematuria and/or urinary leakage. Repeat occlusion was necessary to achieve total ureteral occlusion in 2 of 35 renal units (5.7%). CONCLUSIONS: Percutaneous ureteral occlusion with platinum coils and Gelfoam offers a treatment option for patients with refractory urinary fistula and intractable hematuria in whom standard methods of urinary diversion fail.


Assuntos
Embolização Terapêutica/métodos , Hematúria/terapia , Fístula Urinária/terapia , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Hematúria/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Fístula Urinária/diagnóstico , Urografia
12.
AJR Am J Roentgenol ; 204(4): 865-7, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25794079

RESUMO

OBJECTIVE: The purpose of this study was to evaluate the effectiveness of retroperitoneal organ displacement for image-guided percutaneous biopsy. CONCLUSION: Organ displacement using 0.9% saline or 5% dextrose in water (D5W) can create safe access routes for targeted abdominal and pelvic biopsies.


Assuntos
Abdome , Biópsia Guiada por Imagem/métodos , Pelve , Espaço Retroperitoneal , Idoso , Idoso de 80 Anos ou mais , Feminino , Glucose/administração & dosagem , Humanos , Injeções , Masculino , Pessoa de Meia-Idade , Cloreto de Sódio/administração & dosagem , Tomografia Computadorizada por Raios X , Água/administração & dosagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...