2.
Pacing Clin Electrophysiol ; 24(4 Pt 1): 424-9, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11341078

RESUMO

The purpose of this study was to determine if intraatrial electrograms (EGMs) are required to diagnose specific types of atrial tachyarrhythmias detected by pacemaker diagnostics. DDD pacemakers in 56 patients were programmed to store episodes of atrial tachyarrhythmias. Some episodes had a stored atrial EGM snapshot of the atrial tachyarrhythmia. The EGMs were analyzed to confirm whether the stored episodes were true atrial tachyarrhythmias or other pacemaker-sensed events. EGM confirmation of atrial tachyarrhythmias correlated with increasing duration and rate of episodes. In particular, using EGMs, 8 (18%) of 44 episodes < 10 seconds in duration confirmed atrial tachyarrhythmias compared to 16 (89%) of 18 episodes > 5 minutes in duration (P < 0.001). Only 10 (18%) of 56 detected atrial arrhythmia episodes at rates < 250 complexes per minute were confirmed by the atrial EGM as true arrhythmias compared to 33 (57%) of 58 detected episodes at rates > 250/min (P < 0.001) Twenty-nine (91%) of 32 EGM confirmed episodes of atrial fibrillation/flutter had an atrial rate > 250 complexes per minute and were a minimum of 10 seconds in duration. Fifteen (88%) of 17 episodes meeting the combined stored data criteria of > 250 complexes per minute and duration > 5 minutes were confirmed as atrial fibrillation or flutter by stored EGMs. Atrial EGMs identified that 71 (62%) of 114 stored high atrial rate (HAR) episodes were events other than true atrial tachyarrhythmias. Pacemaker diagnostic data with intraatrial EGMs can diagnose specific atrial tachyarrhythmias and identify other pacemaker-sensed events. Stored episodes > 250 complexes per minute and > 5 minutes in duration had a high correlation with atrial fibrillation and flutter.


Assuntos
Fibrilação Atrial/diagnóstico , Flutter Atrial/diagnóstico , Eletrocardiografia/instrumentação , Marca-Passo Artificial , Idoso , Fibrilação Atrial/fisiopatologia , Flutter Atrial/fisiopatologia , Dispositivos de Armazenamento em Computador , Feminino , Seguimentos , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador/instrumentação , Software , Taquicardia Paroxística/diagnóstico , Taquicardia Paroxística/fisiopatologia , Taquicardia Paroxística/terapia
3.
J Cardiovasc Electrophysiol ; 10(6): 809-16, 1999 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10376918

RESUMO

INTRODUCTION: Although decreased vagal tone, as measured by heart rate variability is a risk factor for ventricular fibrillation (VF) and sudden cardiac death, it is unknown whether increasing vagal tone has an antiarrhythmic effect. The purpose of this study was to determine whether edrophonium hydrochloride (HCI), a vagomimetic agent, increases VF threshold. METHODS AND RESULTS: Twenty-eight consecutive patients with previously implanted defibrillators had two inductions of VF by monophasic direct-current shocks delivered at 10 to 30 msec after the T wave peak, escalating energies (0.4, 1, then 3 J) until VF was induced. If VF was not induced, this protocol was repeated at the T wave peak and then at 10 to 30 msec before the T wave until VF was induced. Patients were randomized to receive edrophonium HCl (12 to 18 mg) or no drug before repeating the protocol for the second VF induction. The mean sinus cycle length increased from 782 to 872 msec in the group receiving edrophonium HCI (P = 0.006 ). In the control group, the mean sinus cycle length remained unchanged (838 vs 858 msec). The mean energy to induce VF, coupling interval relative to the T wave, and the number of attempts to induce VF were not different between VF induction attempts 1 and 2, and they were not different between the group receiving edrophonium HCl and the control group. CONCLUSION: In a sedated patient population with implantable defibrillators, edrophonium HCI infusion prolongs sinus cycle length but does not change inducibility of VF using T wave shocks.


Assuntos
Inibidores da Colinesterase/farmacologia , Edrofônio/farmacologia , Receptores Muscarínicos/fisiologia , Fibrilação Ventricular/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Receptores Muscarínicos/efeitos dos fármacos