Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Prosthet Orthot Int ; 2024 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-38227682

RESUMO

BACKGROUND: Although postoperative complications of lower limb amputations and complications related to prosthetics are well known, complications before prosthetic fitting are less often emphasized in literature. There are no Saudi studies documenting the complications before prosthetic fitting where there is high rise in dysvascular amputation, and early prosthetic provision remains a challenge. OBJECTIVES: To investigate the complications following major lower limb amputations (MLLAs). STUDY DESIGN: Retrospective study. METHODS: One hundred thirty-six electronic files for individuals with major lower limb amputations were reviewed. Individuals visiting the primary limb loss clinic for the first time, who have not been fitted with a prosthesis before, were included. RESULTS: Muscle weakness was the most common complication (55.1%), followed by edema (52.9%), while infection was found to be the least frequent (5.1%). Age was significantly associated with etiology ( p value < 0.001), usage of assistive device ( p value = 0.002), and complications ( p value = 0.013). Complications were also significantly associated with time since amputation ( p value = 0.001). In addition, etiology was significantly associated with the usage of assistive device ( p value = 0.012). CONCLUSIONS: Muscle weakness and edema were the most common complications after MLLA in a cohort of patients with median onset of 8.5 ± 6.8 months since amputation. Presence of various complications in MLLAs before prosthetic evaluation reflect gaps of care including delayed prosthetic evaluation. National strategies need to be introduced to promote early rehabilitation interventions, prevent complications, and improve quality of life of individuals with MLLAs.

2.
Prosthet Orthot Int ; 47(3): 288-292, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-36705663

RESUMO

BACKGROUND: Partial-hand amputations are the most common level of upper-limb amputations which can lead to cosmetic and functional problems. Partial-hand amputations can be acquired or congenital. Cosmetic silicone prostheses are used in the management of partial-hand amputation; however, a literature review shows that most of the studies are on the fabrication of prosthesis, and data remain deficient on the satisfaction of users with silicone prostheses. OBJECTIVES: To assess the satisfaction of individuals after they were fitted with cosmetic silicone prostheses for partial-hand amputations. STUDY DESIGN: Cross-sectional study. METHODS: Fifty-four participants with partial-hand amputations and who received cosmetic silicone prostheses participated in the survey using the validated Arabic version of the Client Satisfaction with Device (CSD-Ar). RESULTS: Nearly half of the participants were using their silicone prosthesis daily. Most of the patients reported satisfaction with durability and donning, whereas most of the patients were dissatisfied with comfort. The mean of CSD-Ar total score was 16.8 ± 4.7 of 32. The CSD-Ar total score was significantly associated with the side of amputation ( p -value = 0.014) and usage of prosthesis ( p -value < 0.001). CONCLUSION: The satisfaction of individuals with partial-hand amputations can be enhanced by fitting them with cosmetic silicone prostheses. However, these prostheses should meet certain criteria including fitting, weight, comfort, donning, appearance, durability, skin abrasion and irritation, and pain. Individuals' expectations and concerns should be considered as well.


Assuntos
Membros Artificiais , Silicones , Humanos , Desenho de Prótese , Estudos Transversais , Amputação Cirúrgica , Satisfação Pessoal
3.
Prosthet Orthot Int ; 46(1): 54-60, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34772866

RESUMO

BACKGROUND: Changes in residuum volume are a common problem in lower-limb amputees during prosthesis usage, and can lead to poor suspension, impaired gait, and tissue damage. Residuum volume can be affected by the in-socket air pressure, which will influence fluid flow in and around the residuum. The use of "active" pumps to reduce air pressure has been shown to conserve the residuum volume, but these are expensive and unlikely to be widely available. An alternative, passive approach, based on Boyles' law, is to introduce a larger distal void volume at the end of the socket and hence reduce the change in pressure for a given change in volume. OBJECTIVES: To compare the performance across three test conditions (passive-conventional, with standard distal void; passive-with increased distal void; and active system) in terms of residuum volume changes and comfort. STUDY DESIGN: Repeated-measures experiment under three test conditions. METHODS: Five transtibial amputee participants (three males and two females), aged between 27 and 67 years, and of mobility grade K2 or K3, were fitted with a bespoke test prosthesis that was adapted to include the three test conditions. Residuum volume was measured before and after walking under each test condition (presented in a random order). Comfort was also assessed after walking with each test condition. RESULTS: The reduction in residuum volume, relative to the baseline volume, was higher for the conventional passive system (4.2% ± 2.8%) compared with the modified passive (1.4% ± 1.4%) and active (1.6% ± 1.1%) systems. CONCLUSION: The use of a passive suspension system with an increased distal void within the socket may help to stabilize the residuum volume during prosthesis usage.


Assuntos
Amputados , Membros Artificiais , Adulto , Idoso , Feminino , Marcha , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Tíbia/cirurgia , Caminhada
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...